Maximum measurement accuracy ensures absolute safety, control and reliability in liquid handling - be it manual, automatical or computerized.
nutating disc type flowmeter. For portable use with FLUX barrel and container pumps or fixed installation into pipework. Suitable for liquids up to 2.500 mPas (cP). |
|
Cost Effective
- Eliminates upstream and downstream straight run piping
requirements
- Power not required for mechanical version
Rugged, Reliable Design
- Tolerant of foreign particles
Saves Space
- Very compact size |
|
| Rotary piston gas meters have been manufactured since 1930 by Aerzener Maschinenfabrik, one of the largest and oldest manufacturers worldwide. The basis for the design of the gas meter series is from many years of experience and continual dialogue with the end users, as well as using the harmonized EU-standards which will apply to all installations within the European Market. They are manufactured in accordance wiht the Aerzen tradition for quality corresponding to the quality assurance system, certified to DIN ISO 9001 and as per pressure device guideline DGRL 97/23/EG. |
|
| for volume measurement of gases in various types of construction an sizes. Gas meter sizes from G 40 up to G 4000 for gas volume flow measurement from 0,65 m³/h - 6.500 m³/h. Measuring pressures up to 25 bar. Works tested or officially calibrated as per national and EU-directives. |
|
Liquid Meters Type FMO
Oval rotor type flowmeter in 7 model sizes for flowrates of 0,1 to 350 l/min and viscosities up to 500.000 mPas (cP). |
|
Measuring the volume flow rate of liquids and liquefied gases and in loading systems in the chemical and petrochemical industry, in the mineral oil industry, in the food and beverage industry.
Oval Wheel Meter Series OV
DN 80 - 100
PN 16
flow rates 2,4 - 200 m³/h
accuracy ± 0,3 %
operating temperature according to design -10°C to 60°C
for custody transfer admitted
Oval Wheel Meter Flowal
G 1/2"
PN 16
for small flow rates 0,2 - 10 l/min
accuracy ± 1 - 2 %
operating temperature according to design -10°C to 80°C
|
|
Measuring liquids and liquefied gases in the chemical and petrochemical industrie, in the mineral oil industry, in the food and beverage industry and loading systems, especially for high operating temperatures and low viscosities.
Turbine Meter RQ Series 1
DN 10 - 65
PN 16 - 320
flow rates 0,15 - 120 m³/h
accuracy ± 0,15 % over a reduced flow range ( for viscosities of 0,2 %u2013 0,7 mPas )
accuracy ± 0,25 - 0,3 for the standard - flow range ( for viscosities of 0,2 %u2013 0,7 mPas )
operating temperature according to design -196°C to 250°C
for custody transfer admitted
|
|
Versatile
- Models 122 & 123 display continuous totalization
- Models 413, 433, & 444 display continuous totalization
and provide a calibrated contact closure
- Models 420 & 421 display continuous totalization with
the option of adding the 840 calibrated contact closure
and/or the 860 calibrated digital pulse signal without
removing the flowmeter from the line.
Durable
- Sealed register prevents condensation or fogging
- One internal moving part
- Multi-jet design ensures balanced forces and extends
meter life |
|
The Webster DHM 3 Series Digital Hydraulic Multimeter is an all-in-one unit designed to test the performance of hydraulic pumps, motors, valves and hydrostatic transmissions.
The easy-to-use design allows the operator to just switch on and test, without complex setup or special training.
The DHM measures flow, pressure and temperature. In addition, the DHM holds the peak pressure value as well as calculating hydraulic power and volumetric efficiency using the unique P-Q test button.
The DHM is the ideal tool for pinpointing hydraulic system faults, reducing downtime, and helping in preventative maintenance. The design builds on the very successful Webster DHT range of portable testers with the addition of a large digital display and a built-in pressure transducer.
The turbine flow meter with built-in loading valve is bi-directional and specifically designed to enable the operator to simulate the maximum working pressure safely during normal machine operation.
The loading valve has safety discs built-in to protect the operator and the multimeter in the event of excessive pressure, allowing oil to bypass the loading valve INTERNALLY with no spillage of oil from the hydraulic circuit, eliminating any danger to the operator or environmental hazards.
|
|
The V2 System Flow Meter has an advanced differential pressure flow sensing design. The unit features built-in flow conditioning for superior accuracy. The V2 System is the ideal new or retrofit flow meter for multiple clean water and wastewater treatment applications.
The V2 System is especially useful when irregular or crowded piping and equipment make magnetic, turbine or venturi tube meters impractical or unworkable. Other flow technologies often require complex or expensive construction. The V2 System reduces initial costs substantially. The unit eliminates longer straight-run piping requirements.
V2 System’s pre-packaged, built-in 3-way valve isolates the transmitter from the process fluid flow for easy maintenance. No need to shut down the pipeline. The flow meter arrives wet-flow calibrated direct from the factory. The ready-to-install V2 reduces many headaches of adding a flow meter to most flow installations.
Key features include:
Installation: 0-3 diameters
upstream; 0-1 diameter downstream
Acts as its own flow conditioner
Displays rate of flow and total flow
Integral or remote mounted flow display
Accuracy up to /-1% of rate
Flow range: 10:1
Totalizer pulse and linear 4-20 mAdc
outputs
Low Maintenance
Lines 4-18 inches or greater
|
|
Suitable for harsh environments and more sophisticated outputs either ABS or Aluminium.
Features:
- Easy to set (MENU);
- Analogue output 4-20 mA;
- RS 485 output (insulated);
- Pulse and alarm ON/OFF output;
- Bi-directional flowrate reading;
- Measurement frequency 10/20 Hz;
- Metric system (SI, UK, US);
- Input for connection of TRM 100 programmer;
- Power supply: 90...264 Vac 50-60 Hz or 24 Vac/dc 50-60 Hz;
- Keyboard;
- 2 lines 16 characters display;
- Batching function; batching alarm
- Low consumption operating mode;
- Empty pipe alarm (*);
- Alarm min and max flowrate;
- Alarm full scale change and reverse flow;
- Modbus protocol (*) ;
- Digital input for totalizer remote reset or batching start/stop; |
|
RITTER drum-type gas meters are universally applicable for measuring the volume of flowing gases and are particularly effective when measurements demand the highest precision.
The major advantage and the superiority of volumetric Gas Meters (like Drum-type Gas Meters) over other measurement principles, which determine gas volume using secondary measurable variables such as speed, heat capacity, hot-wire resistance or similar, is that the volume is directly measured. That means that the condition and the composition of the gas has no influence on the measurement accuracy. |
|
The helical screw flowmeter is a high precision meter giving excellent reliability. It is mainly used for viscous fluids but will also perform well on low viscosity fluids. The basic range of meters are in aluminium or grey cast iron and stainless steel models are available. Flow rates range from 0.1 l/min to 7,500 l/min.
Suitable for wide ranges of viscosity these meters provide high accuracey measurement (+/-0.1%) for fuel and oil flows particularly for automotive and aviation test rig applications. |
|
Litre Meter developed the Pelton wheel principle as the best to achieve accurate measurements of low flows.
A single turbine ring size is common to all Litre Meter flowmeters. The turbine rotor is based on a highly efficient 'Pelton Wheel' design. It is available in various chemically resistant materials such as PFA (Teflon)and PVDF. The rotor ferrites are sealed to make them non-wetted parts. Sapphire bearings are offered for maximum chemical resistance as standard. These provide a very low friction mechanically-robust bearing with long life characteristics.
The rotation of the rotor is sensed by an electronic system using the interaction of ferrites in the rotor tips with a pickup coil. No drag is imposed on the rotor which assists in the measurement of extremely low flows. This, coupled with the efficient Pelton Wheel design and low friction bearings gives the meter major advantages. The complete turbine ring assembly can be easily removed with the meter remaining in line if cleaning is required.
|
|
Chemical injection fluids are normally viscous and are therefore natural applications for the VFF meter. The flowrates are relatively low and the pressure is high compared to most general industrial applications. The VFF Rotary meter is the ideal measuring element for these service requirements. Long term stability of metering and reliability is assured by the basic simplicity of design and quality of production.
VFF Meter Design & Advantages
The heart of the VFF meter is a simple but precisely made, oscillating rotor that sits freely within the rotor chamber of the meter. It is manufactured in a variety of materials. The meter principle is of 'positive displacement'. The rotor is driven 'positively' by the flow, which passes through the flowmeter in 'discrete pockets' with minimum fluid 'slippage'. This gives inherently greater accuracy than is available from axial flow turbine type meters for a low flow of a fluid more viscous than water. Each meter provides a exceptionally wide flowrange and has excellent low flow metering capability. |
|
These meters are mainly used for viscous fluids for flow rates of less than 8 l/min. We specialise in low flow metering noting that the meters will return a rangeability of 1000:1 for most viscous fluids applications. Materials are 316 stainless steel with a variety of rotor materials. We can measure from 0.00016 to 1750 l/min. (and up to 4000bar)
The VFF range of meters are specificaly designed for very low flow (0.0003l/min), high pressure (2000bar) hazardous area (Ateax approved) applications. They have been in service for over 15 years in the UK North sea oil and gas industry for chemical injection applications. |
|
| The Litre Meter pelton wheel flowmeter was first patented in 1975 and has an established reputation for function and reliability. Flows from 0.004 l/min can be metered up to 28 l/min using our LM series range. Large flowmeters are provided utilising the orifice/bypass principle where a wide flow range is given and the ability to measure low flows is retained. Pelton Wheel flowmeters are suitable for low viscosity clean fluids with variants in all- PFA Teflon for maximum chemical resistance and high pressure types to 2000 bar at the other end of the spectrum. |
|
Hybrid
Blue-White introduces Sonic-ProTM Hybrid Ultrasonic Flowmeters.
Sonic-Pro has the ability to measure fluid flow using either Doppler or Transit Time methods. Additional features include: Non invasive clamp-on transducers; Custom metric algorithms and DSP technology ensures reliable, accurate measurement; easy reading LCD; data is logged to a standard SD card format supplied with each unit; isolated 4-20 mA output is fully configurable; 0 - 1000Hz Pulse Output is fully configurable; computer connection permits remote access to, and control of, all functions including: real time display, system configuration, data logging, remote data capture and process control functions. Sonic-Pro is IP66. |
|
Fluids: Gas, Steam, Liquids
Diameters of pipes/ channels:
0..20 mm deltaflow DF8
15..100mm deltaflow DF10M
65..3000mm deltaflow DF25
500..15000mm deltaflow DF50
Operating conditions:
-250..1240 °C
0..800 bar
Pure to extremely contaminated, aggressive media
Eexia
TRD
The deltaflow flometer is continiously developed and inprooved and we hold several patents on the deltaflow Technology. But we do not only rely on our own know-how %u2013 systec is furthermore co-operating with well known partners sich as the institute for flow mechanics of the University of Erlangen oder the PtB in Braunschweig.
Due to the special probe profile the deltaflow can assure a high level of precision and excellent process viability, even in extreme conditions causing the lowest residual pressure loss. The deltaflow has been installed several thousand times.
Typical Applications are flow measurement of steam, perssurized air, water, liquids, stack gas, flare gas, natural gas.
Typical industries where our deltaflow integrating pitot tubes are used are Power Plants, Chemistry, Petrochemistry, Gas- and Oil Exploration, waste water plants.
The program to size and design the deltaflow is very self-explanatory and you can download it for free from our web-page as a Windows file (Windows 9x, 2000 and NT).
You can find more details in the referring information sheets. At the bottom of this page you can find links to the information sheets and to the software |
|
| Bronkhorst High-Tech offers the most extensive product range of thermal mass flow meters and controllers for gases and liquids on the market. Numerous styles of both standard and bespoke instruments can be offered for applications in laboratory, industrial and hazardous areas. The full scale measuring range for these instruments can be selected between 0-1 mln/min and 0-10000 m3n/h for gases and 0-30 mg/h up to 0-20 kg/h for liquids. Bronkhorst's Coriolis Mass Flow Meters/Controllers for gases and liquids have a measurement capability between 20 g/h and 600 kg/h. The most recent development is a series of ultra-compact, chip-sensor based instruments for gas flow and pressure measurement and control. |
|
| Racine Vortex offers high-accuracy vortex-shedding flow meters for a number of liquids and gases. The product line is quite unique: by incorporating ultrasonic technology, the meter's bluff body ("strut") has a considerably smaller footprint compared with other vortex-shedding flow meters. This results in very low pressure drop in the system. Meters are available in wafer (in-line, 1/2" to 4" size) or insertion styles (4" line size and higher). This vortex-shedding technology involves no moving parts, and the meters are virtually maintenance-free. Loop-powered gas flow meters offer HART communications, temperature compensation for mass flow measurement and gas flow standardization, CE-mark and optional ATEX hazardous area certification. Liquid flow meters also carry the CE mark. |
|
– Compact and slender Design
– Measuring module: plugged in from the front
– mm scale, product scale, user-defined scale
– Float: spherical shape affords stability
– Seals: FKM as standard, EPDM or Buna-N
– Valve: close-control, 15-turn microvalve
– Valve practically hysteresis-free
– Customized versions:
just request our technical advice |
|
This multi-range radial flow turbine meter uses a low inertia turbine supported on robust sapphire bearings in a chemically resistant housing. Ten flow ranges, a choice of "plug in" end connection fittings, and two styles of pulse detection system make this meter one of the most flexible available. The unit has individual traceable calibration, and can be considered as simple apparatus when placed in a hazardous area.
The unit can be configured with fittings and electrical connections to suit OEM requirements. Particular advantages include a wide flow range, long bearing life and in-line design. Output is via a pulse, which can be monitored by simple electronic systems.
|
|
SIKA positive displacement flow sensors are highly accurate transmitters that measure volume flows. They work on the positive displacement principle.
The flowing medium causes a pair of gear wheels to rotate. The sensor is manufactured to the highest accuracy and is then precisely assembled. The rotation is scanned by two non-contact pick-offs. As each tooth generates a pulse, the resolution is very high. Very low flow rates can be accurately measured and small volumes can be dosed.
The measurement unit contains two pick-offs that are circumferentially offset by ¼ of a tooth pitch to generate a 2 channel flow-proportional frequency signal. Suitable processing of the signal provides an greater resolution and the option to identify the flow direction.
It is possible to measure not only high viscosity media but also media whose viscosity varies e.g. because of changes in temperature. The maximum pressure drop should not exceed 16 bars. This limits the measurement range of high viscosity media (see pressure drop diagrams). Basically, the measurement accuracy increases with increase in viscosity of the media. |
|
The Titan oval gear flowmeters work by using the liquid pressure to drive a pair of interlocking oval gears. This rotation can be detected by a variety of means to give either a TTL or contact closure pulse output. The unit is manufactured in a choice of materials and pressure ratings to suit most applications and as with all positive displacement flowmeters, the performance improves with increasing viscosity, and can achieve an accuracy of ± 0.1% of reading.
The standard range of sizes covers from 0.25” to 2” BSPF connections, with maximum flows from 1l/min to 500 L/min depending on the model. Viscosities up to 10,000cP can be measured accurately, both in forward and reverse flow. Units are available for high pressure and temperature operation.
|
|
ISOMAG FLOWIZ is the revolutionary battery powered electromagnetic flow-meter.
- Internal GPRS modem for wireless communication through e-mail sent directly into a selected e-mail account;
- Internal Data Loggers at different sampling rates;
- Battery lasting up to 10 years;
- Possibility of powering by battery and by the main line ai the same instrument;
- Electronic adaptable to all diameters, up to DN 2000 mm for the full bore sensors and 8000 mm for the insertion ones;
- Accuracy of +/- 0.5% on the read value;
- Possibility of manage flow and pressure data;
- Perfect for Leakage Detection processes inside Water Distribution Networks;
- Supplied with software able to extract automatically data files attached in the e-mails and save them into organised folders;
- Available on request with specific software for the graphical elaboration of data from the field;
- Performances significantly better than the requirements in CEN 14154, ISO 4064 and OIML R49.
|
|
The Webster DHT 1 Series Digital Hydraulic Testers accurately measure flow, pressure and temperature. Webster testers are designed to conveniently check the performance of hydraulic pumps, motors, valves and hydrostatic transmissions.
This easy to use diagnostic tester has simplified controls and can pin-point hydraulic system faults, reducing downtime and helping in preventive maintenance. The tester comprises a turbine flow block and a large easy to read digital display which indicates both flow and temperature.
The tester has a built-in loading valve to simulate the working pressure during normal machine operation. The built-in safety discs protect the machine and operator in event of excessive pressure, allowing oil to safely bypass the loading valve INTERNALLY with no spillage of oil from the hydraulic circuit, eliminating clean-up costs and environmental hazards. |
|
| For liquid, air or gas monitoring applications, Lake's patented technology offers true bi-directional flow measurement in systems with pressures up to 6000 PSIG and flow rates up to 100 GPM. For convenient installation and maintenance, there's no straight pipe mounting or power supply required. To provide compatibility with most media, Lake's Bi-Directional Flow Meters are available in aluminum, brass and stainless steel. |
|
EE66 Series
Air Velocity Transmitter for measurement down to "0" m/s
EE66 air velocity transmitter series are designed for high accuracy measurement of lowest air velocities. It is the ideal solution for laminar flow control and special ventilation applications. The E+E thin film sensor is operating on an innovative hot film anemometer principle. This guarantees excellent accuracy for air velocity down to almost 0 m/s, which is not possible for conventional anemometers with commercial temperature sensors or NTC bead thermistors
EE66 series are available with current or voltage output, the measuring range and the response time can be selected with jumpers by the user.
Measuring range: 0...1 m/s; 0...1.5m/s; 0...2m/s (adjustable by jumpers)
Response time: typ. 4s or typ. 0.2s (adjustable by jumpers)
Outputs: 0...10 V or 4...20 mA (adjustable by jumpers)
Supply: 24V AC/DC
|
|
|