Nominal voltage: 1 kV
Temperature: -40 °C - 90 °C
Cold and oil-resistant cables for flexible applications under torsional load, halogen-free - 0.6/1 kV ÖLFLEX® TORSION FRNC: UL: cRUus AWM (II A/B) OIL RES I+II, power + control cable 0.6/1 kV, wind turbine ...
U.I. Lapp GmbH
Nominal voltage: 300 V - 1,000 V
Temperature: -55 °C - 145 °C
Cross-section: 1, 1.5 mm²
Electron beam cross-linked cables for more demanding application requirements ÖLFLEX® HEAT 125 C MC - halogen free power and control cable with DNV GL certificate, special fire performance, IEC 60332-3, ...
U.I. Lapp GmbH
Nominal voltage: 600 V - 1,500 V
Temperature: -40 °C - 100 °C
Electron beam cross-linked solar cables with reduced outer diameters ÖLFLEX® SOLAR XLS-R - halogen free electron beam cross-linked solar cable for durable and weather proof use in photovoltaic systems Optimised ...
U.I. Lapp GmbH
... control cable family from igus got support from additional multi-core bundle-stranded diameters. The cables have a minimum bending radius of 7,5 - 15 x d with bundle braided starting at 12 cores (36 and ...
igus®
... conductors. The 22 AWG variant is characterised by exceptionally good loss. The cable with 26 AWG is particularly suitable if less space is available for the cable. • Electrical power ...
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 185 mm²
... torsional conditionally suitable for drag chains the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers flame-retardant ...
HELUKABEL
Nominal voltage: 2,000, 600, 300, 500 V
Temperature: -50 °C - 90 °C
Cross-section: 0.5 mm² - 50 mm²
... PUR control cable with numbered cores Marking for S 980 P 77741807: SAB BRÖCKSKES · D-VIERSEN · 77741812 S 980 P 12 x 0,50 mm² 20 AWG/12c 77742012 UL AWM Style 21060 80°C 600V CSA AWM I/II A/B 80°C 600V FT1 FT2 CE Flexible ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 500, 300 V
Temperature: -40 °C - 70 °C
Cross-section: 0.22, 0.5, 1.5, 0.75, 1 mm²
In this chapter you will find multi-pair compensating and extension cables with PVC insulation for a temperature range up to 70°C.
SAB BROECKSKES GMBH & Co. KG
Temperature: 250 °C
Cross-section: 1, 0.22, 0.5 mm²
The PFA insulated extension cables for thermocouples are used for temperatures up to 250°C. They are available with galvanized as well as with a stainless steel wire armouring.
SAB BROECKSKES GMBH & Co. KG
... As control and control cable in continuously moving applications For installation in energy chains with constant linear movement Construction and material suitable for continuous movement application PVC Flame-retardant, ...
LÜTZE
... technology In dry, damp and wet rooms As a monitoring, measurement and control cable for industrial applications For flexible applications without compulsory guide PVC Flame-retardant, ...
LÜTZE
Nominal voltage: 500, 300 V
Temperature: -40 °C - 80 °C
Cross-section: 0.75 mm²
... technology In dry, damp and wet rooms As a monitoring, measurement and control cable for industrial applications For flexible applications without compulsory guide PVC Flame-retardant, ...
LÜTZE
Nominal voltage: 90 V
Temperature: -25 °C - 80 °C
... /Control Cables in AWG 22, shielded, zero halogen, flame retardant, with small outer jacket. High flexible stranded copper conductor, closed twisted pairs. NET Price per 1m - Cu included UL-approved ...
Metrofunk Kabel-Union
Nominal voltage: 300 V
Temperature: -10 °C - 105 °C
Cross-section: 0.56 mm²
Control Cable with 7-stranded core 0,56 mm² (AWG 20), especially for Insulation-Displacement-Connection (IDC), 1 to 12 pairs, shielded, jacket black
Metrofunk Kabel-Union
Nominal voltage: 300 V
Temperature: -10 °C - 105 °C
Cross-section: 0.34 mm²
Control Cable with 7-stranded core 0,22 mm² (AWG 24), especially for Insulation-Displacement-Connection (IDC), 1 to 12 pairs, shielded, jacket black NET Price per 1m - Cu included Control Cable ...
Metrofunk Kabel-Union
... Installation chord for inner area • Electrical Values Cat.7 (ISO/IEC) class F • Norms ISO/IEC 11801 / EN 50173 • Reaction to Fire halogen free and flame-retardant acc. to IEC ...
Temperature resistant cables For applications where either due to electrical requirements a higher temperature on the core is needed or environmental conditions ask for higher temperatures, we have a ...
Nominal voltage: 300 V - 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 1.5 mm² - 240 mm²
IC AUTOMATION
Nominal voltage: 600 V
Temperature: 80 °C
Cross-section: 0.14 mm² - 95 mm²
IC AUTOMATION
Nominal voltage: 300 V - 1,000 V
Temperature: -40 °C - 100 °C
Cross-section: 0.14 mm² - 0.34 mm²
IC AUTOMATION
... of the cable jacket: blue • coupling attenuation greater than or equal to 85 dB • electrical data tested up to 1500 MHz • GHMT Cat.7A PVP certified • applicable standards: EN 50173-1, ISO/IEC ...
METZ CONNECT
Temperature: -20 °C - 60 °C
Length: 500, 1,000 m
... • color of the cable jacket: blue • coupling attenuation: 80 dB • applicable standards: EN 50173-1, ISO/IEC 11801, EN 50288-4-1 and IEC 61156-5 • cable jacket: LSHF (LSOH) • flame-retardant ...
METZ CONNECT
Temperature: -20 °C - 60 °C
Length: 305, 500, 1,000 m
• 1 GBit installation cable, simplex • unshielded installation cable Cat.6 class E, AWG 23 U/UTP • 4 pairs with separator (spline) • outer diameter: 5.3 mm • color of the cable ...
METZ CONNECT
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 50 mm²
power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in ...
CAE GROUPE
Nominal voltage: 300 V - 500 V
Temperature: -40 °C - 80 °C
power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in dry, ...
CAE GROUPE
Nominal voltage: 300, 500 V
Temperature: -30 °C - 70 °C
Cross-section: 1.75, 1, 0.75 mm²
power, control and connecting cable in electrical facilities, for fixed laying and casually movement without tensile stress and without defined cable routing. Suitable for use in dry, ...
CAE GROUPE
Nominal voltage: 750, 500, 450, 300 V
Temperature: -12 °C - 80 °C
Cross-section: 0.75 mm² - 50 mm²
Carpel flat cable for moving equipment comes in a variety of N° conductors ranging from 6 to 24. The cores are identified according to CEI-UNEL 00722 tables and generally progressive numbering is used, with or without ...
Cross-section: 1.5, 1 mm²
The self-supporting electrical control cable engineered by By carpel is supported by dual side ropes that are inserted in the exterior sheath. This tool is specifically utilized on applications such as ...
Temperature: -40 °C - 125 °C
LMR®- LLPX is an indoor highly fire retardant cable intended specifically for runs within return air handling plenums (e.g. dropped ceilings, raised floors). It has a UL/NEC & CSA rating of 'CMP' and ...
Times Microwave Systems
Nominal voltage: 800 V
Temperature: -30 °C - 70 °C
For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. Not approved for power and underground installation. DIN VDE 0815 ; directive 2014/35/EU RoHS 2011/65/EU EN ...
... to the eco-type. Features Due to the use of our unique technology, this cable has the same flexibility and electrical characteristics as those of conventional cables, despite the ...
Nominal voltage: 2,000 V
Temperature: -40 °C - 80 °C
... applications. The flame retardancy meets the requirements of iec60332-1-2 It has good anti external electromagnetic interference ability LSZH sheath is halogen-free and low smoke Superior transmission performance The ...
Zhaolong Interconnect
Nominal voltage: 3,000 V
Temperature: -190 °C - 250 °C
Cross-section: 0 mm² - 28 mm²
... resistant cables that must guarantee error-free operation even in the case of fire are frequently required in certain equipment and plant as well as at exposed locations in buildings. We develop and make high temperature ...
Temperature: -5 °C - 80 °C
Power supply for electrical applications and drives Transmission of large electrical currents Outer jacket valley-sealed extruded and high abrasion resistant Oil-resistant UV-resistant CFC-free REACH/ROHS ...
TSUBAKI KABELSCHLEPP
Temperature: 90 °C - 260 °C
Length: 15 mm - 55 mm
Our automotive cables are the reliable and efficient connection for each wiring system. We offer an extensive range of products with various OEM and Tier 1 approvals. We supply both by international standards and the ...
LEONI
Nominal voltage: 150 V - 30,000 V
... , UL, BS, DIN/VDE, etc. ZTT also can produce other special cables such as Coaxial cable, Ethernet cable, BUS cable, OPLC, Shore power cable, Port Machinery ...
ZTT
Nominal voltage: 600 V
Temperature: 60, 75, 90 °C
... . CopperConductor XLPE InsulationMoisture /Heat /Low-Temp /Sunlight Resistant Flame Retardant Thermoset Insulated Wire and Cable APPLICATIONS XHHW-2building ...
Shanghai Morn Electric Equipment Company
Nominal voltage: 76 kV - 500 kV
Temperature: 90 °C
Cross-section: 240 mm² - 2,500 mm²
... you: from consulting on design through to implementation of your sophisticated high-voltage cable systems. Brugg Cables advises customers world-wide on new cable systems, as well as ...
Brugg Kabel AG
Nominal voltage: 0 kV
Cross-section: 11.6 mm² - 34 mm²
Shielded Supply cable for brushless motors with PVC Jacket
Brevetti Stendalto
Nominal voltage: 30 V - 200 V
Temperature: -40 °C - 125 °C
Flat Flexible Cables (FFC) Axojump® are made from flat tin or gold plated copper conductors which are insulated with polyamide or polyester tapes. They are designed for board-to-board interconnections in electronic systems. ...
Axon Cable
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining