Primary current: 100, 200, 30, 400, 60 A
VAC: 208, 240, 480 V
... 66% and total installation costs by over 30% Pre-installed UL listed Class J fuse holder – unique Class J size eliminates the need for any rejection type fuse clips Optional features offer ...
Primary current: 630 A
VAC: 690 V
... N) in-line fuse switch disconnector for busbar systems 185mm with an overall width of 100mm. It is the most inovative and cost-efficient market solution to realize grid disconnection ...
Mersen - Electrical Power
Primary current: 160 A
VAC: 690 V
Approvals & Standards • IEC/EN 60 947-3 • For NH-fuse links size 000/00 in accordance with IEC/EN 60 269-2, VDE 0636-2 The production programme of MULTIBLOC® series 00.ST8 comprises NH fuse switch ...
Mersen - Electrical Power
Primary current: 250 A
VAC: 800 V
... installation of MULTIBLOC® NH fuse switch disconnectors in distribution units with central cover, respective covers are used to obtain a uniform profile in height and length. MULTIBLOC® size 1 and size ...
Mersen - Electrical Power
Primary current: 32 A - 50 A
VDC: 1,000 V
The RM PV range of fuse disconnect switches is designed for use with gPV fuses that are cylinder-shaped. The switches are modular in nature. They are perfectly suitable ...
Primary current: 630, 1,250 A
VAC: 36, 38.5, 12, 24 kV
The Driescher's H22 is an indoor medium-voltage fused switch disconnector that is constructed with a three-pole feature. It is equipped with a rated current amounting from 630 A up to 1250 A. The rated ...
Fritz Driescher & Söhne GmbH
Primary current: 630 A
VAC: 12, 24, 36, 38.5 kV
... earthing switch is mounted above or below, on the switch frame (retrofitting ispossible).Type H 22 SEA are available with earthing switchesintegrated in the switch frame.A positive mechanical ...
Fritz Driescher & Söhne GmbH
Primary current: 630 A - 1,250 A
VAC: 12, 24, 36, 38.5 kV
Type H 22 SEA are available with earthing switchesintegrated in the switch frame.A positive mechanical locking between load-breakswitch and earthing switch is possible.The earthing switches ...
Fritz Driescher & Söhne GmbH
Primary current: 2 A - 63 A
VAC: 400 V
VDC: max 220.0 V
Switches and push-buttons are components for switching consumers in industrial, commercial and private electrical installations, such as switch-disconnectors, impulse relays (remote switches) and main ...
Primary current: 20 A - 40 A
REFERENCE STANDARDS EN 60947-3 Low voltage switchgear and controlgear. Part 3: Switches disconnectors, switch-disconnectors and fuse-combination unit. EN 60529 Specification for ...
SCAME PARRE S.p.A.
Primary current: 0 A - 630 A
Gave introduces a new range of NH fuse switch disconnectors characterised by its wide range of size, modularity and scope of accessories. Functions NH fuse switch disconnectors ...
Primary current: 0 A - 63 A
VAC: 690 V
VDC: 440 V
module 4x NH fuse-switch-disconnector, 3-pole clamp connection 4x NH 000 (max. 63 A) for busbars 30, 40, 60, 80, 100, 120 x 10 NEW System 185Power Product group - 09 Subgroup - 37 pack ...
Wöhner
Switch-disconnector-fuse in strip-version in accordance with IEC/EN 60947-3, VDE 0660 Teil 107; - For coupling of two separate busbar systems - All parts of SASILplus made from halogenfree, self-extinguishing ...
JEAN MÜLLER
... indicated on both handle and switch. Door interlocking is provided by the handle.The design of the switch provides a direct connection on the switch terminals and is expandable with auxiliary ...
Primary current: 0 A - 800 A
3KF switch disconnectors with fuses meet all the requirements for main control, EMERGENCY-STOP, and maintenance switches. They are designed to systematically prevent electrical accidents. For example, ...
Siemens Low-voltage – Power distribution
15800 Fused Disconnect Switches for TPS Fuses Fused disconnect switch for use only with the following fuses; Main: Telpower® TPS 3 to 70 Amp, Alarm: ...
Primary current: 160 A
VAC: 690 V
... Standard of operation The NV strip sort wire switch-disconnectors are utilized as a part of combo with NV wire cartridges ensuring the circuit against shorts. The upper a piece of the NV strip-type fuse-switch-disconnectors ...
ETI
Primary current: 0 A - 800 A
VAC: 0 V - 4,000 V
The XMS is a modular off-load disconnect switch, packed in a closed insulated housing, that enables to build up to 3-pole independent or synchronized units. Used in railway locomotives and trains, the ...
Secheron
Primary current: 32 A - 1,250 A
VAC: 690 V
GLR series switch-disconnector-fuse( hereinafter called as switch for short) is a kind of multipole manual operation switch. It adopts DMC enclosure which has high dielectric ...
GREEGOO ELECTRIC CO LTD
Primary current: 1,200 A
VAC: 4 kV
The new SMC series of Telema disconnectors are based on revolutionary technology (distributed micro contact array) assisted by electronic contact control. This resulted in a dramatic reduction of internal parts quantity ...
As a market leader in the field of fuse links and fuse switches, and keeping with the philosophy of the company, “continuous development and innovation”, Pronutec presents the latest generation of vertical ...
PRONUTEC S.A.U.
Primary current: 10 A - 630 A
RDGLR Series Fuse Group Of Isolation Switch RDGLR series fuse group of isolation switch (called as switch for short) is a kind of multi-poles manual ...
Primary current: 8 A - 400 A
VAC: 15.5, 40.5 kV
... Statistics indicated that 70% – 90% of fuse cutout operations are in response to transient faults. The electronic sectionalizer enables customers to better manage these types of transient faults. It is designed to substitute ...
Zhejiang Farady Powertech Co.,Ltd
Primary current: 160, 250, 400, 630 A
VAC: 240, 290, 400 V
Federal Elektrik
Primary current: 100 A - 600 A
VAC: 14.4 kV - 28 kV
The type SF switch-fuse combination is ideally suited for providing circuit protection while the recloser is having maintenance performed on it, and when used in conjunction with one of Southern States ...
Primary current: 63 A - 630 A
QSA Isolating Switch Fuse Application Used to cabinet and drawer electrical controlling sets of equipment. Used as power switch isolating switch and emergency switch ...
Yueqing Zhicheng Electrical Equipment Co., Ltd.
Primary current: 25 A - 160 A
The MSW Switch-Disconnectors enable the manual drive of motors, machines and other equipment. Available in versions to mount on panel doors or base with currents up to 160A. The MSW Switch-Disconnectors ...
The HOPPECKE sun | fusebox is a convenient battery fuse switch with high safety standards as per DIN EN 50272-7. Wall mounting combined with strain relief for cables facilitate simple and safe installation. ...
Primary current: 160, 250, 400, 630 A
FUSE SWITCH-DISCONNECTORS – VERTICAL DESIGN Used for protection of electrical grid from short-circuiting and overloading. Intended for installation on collectors. Easily installed, take up little ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining