Bowman Engine & Transmission Oil Coolers are equally suitable for cooling torque converter, automatic transmission and engine oils. Being water cooled they have the advantage of freedom from accidental damage and also encourage quicker warming up of the oil, a feature which is particularly valuable in cold climates. The tube stack is fully floating so that thermal stresses are minimised and it can easily be removed should cleaning be necessary.
|
|
|
Bowman Hydraulic Oil Coolers are suitable for heat transfer fluids, lubricating, transformer & quenching oils. They are high quality products incorporating the best materials and the latest technical features. The tube stack is fully floating so that thermal stresses are minimised and it can be easily removed should cleaning be necessary.
|
|
|
|
|
|
Bowman Marine Oil Coolers
Bowman produce a variety of heat exchangers, water cooled manifolds, charge air coolers and oil coolers for use on marine engines.
Most Bowman marine products are fitted with bronze covers which are highly corrosion resistant and therefore suitable for use with sea water. Some of the smaller units are fitted with neoprene end covers which can fit directly into the sea water pipe work.
Bowman manufactures a range of standard heat exchangers which can be used to marinise a variety of engines up to 1400 kW (1900HP). There are also a large number of engine specific heat exchangers and exhaust manifolds produced for a variety of Cummins, Ford, Perkins, British Leyland Rover, General Motors, Peugeot, Mercedes, VW, Mitsubishi, New Holland and Genesis engines.
Bowman also manufactures engine oil coolers suitable for all types of engines up to 1200kW (1600HP) and gearbox oil coolers suitable for all types of engines up to 1500 (2000HP). For larger engines please contact the sales department. The EC to PK range of shell and tube heat exchangers has been approved for marine use by the American Bureau of Shipping (ABS).
There are a standard range of charge air coolers suitable for engines up to 240kW (320HP) as well as some especially designed for Cummins, Ford and Perkins engines.
Bowman manufactures a range of hydraulic oil coolers suitable for use with deck machinery, bow thrusters, power steering etc.
|
|
Engine & Transmission Oil Coolers
Bowman Engine & Transmission Oil Coolers are equally suitable for cooling torque converter, automatic transmission and engine oils.
Hydraulic Oil Coolers
Bowman Hydraulic Oil Coolers are suitable for heat transfer fluids, lubricating, transformer & quenching oils.
DC Oil Coolers
Bowman DC Oil Coolers are designed for use on small marine transmissions.
Marine Oil Coolers
Bowman produce a variety of heat exchangers, water cooled manifolds, charge air coolers and oil coolers for use on marine engines.
|
|
|
Oil chillers RFCH and KRO allow cooling of all process using oil as power transmission, thermic fluid or lubrification. From 1 KW up to more than 100 KW, these chillers are adapted to difficult ambiant industrial aeras: Exemples: Filters, hydraulic bancs, lubricant systems..
|
|
The GEA Bloksma plate fin oil (PF) cooler is a well proven, compact (25% of conventional), slim lined heat exchanger for cooling oil by means of sea- or fresh water and is suited for a wide range of marine and industrial applications. Unlike conventional shell & tube types it contains a bundle with a high density plate fin surface around the tubes. The cooler is available in 4 standard shell diameters ranging from 100 ñ 280 mm, covering 1 to 170 m2 plate fin surface. Connections in most cases can be DIN or SAE compatible or BSP threaded. The length of the cooler is variable. Standard components and modules enable to provide a large number of solutions, meeting customer requirements at a short delivery time.
Two standard versions are available:
* IV Industrial Version: For non-aggressive or controlled cooling water
* MV Marine Version: For aggressive or surface water
|
|
Oil cooling systems
AKG T- and TL-Range
The first choice for oil cooling in hydraulic circuits.
Your Advantage
The correct cooling solution offers a longer oil life, i.e. lower maintenance and change frequency. A constant oil temperature also means improved machine precision.
AKG-Range T1 - T 11... maximum working pressure 26 bar
AKG-Range TL1 - TL 6 ... maximum working pressure 14 bar
|
|
GENERAL FEATURES
The Cosmotec water/liquid chiller is designed especially for use in industrial situations.
The use of the chiller provides the means to accurately control the temperature of the oil to be cooled.
All the production steps, from the development to the components study, are oriented to offer an high quality and a customised olution in ccordance with the customer’s needs.
|
|
Plate heat exchangers
type PWT
The plate heat exchangers type PWT form an addition to our product range in the field of oil-water heat exchangers. In some cases they represent a cost-effective and space-saving alternative to the standard smooth pipe heat exchangers.
Description
Soldered plate heat exchangers are assembled from stamped special steel plates and connected by means of a copper shim and a special soldering process. Stamping creates a highly turbulent flow in the chambers between the plates, which enables excellent transfer of the heat. The type PWT plates stand out by their following characteristics:
Plates and connections made from special steel 1.4401
Connecting elbows and internal thread and keying surfaces.
|
|
Water oil coolers are used in many stationary hydraulic and lubricating systems to optimize the oil temperature. Water oil coolers are especially suitable in environments where water is easily accessible. The extremely quiet water oil cooler is ideal for indoor use where the cooling water cannot ice-up. The surplus energy from the heated cooling water can for instance be used to heat other water.
Off-line cooling and oil filter system
In all modern hydraulic systems, off-line oil cooling and filtering is becoming increasingly popular as the system can operate around the clock independently from the main system to avoid differences in pressure and flow conditions.
We supply both brazed plate and bolted plate heat exchangers. The main difference between these two propducts is that the bolted plate products have gaskets which enables you to change the plates easily.
|
|
Cooler for compressor use
General power:4-110KW
Combi air/oil cooler
Oil flow:12-110L/min
Working pressure:15bar
Max power:135kw
|
|
BWT platecooler series
Highly efficient heat transfer
Compact dimensions
Low water consumption
Highly turbulent flow
Very efficient oil / water cooler with small physical dimensions. Easy handling and installation. Due to highly turbulent flow very little tendency of fouling, almost maintenance free.
|
|
Plate Heat Exchangers
Soldered and bolted plate heat exchanger
- PWT
- TL
Up to 30 bar oil pressure and from 25 to 3 000 l/min. oil flow. Operating temperature from -100 to +195 degrees. Soldered plate coolers are available from 10 - 200 plates. Bolted plate coolers are highly flexible and easy to clean thanks to the modular system.
|
|
Bolted plate coolers are ideal for sea water and specialist applications.
They are designed for use with special fluids or large capacity applications.
The main difference between the Brazed Plate and Bolted Heat Exchangers is that the Bolted Heat Exchangers have gaskets. A benefit of these heat exchangers is that they can easily be adapted by adding or replacing plates.
Flow ranges: 10-4600 m3/h
Working pressure: 10 - 25 bar
Temperature range: -20°C - +180°C
Connections: DN25-DN500 Weld neck, flange or threaded
|
|
Oil/water Heat Exchanger
Tube Bundle
Extremely compact as well as large construction series
AM
EKM
ECM
CM
SSCM
UKM
UKTM
with and without integrated aluminium ribs. Up to 35 bar oil pressure, cooling capacity from 1.5 to 300 kW, respectively 25 to 1 500 l/min. oil flow. Optionally with bypass valve for pressure peaks. Simple to clean.
|
|
|
Water-oil heat exchangers are shell and tube type. they permit to waste the heat in hydraulic plants. They can operate on exhaust line of the main hydraulic circuit, or on a separate circuit dedicated to cooling
|
|
WATER-OIL HEAT EXCHANGERS WITH TUBE BUNDLE
They consist of small diameter smooth tubes; this allows the best compromise between high thermic yield and low pressure loss. For a good exchanger practices some oil rates are indicated in the tables. Going down to the lowest rate of flow, indicated in the tables, the low oil speed causes a great loss in yield, whereas a rate of flow which is superior to the maximum indicated, causes great pressure loss and does not considerably increase the thermal yield. The yield diagrams indicate the heat quantity each exchanger can disperse according to the difference between oil and water mean temperatures. Such diagrams assume the exchangers to be working with the maximum oil rate indicated in the table. With the minimum rate, the yield decreases by about 10%. Required water volume is a follows:
85 l/h for each kW to disperse with water temperatures (20°C)
170 l/h for each kW to disperse with higher water temperatures
|
|
HW Serie:
Water-oil shell and tube heat exchangers, used for the cooling of industrial systems and in the marine sector. Fully extractable shell and tube for better maintenance of the heat exchanger. Aluminium body, designed to allow maintenance without the need to disassemble the heat exchanger. Cast iron heads in the industrial version, bronze in the marine version. Fluid circulation exclusively in countercurrent.
|
|
Basco Type OP Heat Exchangers
First introduced in 1962, the Basco OP design has proven to be the preferred TEMA Type AEW shell & tube heat exchanger in the market. The "OP", or "O-Ring Protected" design features removable tube bundle, nozzle location flexibility, and a unique threaded O-ring retainer that permits removal of the reversing bonnet without disturbing the piping or draining the shellside fluid. Removal of the channel cover permits full inspection and cleaning of the tube side.
|
|