SILVYN® LCC-2
Protection against liquids; Tensile strength; Highly compreshion proofed; Highly flexible; For higher mechanical stress
Application range
Mechanical engineering
Plant engineering and construction
Outdoors application
Everywhere where liquids are in the environment
applications with mechanical stress
Design
Spirally wounded metal protective conduit with roughenged profile
PVC outer sheath
|
|
|
|
|
|
NORDUC® tubes and connectors
The NORRES corrugated plastic protection tubes, NORDUC®, are highly flexible and liquid tight.
Applications
- for electrical installations, installation in switchboard plant, switch cabinets, mechanical engineering and robotics
- as suction and pressure hose for gaseous and liquid media
- for hydraulic and pneumatic hoses
- for moving machine parts
Properties
- highly flexible
- gas and liquid tight
- good resistance to alkalis and acids
- good resistance to UV and ozone
- kink-proof
- approved to UL94 (flame-retardant), partically up to fire class V0
- easy to cut through
- also available in large diameters
IP 68 to EN/ IEC 60529
Temperature Range
from -40 °C up to +135 °C (short time +150 °C approx.)
Construction and material
- corrugated full plastic tube; wall: high grade polyamide, polypropylene (PPmod) or polyurethane
Connectors
Our one-piece NORDUC® connectors are quick and easy to fit. They are vibration resistant and also available in stock in large diameters.
|
|
PMA AG offers more than 25 different conduit types for a variety of applications in cable protection. The PMAFLEX range offers conduits for technically demanding applications and special requirements.
Conduit sizes range from 4.5 mm to 125 mm diameters, from lightweight to heavyweight and pliable to highly flexible. Standard colours are black and grey.
Many conduits are specially approved, e.g. CSA, UL Recognition, NF, SNCF, DB etc.
|
|
Suitable for the protection of the cables for wall or floor application. High resistance to compression and crushes. ICTA code is manufactured in Halogen Free Low smoke materials and code TF1 for standard application. They all meet the EN 50086.2.2 Standards prescriptions.
|
|
Protective conduits for cables and accessories are available for temperatures from -60°C up to + 230°C, for protection class up to IP 69K, they are resistant to solvents, liquid-tight, or with a silicone cover. You will find conduits in the mechanical engineering and equipment manufacturing, in automation, in power stations, or in the automotive and railway industry. They keep electromagnetic impacts away from data lines, they protect cables against physical impacts, or they guarantee easy sterilizability for tools and instruments in the medical sector.
- Protective metal conduit not liquid-tight
- EMC protective conduits
- Protective metal conduit liquid-tight
- Synthetic protective conduits liquid-tight
|
|
The Reiku flexible sheathes, made of polyamide, complete Brevetti Stendalto's specific products range for the dynamic cable protection.
Thanks to their high strength and flexibility, the Reiku sheathes are reliable and easy setting up solutions, for chemical, thermic and mechanical agents cable protection, along with their wide accessory range.
|
|
PVC flexible sheath with reinforced plastic spiral for a high resistance to flexion Meets UL 94 and EN 50086.2.3. Standards prescriptions.
|
|
|
Protective conduits for cables and accessories are available for temperatures from -60°C up to + 230°C, for protection class up to IP 69K, they are resistant to solvents, liquid-tight, or with a silicone cover. You will find conduits in the mechanical engineering and equipment manufacturing, in automation, in power stations, or in the automotive and railway industry. They keep electromagnetic impacts away from data lines, they protect cables against physical impacts, or they guarantee easy sterilizability for tools and instruments in the medical sector.
|
|
|
Protective conduits for cables and accessories are available for temperatures from -60°C up to + 230°C, for protection class up to IP 69K, they are resistant to solvents, liquid-tight, or with a silicone cover. You will find conduits in the mechanical engineering and equipment manufacturing, in automation, in power stations, or in the automotive and railway industry. They keep electromagnetic mpacts away from data lines, they protect cables against physical impacts, or they guarantee easy sterilizability for tools and instruments in the medical sector.
|
|
These divisible connectors are suitable for repairs or where cable protection systems have to be installed after wiring.
The divisible connectors in connection with the divisible conduits and divisible lock nuts are responsible for the highest possible mounting flexibility.
|
|
A complete range of mechanical tubing protection with track system,
to resolve rubbing, scraping, twisting, oil projection or any other products.
ZIPPER TECHNIK it's a adaptable solution with matter like PVC, vinyl-coated PET-cloth , flame-retardant polyurethane ...
|
|
Spiralwrap
Spiralwrap provides necessary cable routing and protection when flexibility around corners and bends is desirable. Spiralwrap is a protective sheath which is wrapped around a group of cables to shield, organize and control it. Offered in many sizes and colors, Spiralwrap is very flexible and adaptable to any telecom closet, network or office environment. The inner edges are beveled to prevent damage to cables. U.L. recognized, HellermannTyton spiral wrap is reusable and resistant to most chemicals.
|
|
|
|
|
|
* Flex IPCX neutral 3321 SUPERLUB® :
APPLICATIONS Where an higher mechanical resistance is required. It can be embedded under the floor, under plaster, in the ceiling.
MATERIAL PVC
COLOR Neutral
QUALITY MARKS IMQ, VDE
STANDARDS CEI EN 50086-1
CEI EN 50086-2-2
COMPRESSION RESISTANCE Class 3 medium (higher than 750N on 5 cm. at +20°C)
IMPACT RESISTENCE Class 3, medium (2 joule at -5°C)
MINIMUM TEMPERATURE RANGE Class 2 (-5°C)
MAXIMUM TEMPERATURE RANGE Class 1 ( 60°C)
* Flex IPC blue 3321 SUPERLUB® :
APPLICATIONS Where an higher mechanical resistance is required. It can be embedded under the floor, under plaster, in the ceiling.
MATERIAL PVC
QUALITY MARKS IMQ, VDE
STANDARDS CEI EN 50086-1
CEI EN 50086-2-2
COMPRESSION RESISTANCE Class 3 medium (higher than 750N on 5 cm. at 20°C)
IMPACT RESISTENCE Class 3, medium (2 joule at -5°C)
MINIMUM TEMPERATURE RANGE Class 2 (-5°C)
MAXIMUM TEMPERATURE RANGE Class 1 ( 60°C)
* Flex IPCN black 3321 SUPERLUB® :
APPLICATIONS Where an higher mechanical resistance is required. It can be embedded under the floor, under plaster, in the ceiling.
MATERIAL PVC
COLOR Black
QUALITY MARKS IMQ, VDE
STANDARDS CEI EN 50086-1
CEI EN 50086-2-2
COMPRESSION RESISTANCE Class 3 medium (higher than 750N on 5 cm. at 20°C)
IMPACT RESISTENCE Class 3, medium (2 joule at -5°C)
MINIMUM TEMPERATURE RANGE Class 2 (-5°C)
MAXIMUM TEMPERATURE RANGE Class 1 ( 60°C)
|
|
|
Spiralwrap provides necessary cable routing and protection when flexibility around corners and bends is desirable. Spiralwrap is a protective sheath which is wrapped around a group of cables to shield, organize and control it. Offered in many sizes and colors, Spiralwrap is very flexible and adaptable to any telecom closet, network or office environment. The inner edges are beveled to prevent damage to cables. U.L. recognized, HellermannTyton spiral wrap is reusable and resistant to most chemicals.
|
|
A large and full range of solutions with track system,
to resolve EMI/RFI problems.
"Shielded" ZIPPER-TECHNIK is a quick, effective and economical way to solve many interference problems which require shielding to reduce the effects of EMI/RFI especially in wire and cable applications.
Most standard ZIPPER-TECHNIK Jacket materials can be combined with a choice of shielding materials (laminated or sewn inside), to provide a versatile shielding system to meet or exceed almost any requirement.
All ZIPPER-TECHNIK shielding includes a patented, 360° shielding and grounding construction.
|
|
Electrician Supplies
Making sure electricians, installation technicians and contractors are equipped with the tools they need to do their job efficiently and safely is a fundamental goal of
Thomas & Betts. That's why we offer a wide assortment of the highest quality hand tools, wire connectors, fishtape, lubricants, and other essential everyday supplies for electrical construction, installation, and maintenance.
|
|
Material : High Quality Polyamide6
Construction : Inside & Outside Corrugated all Plastic Hose
Protective : IP 68 acc.EN60529
Temperature Range : -40°C to +105°C
Short Term : up to +130°C
Self-Extinguishing : UL94-Vo, Halogen-Free
Color : Black & Grey
Connections : CPSFIX
Application : Machine tool, Plant Construction, Crane and Heavy machine
International Specification : VDE, CE, UL
Productions :
CPS flexible conduit - Polyamide 6, UL94-HB, Standard
PAH flexible conduit - Polyamide 6, UL94-Vo, Non flame
POH flexible conduit - Polyamide 6, UL94-Vo, Non flame, Strong structure
PAR flexible conduit - Polyamide 12, UL94-V2, Ultra flexible
PES flexible conduit - Polyethylene, Resistant to Acid, Alkali
PPS flexible conduit - Polypropylene, Resistant to Acid, Alkali
Dimension range :
Outer diameter - 10, 13, 15.8, 21.2, 28.5, 34.5, 42.5, 54.5, 67.2, 82.5, 106
|
|
SUPERLUB® The internal lubricated surface makes easier to thread the cables, reduces the friction, overpasses the obstacles, avoid abrasion, crack and damages to electric wires.
APPLICATIONS
Where an higher mechanical resistance is required. It can be embedded under the floor, under plaster, in the ceiling.
|
|
Smooth inside, corrugated outside, double walled, protectiveunderground, large diameters conduits.
APPLICATIONS For cable conduits underground. Their flexibility an mechanical resistance allows installation even in the presence of irregularity of the ground.
MATERIAL HD, polyethylene high density.
High chemical and water resistance
COLOR Red.
Available also in green, yellow, black an blue on request with a minimum quantity of 2000m. per size/colour.
QUALITY MARKS NF-USE
STANDARDS CEI EN 50086-1
CEI EN 50086-2-4 (type N)
COMPRESSION RESISTANCE Higher than 450N on 5 cm. at +20°C
IMPACT RESISTENCE Type N (normal) at -5°C
3kg/h = variable with the size.
|
|
Heyco-Flex II Liquid Tight Tubing
Flexible, Nonmetallic Liquid Tight Electrical Tubing
1/4" thru 2" trade sizes.
Use with nylon Heyco-Flex Connectors: Snap-In. Straight or Sweep.
May also be used with Heyco Die Cast Metal Rttings tor Liquid Tight Tubing.
Resists corrosion, oil, and water.
Maximum flexibility, can be used in extremely tight quarters.
Temperature rating 70°C (1608F).
Smooth inside tor easier wire pulling.
Lightweight and lower installed cosL
Quick installation; cuts with utility knife, PVC cutter or Heyco cutting tool (#8340).
Integral rigid and flexible PVC construction.
Ideal tor fiber optic cable protection.
Suitable tor use in high vibration or flexing applications: Automotive Equipment, Computers and Peripherals, Fiber Optics, Lab Equipment Lasers, Office Equipment, Processing Control and Monitoring Equipment, Robotics, White Goods
Passes submersion testof70psi.
Mounting Brackets are available.
|
|
|
|
|
|
Adaptaflex have a choice of fifteen individual metallic conduit systems manufactured either in galvanized steel or stainless steel.
A range of 3 different conduit types provide a solution for liquid resistant specifications with a further 3 conduit options in liquid tight covered steel conduit for especially demanding environments. Conduit ranges are offered in nominal conduit size from 3mm for CCTV/roller shutter doors and for protecting fibre optics cables right up to 75mm for larger cable carrying capacity.
Overbraided conduits are particularly suitable for installation in abrasive environments. Where applications call for enhanced low fire hazard properties or EMI screening then there is the option of high specification tinned copper overbraided for greater EMI protection levels.
In addition a range of fittings are specifically designed to maintain system integrity including fixed and swivel fittings, straights, 90°, 45°, and a host of accessories including locknuts, enlargers, reducers and converters. Many of our conduit systems have industry recognised approvals including British Kitemark, CE Approval, UL Listing, NF, LUL, DB, and Lloyds Register amongst others.
Advantages
High compression/crush strength
Tensile strength - pull off load under tension
Impact resistance
Inherent fire protection on uncoated versions
Corrosion resistant - stainless steel options
Braided - High level EMI screening with tinned copper overbraided
Greater temperature tolerances
|
|
|
|
|
|
Heyco-Flex I Liquid Tight Conduit
Flexible, Nonmetallic Liquid Tight Electrical Conduit
3/8" thru 2" trade sizes.
Use with nylon Heyco-Flex Connectors: Snap-in. Straight or Sweep.
Mayalso be used with Heyco's Die Cast Fittings tor Liquid Tight Conduit.
Resists corrosion, abrasion, oil. water, acid, metal shavings, and rough environments.
Resists abuse, pull, and crushing.
Temperature ratings: 80°C (203°F) DRY; 70°C (160°F) OIL Resistance 60X (140°F) WET locations
Passes submersion testot70 psi.
Mounting Brackets are available.
Smooth inside tor easier wire pulling: no hazardous sharp edges or burrs: will not damage conductors.
Lightweight and lower installed cost.
Quick installation; cuts with utility knite, PC cutter or Heyco cutting tool (#8340).
Integral rigid and flexible PC construction.
Suitable tor indoor/outdoor use: HVAC Equipment. Machine Tools. Marine Equipment. Motors and Controls. Printing Equipment. Pumps. Refrigeration Equipment
Approved for direct burial.
Order Part No. 8340. VF-28 Cutting Tool, for cutting Heyco-Flex conduit and tubing cleanly and evenly.
|
|
Straight Swivel Fitting - External thread
Type: M - SPL, SPLHC & SPUL
Description: For insertion into threaded entries & knockouts.
Material: Nickel plated brass
IP Ratings: IP66, IP67, IP68, IP69k
Part No Size Colour
SPL10/M12/M 10_mm Silver
SPL10/PG7/M 10_mm Silver
SPL12/M16/M 12_mm Silver
SPL12/PG9/M 12_mm Silver
|
|
Fibre Winding and Storage Reel
Multi-Position Array Tray
Polishing Puck
Flat Tie Holder
Richco Kwik Wrap, on Base, adhesive, Identification
Optical Fibre Duplex Splitter
Wire Saddle Locking Top and Quarter-Turn Base
Extruded Flat Cable Clamp
Extruded Flat Cable Clamp with Silicone Foam
Extruded Wire Harness Clip
Adjustable and Plug In Kwik Klip
Continuous Grommet Strip, w/Adhesive, Metal
Slit Harness Wrap and CAT Installation Tool
Richflex Flexible Channel
|
|
The distribution systems allow for orderly laying and branching of cable looms. Various types with various protection classes.
Type SVG
Extension and repair of cable protection conduits.
Easy assembly by latching
Split version makes routing of cables easy
Can also be screwed on
Type VT
T distributor for cable protection conduits with different diameters.
Easy assembly by latching
Split version makes routing of cables easy
Distributor envelops the conduit, which means that the entire inside diameter of the conduit is available
Type SVY
Y distributor for cable protection conduits with different diameters.
Easy assembly by latching
Split version makes routing of cables easy
Distributor envelops the conduit, which means that the entire inside diameter of the conduit is available
|
|
Jacketing materials Fibreglass with Aluminium or Silicon coating.
Small, medium and big prototype set possible.
Heat protective action is not limited to cables, tubing and pipes alone.
Component application's often calls for specific forms and shapes with different closure and wrap methods.
Standard fabrication tubular: Snap-button, Hook and loop or sewed track system.
Customized protection possible.
|
|
Straight Fitting - Fixed External Thread
Type: A - Adaptaseal
Description : For insertion into threaded entries & knockouts. Locknut supplied with METRIC THREAD ONLY
Material: Polyamide (Nylon) 66
IP Ratings: IP66, IP67, IP68, IP69k
|
|
Flexicon Nylon Straight NPT Thread Fittings
For use with 16 mm Ihru 67 mm Flexicon corrugated conduit/tubing.
Seven NPT threaded choices for use with seven different conduit sizes.
Suitable for use with both fine and/or coarse pitch conduit/tubing.
Unitary design and assembled shipment allows fast fit.
All nylon construction resists saltwater, weak acids, gasoline, alcohol, oil, grease, and common solvents. This feature is not assessed by UL certification or testing.
No threading of the conduit/tubing is required to install.
Locknuts NOT included, click here for Nylon Locknuts.
Suitable for use by all original equipment manufacturers.
Protection class IP 66 per EN 60529 including high pressure water jet from any angle.
Vibration and tamper resistant but easily removable with use of electricians screw driver.
Click here for NPT thread specifications & IP Rating.
Consult factory for FPAX finings for use in IP 68 or 67 (as well as 66) applications.
|
|
Conduit & Cable Fittings
Thomas & Betts offers one-stop-shopping for electrical conduit and fittings with a portfolio of leading brand names -- Ocal®, Red Dot®, Steel City®, Shureseal, T&B®, Shamrock®. Whether for hazardous location applications, such as an oilrig or refinery, heavy-duty applications such as manufacturing or transportation, or light-duty applications such as hospitals or hotels, you can count on the brands of Thomas & Betts for dependable, quality assurance.
|
|
| ... products without technical information |
| |
|
|