Designed with body in aluminium, nickel-plated brass or 304 stainless steel. Execution with visual indication only, graduated scale on the glass tube, max. pressure 15 bar and 0,1 to 60 LPM flow rate; electric execution with visual indication, 1 or 2 adjustable alarm points, max. pressure 15 bar and 0,1 to 60 LPM flow rate; simple electric execution with 1 or 2 adjustable alarm points, max. pressure 150 bar, 0,1 to 140 LPM flow rate. All these models can be supplied with specific springs depending on the fluid viscosity up to 200 Cst. Electric execution for water application with 1 or 2 adjustable alarm points, 0,3 to 60 LPM flow rate, max. pressure 50 bar.
|
|
- Piston type
- Fluid : Water , oil , other liquid available
- Flow range : 15 ~ 24000 l/h (at Water)
- Accuracy : ± 3 % F.S , On request : ± 2.5 % F.S
- Size : 1/4" to 2-1/2"
- Connection Size : NPT , Flange Type on Request
- Working Limits : Temperature : -10°C to +150°C
- Max. Pressure : 30 kg/cm²
- Housing enclosure : IP 65
- Housing material :
NS,CS,MS types-Aluminum Alloy
ES type-316SS
- Lens material:Safety glass
- Mounting:Vertical,horizontal available
- Materials : Brass , 316SS wetted parts
- Alarm switch : Micro switch,inductive switch available
|
|
Flowmeters, Switches, and Transmitters
Flowmeters from Orange Research provide accuracy and reliability in an affordable, rugged package. These industrial quality flowmeters combine modern technology and materials with a familiar easy-to-read pointer and dial gauge. A patented magnetic movement allows flow sensing at high line pressures and operation in any orientation.
|
|
vent-captor - Insertion type Air Flow Switch for gaseous media
Compact Air Flow Switch for AC/DC Applications
Adjustable Set-Point between 1 m/s and 10 m/s
For general applications
Compact Air Flow Switch for DC Applications
High accuracy Set-Point adjustable between 0.5 m/s and 20 m/s
For critical Applications
Easy installation with Special Flange (supplied), or optional pipe adaptor
|
|
Compact Metering Flow Switch with analog display
1/2" Thread (NPT or BSP)
Easy to install
Set point adjustable over full measuring range
Flow range adjustable for best resolution
Indexed range pot enables flow rate measurement
|
|
| ... products without technical information |
| |
|
|
|
|
Mobile Measurement kit FM-1-B FLUID-CHECK in suitcase for :
- Flow rate sensors
- Leakage sensors
- Temperature sensors
- Pressure sensors
Examples for :
Fixed displacement pumps Pumping capacity
Variable capacity pumps Percentage of leak oil
Oil coolers Flow characteristics
Water coolers
Differential cylinders Leak oil
Synchronous cylinders Sealing damages
Plunger cylinders Moving speed
Oil motors Leak oil
Pressure accumulators Bladder control
Charging behaviour
Nitrogen charge
Technical Data :
- With multi-purpose display with one separate analogue input, with
4 – 20 mA and scaling facility
- Suitable for display of input channel A or input channel B as well as the sum A+B, the differential A-B or the ratio A:B
- Display range +/- 4 1/2 decades at 15 mm size
- Power supply 115 / 230 VAC or 18 – 30 VDC
- Setup of zero and full scale by means of two front keys and
menu support
- Selectable linearisation functions
Included :
- Power cord 230V AC
- Connecting cable with plug
M12 connector for kit and sensors
- Suitcase made of plastic (black/blue)
Outer dimension 340 x 275 x 84 mm
- Technical documentation and operating instructions
|
|
The 950 Series includes a compact, single channel device and a deluxe, multi-channel device for operation of up to four mass flow instruments. The 950 Series is designed for use with the Sierra Model 830L, 830M, 840L and 840M instruments, but can be used on any brand of MFM or MFC. Both of these powerful digital systems supply power (+/- 15 VDC), display the flow rate, and offer set point control for MFC’s.
951 UNIQUE PRODUCT FEATURES
- 5 digit LED display
- Front-panel pushbutton set point, calibration and alarms
- Integral power supply (+/- 15 Vdc)
- Compact size—1/8 DIN
- CE Approved
954 UNIQUE PRODUCT FEATURES
- 4 line, 20 character LCD display
- Valve Close, Valve Open (Purge) pushbutton override
- Front-panel menu adjustable:
- Flow units
- Set Point
- Totalizer
- Gas K-factors
- Alarms
- Master/Slave Ratio Control
- Calibration
- Analog Outputs: 0-5, 0-10 VDC and 4-20 mA
- Digital Output: RS-232 and RS-485
- CE Approved
|
|
|
|
|
|
Specially designed for filling of all liquid and semi-liquid cosmetics (shampoo, conditioner, hair-dye, shower gel, bubble bath, liquid soap, milk, suntan milk, lotions, deodorant, roll-on, perfumes, etc), FLEXO is extremely easy to use thanks to mass flowmeters linked to a servodrive for the up/down motion of the nozzles.
The benefits are significant :
- excellent adaptation to all types of liquid
- simple, in-line filling system with no moving mechanical parts
- bottom-up filling of the bottles with variable up/down speed of the nozzles and programmable according to the shape and contour of the bottles to be filled
- increased speeds thanks to the continuous injection filling system (no pump suction cycle)
- optimized dosing accuracy
- standard cleaning in place (CIP) and standard sterilization in place (SIP)
- programmable cleaning speed according to the products (quality of the cleaning is optimized and the cleaning times reduced)
- option of installing 2 filling circuits in parallel, with cleaning in place (CIP) for one circuit while the 2nd circuit is filling and vice versa
- quick format changeovers without tools
- stainless steel guards with "balcony" design for optimized prophylaxis.
PKB deliberately chose standard mass flowmeters instead of electromagnetic flowmeters to avoid the issue of certain non-conductive products and the constraints of very precise pressure regulation in the feeder tank.
|
|
|
|
|
|
Mobile Measurement kit FM-1-B FLUID-CHECK in suitcase for :
- Flow rate sensors
- Leakage sensors
- Temperature sensors
- Pressure sensors
Examples for :
Fixed displacement pumps Pumping capacity
Variable capacity pumps Percentage of leak oil
Oil coolers Flow characteristics
Water coolers
Differential cylinders Leak oil
Synchronous cylinders Sealing damages
Plunger cylinders Moving speed
Oil motors Leak oil
Pressure accumulators Bladder control
Charging behaviour
Nitrogen charge
Technical Data :
- With multi-purpose display with one separate analogue input, with
4 – 20 mA and scaling facility
- Suitable for display of input channel A or input channel B as well as the sum A+B, the differential A-B or the ratio A:B
- Display range +/- 4 1/2 decades at 15 mm size
- Power supply 115 / 230 VAC or 18 – 30 VDC
- Setup of zero and full scale by means of two front keys and
menu support
- Selectable linearisation functions
Included :
- Power cord 230V AC
- Connecting cable with plug
M12 connector for kit and sensors
- Suitcase made of plastic (black/blue)
Outer dimension 340 x 275 x 84 mm
- Technical documentation and operating instructions
|
|
Users of conventional universal display units can have difficulty in making use of their device´s options menu. Special applications require many more functions that are often not available with conventional units.
KRAL BEM 300 to 500 electronic units enhances the KRAL Volumeter performance.
Your advantages:
- Two-channel, i.e. differential measurement.
- Temperature and pressure pulse compensation.
- Measurement conversion.
- 7 point linearization.
- Limit value for a relay output, i.e. regulation of a bypass valve.
- Threshold value for signal suppression.
- Clear and easily readable display.
- Accurate handling by the use of a clear menu structure.
- Multiple mounting options. (KRAL Volumeter, wall, pipe, control panel).
|
|
HFM 436 Lambda - Heat flow meter
With the HFM 436 Lambda, samples measuring 30 cm x 30 cm or 60 cm x 60 cm and of variable thicknesses ranging from a few millimeters to 10 (20) cm are tested between two heat flux sensors in fixed or adjustable temperature gradients. After a few minutes for the system to reach equilibrium, the built-in PC or external computer determines the thermal conductivity and thermal resistance of the sample.
Automatic plate movement and determination of the sample thickness simplify test preparation.
All test parameters as well as the calibration data are stored in the PC and documented.
Determination of thermal conductivity with the HFM 436 Lambda meets the industry standards ASTM C 518, ISO 8301, JIS A 1412, DIN EN 12939, DIN EN 13163 and DIN EN 12667.
|
|
AUTOMATION AND CONTROLLERS
ELD - ELECTRONIC LEAK DETECTOR
ELD is an easy-to-use device that is fully compatible with all types of press or molding equipment and allows users to quickly locate any leakage of plastic materials (or other liquids) inside the mold. Installation is straightforward requiring only that the ELD be connected to both the thermoregulation system and hot runner. Energy profile analysis and the application of mathematical algorithms enables ELD to monitor all hot runner system zones and, if required, close down the production cycle prior to any serious damage being caused.
The ability to identify, in real time, where leakage is occurring means the cause of the leak can be identified and - as a result - a reduction in both maintenance costs and the time required to return the system to full working order.
|
|
|
|