The BEx explosion proof beacons and status lamps are available as 5, 10, 15 and 21 Joule Xenon beacons or as the revolutionary multi-function L.E.D version. All units are suitable for hazardous area Zones 1, 2, 21 & 22.
Features:
- All units are available in EEx d and EEx de versions
- ATEX, GOST-R, IECEx approved (Xenon version only)
- Dual M20 cable gland entries
- Large termination areas
- Ratchet adjustable mounting brackets
The BEx range also includes:
- 117dB(A) and 123dB(A) alarm sounders
- 15 & 25W loudspeakers (100V, 70V line & 16R, 8R)
- 'Appello' speech and tone voice annunciation models
- Audio-visual combination units (can be operated from a single power source or separately)
|
|
|
|
|
|
Hazardous areas often require the use of optical signals for warning or information purposes. The EExII strobe light dSLB21 offers both of these signalling features. It is designed for continuous operation. If the supply voltage is turned on, the Strobe Light dSLB21 is activated. The device is available in several versions with various levels of operating voltage and flash energy and various signalling colours. The stable, glass-fibre reinforced polyester (GRP) housing is made to the IP66 degree of protection and may be used indoors or outdoors. The II 2 G EEx de IIC T6 protection class enables the unlimited use of the signalling device in all hazardous areas, zones 1 and 2. The flameproof enclosure and the "increased safety" type of protection of the terminal room guarantee hazardous area protection. The upper part of the flameproof enclosure, which contains the flash electronic and the mounted flash tube, consists of a transparent Makrolon-cap. An inner cap lends colour to the light. The housing consists completely of GRP. Thus the device is protected against corrosion, and fulfills the requirements of contact safety class II. An equipotentiel bonding is not required. All outer fastening parts are manufactured
in noncorrosive materials.
|
|
|
|
|
|
|
Hazardous areas often require the use of optical signals for warning or information purposes. The EExII rotating beacon dSLD 21 offers both of these signalling features. It is designed for continuous operation. If the supply voltage is turned on, the rotating beacon dSLD 21 is activated.The device is available in several versions with various levels of operating voltage and and various signallingcolours. The stable, glass-fibre reinforced polyester (GRP) housing is made to the IP66 degree of protection and may be used indoors or outdoors. The II 2 G EEx de IIC T6 protection class enables the unlimited use of the signalling device in all hazardous areas, zones 1 and 2. The flameproof enclosure and the "increased safety" type of protection of the terminal room guarantee hazardous area protection. The upper part of the flameproof enclosure, which contains the electronic and the mounted halogen lamp, consists of a transparent Makroloncap. An inner cap lends colour to the light. The housing consists completely of GRP. Thus the device is protected against corrosion, and fulfills the requirements of contact safety class II. An equipotentiel bonding is not required. All outer fastening parts are manufactured in non corrosive materials.
|
|
|
|
|
|
New DA135 Intrinsically Safe LED Beacon from RTK Instruments
RTK Instruments has developed a new range of LED Beacons, which provide powerful visual alarm signals in both hazardous and safe areas. The DA135 is ATEX certified for use in Zone 0, 1 or 2 hazardous areas and is available in five super-bright colours. The ruggedised and encapsulated enclosure makes this an ideal choice for the harsh environments found offshore and in the chemical and petrochemical industry.
The standard unit has a unique method of allowing the user to change the flash rate between single, double or triple flash by triggering control inputs. Customers can then use the same unit to indicate different site problems. A dual colour version is also available where each colour can be triggered separately from the control inputs
The DA135 can be operated alone or in conjunction with an intrinsically safe Sounder and Pushbutton to create a fully featured single point Alarm Annunciator.
RTK Instruments is a leading supplier of safe and hazardous area alarm, display and interface products and can provide specific application advice, as well as product recommendations and installation assistance.
|
|
|
APS Resource is a recognized leader in providing lasting and economical solutions to safeguard loading dock personnel and warehouses against accidents and damage from poor lighting or poor communication between truck driver and dock workers. APS offers dock lights in many sizes and variations to meet your needs. Our line of safety products has been developed to solve multiple safety concerns at your facility.
|
|
Lightings
Explosion-Proof fluorescent luminaires EEx d IIC.
Explosion-Proof floodlights EE x de IIB.
Explosion-Proof lighting fixture Ex d IIC.
Explosion proof Indicating lights; incandescent lights, rotating lights, flashing lights.
Explosion proof traffic lights EEx d IIC.
|
|
|
|
|
|
Excellent light intensity and high life duration
The new 782 Ex LED beacons stand out from the competition with their modern design and extraordinary brightness. The fluted dome generates an optimal light dispersion. The LEDs in the colour of the dome produce an extremely colour-intense light effect.
Thanks to their low current consumption, these beacons also generate savings in operating costs for users. Due to the innovative LED technology, the beacon has an extremely long life duration of up to 50,000 hours and is maintenance-free. Screwing open the housing to replace the light source is now a thing of the past.
Best temperature class thanks to LEDs
Even in continuous operation the beacons keep a cool head. The cool surface offers even the most ignitable of gases and dusts no reason to explode: With T6 or T 80°C, the device complies with the requirements of the highest temperature classes in Ex areas.
Permanent or rotating light
In addition to the light intensive permanent light variant, a wear-free 782 Ex LED revolving beacon is also available. The rotating beacon is wear-free thanks to the absence of any moving components. Instead, the LEDs are triggered in sequence, generating a strikingly intense signal with a rotating light effect.
Wide range of applications
The new 782 Ex beacons from WERMA can provide signalling in gas or dust explosion hazardous areas. With just one device, the user can cover the zones 1 and 2 as well as 21 and 22.
The robust aluminium and glass housing has a diameter of 195 millimetres and a height of 305 mm. It has a flame-proof enclosure “d” and is equipped with an “e” connection area, making it easy to connect.
|
|
Flashguard LED Beacons
Flashguard weatherproof xenon beacons are ideal visual indicators in a variety of applications.
- Compact, ultra modern sleek appearance
- Long life LED design
- Ease of installation with first-fix option on standard models
- Weatherproof to IP67
- White, high quality polycarbonate housing
- Vandal-resistant safety locking mechanism
- Flashing or static indicators
Overview
Flashguard weatherproof LED beacons are ideal visual indicators in a variety of applications.
All Flashguard LED beacons are low current and have an exceptionally long life compared to traditional types of beacon. They also have a a diffuser for greater visibility and spread of light.
|
|
Blinkers
P123022 - PRL
Protective gauge for LAMPO series blinkers.
D123013 - SLM2
Blinker support for wall applications.
D113696 00003 - LAMP NET
Lamp Net blinker with extractable self-learning FAST-NET receiver for MITTO series rolling code transmitters.
D113686 00001 - LAMPO
AI 24V
Blinker powered at 24Vac/dc with integrated antenna. 4 m antenna cable. Only for receivers operating at a frequency of 433.92Mhz.
D113685 00001 - LAMPO AI 230V
Blinker powered at 230Vac with integrated antenna. 4 m antenna cable. Only for receivers operating at a frequency of 433.92Mhz.
D113719 00003 - RAY X 24V
Blinker powered at24Vac with integrated antenna.
D113719 00002 - RAY X 230V
Blinker powered at 230Vac with integrated antenna.
D113721 00002 - RAY X SA 12V
Blinker powered at12Vac without integrated antenna.
P123023 - RWS
Ray blinker support for wall applications.
D113721 00003 - RAY X SA 24V
Blinker powered at24Vac without integrated antenna.
|
|
* NEMA Type 4X Enclosure
* Panel or conduit mounting
* 18 inch wire leads
The Edwards 104FIN Series AdaptaBeacon flashing halogen lights and 104FLED Series AdaptaBeacon flashing LED lights are designed to provide a bright visual indication utilizing special optics within a shatter resistant polycarbonate lens mounted on a polycarbonate/ABS blend base.
|
|
Fire flash with omnidirectional luminous great power.
Luminous flow amplified by a built-in lens of FRESNEL
Possibility of dry operation per salvo of 2 flashes/, reinforcing the effectiveness of the signal
Long life of life
2 operating processes:
- 60 F.P.M. are an luminous intensity of 10 joules
- 90 F.P.M. are an luminous intensity of 7.5 joules
The passage from 60 to 90 F.P.M. is done by simple displacement of a microphone-switch on the electronic chart or displacement of a rider on the bulb. Base DIN
|
|
Smallest of optical indications, recommended for the desk, control boards, order and cupboard.
60 F.P.M.
Luminous power 1 joule.
Compactness: Diam 70mm X H 30 Misters.
Discrete, easy and effective assembly projecting.
Extra profile low - great effectiveness.
Integrated device of removal of the parasites.
Power flash: 1 Watt.
Lifespan: 100.000 hour
|
|
Range of fires flash AE&T: a varied range allowing you to announce a danger, a machine, an action, a situation, etc in industrial environment.
Our products can be used in interior as in outside and adapt to the conditions more extrèmes.
Our Xénon technology guarantees to you a strong visibility of our fires flash (from 2,5 to 30 joules).
Range:
- PMF: visibility reinforced by Fresnel effect of the cap
- AB/WB/DWB: reinforced against the shocks and vibrations
- FP: flexibility and reduced storage cost
- TL101/L101S: compact and encastrable
- WBR/Quadro: very severe environments
- PB: compact and powerful
Ask our booklet by contacting us on info@aet.fr (reference: DirInduFlash)
|
|
Federal Signal's Electraflash® Model 141 is an economical incandescent flashing light. The Electraflash is less than six inches high and six inches in diameter. It is available in five impact- resistant fresnel dome colors: amber, blue, clear, green and red. The 120VAC model is UL Listed and CSA Certified.
- Available in 12VDC, 24VDC, 36VDC and 120VAC
- Five dome colors
- Surface mount or integrated 1/2- inch pipe mount
- Type 3R enclosure
- UL Listed, CSA Certified
|
|
Standalone flashing lights, warning lights FEBOLIXA - Orange Flashing light 12 VDC, Xenon lamp 3 W
FEBOLIFA24 - Orange Flashing light 24 VDC, fi lament lamp 25 W
FEBOLIFA - Orange Flashing light 230 VAC, fi lament lamp 25 W
FEBOLA - Orange warning light 230 VAC, 12 V, fi lament lamp 25 W
|
|
| ... products without technical information |
| |
The SpectrAlarm range from E2S has been designed to offer high performance audible and visual signalling in a single unit. Sound outputs of up to 126dB can now be combined with a powerful beacon from a choice of rotating mirror, flashing xenon or LED technologies.
Features:
- Three sizes of sounders: 112db(A), 119dB(A) and 126dB(A) @ 1m
- Three types of beacons: 5J and 15J Xenon strobe, multifunction LED, 20/25W and 35/40W rotating halogen beacon
- 45 alarm tones (UKOOA/PFEER compliant)
- 3 stage alarm option
- Volume control
- Automatic sounder synchronisation on multi-unit systems
- Beacon manufactured from UV stabilised polycarbonate
- IP65
- The sounder and beacon can also be connected separately
|
|
|
|