Primary voltage: 420 kV
Secondary voltage: 36 kV - 800 kV
Primary current: 0 A - 4,000 A
... customer-tailored solutions IMB oil-minimum current transformers are based on a tank type (hairpin) design and available with porcelain or silicone rubber insulators. Hitachi ABB Power Grids current transformers ...
ABB AG
Primary voltage: 36 kV - 800 kV
Primary current: 4,000 A
... customer-tailored solutions IMB oil-minimum current transformers are based on a tank type (hairpin) design and available with porcelain or silicone rubber insulators. Hitachi Energy current transformers ...
Hitachi Energy
Primary voltage: 72 kV - 800 kV
... performance and reliability Capacitor Voltage Transformer CPB is designed for revenue metering and protection in high voltage networks. It is of single-phase design and intended for connection between phase and ground ...
Hitachi Energy
Output power kVA: 500, 167 kVA
Primary voltage: 72.5 kV - 550 kV
Secondary voltage: 48, 36, 690 V
... voltage transformer combines the characteristics of a voltage transformer with the capability of a distribution transformer, having an output sufficient for smaller auxiliary loads. Hitachi ...
Hitachi Energy
Output power kVA: 1.5 kVA
Primary voltage: 230 V
Secondary voltage: 230 V
... RS PRO portable isolation transformer can be used to isolate a standard European 230 V mains voltage supply. It has a high-quality design that’s light, robust and is made with your safety in mind. The separating transformer ...
Electric power: 0 W - 300,000,000 W
Primary voltage: 0 V - 2,000 V
Primary current: 180,000 A
... requirements to modern converter transformers. Find out in our exclusive whitepaper how you can specify your converter transformers to enhance your system stability while saving costs at the same time. ...
Siemens High-voltage – Power transmission
Electric power: 0.5 kVA - 5 kVA
Primary current: 1.36 A - 12.86 A
Transformers have to be flexible because different situations require different voltages. Murrelektronik's product range offers this flexibility, no matter if it's an isolation transformer, control transformer, ...
Electric power: 3,600, 7,000, 2,000 W
Primary voltage: 115, 230 V
Secondary voltage: 115, 230 V
Indispensable in professional marine energy systems. It prevents electrolytic corrosion and above all serves as a device to guarantee a safe electric system. Toroidal wound technology for quietness and high efficiency. Soft start circuitry ...
Electric power: 252 W - 5,500 W
Output power kVA: 100 kVA - 3,150 kVA
This kind of transformer complies with EU Ecodesign Direc- tive (EU548/2014) and with the IEC 60076-11:2018-10 standard. It makes it possible to reduce energy consumption and, as a consequence, to reduce greenhouse emissions. ...
Tesar Srl
Output power kVA: 100 kVA - 20,000 kVA
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
... Compared to the existing EcoDesign Tier2 Transformers set by the European Community, EcoPlus2030 Transformers boast significantly reduced CO2 emissions and losses. Just like the olive tree, our EcoPlus2030 ...
Tesar Srl
Frequency: 60, 50 Hz
... of cast resin transformers mainly used for energization of rails, metros, highspeed trains, tram- ways, braking energy recovery systems and auxiliary services for sta- tions and signalling. The range of production includes ...
Tesar Srl
Output power kVA: 0.63 kVA - 1,000 kVA
Primary voltage: 800 V
Secondary voltage: 400 V
Dry type transformer. All transformers are tropicalized with anti-flash varnish: • Protection against corrosive environments. • Greater electrical insulation. • High compaction power. • Noise level reduction. • ...
POLYLUX S.L.
Output power kVA: 0.63 kVA - 1,000 kVA
Primary voltage: 800 V
Secondary voltage: 400 V
Dry type transformer. All transformers are tropicalized with anti-flash varnish: • Protection against corrosive environments. • Greater electrical insulation. • High compaction power. • Noise level ...
POLYLUX S.L.
Output power kVA: 3.15 kVA - 50 kVA
Primary voltage: 230 V
Secondary voltage: 230 V
Dry type transformer Anti-flash varnish finish, offering: • Protection against corrosive environments • Increase of electrical isolation • High compression capacity • Reduction of noise level • Increase of product's ...
POLYLUX S.L.
Output power kVA: 25 kVA - 3,150 kVA
Primary voltage: 7.2 kV - 36 kV
Frequency: 50, 60 Hz
... distribution oil conservator Transformers • MV / MV oil immersed Transformers • LV / LV dry-type or oil immersed Transformers • Special transformers • Reactors • ...
Electric power: 0.5 kVA - 160 kVA
Three-phase Transformers designed and manufactured to comply with IEC61558 and IEC60076. These are double-wound Isolation Transformers for continuous duty and complete with earth screen between the primary ...
Electric power: 3 kVA - 40 kVA
Primary voltage: 230, 415 V
Primary current: 7.22 A - 173.91 A
Larger single-phase Transformers using UI two limb construction. The Transformers conform to IEC61558 and IEC60076 and are available with a range of voltage and connection options.
Electric power: 160 kVA - 750 kVA
Three Phase Transformers 160 - 750kVA Three-phase Transformers designed and manufactured to comply with IEC61558 and IEC60076. These are double-wound Isolation Transformers for continuous ...
Output power kVA: 25 kVA - 10,000 kVA
Primary voltage: 36 kV
Secondary voltage: 36 kV
... Type Transformers from 25 kVA up to 10.000 KVA up to 36 kV voltage class. Cast Resin Transformers are a cost-effective and convenient alternative to traditional high voltage Oil Immersed Power and Distribution ...
Timsan Transformateur
Output power kVA: 25 kVA - 8,000 kVA
Primary voltage: 36 V
Secondary voltage: 36 kV
* Cooling Type: ONAN or Customized * Vector Group: YZN, DYN or Customized * Conducting Material: Electrolytic Copper or Electrolytic Aluminum. * Geographical Conditions: Concerned country’s conditions (Altitude, Humidity, Temperature ...
Timsan Transformateur
Output power kVA: 25 kVA - 5,000 kVA
Primary voltage: 36 kV
Secondary voltage: 36 kV
* Cooling Type: ONAN or Customized * Vector Group: YZN, DYN or Customized * Conducting Material: Electrolytic Copper or Electrolytic Aluminum. * Geographical Conditions: Concerned country’s conditions (Altitude, Humidity, Temperature ...
Timsan Transformateur
Primary voltage: 110 V - 240 V
Secondary voltage: 24, 48, 110, 220 V
Secondary current: 10 A - 10,000 A
Internal isolation transformer at input, Full controlled conventional rectifier, Smart control and high reliability with DSP (Digital Signal Processor)... GENERAL SPECIFICATIONS Internal isolation transformer ...
Primary voltage: 190, 200, 380, 400, 415 V
Secondary voltage: 24, 48, 110, 220, 12 V
Secondary current: 0 A - 10,000 A
Internal isolation transformer at input, Full controlled conventional rectifier, Smart control and high reliability with DSP (Digital Signal Processor) GENERAL SPECIFICATIONS Internal isolation transformer ...
Electric power: 185 W - 3,000 W
Output power kVA: 40 kVA - 2,500 kVA
Primary voltage: 24 kV
The transformers can be available with oil expansion tank or hermetic version , and they are designed and manufactured according the following standards and equipped by the following accessories: • CEI EN 60076-1:2015 ...
Electric power: 252 W - 3,420 W
Output power kVA: 100 kVA - 3,150 kVA
Primary voltage: 24 kV
The transformers are designed and manufactured according the following standards and equipped by the following accessories: CEI EN 60076-11 : 2019 ( EN 60076- 11 : 2018 – IEC 60076-11 : 2018 ) CEI EN 50588-1 : 2018 ...
Primary voltage: 1.1 kV - 132 kV
... product range by adding: • Earth transformer • Rectifier Transformers & Cyclo-converter Transformers • Power Reactors & Shunt Reactors • Step regulating glass furnaces Transformers ...
Output power kVA: 30 kVA - 2,500 kVA
The amorphous alloy dry-type transformer uses amorphous alloy as the core material, and the coil is cast with epoxy resin. The product has good fire resistance, moisture resistance, no pollution, flame retardant, self-extinguishing ...
Primary voltage: 132 kV
Secondary voltage: 3.3 kV - 66 kV
Frequency: 50, 60 Hz
These are basically step-down transformers reducing transmission/sub-transmission voltage to primary feeder level. Standard Fittings Primary bushings Secondary bushings Off circuit tap changer Pressure relief ...
Output power kVA: 10,000, 5,000 kVA
Primary voltage: 36 kV
... base. Transformers for wind turbine applications will be made up to 5MVA and 36kV voltage class. EARTHING TRANSFORMERS: An earthing transformer is a type of auxiliary transformer ...
Elektrotechnik's controllable transformer is a ready-to-connect power supply solution. This transformer aids in providing a power supply either as a 24V control voltage or 8000 V anode voltage. The manufacturer ...
J. Schneider Elektrotechnik
... C02 emissions. Its distribution transformer or converter transformer works on the lowest possible core losses overall. The company also manufacture oil-insulated transformers, as ...
J. Schneider Elektrotechnik
Electric power: 34,000,000 W
Primary voltage: 10,000 V
J. Schneider presents starter transformer designed for compressor motors in air separation plants. It has a nominal voltage of 10 kV and can generate 34 megawatt. J. Schneider provides optimized power supply solutions ...
J. Schneider Elektrotechnik
These ASR/ASK measuring transformers belong to DEIF's current transformer range. This type of transformer converts high current to a lower nominal current value, hence allowing the use ...
Protection transformer - SASR/SASK The protection transformers of DEIF are utilized in balanced protection systems for over current and earth fault protection. 15 different physical sizes of the ...
The Switchgear KSU/SUSK is a summation transformer used to recap the secondary currents. The secondary currents are re-caped to a common secondary signal. This device is equipped with a housing that is constructed of ...
Primary voltage: 21,400 V
Primary current: 600 A - 1,000 A
Frequency: 50 Hz
Downstream of the HVB/HVA transformer, compensation impedances equip MV networks with neutral point connection (aerial-underground rural networks). Developed as part of the Enedis MALTEN project and installed in source ...
Cahors
Output power kVA: 7,500 kVA
Primary voltage: 69 kV
... distribution transformers to support a variety of applications. Our product lines include pole- and pad-mounted, single- and three-phase solutions, as well as primary and secondary substation transformers, ...
GE Grid Solutions
Electric power: 0.1 W - 3.2 W
Primary voltage: 208 V - 600 V
Secondary voltage: 24 V - 230 V
General Data Rated input voltage 208 ‑ 600 Vac Rated output voltage 24 ‑ 230 Vac Rated power 100 ‑ 3200 VA Insulation class B Maximum ambient temperature 40 °C Efficiency up to 96 % Degree of protection IP 00 Advantages Universal input ...
Primary current: 300 A - 3,000 A
Current transformers for low-voltage network Protection Single-phase current transformer Passing bus bar primary Primary current 300...2500A Secondary current 1 - 5A Accuracy class: 5P5 - 5P10 ...
IME Spa
The head type IOSK oil paper insulated current transformers follows the current IEC and IEEE/ANSI standards. It is outstanding in controlling insulation stress using fine graded bushing. The advantages of using fine graded ...
Trench Group
Electric power: 30,000 kVA - 1,000,000 kVA
The generator step up transformer, manufactured by Avantha, is suitable for producing distribution transformer that ranges from 30 mVA up to 1000 mVa ranges with a maximum 765 KV for both voltage sides ...
CG Power Systems
Electric power: 0.01 kVA - 31.5 kVA
This TRT 33 power isolating transformer is a dry type transformer. The transformer is meant for voltage changes with galvanic isolation whenever it is necessary to change the neutral ...
Electric power: 7.5 kVA - 440 kVA
Primary voltage: 460 V - 575 V
Secondary voltage: 133 V - 460 V
... SCR (Silicon Control Rectifier) variable speed motor drive applications, a transformer is needed to magnetically isolate the incoming line from the motor drive. The transformer must also provide a voltage ...
SolaHD
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining