Advanced Gasmitter
NDIR-Dual Wavelenth Principle
Type AGM 1010 for CO2 and CH4
OEM-Gastransmitter with improved characteristics
• NDIR-Dual wavelength sensor for gas measurement
• Low-grade drift characteristics
• Dual gas version or additional measurement range
• Fast response time
• Improved signal-to-noise ratio
• USB and RS485 interface
• Linearized analogue output: 4...20mA / 0...8V
• Display for measurement range deviation: 2...22mA output
• Temperature compensated
• Pressure compensation option
• Web based communication software
• Simple integration into analyzers and measurement systems • Versions for gas diffusion operation available
|
|
The GasCheck infrared gas sensor is a series of low CO2 sensors which features high accuracy, good long term stability, negligible cross sensitivity, small size and low power requirement.
The basic GasCheck is available in three ranges 3000 ppm, 3% and 10% with a 0 to 1 V non-linear output. A linearisation board can be added as an option to give linear 4 to 20 mA output.
The option of a diffusion assembly is available for the 3000 ppm unit.
Originally developed for measuring CO2 concentrations in laboratory incubators, the GasCheck range has now also been adopted for a wide range of applications where accurate measurement of CO2 is required, but with the benefits of low cost and compact design.
|
|
|
|
|
|
Figaro Pre-calibrated CO2 sensor modules combine Figaro's CO2 sensor TGS4160/ 4161 with a microcomputer and Figaro's proprietary signal processing technique.
With simple user-defined settings, this module generates a control signal for ventilation and/or air conditioning systems. The result is economic, long-lived, and maintenance free air quality control. When compared with traditional CO2 sensor modules using infrared sensors, Figaro's CO2 module is much more cost effective.
CDM4160 - Pre-calibrated CO2 modules
Suitable for indoor ventilation control and CO2 monitoring in factories, agriculture, and automobiles where conditions are more severe than in residential applications. Based on the specific needs of each user, models are available in three sensitivity ranges: 400-4000ppm, 400-8000ppm, and 400-40000ppm.
CDM4161 - Pre-calibrated CO2 module
Suitable for indoor ventilation control in residences and high occupancy buildings. Models with detection ranges of 400-4000ppm or 400-8000ppm are available to meet the specific requirements of your application.
* pre-calibrated
* maintenance-free
* linear voltage output corresponding to CO2 concentration
* control signal
* malfunction signal
|
|
NDIR Carbon Dioxide - Infared Sensors
Alphasense contemporary designed miniature CO2 infra-red sensors are self-contained, plug in sensors with integrated optics contained within standard sized miniature (20.0 mm) gas sensor housings. There are no moving parts within the sensors. An internal temperature sensor is included to enable the temperature to be monitored at the detectors, thereby providing the best means of compensating for temperature effects, including ideal gas law corrections.
CO2 Gas Ranges
IR-CO2-A1 Carbon Dioxide 0 to 5,000-ppm
IR-CO2-A1 Carbon Dioxide 0 to 5% Volume
IR-CO2-A1 Carbon Dioxide 0 to 20% Volume
IR-CO2-A1 Carbon Dioxide 0 to 100% Volume
|
|
The LED based CO2 NDIR sensor is a fast response, low power NDIR CO2 sensor. It uses patented Indium Antimonide technology to produce a solid state source/detector pair. This gives a fast response to changes in gas concentration, and high immunity to ambient light/heat sources.
Carbon Dioxide (CO2) is measured by recording changes in the transmission of mid IR wavelengths around the carbon dioxide absorption peak at 4.26um.
The C20 is fully solid state, using an advanced mid IR LED and photodiode pair.
This eliminates the need for heated filaments entirely.
This sensor produces a temperature compensated, linearised output via a serial line, and is extremely simple to integrate into microcontroller based instruments.
|
|
CO2 Sensor
The CO2 LC is a microprocessor controlled gas analyzer using non diffractive IR detection (NDIR) for determination of CO2 concentration. This low price CO2 sensor is characterized by low power consumption, a wide supply voltage range of 8 V . 15 V and simultaneous integration of current and voltage interface.
A microprocessor controls all necessary functions and performs calculations which allow fast customer specific adaptions by software variations. We offer different calibrations for varying concentrations of CO2: 10%, 11%, 30%, and 100%.
|
|
The Alphasense patented carbon dioxide sensor is a world first in CO2 monitoring:
Requires no power
Operates at room temperature
One sensor measures from 500ppm to 95% CO2
Small size
Low cost
Simple interfacing
Using the potentiometric measuring principle with our patented silver halide solid state electrolyte, this sensor does not have the high power requirement or high price tag of NDIR technology. This sensor is ideal where low cost and low power are critical for CO2 measurement.
This sensor is the result of seven years of research and development, and this work continues. While not as accurate as NDIR, and not suitable for IAQ measurements, this sensor is ideal for safety alarms, combustion gas monitoring and high CO2 process monitoring.
Contact us with your application. Evaluation boards are available.
|
|
The EE80 series combines CO2 , relative humidity (RH) and temperature (T) measurement in one housing. The snap-in mounting concept stands for easy installation and replacement within seconds.
EE80 series set new standards in CO2 measurements for HVAC. The operation is based on the infrared principle. A patented auto-calibration procedure compensates for the aging of the infrared source and ensures outstanding long term stability.
The basic EE80 version for CO2 and T can be easily extended with a RH plug-in module. The well proven E+E sensor technology guarantees accurate and long term stability.
|
|
|
|
|
|
The Vaisala CARBOCAP® Carbon Dioxide Probe GMP343 is a compact field instrument designed for soil respiration measurements, other ecological measurements and various custom applications.
The metal-cased GMP343 operates in harsh conditions: in temperatures -40...+60 °C (-40...+140 °F) and humidity 0...100 %RH. The GMP343 weighs less than 0.4 kg and consumes under 1 W of power. The probe uses the unique Vaisala CARBOCAP® silicon-based infrared sensor.
The diffusion-aspirated design eliminates the need for sampling systems and pumps. In soil respiration box measurements this design also eliminates errors caused by pressure differences often present in pump-aspirated measurement systems. The GMP343 is very stable, with 6 hour drift less than 1 ppm outdoors, and has as a short warm-up time.
The GMP343 can output numerically filtered or raw measurement data. Additional features include heated optics, compensation possibilities for temperature, relative humidity and pressure, and built-in self-diagnostics. In addition to the diffusion-aspirated version, the GMP343 is available as a flow-through version. The GMP343 can be powered and used with the portable MI70 indicator for convenient field measurement.
|
|
| ... products without technical information |
| |
|
|
|
|
The MYCO2 is a high performance infra-red gas sensor, designed for monitoring environmental CO2 in protected crops and demand controlled ventilation.
MYCO2 is a robust, low cost CO2 monitor, housed in an IP65 rated enclosure against the ingress of water and particulates. The monitor operates on a diffusion/convection principle and therefore no sampling pump is required.
This monitor can easily be wall-mounted.
For many years, Edinburgh Sensors has manufactured infra-red, dual wavelength sensors with a single optical path and without any moving parts. As a result, the sensor is highly gas specific, and insensitive to other gases and water vapour.
This ensures long term stability and accuracy over extended periods, removing the need for frequent re-calibration.
The MYCO2 sensor can be customised to suit specific applications, placing the design control in the hands of the system designer. The user selectable functions include linear analogue output options, alarm function software and automatic temperature correction.
The MYCO2 sensors are aspirated by a combination of diffusion and convection within the sensor head. This gas sampling method is silent, reliable and provides a fast response time. Convection is used to circulate gas between the sensor head and the diffusion cell with gas exchange occurring, by diffusion, at the surface of the diffusion membrane. Since the gas in the cell circulates within a closed system, all optics are protected from the ingress of dust. No additional pumping or filtering of the gas is necessary.
|
|
From fermentation through to distribution, Carbon Dioxide is one of the most common hazards to health in breweries, cellars and drinks outlets.
It is also the fourth most abundant gas in atmosphere; Long term exposure to only 0.5% volume represents a toxic health hazard.
Concentration greater than 15% volume can lead to death.
CellarSafe has been specifically designed
to warn personnel of these hazards and features both long life sensors and remote warning panels (whcih can for example be installed behind a bar as well as at the entrance to the cellar).
|
|
Novel infrared measuring system for CO2
With an infrared sensor (IR sensor) specifically for carbon dioxide.
The infrared measuring system detects the carbon dioxide content of the ambient air fast and precisely. It contains a novel infrared measuring system functioning basically like a conventional two-beam photometer.
However, since material and construction of the sample cell are novel, and the measured signals are evaluated and processed according to a new digital algorithm, the infrared measuring system is light-weight, compact, in normal applications maintenance-free and long-term stable but nevertheless affordable.
The infrared measuring system detects the absolute carbon dioxide content of the ambient air (partial pressure), monitors itself constantly and signals malfunctions of its hard and software. The whole measuring range is linear.
|
|
The GMT220 transmitter series is designed for a wide range of industrial carbon dioxide applications including greenhouses, fruit storages, safety alerts and demand-controlled ventilation in mushroom farms, livestock husbandry and parking garages.
The GMT220 transmitters measure carbon dioxide in harsh and humid environments. The housing is dust and waterproof to IP65/NEMA4. The materials have been chosen for extended corrosion resistance.
The GMT220 transmitters are easy to use and install. The transmitters have a modular structure which includes a separate mounting plate for easy installation.
Interchangeable probes facilitate field maintenance. The probes can simply be replaced with newly calibrated ones, or with separate probes that are only used as a reference for calibration checking. This minimizes downtime and eliminates the need for expensive calibration equipment.
|
|
Besides pH and dissolved oxygen measurements, reliable monitoring and control of the CO2 partial pressure is important for successful fermentation. The oxidation of carbohydrates to CO2 water results from aerobic respiration. METTLER TOLEDO's new CO2 measuring system is specially designed for in-situ measurement into a bioreactor and therefore "registrates" exactly the same partial pressure as the cell.
METTLER TOLEDO offers a wide range of different measurement systems for very specific requirements in different industries consisting of sensors, housings, transmitters, services and fulfills all high quality requirements.
|
|
Thermo Scientific's Model FX-CO2 single gas detector/transmitter uses an NDIR (non-dispersive infrared) sensor to detect carbon dioxide (CO2) in the workplace. The sensor and electronics are mounted in a NEMA 4X fiberglass surface mounting enclosure.
Features:
- Uses an NDIR (non-dispersive infrared) technology
- Industry standard, 4 to 20 mA output
- Housed in rugged, weather proof case, suitable for indoor or outdoor installation
- Excellent long term stability
- User friendly - simple to operate
- Economical
- Splash resistant NEMA 4X
- Diffusion and flow-through version available
|
|
| ... products without technical information |
| |
O2 and CO2 are the gases whose rates of consumption or production are most frequently measured for the purposes of study and process control (energetic metabolism, substract utilisation, etc.).
The measuring ranges of the GA analyser (0÷10 or 15% for CO2, and 21÷10% for O2) have been chosen specifically for your application.
The system is based on wellproven, high quality transducers, and is characterised by an extremely reduced internal volume, to reduce overall response times.
|
|
| ... products without technical information |
| |
|
The original "clean" agent, carbon dioxide suppresses fire without leaving behind an agent to damage sensitive equipment. And because there is no agent to clean up, you're back in business faster. To provide the most economical system arrangement without sacrificing performance, we offer both High and Low pressure systems including the exclusive ANSUL® "Mini-Bulk" tank technology.
|
|
|
|
|
|
Hygood Carbon Dioxide Fire Suppression System
A fire in your facility is never pleasant. But, it doesn’t have to be debilitating. Carbon dioxide, the original 'clean agent,' is still an economical solution, providing automatic or manual protection for Class A, B or C fires.
The only gaseous agent capable of deep seated Class A hazard protection, versatile Co2 can flood enclosed areas or discharge directly onto burning surfaces.
Hygood High Pressure Carbon Dioxide Systems are especially effective for non-occupied hazards such as semiconductor wet benches, control rooms and paint lines. Whatever the application, from cylinder to nozzle, each system is custom-designed for your specific fire hazards.
Hygood Co2 systems have been proven effective in numerous non-occupied applications:
• Commercial and industrial fryers
• Dip tanks
• Electric generators
• Electrical panels
• Marine applications
• Spray booths
• Waste disposal equipment
• Gas turbines
• Coal silos
• Hazardous material storage
• Quench tanks
• Semiconductor wet benches
• Computer room subfloors
• Non-occupied control rooms
• Paint lines
• Wave solder machines
• Machining operations
• Hose reel stations
• Transformer vaults
• Dust collectors
• Printing presses
• Inerting systems
|
|
REVEN*-0-MAT
The fire-extinguishing system REVEN®-0-Mat was developed -► for the automatic fire protection of deep fryers, fryers and grills in kitchens.
In addition, REVEN®-0-Mat protects the extraction hoods and exhaust air ducts. The system consists essentially of an extinguishing agent container and an automatic trigger ANSUL AUTOMAN including the pertinent pressure reducer. The components are fitted in a single enclosure. Nozzles, detectors, solders and guide rolls are delivered as a complete unit.
|
|
CS2-A - CARBON DIOXIDE FIRE EXTINGUISHER
CS2-A is a carbon dioxide (CO2) fire extinguisher with lever valve. Certified according to the Pressure Equipment Directive PED 97/23/EC, Marine Equipment Directive MED 96/98/EC and CEN EN3. Capacity is 2 kg.
CS2-ML - CARBON DIOXIDE FIRE EXTINGUISHER
CS2-ML is a carbon dioxide (CO2) fire extinguisher with lever valve and front horn. Extended operating temperature range ?30 °C + 60 °C, therefore suitable for use in lowtemperature countries. Certified to the Pressure Equipment Directive PED 97/23/EC, Marine Equipment Directive MED 96/98/EC and CEN EN3. Capacity is 2 kg.
|
|
CS5-A - CARBON DIOXIDE FIRE EXTINGUISHER
CS5-A is a carbon dioxide (CO2) fire extinguisher with lever valve. Certified according to the Pressure Equipment Directive PED 97/23/EC, Marine Equipment Directive MED 96/98/EC and CEN EN3. Capacity is 5 kg.
CS5-ML - CARBON DIOXIDE FIRE EXTINGUISHER
CS5-ML is a carbon dioxide (CO2) fire extinguisher with lever valve. Extended operating temperature range - 30 °C + 60 °C, therefore suitable for use in lowtemperature countries. Certified to the Pressure Equipment Directive PED 97/23/EC, Marine Equipment Directive MED 96/98/EC and CEN EN3. Capacity is 5 kg.
|
|
Carbon Dioxide extinguishers are suitable for class B risks involving flammable liquids and are best choice for general electrical hazards. CO2 is harmless to electrical equipment and is ideal for modern offices, electronic risks and fires causes by the combustion of liquids such as oils, fats, solvents, etc.
The 2kg size has a 55B fire rating and incorporates a “safe to hold” horn which not only gives a benefit from increased performance but also prevents frost burn to the user. The carbon dioxide used is a recovered industrial by-product, thereby reducing the carbon levels contributing to the greenhouse effect.
|
|
|
|