H2scan’s HY-ALERTA™ 600 Fixed Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit. The monitor is
designed for either ceiling or wall mount and has an RS422 capability that extends the interface from the sensor to the controller to several hundred feet. H2scan's hydrogen-specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
Performance
Hydrogen Sensitivity Range:
0.4% to 5.0% hydrogen by volume
10% to 125% hydrogen lower flammable limit
Accuracy: ± (3.0% of indication + 2000ppm)
Typical Response Time: T90 less than 30 sec
Ingress Protection: IP64 capable
Calibration Interval: 90 days
Product Life Expectancy: 10 years
Interface Options
Input Voltage Range: 8VDC to 13VDC
Input Current: 0.5A
Analog Outputs:
Output Voltages - OR - Output Currents
• 0VDC to 5VDC • 4mA to 20mA
• 1VDC to 5VDC • 0mA to 20mA
• 0VDC to 4VDC • User-specific mA range
• 0.5VDC to 4.5VDC
• User-specific VDC range
Serial Communication Options: RS232 or RS422
Relay Contacts: Two programmable 60VDC/1A
SPDT relays with both normally open (N.O.)
and normally closed (N.C.) contacts.
Operating Conditions
Operating Temperature Range: -20ºC to 40ºC
Storage Temperature Range: -40ºC to 50ºC
Operating Humidity: 0% to 95% RH
Calibration Background Gas: Air
|
|
What if you could maintain and manage your fixedpoint gas monitor fleet without leaving your desk?
The advantages would be significant. Manually calibrating every fixed monitor in a facility is a time consuming distraction from your core business. The units may be in hard-to-reach places creating additional safety hazards. These and other obstacles make it difficult to follow industry best practices for routine testing and calibration.
iTrans™ DS2 Docking Station™ is the first system to automate calibration, record-keeping and instrument
diagnostics for fixed-point gas monitors. Hands-off maintenance and a snapshot view of your entire gas
monitor fleet allow you to:
• Maintain your gas monitors more safely, efficiently and reliably
• Increase equipment reliability
• Eliminate safety concerns
• Save money on calibration and testing
• Focus more resources toward your core business
A graphical user interface tool allows an administrator to view operations on each Docking Station from a network computer. From here, you can initiate calibrations and instrument tests remotely, print reports, set events, and run diagnostics for any or all instruments at any location.
The DS2’s flexible architecture minimizes installation costs, whether you’re managing one instrument or an entire fleet of fixed-mounted or portable instruments.
|
|
Series 9000 cross stack infrared, in-situ carbon monoxide monitors provide high accuracy and reliability, coupled with straightforward installation and setup and is suitable for a wide range of industrial combustion efficiency monitoring applications. This carbon monoxide monitor is designed to provide the operator with a fast response measurement, essential to the efficient combustion control of any boiler system.
Product Range:
Model 9100 Carbon Monoxide Monitor
Model 9200 MkII High Performance Carbon Monoxide Monitor
Features and Benefits:
Direct continuous measurement of Carbon Monoxide
True representative measurement - reading averaged across entire duct
Improved combustion control and efficiency savings
Low running and maintenance cost
High reliability - robust design
Simple installation - advanced alignment features
Over 20 years of experience in carbon monoxide monitoring - 4th generation product
The 9200 MkII has all the facilities of the 9100 with the addition of:
Clear stack, open path gas calibration
Automatic cell leak detection
4 gas cell, TUV approved measurement technique
Automatic duct pressure correction
|
|
H2scan’s HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit. H2scan's hydrogen-specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false positive alarms.
Performance
Hydrogen Sensitivity Range:
0.4% to 5% hydrogen by volume
10% to 125% hydrogen lower flammable limit
Accuracy: ± (0.03 x indication + 0.2) percent hydrogen by volume
Typical Response Time: T90 of 60 sec maximum
Ingress Protection: IP64 capable
Calibration Interval: 90 days
Product Life Expectancy: 10 years
Interface Options
Power Barrier Input Voltage: 24 VDC nominal
Power Barrier Input Voltage Range: 20 VDC to 28 VDC
Intrinsically Safe Sensor Input Voltage: 10 VDC
Sensor Input Voltage Range: 5 VDC to 28 VDC
Input Power: 10 W
Analog Outputs: 4 mA to 20 mA
Serial Communication: RS422
Operating Conditions
Operating Humidity: 0% to 95% RH
Operating Temperature Range: -20ºC to 40ºC
Storage Temperature Range: -40ºC to 50ºC
Calibration Background Gas: Air
Included Accessories
Intrinsically Safe Power Barrier
4 m Power / Analog Cable
Optional Accessories
Intrinsically Safe Analog Output Barrier
Intrinsically Safe Serial Interface Barrier
4 m RS422 Serial Interface Cable
Dimensions
Total Length: 8.1 in.
Total Width: 4.4 in.
Depth: 1.6 in.
|
|
PART # HGDI-SR (SINGLE RELAY)
HGDI-DR (DUAL RELAY)
Hydrogen Gas Detector
Lead-acid storage batteries emit hydrogen while gassing during charge. Hydrogen concentration of 4% to 75% by volume in air are potentially explosive. Hydrogen gas detector is designed to provide for dissipation and warning before any concentration reaches the lower explosive limit (LEL) of 4%.
- 1% Concentration energizes a relay which activates your exhaust fan
- 2% Concentration activates a built-in, pulsating warning alarm
- One-Year Warranty
- 110V; 50/60 htz
- 220VAC or 12VDC available
- 7"h x 4 3/4"w - 2 1/2" deep
ADDITIONAL PARTS:
HGDI-REMOTE - 20FT
HGDI-JUNCTION BOX
HGDI-TEST & CALIBRATE
|
|
The Bacharach HGMSZ (Halogen Gas Monitor Single Zone) is designed for continuous single-point monitoring of CFC, HFC, HCFC and Halon refrigerant gases. The HGMSZ displays the type of gas being monitored, along with displaying both the current gas level and the peak gas level detected on its front panel LCD. The instrument retains a log of previous readings that can be easily accessed for analysis.
An internal audible alarm and front panel indicators are provided to signal alarm and fault conditions, and relay contacts can be used to trigger external alarm devices in the event of a system fault, or if a leak (small), spill (medium), or evacuation (large) level of gas is detected. The system also includes a 4%u201320 mA current loop interface that can be connected to remote monitoring equipment.
|
|
The Tocsin 103 series of gas detectors are designed for cost effective safe area gas detection solutions. They incorporate micro processor technology to give a stable 4-20mA process signal output or digital addressable output. The addressable output option allows detectors to be networked on a single cable run giving dramatic reduction in installation costs. The in built processor can be used to pre-calibrate the sensor prior to installation. Alternatively calibration can be achieved on site via the Oliver IGD control panel or locally using a handheld PC device or laptop. A range of sensing technologies can be incorporated into the housing to provide the most appropriate detection method.
ATEX VERSIONS (TOCSIN 102) AVAILABLE
Available sensor types include
IGD’s own MKIII and Type B Pellistors,
Infra Red
Electrochemical Devices
Gas Detected Include
Flammable Gases
Carbon Dioxide
Carbon Monoxide
Nitric Oxide
Nitrogen Dioxide
Hydrogen Cyanide
Chlorine
Hydrogen Sulphide
Ammonia
Oxygen
Sulphur Dioxide
Hydrogen Chloride
ATEX VERSIONS ALSO AVAILABLE
|
|
|
In line with its continuous commitment to meeting customer demand for more cost-effective and reliable customtailored gas detection solutions, Vulcain introduces the next generation of stand-alone gas monitors—the Vulcain 301M Dual Gas Monitor. Like its predecessor, the Vulcain 301M is an advanced microprocessor-based system that features a high quality controller, a high-tech enclosure designed to provide maximum effectiveness and durability, and all the characteristics required to ensure continuous, accurate and fully integrated monitoring of hazardous gases and combustibles.
|
|
CMS-2 Carbon Monoxide Monitor/Alarm
The CMS-2 is a field portable carbon monoxide monitor and alarm for respirator air supply. If CO exceeds 10 ppm, it triggers a warning light, and a high-decibel audible alarm. The rugged case with comfortable carrying handle, protects the monitor from minor impacts. Used by blasting and painting contractors for field operations.
Available Literature:
23248 - CMS 1 & 2 Carbon Monoxide Alarms
|
|
|
The Model S4000CH Intelligent Sensor is a microprocessor- based transmitter designed for use with General Monitors' catalytic bead sensors. The unit features one person calibration and can virtually self-calibrate by simply activating a magnetic switch and applying gas. It is designed to monitor combustible gases and vapors within the lower explosive limit (LEL) and provide status indication and alarm outputs. Complies with ANSI/ISA 12.13.01-2000 performance requirements for combustible gas detectors.
|
|
|
The Model MC600 is a highly configurable multi-channel controller that provides six channels of continuous gas detection. It is compatible with our fixed hydrocarbon sensors, H2S sensors, as well as our Models S4000CH, S4100C, S4000T, S4100T, IR2100, IR5000, IR7000, TS4000, TS400 and TS420 gas detectors. Dual redundant Modbus communications provides complete status and control capability. Removable terminal blocks provide ease of installation and wiring. Six user configurable 8A relays drive a combination of horns, beacons etc. Modular, plug-in signal input cards allow for system expandability and simplified maintenance. Pre-configured from factory saves installation time with minimum setup required. User selectable zoning and voting for application flexibility.
|
|
|
The Model S4000C Intelligent Sensor is a microprocessor-based transmitter designed for use with General Monitors' catalytic bead sensors. The unit features one person calibration and can virtually self-calibrate by simply activating a magnetic switch and applying gas. It is designed to monitor combustible gases and vapors within the lower explosive limit (LEL) and provide status indication and alarm outputs. Complies with ANSI/ISA 12.13.01-2000 performance requirements for combustible gas detectors.
|
|
|
The S4100T Intelligent Sensor is a highly reliable, self-contained, microprocessor-controlled hydrogen sulphide transmitter with integral 3 digit readout. It is designed to measure and display concentrations of H2S in the 0-20 ppm, 0-50 ppm or 0-100 ppm range, but will continue to display concentrations up to 120% FSD. The sensing element may be incorporated in the transmitter housing or remotely mounted at distances of 600 meters. The sensor employs thin film metal oxide semiconductor (TFMOS) technology as the measuring principle.
|
|
The Model IR400 Infrared Point Detector is a hydrocarbon gas detector that continuously monitors combustible gases and vapors within the lower explosive limit (LEL) and provides alarm indication.
All electronics are contained within an explosion-proof housing so that the IR400's detector information can be processed locally. The IR400 operates with a 4-20mA signal, which is proportional to 0 to 100% LEL gas concentration at the detector. Configurations with analog output, Modbus and HART are available. Modbus and HART data can be used for predictive maintenance.
|
|
|
The Model IR5000 Open-Path Infrared Combustible Gas Monitor is designed for detection of hydrocarbon gases in the 0-5,000 ppm•meter and 0-5 LEL•meter ranges, simultaneously. The IR5000 uses a single beam source and detector to monitor gas concentrations, improving accuracy, reducing drift and improving immunity to false alarms.
|
|
|
The Model TS4000 Intelligent Toxic Gas Detector continuously monitors toxic gases in the ppm range or oxygen deficiency, delivering highly accurate detection and protection. The unit features one person calibration and can virtually self-calibrate by simply activating a magnetic switch and applying gas. It provides status indication and alarm outputs.
|
|
| ... products without technical information |
| |
The Next Generation Partial Discharge Analysis System
The detection and monitoring of partial discharges (PD) is of vital importance because PD phenomena often precede an insulation breakdown of high voltage equipment leading to cost intensive outages and repairs.
The MPD 600 Partial Discharge Analysis System is a high-end, high-precision, modular acquisition and analysis toolkit for detecting, recording, and analyzing partial discharge events in many applications. Its versatility and robustness make the MPD 600 the ideal system for both laboratory and on-site measurements of partial discharge in any kind of electrical equipment such as transformers, rotating machines and cable systems (including HV and EHV cables).
|
|
|
The partial TLA dung measurement of electric motors and generators during the current enterprise is world-wide increasingly used. Thus isolation problems can in time be recognized and revision work be better planned.
|
|
|
Digital and Analog Partial Discharge measuring systems, including coupling capacitors, measuring impedance, noise reduction filters, calibrators, PD bridges, special software for PD evaluation and analysis. HV and LV filters. Shielded enclosures. Complete HV cable test sets. Power Cable Test Van for on-site PD fault location. Automatic PD systems for switchgear, surge arrestors, and transformer/motor windings. Ultrasonic PD Sensors.
|
|
FEATURES
• Multicolored 10-bar (5 green, 3 yellow, 2 red) LED displays state of charge.
• The top LED illuminates only when the battery is properly charged.
• Double flashing red LEDs signal “empty” alarm at 80% discharge.
• Recognizes improperly charged battery.
• Both fixed and adjustable discharge profiles are available.
• Easy to install.
|
|
| ... products without technical information |
| |
Leakwise Oil on Water Monitor
Leakwise Oil on Water MonitorLeakwise Oil-on-Water Monitoring and Detection Systems from GE Analytical Instruments provide early, reliable, low maintenance warning of hydrocarbon leaks and spills 24/7 without false alarms. A Leakwise system consists of a wire or wireless signal processor and one of more sensors, depending on the application.
Leakwise oil detection sensors use high frequency electromagnetic energy absorption floating sensors, which enable reliable monitoring of hydrocarbon on water regardless of dirt or oil coating of the sensor or change in water level or water salinity. Advantages include:
%u2022 Provides reliable coverage 24/7 with no false alarms
%u2022 Operates virtually maintenance free for years
%u2022 Detects oil layer thickness (as little as 0.3 mm)
%u2022 Offers an affordable solution for oil leak detection
Applications include oil leak monitoring at refineries, petrochemical plants, pipelines, gas stations, power plants, underground transmission, remote substations, transformer switchyards, marine ports, airports, steel and aluminum manufacturing plants, offshore rigs, groundwater and stormwater runoff, wastewater treatment plants and more.
Leakwise is also an ideal tool for strengthening Spill Prevention Control and Countermeasure (SPCC) plans, as required by the USEPA.
|
|
|
Oleotrol is an automatic alarm system for water streams which operates continuously so as to prevent damages from oil leaks. It uses a physical property-light reflection from a film of oil on the water surface - to signal small amounts of oil in water streams which are normally oil-free.
|
|
Model 6600 Oil-in-Water Analyzer System
Teledyne's Model 660/661 was the industry standard in oil-in-water analysis for 30 years. The microprocessor based 6600 / 6610 improves upon our proven analog circuitry and the sample handling system. The new, compact modern design incorporates many new features at a significantly reduced cost. Critical features include:
Folded optical system optimized for excellent signal-to-noise ratio and stability
Increased reliability by eliminating many moving parts
New sonicator homogenizes oil (in-line) in water instantly (less than one second)
Improved auto-zero filter system prepares zero fluid for calibration and zeroing without long sparging cycle
Specially developed software with auto calibration features
Automatic self-cleaning sample cell suitable for high pressure and temperature
Manual calibrations done easily with collected zero fluid from sample system using the gravity fed reservoir
Manual or automatic span sensitivity easily checked with internal span flag once field calibrated
Faster response time
Modular design configured to meet specific application requirements
|
|
Watchdog
Multi-Function Hazard Monitor
Belt speed/alignment, bearing temperature, pulley alignment, blockage detection
Full Microprocessor control
Fully programmable via keypad to optimise elevator operation
Simple, reliable, consistent
|
|
Alignment Sensors for Elevators & Conveyors
4B has a wide range of Alignment Sensors designed for both elevators and conveyors in ATEX and non-ATEX areas.
The BAP2 and WDA3 are long-range magnetic sensors for alignment of bucket elevators. They have a pulsed and a continuous output.
The Touchswitch and the CBS are electromechanical sensors. The Touchswitch is for use on elevators and conveyors, whilst the CBS is designed specifically for conveyors.
|
|
|