APPLICATION
Automatic monitoring of gamma-ray radionuclide specific activity directly in water reservoirs in the regions of nuclear weapons testing, near nuclear storage, nuclear power plants and other objects of nuclear energetics.
FEATURES
- High sensitivity of radionuclide activity detection;
- Full autonomy of measurement station data transfer via radio channel or cable channel into the point of information receiving, processing and archiving;
- Operation simplicity and system high reliability.
COMPLETE SET
- Floating monitoring station that is situated on the platform on pontoon and contains:
- Gamma-ray spectrometer based on submerged high purity germanium or scintillator detector;
- Transmitter receiver;
- Microprocessor device for interfaces necessary for automatic operation, self-diagnostic, calibration;
- Backup accumulators;
- Accessories for station control, calibration.
- Station for receiving, processing and archiving information including:
Radio station;
Decoding modem connection device with personal computer;
Software for spectra description, nuclides identification, calculation of their specific activity;
Device for information CD ROM recording.
- Metrological assurance, set of accessories and necessary instruments.
For additional information, please contact us: sales@bruker-baltic.lv
|
|
|
|
|
|
Gamma and X-ray HP(Ge) Spectrometer (Electrically cooled)
APPLICATION
The gamma%u2013ray Detection Device is based on a HPGe detector with Electric Machine Cooling which is intended for the conversion of Gamma-ray quantum energy using amplitude electric signals and their amplification for further registration with a nuclear physics apparatus. It was specifically developed for long, continuous operations.
FEATURES
- No liquid nitrogen necessary;
- Detection of radiation possible in any spatial orientation;
- Automatic restart after power supply switch-off;
- Long-duration continuous function;
- Coaxial or planar HP(Ge) detector can be used.
COMPLETE SET
- Detection device consisting of cryostat, HP(Ge) detector crystal, temperature sensor and heat exchanger;
- Gas compressor cooling system with built-in cryocontroller for the provision of automatic monitoring and control of operating modes for - HP(Ge) detector and cryosystem;
- High pressure gas pipes for connecting the cryosystem to the Detection Unit heat exchanger;
- Spectrometric device %u201CMultispectrum%u201D;
- Emulation and analysis Software.
For additional information, please contact us: sales@bruker-baltic.lv
|
|
- Electromechanical cooling
- Routine-maintenance free
- Small, lightweight, omnidirectional
cold head, may be positioned up to
50 ft from compressor.
- Transplantable "PopTop" capsule
technology allows user to "mix and
match" detectors and compressors.
- Operates 100/115/230 V ac at
50/60 Hz power
- Automatic restart after power failure
- CFC free
The EC-III Cryogenic Cooling option for HPGe detectors has been enhanced further. It now incorporates the
ORTEC patented1 "PopTop" transplantable detector capsule technology. This results in a highly flexible
solution to non-LN2 HPGe applications
|
|
|
|
|
|
HP(Ge) Planar Detectors GPD (Liquid Nitrogen cooled)
APPLICATION
Gamma and X–ray HPGe detector is intended for the conversion of Gamma and X-ray quantum energy to proportional level. This is accomplished using amplitude electric signals and their amplification for further registration with a nuclear physics apparatus. It is also intended for use as the gamma and X-ray detection component of radiological monitoring for environmental objects in nuclear energetics, industrial production, agriculture, medicine, etc.
FEATURES
- Possibility of choosing a preamplifier type with a resistive or opto-electronic feedback high energy rate up to 15000 MeV/sec;
- Ability to increase the energy rate to 20000 MeV/sec radiation detection in any spatial orientation depending on cryostat modification manufacturing in a portable cryostat;
- Possibility of transportation and storage without cooling.
COMPLETE SET
- HP(Ge) coaxial detector (p-type);
- Preamplifier with cooling input stage;
- Cryostat;
- Spectrometric Device;
- Analysis Software;
- Dewar vessel.
For additional information, please contact us: sales@bruker-baltic.lv
|
|
APPLICATION
A Coaxial HPGe Detector with Lead Shield is used to measure the specific gamma radiation of radionuclides from various types of environmental objects such as rocks, minerals, sludge, slag, soil, plant, sediment and particulate matter in air.
FEATURES
- Adopting precision gamma-spectrometry methods;
- Radionuclide identification and determination of their specific activity;
- Low level of instrumental background;
- Low threshold for radionuclide detection;
- Separate and simultaneous measurement of activity of 100 radionuclides.
COMPLETE SET
- Detection Unit based on 10% - 160% efficient HPGe p-type coaxial detector;
- Lead Shield for lower back signal with a support;
- Liquid nitrogen level monitor (LN2 Monitor);
- Spectrometric device “Multispectrum”;
- Emulation and analysis Software.
By special request detector chamber, holder and internal details can be made from low background materials.
For additional information, please contact us: sales@bruker-baltic.lv
|
|
HP(Ge) Coaxial Detectors GCD (Liquid Nitrogen cooled)
APPLICATION
Detection of Gamma-ray of environmental objects in nuclear energetics, products of industry and agriculture, medicine, etc.
FEATURES
- 10% - 160% efficiency HPGe p-type coaxial detectors are available;
- Energy range from 40 keV to 10 MeV;
- High efficiency of radiation detection;
- High energy rate up to 200000 MeV/sec;
- Excellent peak symmetry;
- Detection of radiation in any spatial orientation depending on cryostat modification;
- Manufacture in a portable cryostat is possible.
COMPLETE SET
- HP(Ge) coaxial detector (p-type);
- Preamplifier with cooling input stage;
- Cryostat;
- Spectrometric Device;
- Dewar vessel.
For additional information, please contact us: sales@bruker-baltic.lv
|
|
For computer-based analysis of complex spectra requiring the best in resolution, peak-to-Compton ratio, peak shape, and efficiency:
Large stocklist at all times
Efficiencies to 150%, higher on request
New "Application-Tuned" PROFILE Series available
PopTop flexibility
Excellent energy resolution
Excellent peak symmetry
Automatic high-voltage shutdown protects preamplifier input FET
Indicator warns of excessive counting rate
PLUS preamplifier option for ultra-high-rate applications
|
|
Portable HP(Ge) Gamma-ray Spectrometer
APPLICATION
Detection, accumulation and processing of gamma spectra in field and industry conditions were small dimension and weight of spectrometer are important.
FEATURES
- Ultra-light cryostat fabrication for minimum gamma absorption;
- Light weight aluminum construction;
- Detection of radiation in any spatial orientation;
- Compact low consuming electronics;
- Available with HP(Ge) coaxial or planar detector;
- Transportation and storage without cooling.
COMPLETE SET
- Portable HP(Ge) coaxial or planar detector;
- Portable spectrometric device;
- Portable PC with MCA emulation software.
For additional information, please contact us: sales@bruker-baltic.lv
|
|
|
|
|
|
The Triathler gamma counter is a compact, portable, manual instrument for counting gamma labels in the 10 keV .. 500 keV energy range.
Key characteristics:
- 32 x 32 mm NaI detector, through hole, well diameter 14 mm. Background shield 8 mm of lead
- 1000 channel Multi Channel Analyser
- Max sample diameter 13 mm.
- > 75 % counting efficiency for I-125
- Optimised to count e.g. radio-immunoassay and cytotoxicity
- Single or dual label counting with spillover correction.
- 32 character alphanumerical display
- RS-232 port to drive a PC or a printer
- Preset nuclides:I-125, I-129, Co-57, Cr-51, Cs-137, Co-58
- Software for MS WindowsR to download the results to a file or MS Excel worksheet is included
- Remote control of the Triathler via the RS-232 port
- Power input: 12V DC, 1.5 A or 100 .. 240 V AC, 50/60Hz
- Mechanical data: H 190 mm, D 330 mm, W 250 mm, weight 9 kg
Delivered with:
- Owner’s Handbook
- PC interface software
- RS-232- cable
Available options:
- Additional internal lead shield, thickness app. 6 mm, weight 6.5 kg
- Equipment and field cases
|
|
|
|
|
|
Portable Germanium (HPGe) Gamma-Ray Spectrometer with Integral LN2 Dewar
Standard holding times in the range 1- 5 days*
Available in all-attitude and compact multi-orientation dewar types
Lightweight: <11 lbs for 24-hour holding time version
Available for all GEM, GMX, SLP or GLP detectors
Automatic high-voltage shutdown and high count-rate indicator
SMART-1 detector option provides temperature monitoring when used in conjunction with DigiDART
PopTop and non-PopTop versions
16 engineering design improvements over previous models.
Gamma Gage II represents a series of engineering improvements over the highly successful Gamma Gage of which many thousands are deployed daily in portable high resolution spectroscopy applications. These improvements have been implemented specifically in response to requests from users of the original Gamma Gage.
Gamma Gage II is intended for most any situation in which it is necessary to "take the instrument to the sample."
Examples of such measurements are found in many waste assay and site characterization measurements, as well in nuclear materials holdup, and portable safeguards isotopic ratio measurements. In some cases, a Gamma Gage dewar is an excellent solution when space/weight is at a premium, for example, in Whole Body Counting applications or in some multi-detector research applications, although increasingly, electrical cooling is a viable alternative in these.
The integral LN2 dewar is available in a variety of hold times to suit the measurement constraints on size/weight and holding time.
|
|
SiLi X-ray Spectrometers (SXRD)
APPLICATION
Detection of X-ray radiation in energy range from 1 keV to 60 keV.
FEATURES
- Possibility of choosing a preamplifier type with resistive or opto-electronic feedback;
- High energy resolution;
- High count rate - 500 MeV/sec and ability to increase it up to 1000 MeV/sec;
- Thin Be windows, possibility to install ultra-thin polyimide windows;
- Detection of radiation in any spatial orientation depending on cryostat modification;
- Manufacture in portable cryostat, cryostats for XRF analyzers and electron microscopes is possible.
COMPLETE SET
- X-Ray detection unit based on Si(Li) semiconductor detector (SXRD) designed for X-Ray detection;
- Preamplifier with cooling input stage;
- Cryostat;
- Dewar vessel.
COOLING
SiLi X-ray Spectrometers are available with liquid nitrogen cooling or with Peltier cooling when liquid nitrogen is inconvenient or impossible to use.
For additional information, please contact us: sales@bruker-baltic.lv
|
|
|
|
|
|
For x-ray spectroscopy with a nuclear accelerator, radioactive source, or x-ray tube
Premium performance spectroscopy from 1 keV to 30 keV
Superior resolution performance at low and high count rates
Multi-detector arrays available for use at fusion facilities
Thin Be window
High peak-to-background ratio
PopTop flexibility
Figure 25. Detection Efficiency vs. Be Window Thickness
on Low-Energy Curve and vs. Crystal Thickness on
High-Energy Curve
Figure 26. Array, Comprising Seven Tightly-Packed
6-mm-diam Si(Li) Detectors, Used at Synchrotron Light Source
Figure 27. Examples of Multiple Detector Arrays for Soft X-Ray
Spectroscopy. Note the three Be windows in each endcap.
Three Si(Li) detectors share a common cryostat in each of the
systems shown.
Figure 28. 6-mm Diameter SLP Detector Element
ORTEC SLP Series Lithium-Drifted Silicon X-Ray Detectors provide the spectroscopist with a highly sensitive, premium performance research tool for detecting x rays from a nuclear accelerator, radioactive source, or x-ray tube. The energy range of detection (Fig. 25) is from 30 keV down to 1 keV, depending on the thickness of the beryllium window.
The x-ray detector consists of a lithium-drifted silicon crystal and a cryogenically-cooled-FET, a high-gain, low-noise hybridized preamplifier in a PopTop capsule with a thin Be entrance window. The ORTEC Si(Li) detector crystal is manufactured under an exclusive process. Special techniques for lithium drifting result in a negligible detector element dead layer whose characteristics will not change even if the detector is stored at room temperature.
|
|
Gamma Analyst Integrated Gamma Spectrometer
Turnkey automatic gamma spectroscopy instrument
Automatic sample changer handles multiple geometries simultaneously
Designed to count samples to sensitivities required by regulatory limits
Low background design
Straightforward lab oriented user interface dialog
Extensive QA record keeping built in
Connects directly to Ethernet network
Small physical dimensions for mobile or restricted space applications
Supported by a full suite of integration, installation, calibration and training services
|
|
|
Canberra Industries is the world's largest manufacturer of nuclear radiation detection and analysis systems. In order to better serve our customers worldwide, Canberra operates detector manufacturing facilities in the U.S. and in Europe. Canberra Semiconductor, N.V., which is located in Olen, Belgium, provides Ge detectors to the European market. In addition, C.S.N.V. manufactures a semiconductor detector for charged particles known as the PIPS (Passivated Implanted Planar Silicon) Detector. Detector Products Division, which shares the home plant in Meriden, Connecticut, provides Ge detectors to the world market outside Europe, and manufactures Si(Li) X-ray Spectrometers as well as a comprehensive line of shields and accessories for detectors and detector systems.
|
|
|
|
|
|
Si(Li) detectors, which cover the energy range from a few hundred eV to 50 keV or so, are used in a wide variety of applications including x-ray fluorescence, x-ray microanalysis, PIXE, EXAFS, x-ray diffraction, and M%uFFFDssbauer.
The finest in semiconductor technology and cryogenics, combined with advanced signal processing electronics give CANBERRA Si(Li) detectors solid performance and reliability. Unlike early Si(Li) detectors and unlike those manufactured by some companies today, CANBERRA Si(Li) detectors are stable at room temperature so they can be shipped and stored without LN2.
CANBERRA Si(Li) detectors are available in two versions. The standard detector uses conventional geometry and a gold surface barrier entrance window. The Super Si(Li) uses a proprietary geometry and entrance window. This, along with a special shaping amplifier, improves resolution by at least 10 eV (FWHM) and increases the peak/background by about ten-fold to greater than 10,000:1.
CANBERRA offers a full complement of signal processing and data acquisition electronics. The detector includes a low-noise preamplifier of the pulsed-optical feedback type. This pre-amplifier employs a specially fabricated FET which is cooled along with the detector in a cryostat.
|
|
CdZnTe/CdTe detectors
CdZnTe (CZT) is a room temperature semiconductor which allows to create X- and gamma-ray detectors with comparably high energy resolution and high count rate capability without cooling. Detectors performance allow to use CdZnTe detectors successfully in Nuclear Industry and Medicine, Safeguard and Homeland Security, many others industrial and laboratory applications.
Bruker Baltic develops and fabricates detectors based on CdZnTe/CdTe and accompanying electronics for them base on general electronic components and ASICs.
We are flexible in our technological processes and provide engineering design service and custom fabrication of small and medium volumes of devices.
Bruker Baltic develops and manufactures by request (custom fabrication) following detectors:
- Detector Linear Arrays
- Strip Detectors
- Pixel Detectors
- Co-planar Grid Detectors
- Single Detectors
For additional information, please contact us: CZT@bruker-baltic.lv
|
|
| ... products without technical information |
| |
|
|