FLOW RATE SENSOR QS-2-B-008 and LEAKAGE SENSOR LS-2-B-(*) fluid-Check (FOR HYDRAULIC OIL)
Examples:
Leakage (*)
Monitoring flow rate and wear of pumps
Operability of accumulators
Filter transmittance
Heat exchangers
Nozzle flow rate
Speed of hydraulic motors
Description:
Via a hole in the pipe (plastic deformation with the measuring connector serv-Clip® Type 2-mounting on non-pressurized pipes-INSTALLATION WITHOUT CUTTING PIPES-3 MINUTES), the sensor is placed directly into the oil circuit. The measuring system is based on the calorimetric principle, measuring flow rate speed in Meter/Second. Inexpensive and rapid Mounting.
It is combined with measuring connector serv-Clip® Type 2.
Diameters in mm and inches available. www.servclip.com
Other applications (installation of manometers, particle counters and sensors(temperature, pressure, aqua, flow rate and leackage).
Technical data
- Measuring range 0,05 …8 m/s (HYDRAULIC OIL)
- Flow rate up to 600 Liter/Min (depending on ID)
- Leakage from 0,02 Liter/Min (*)
- Temperature -20...80°C
- Output signal 4 ... 20 mA
- Power supply 24 V DC +/-10%; 150 mA
- Electrical connection M12-universal connector
- Range setting by micro-switches 6 LED
- For pipe diameters Ø 12 mm and larger
Calibration service
You have to indicate us the ID of your tubes and the wished min/max liter/minute. You get a calibration table for your own technical case. |
|
In many fields of process and plant engineering liquids or gases play a considerable part in the results of quality control and operational safety. In the case of coolant and lubricant supply, monitoring the functioning of pumps and aggregates, ventilation as well as monitoring the product itself a failure of the flow can cause considerable damage and downtime. Thus it is very important to monitor that these media are at the right place at the right time and in sufficient quantities. Electronic flow monitors based on the calorimetric principle are especially suited for binary flow monitoring.
As these systems work without any mechanically moved parts they can be mounted independent of mounting position and flow direction. Another distinguishing feature of the calorimetric principle is its independence of the viscosity of the medium. Electronic flow monitors are based on the principle of thermal conductivity.
The flow monitor consists of a sensor that converts this physical effect into an electrical signal, and of a control monitor which processes the sensor signals and converts them into a binary signal output. The sensor is mounted directly into the medium. |
|
Sensortechnics is a leading manufacturer and distributor of a wide range of sensors and fluid control devices. The product portfolio includes basic pressure sensors, rugged transmitters, submersible level sensors and customised pressure sensing systems from 1 mbar up to 1000 bar as well as liquid level switches, oxygen, flow and force sensors. Additionally, Sensortechnics offers ultrasonic air bubble, air-in-line, liquid level and fluid monitoring sensors and detectors. Fluid control devices include miniature solenoid valves and diaphragm pumps, electronic pressure controllers and custom specific fluidic control systems.
Sensortechnics has more than two decades of experience in providing highly customised sensing products and in the development of complex integrated fluid control systems for OEM customers worldwide. |
|
Air Flow Sensors Based on the Calorimetric Principle for Air or Gaseous Media. Compact, Precise, Rugged and Reliable
vent-captors are compact, self-contained flow sensors that work according to a calorimetric principle. The principle allows for the creation of compact, reliable flow sensors with a price/ performance ratio not possible with other physical flow-sensing principles.
Especially at a low flow rate, no other sensing principle can achieve the high accuracy of a vent-captor.
First engineered by weber Sensors more than 20 years ago, weber continues to pioneer sensors based on this principle.
vent-captors are available as insertion and in-line types. Both are also available with a binary output as switches and adjustable set-point and with an analog output as meters with an adjustable measuring range. |
|
for measuring standard flow velocity, standard volume flow and temperature of the medium
probe diameter 20 mm with Pt100 sensor element
measuring range 0.08...60 m/s
time constant approx. 20 s
maximum working pressure: up to 10 bar
working temperature range: -10 °C... 240 °C
materials: stainless steel, epoxy resin, glass
can be sterilized
|
|
Compact Flow Meter with analog current output
4 to 20 mA current output
A wide range of pipe sizes
Easy installation by a welding fitting
Flow range is adjustable from 10% to 100% of the specified maximum range |
|
Analog Input Flow Indicator - Series FIV
Flow Rate and Totalization
Sight Flow Indicator - Series SF2
1/4 to 1" Connection Size, SPDT or Pulse Output, Window Style
Sight Flow Indicator/Transmitter - Series SFI-800
1/2 or 3/4" Connection Size, Optional Output Sensor Package
Sight Flow Indicator/Transmitter - Series SFI-100T
1/2 or 3/4" Connection Size, Optional Output Sensor Package
|
|
Barksale offers a range of flow sensors for common flow detection applications for liquid media.
Operation of the BFS flow switch is based on the movement of a spring-loaded piston within a cylindrical tube. |
|
Turbine Flow Sensor - Series TF
0-5 VDC Output, Liquid or Gas |
|
| Customers using pressure decay/flow instruments or tracer gas detectors need to be able to present a known leak to the test system, should the leak detector recognise the leak at the correct value then the test system is within calibration. |
|
The SW-600 series is a range of flow sensors based on the calorimetric measuring principle. This priciple is based on the physical effect that flowing medium absorbs heat energy. The cooling of the sensor tip by the flowing medium is registered and electronically evaluated.
Flow sensors are an essential component of processing- and operation plants in systems technology in order to ensure operational safety. They are used for detection of liqiid media and for coolant supply as well as for operation control at pumps. |
|
Reliable measurement systems are required for process-related monitoring and control of flow velocity. These must be resistant to environmental influences.
Technology
SCHMIDT® Flow Sensors for air and gases manage without moving parts, exploit the hermal measurement principle consequently and gain from the latest thinfilm and semiconductor technology. Highly integrated circuits and microprocessors technology have led to highly sophisticated sensors who compare favourably with any economic demand.
Special features of SCHMIDT® Flow Sensors:
* No moving parts = no wearing
* Very high turn-down ratio
* Quick response time
* Small pressure loss
* Ideal for very small flow velocities
Applications
* Heating, ventilation and air-conditioning technology
* Environmental technology
* Clean-room technology
* Process technology
* Compressed-air
* Medical technology |
|
TURCK's wear-free flow sensors reliably monitor the flow of gaseous and liquid media. The calorimetric operation of the sensors is based on the heat transport/heat loss principle, i.e., when fluid moves over the heated sensing probe, heat is conducted away from the sensor. The heat loss is thus a measure of the flow speed.
There are insertion and inline sensors available which can also be used in explosion hazardous areas according to ATEX 100a. Customer-specific versions with regard to special housing designs, materials and connections on request. |
|
The RFIK mechanical hydraulic tester provides the ideal solution for servicing and commissioning
hydraulic circuits on agricultural and other mobile machinery.
The kit comprises of a direct acting flow indicator with built in thermometer, a loading valve and a pressure gauge all built into a strong steel case with a removable lid.
The unit is self contained and requires no electrical power. The dials are clear and easy to read.
Installation is extremely simple and the test kit can be connected into either the pressure or return lines. The loading valve and pressure gauge allow a progressive build up of system pressure in complete safety.
The test kit provides the service engineer with quick, accurate and simple performance testing of pumps, motors, valves, cylinders and complete hydraulic
circuits.
Note: This unit is not designed for permanent installation. |
|
Flow Indicators are designed for continuous monitoring or intermittent use commissioning and
servicing hydraulic systems up to 420 bar, 6000 psi. The large clear 63mm diameter dial ensures that quick checks can be made to determine pump performance and setting of flow control valves. They can be used on mobile and industrial hydraulic circuits. Also lubrication and coolant systems using oil.
These direct acting flow indicators can be installed in hazardous areas or on applications where no power is available. The flow indicator design ensures good reliability and minimises the effects of contamination. |
|
Mass Airflow sensors contain a thin-film, thermally isolated bridge structure containing heater and temperature sensing elements. The bridge structure provides a sensitive and fast response to the flow of air or other gas over the chip. State-of-the-art chip design and manufacturing techniques allow the microbridge to be remarkably sensitive, fast, small. Used wherever airflow needs to be measured.
|
|
| OEM products are engineered to meet low cost, high volume requirements and to fit common or uniquely specific customer application demands. OEM mass flow meters are used in air, compressed air, nitrogen, methane, natural gas, carbon dioxide, argon and other gases in applications that require wide turndown ratios (100:1), low flow sensitivity, no moving parts and negligible pressure drop. These products feature true mass flow analog outputs (without additional pressure or temperature transducers) as well as temperature, totalizing and alarm outputs. OEM Flow switches are used in liquids, gases and slurries. They are ideally suited for low flow pump protection, monitoring lube oil, detecting seal leakage, verifying analyzer flow, monitoring cooling water and other critical applications. These products feature 300 series stainless steel rugged industrial design with no moving parts and negligible pressure drop. Optional materials of construction include CPVC with Hastelloy C-22 tips for corrosive applications. |
|
...disturbance insensitive and long-lived!
The turbine flow sensors of the product line Turbotron are sensors for flow rate measurement or dosing applications for liquids. Through its especially compact type, its very wide measuring range and its convincing precision of measurement, it has an almost unlimited application.
Function
The liquid flowing into the Turbotron is divided by the guiding blades in four split beams. These hit the rotor from four directions and put it in motion. The uniform loading of bearing from four sides causes the forces to cancel themselves out for the most part and wear is reduced to a minimum.
The extremely hard bearing materials, sapphire and hard metal, ensure in addition an extraordinary life expectancy.
The rotor rotation rate is now converted into an electrical pulse signal (frequency):
VTH and VTP are equipped with rotors which are fitted with magnets. A Hall effect sensor recognizes the rotation of the rotor.
VTI has stainless steel pins in the rotor. An inductive proximity switch detects the rotor rotation.
In both cases, a flow-proportional frequency signal (square wave signal) is available. |
|
The CAT3 is a DC or AC powered, microprocessor
controlled transmitter. It outputs a pulse scaled per unit of
flow, and analog signal proportional to flow rate. The
CAT3 can be configured with High and Low alarms. |
|
Visoflow WR1-...GM/GK
Mechanical Flow Indicator for liquids, with a rotor for quantitative flow indication in a special tube-shaped glass housing. A signal-red rotor provides a directly flow-proportional indication of the momentary flow-rate. Rugged design in brass or stainless steel.
cleaning mechanism of the internal surface of the glass
visibility of rotor 360°
floating bearing for liquids
grease-free ball bearing for gaseous media |
|
Rotor Flow Indicator w. Self-cleaning mech. DAA
Flow Indicator with Rotor DAH
Rotating Vane Flow Indicator DAF
Rotating Vane Flow Indicator DIH
Rotating Vane Flow Indicator DIG
Rotating Vane Flow Indicator DKF
Flow Indicator with Rotor DAR
Flow Indicator with Flap DAK
Flow Indicator with Flap and Scale DAZ
Flow Indicator with/without Ball DAB
Flow Indicator with Ball DKB
|
|
| Designed with body in aluminium, nickel-plated brass or 304 stainless steel. Execution with visual indication only, graduated scale on the glass tube, max. pressure 15 bar and 0,1 to 60 LPM flow rate; electric execution with visual indication, 1 or 2 adjustable alarm points, max. pressure 15 bar and 0,1 to 60 LPM flow rate; simple electric execution with 1 or 2 adjustable alarm points, max. pressure 150 bar, 0,1 to 140 LPM flow rate. All these models can be supplied with specific springs depending on the fluid viscosity up to 200 Cst. Electric execution for water application with 1 or 2 adjustable alarm points, 0,3 to 60 LPM flow rate, max. pressure 50 bar. |
|
- Piston type
- Fluid : Water , oil , other liquid available
- Flow range : 15 ~ 24000 l/h (at Water)
- Accuracy : ± 3 % F.S , On request : ± 2.5 % F.S
- Size : 1/4" to 2-1/2"
- Connection Size : NPT , Flange Type on Request
- Working Limits : Temperature : -10°C to +150°C
- Max. Pressure : 30 kg/cm²
- Housing enclosure : IP 65
- Housing material :
NS,CS,MS types-Aluminum Alloy
ES type-316SS
- Lens material:Safety glass
- Mounting:Vertical,horizontal available
- Materials : Brass , 316SS wetted parts
- Alarm switch : Micro switch,inductive switch available |
|
Solid State Flow Sensors
Designed to monitor for positive presence of cooling airflow, this velocity sensor operates on 5V DC. The sensor can be mounted on a board, in a socket, or hard-wired to a bracket. The SAF is an AMBIENT COMPENSATED device affording close setting tolerances up to 60°C. This product is available hermetically sealed for use in hazardous or contaminated environments.
- SAF Series Air Flow Sensor
The advanced SAF Series Airflow Switch provides early detection and protection from overheating in mainframe computers and peripherals, large power supplies; HVAC applications, medical diagnostic equipment, and other complex electronic systems requiring forced air cooling.
- DLS Series Air Flow Sensor
The new thermal emulator, or "Thermulator," is a switching device that monitors both temperature and air velocity in a forced air cooling system. This dual output logic switch (DLS) has the unique capability of providing two separate, preset alarm logic outputs. |
|
We help you to develop a superior product based on our leading CMOSens® Technology. Together with our customers we have implemented modules and complete devices for the following markets and applications.
In cooperation with our customers we for example developed:
- Digital mass flow controllers
- Battery powered flow meters
- Gas meters
- Flow meters with 200 slm range for medical applications
- Flow meters up to 30'000 slm
- System design with combined flow and pressure control (gaschromatography)
|
|
Hoffer flow control
Controls turbine flowmeters
Of all the various types of flow transducers available to industry today. None are so universally applicable as turbine flowmeters. They continue to be the most common way to measure flow electronically and have the ability to measure available upon request offering detailed, technical information. |
|
FLOW RANGE (Note 1)
Ranges shown are standard ranges — other ranges are available. Contact Hoffer Flow Controls Applications Group.
BEARING TYPES (Note 2)
—CB Hybrid Ceramic, Self-lubricating shielded ball bearings. Ball bearings must be used on CO2, may be used on H2O and never on H2O/Sand or CS.
—C Hard Carbon Composite sleeve bearings. For use on H2O only.
—T Tungsten Carbide sleeve bearings. Tungsten Carbide must be used on H2O/Sand and CS, may be used on H2O, and never used on CO2. |
|
| Pointers of passage who come used for the visual control of the flow of liquids in the pipages, realized or in the flangiata version that in the threaded version, to single and double crystal, realized in grey cast iron, brass, carbon steel, stainless steel until to series PN 25. |
|
| With more than a quarter of a million units in operation, in applications around the world, Cameron is the undeniable leader in the design and manufacture of totalizers and flow analyzers. The NuFlo MC Family of Flow Analyzers delivers a broad range of functionality and capability from the straightforward MC-II Totalizer, which provides rate and flow, to the MC-III EXP Flow Analyzer, which utilizes Modbus® communications to download extensive archival logs in less than a minute. The MC Family of Flow Analyzers is ideal for use with Cameron's comprehensive line of turbine meters and performs equally well with all turbine brands on the market today. |
|
Phoenix America Inc.'s proprietary thermoplastic based bonded magnetic materials allow for intricate shapes and form factors to be developed. This capability has allowed magnetics to be used in variety of custom applications such as Flow Sensing.
The ability of Phoenix America Inc. to manufacture a magnetic target in literally any shape imaginable leads to employing magnetic speed sensing technology in several novel ways. On application is flow sensing. Phoenix America Inc. magnetic targets and magnetic speed sensors can be employed to derive fluid or air flow.
Replace an expensive flow sensors with complex mounting and interpreting algorithms with a Phoenix America Inc. magnetic sensor and propeller. We will custom develop a flow sensor for your application should you solution require it.
Since a Phoenix America Inc. magnetic based sensor is a non contacting device it can literally see through non ferrous objects such as water lines. Interfacing with a custom developed Phoenix America Inc. magnetic propeller, a Phoenix America Inc. sensor can either be threaded into a galvanized pipe to sense through a plastic tube. |
|
|
|