SIKA positive displacement flow sensors are highly accurate transmitters that measure volume flows. They work on the positive displacement principle.
The flowing medium causes a pair of gear wheels to rotate. The sensor is manufactured to the highest accuracy and is then precisely assembled. The rotation is scanned by two non-contact pick-offs. As each tooth generates a pulse, the resolution is very high. Very low flow rates can be accurately measured and small volumes can be dosed.
The measurement unit contains two pick-offs that are circumferentially offset by ¼ of a tooth pitch to generate a 2 channel flow-proportional frequency signal. Suitable processing of the signal provides an greater resolution and the option to identify the flow direction.
It is possible to measure not only high viscosity media but also media whose viscosity varies e.g. because of changes in temperature. The maximum pressure drop should not exceed 16 bars. This limits the measurement range of high viscosity media (see pressure drop diagrams). Basically, the measurement accuracy increases with increase in viscosity of the media.
|
|
The Titan oval gear flowmeters work by using the liquid pressure to drive a pair of interlocking oval gears. This rotation can be detected by a variety of means to give either a TTL or contact closure pulse output. The unit is manufactured in a choice of materials and pressure ratings to suit most applications and as with all positive displacement flowmeters, the performance improves with increasing viscosity, and can achieve an accuracy of ± 0.1% of reading.
The standard range of sizes covers from 0.25” to 2” BSPF connections, with maximum flows from 1l/min to 500 L/min depending on the model. Viscosities up to 10,000cP can be measured accurately, both in forward and reverse flow. Units are available for high pressure and temperature operation.
|
|
|
Basically, the VTR consists of a rotor, the housing and the measurement pick-up. The flow of fluid sets the rotor into motion.
|
|
Based on the same meshing gear principle as
the VSE series VS and VHM the Ecoflow sensor
measures viscous media, however as in-linedevice.
An integrated, magnetoresistive pick-up with PNP
or NPN-switching output produces per tooth one
impulse
|
|
The programmable flow display evaluates the pulses
from the magnetoresistive pickup and shows the
chosen units on a backlit LCD-display. Alarm and
condition reports are signalled in the display by a
red LED with additional text. The measured values
are transmitted by means of an analogue output, 0
or 4 … 20 mA, and 0 or 2 … 10 Volt by means of
a resistor (500 Ohm). The limit values are signalled
through two transistor switching outputs.
|
|
Were developed for high precision
flow metering for a wide variety of
liquids, especially liquids with high
abrasiveness and poor lubricity.
Applications include: chemical,
petrochemical, pharmaceutical and cosmetic
industry, two-component mixers,
paints, aviation.
Are dead spaced optimized for
(easy flushing) use in the paint industry
and for paint spraying systems.
|
|
The Titan oval gear flowmeters work by using the liquid pressure to drive a pair of interlocking oval gears. This rotation can be detected by a variety of means to give either a TTL or contact closure pulse output. The unit is manufactured in a choice of materials and pressure ratings to suit most applications and as with all positive displacement flowmeters, the performance improves with increasing viscosity, and can achieve an accuracy of ± 0.1% of reading.
The standard range of sizes covers from 0.25” to 2” BSPF connections, with maximum flows from 1l/min to 500 L/min depending on the model. Viscosities up to 10,000cP can be measured accurately, both in forward and reverse flow. Units are available for high pressure and temperature operation.
Units can be provided branded to customer requirements.
|
|
|
Turbine flowmeter are units designed to be precise and reliable, and can be used in many applications. VTR flow-meters can be installed even under the harhest application conditions in the oil, petrochemical and the chemical industries as well as in other industry sectors.
|
|
|
Turbine flowmeter are units designed to be precise and reliable, and can be used in many applications. VTR flow-meters can be installed even under the harhest application conditions in the oil, petrochemical and the chemical industries as well as in other industry sectors.
|
|
The pick-up system consists of one or two sensor units,
which are screwed into the cover of the VS flow meter
and of a downstream switched amplifier. This amplifier is
connected with the flow meter by means of a temperature
resistant cable and has to be installed outside the high
temperature area, where the ambient temperature should
not exceed 50°C (122°F).
|
|
Were developed for high precision
flow metering for a wide variety of
liquids, especially liquids with high
abrasiveness and poor lubricity.
Applications include: chemical,
petrochemical, pharmaceutical and cosmetic
industry, two-component mixers,
paints, aviation.
Are dead spaced optimized for
(easy flushing) use in the paint industry
and for paint spraying systems.
|
|
The rotation of the flowmeter gear wheels is sensed
by a non-contact magnetoresistive pickup, amplified
and emitted as pulses. The passing of each
individual gear tooth produces a pulse corresponding
to a precise positively displaced measured
volume. The pulse output can be produced as PNP
or NPN signals. The frequency is proportional to
the momentary flow.
|
|
The pick-up system consists of one or two sensor units,
which are screwed into the cover of the VS flow meter
and of a downstream switched amplifier. This amplifier is
connected with the flow meter by means of a temperature
resistant cable and has to be installed outside the high
temperature area, where the ambient temperature should
not exceed 50°C (122°F).
|
|
The Titan oval gear flowmeters work by using the liquid pressure to drive a pair of interlocking oval gears. This rotation can be detected by a variety of means to give either a TTL or contact closure pulse output. The unit is manufactured in a choice of materials and pressure ratings to suit most applications and as with all positive displacement flowmeters, the performance improves with increasing viscosity, and can achieve an accuracy of ± 0.1% of reading.
The standard range of sizes covers from 0.25” to 2” BSPF connections, with maximum flows from 1l/min to 500 L/min depending on the model. Viscosities up to 10,000cP can be measured accurately, both in forward and reverse flow. Units are available for high pressure and temperature operation
|
|
Gear Flow Meter with ball bearings.
Specifiation:
Measuring range: 0.005...1,000 l/min
Viskosity: 5...25,000 mm²/s
Linearity: ±0.5 % of actual value
Pressure: max. 630 bar
Fluid temperature: max. +180 °C
|
|
Aluminium Gear Flow Meters with ball bearings.
Specifications:
Measuring ranges: 0.02...500 ltr./min
Viscosity range: 5...25,000 mm²/s
Linearity: ±0.5% of actual value
Pressure: max. 630 bar
Fluid temperature: max. +180°C
|
|
The electronic oval gear meters for product delivery control and measurement are used in the private distribution of low, medium and high viscosity fluids such as fuel, lubrication oil and other special fluids compatible with the construction materials. The oval gear measuring principle adopted offers high precision and low pressure losses together with a compact lightweight design and easy installation.
An electronic card with microprocessor permits control of the display and calibration of the meter. A complete range of models is designed to satisfy all flow rate requirements.
Ease of use, compactness and the independent battery power supply make these products suitable for installation in both stationary systems on fluid transfer and distribution lines and in mobile applications as an accessory for delivery valves and guns and for all other industrial applications that require fluid delivery control.
Performance
- Precision ± 0.5 % in flow rate range
after calibration
- Repeatibility 0.2%
- Pressure loss < 0.5 bars (7 psi) at max flow rate |
|
2150EX Flow Meter for Zone 0 locations
Area Velocity meter - Baseefa approved as ATEX Group II, Category 1G
The 2150EX is an intrinsically safe Area Velocity Flow Meter that is specifically designed and Baseefa-approved for use in Zone 0 and Zone 1 potentially explosive atmospheres under ATEX Directive 94/9/EC.
The AV 2150EX smart Area Velocity probe is built on digital electronics, so the analog level is digitized in the sensor itself. The probe is also factory-calibrated for 3 meter span at different temperatures. This superior built-in calibration eliminates temperature drift in the level signal, providing long-term level stability that reduces recalibration frequency and completely eliminates span recalibration.
The 2150EX is powered by two lithium or rechargeable lead acid battery packs, or by the 2194EX network interface module. Highly efficient power management provides battery life up to 8 months with two-minute data storage interval.
|
|
Volutron VHZ-...GA/GK
The flowmeter VHZ was especially developed for the metering of viscous liquids. The units work volumetrically as gear transmitters with high accuracy and full viscosity stability.
Gear wheel flow meter, with provides a linear frequency signal by flow proportional revolution of a gear wheel and sensoring by a field biased Hall sensor. Viscosity compensated by volumetric operation.
operation independent of viscosity
light and compact design
for cost sensitive application
|
|
Low Volume Rotating Vane Flowmeter DPL
Low Volume Rotating Vane Flowmeter DPM
Turbine Wheel Flowmeter DRS
Low Volume Rotating Vane Flowmeter DTK
Low Volume Turbine Wheel Flowmeter SFL
Electronic Low Volume Flowmeter KFF
Micro Flow Rate Measuring Transducer LFM
Rotating Vane Flowmeter DRH
Rotating Vane Flowmeter DRG
Turbine Wheel Flowmeter DPE
Turbine Wheel Flowmeter DRB
Rotating Vane Flowmeter/- switch /- counter DF
Rotating Vane Flowmeter/- switch DFT
Paddle Wheel Flowmeter/- counter/- batcher DFB
Turbine Wheel Flowmeter / -counter EDM
High Precision Turbine Wheel Flowmeter PEL
Turbine Wheel Flowmeter TUV
Turbine Wheel Flowmeter TUR
Ring Piston Counter DRZ
Oval Gear Wheel Flowmeter OVZ
Screw-Spindle Flowmeter OME
Gear Wheel Flowmeter, aluminum KZA
Screw-Spindle Flowmeter OM..
Gear Wheel Fllwmeter DZR
Universal Indicator ADI
Digital Panel Indicators DAG
Universal Batch Controller ADI-Z
Industrial Batcher, Counter, Flowindicator DAG-AXI
Frequency Transmiter FMU
Universal Bussystem KOBUS
|
|
VOLUTRONIC® - that means high-dynamic, precise volume and flow measurements, evaluated according to the application - from a simple display unit to an intelligent micro-controller solution.
The basis for all this is the KRACHT gear type flow meter. This flow measure product presents the successful result of our long-experienced engineers. The sophisticated tooth system geometry in connection with application-specific bearings are made for the gear type flow meter being an absolute "All-rounder". The gear type flow meter covers a wide medium range: to go from hydraulic oil to printing ink, from gear grease to water based lacquer. The highly-efficient KRACHT electronics take the signals given by the gear type flow meter and ensures that processes are exactly monitored, regulated and controlled.
For example, in process technology as micro-controller for metering and mixing systems, or as flexible measuring and recording electronics for differentiated applications in test bench technology. KRACHT know-how guarantees functional solutions - standardized and optimized for application. |
|
VOLUTRONIC® - that means high-dynamic, precise volume and flow measurements, evaluated according to the application - from a simple display unit to an intelligent micro-controller solution.
The basis for all this is the KRACHT gear type flow meter. This flow measure product presents the successful result of our long-experienced engineers. The sophisticated tooth system geometry in connection with application-specific bearings are made for the gear type flow meter being an absolute "All-rounder". The gear type flow meter covers a wide medium range: to go from hydraulic oil to printing ink, from gear grease to water based lacquer. The highly-efficient KRACHT electronics take the signals given by the gear type flow meter and ensures that processes are exactly monitored, regulated and controlled.
For example, in process technology as micro-controller for metering and mixing systems, or as flexible measuring and recording electronics for differentiated applications in test bench technology. KRACHT know-how guarantees functional solutions - standardized and optimized for application.
|
|
Gear flow meters are positive displacement meters which are used in various applications. KEM offers a great variety of models e.g. for paints, underbody seal, sealants.
Specifications:
Measuring ranges: 0.005...1,000 ltr./min
Viscosity range: 5...25,000 mm²/s
Linearity: ±0.5% of actual value
Pressure: max. 630 bar
Fluid temperature: max. +180°C
|
|
Gear Flow Meters for High Pressure Applications with Autoclave Connections up to 1,000 bar.
Specifications:
Measuring range: 0.02 up to 7 l/min
Repeatability: ±0.1 % of actual value
Linearity: ±0.5 % of actual value
Pressure: max. 1,000 bar
Temperature: max. +150 °C
Connections: Autoclave 3/8’’_8F-375-CX
Materials:
Housing: stainless steel as per DIN 1.4404
Wheel: stainless steel as per DIN 1.4122
Sealing: Viton
|
|
Fibreoptical amplifier and lightpulse receiver for applications in electrostatical painting systems.
Specifications:
FOP 60
Power supply: lithium battery
Ambient temperature: –20 up to +50°C
Ex protection: EX II 2 G EEx ia IIC T4/T5/T6
OPTV
Supply voltage: UB: +7 up to +30 V
Ambient temperature: –20 up to +60°C
Output: frequency output
Ex protection: EX II2 G EEx ia IIC T6
The integral pickup detects the r.p.m. of the gears and the FOP provides a flow-proportional light pulse signal.
The OPTV receiver will convert the light pulses into a current or voltage squarewave signal.
|
|
K33 and K44 are nutating-disk meters that measure the exact quantity of the dispensed fuel or lubricant. They are designed for non-commercial use only. These flow-meters are reliable, inexpensive, easy to install and simple to calibrate on the workplace.
The Pulser model is fitted with a pulse emitter for connection to a fuel management system.
Thanks to reduced flow resistance, they can also function by gravity.
Performance Specifications
- Flow-rate (range): 20÷120 l/min (5,3÷32 gal/min).
- Precision: ±1% of flow range after calibration.
- Repeatability: 0,2%.
- Max. operating pressure: 10 bar (142 psi).
- Bursting pressure: 30 bar (426 psi).
- Readout system:
- K33, 3-digit subtotals (max 999 litres), 6-digit totals.
- K44, 4-digit subtotals (max 9999 litres), 7-digit totals.
- Resolution: 0.1 litre.
- Pulser card type: "Open collector", frequency: 10 pulses/litre, power supply: 6-24 V DC, max 10 mA. |
|
Flow ranges from 0.001 to 120 GPM, pipe sizes up to 1-1/4" NPT, Accuracy of +/- 0.5%, repeatability of +/- 0.1%, Materials of construction available are 303 stainless steel, 316 stainless steel and Aluminum. Pressure rating up to 5,000 PSI, bi-directional flow capabilities. Sensors available include Pulse, mA and Voltage.
These flow meters work great for applications that require the measurement of oil, grease, fuel, solvents, polyurethanes, brake fluid, skydrol, paints, adhesives, sealants and resins.
|
|
|
Suitable for fuels, lubricants and non-corrosive fluids to a viscosity of 1000cPs, the M100 is a 100mm (4"), high flow, oval gear flowmeter and is capable of measuring fluid flows of up to 1200LPM. The M100 is accurate to +/- 0.5% and provides exceptional levels of reliability and durability.
|
|
fuel meter
DM100 Flow Meter
DM150 Flow Meter plus Filter
The DM100 has been designed to measure diesel, kerosene and petrol, and is made from corrosion resistant aluminium with easy to read mechanical register.
|
|
|
|