PM100-G - Fiber Optic Power Meter
Simple optical power and loss measurement
PM100-S - Fiber Optic Power Meter
Simple optical power and loss measurement
PM200 - Fiber Optic Power Meter
Link certification and reporting tool
FO600 - FiberMeter Optical Power Meter
FO610 - High Power FiberMeter Optical Power Meter
Ideal for testing and certifying in both Multimode and Single Mode applications
|
|
| Luna Technologies' Optical Backscatter Reflectometer (OBR) delivers unprecedented inspection and diagnostic capabilities for the fiber-optics industry. Luna's state-of-the-art OBR provides isolation of faults and problems well before final test, saving hours in rework and hard dollars in yield loss. |
|
| The OP510 was specifically designed for applications where cost effective solutions for measuring, monitoring and logging of insertion loss or power fluctuations are needed. The OP510 is a small (4"x2"x1.25") desk friendly module designed such that minimal movement and bending of the reference- and test cables is necessary. This results in stable, accurate and repeatable measurements. |
|
| Insertion loss (IL) and return loss (RL) on fiber optical components are measured fast and accurately with the OP930. The return loss is measured with the "no mandrel" method, meaning neither matching gel nor mandrel wraps are required at the far end of the cable. The insertion loss is measured by utilizing the stable transmitter of the return-loss as the source in combination with the precision optical power meter. |
|
| ... products without technical information |
| |
| The B&K Precision Model 889A Synthesized In-Circuit LCR/ESR Meter is a high accuracy test instrument used for measuring inductors, capacitors and resistors with a basic accuracy of 0.2%. Also, with the built-in functions of DC/AC Voltage measurements and Diode/Audible Continuity checks, the Model 889 can not only help engineers and students to understand the characteristic of electronics components but also being an essential tool on any service bench. |
|
| Agilent LCR and resistance meters are useful in testing components and materials in a variety of research and design applications and in component manufacturing. LCR meters measure impedance (inductance, capacitance, and resistance) at spot frequencies. Resistance meters are optimized for high-resistance or low-resistance measurements. |
|
| The LCR Meter measure passive components with as little as 0.05 % error. These easy-to-use instruments are quick to setup, adjust and calibrate. The SR715 and SR720 are ideal for applications such as incoming inspection, quality control, automated test, and general benchtop use. |
|
Measuring Instrument - LCR Precision Instruments ( LCR200) :
Key Features:
- Measurement Parameters : Z , Ls , Lp , Cs , Cp ,
DCR , ESR , D , Q , and (Theta)
- Test conditions : 100MHz , 120Hz , 1KHz , 10KHz , 100KHz , 200KHz ; 1Vrms , 250mVrms , 50mVrms , 1Vdc(DCR only)
- DMM Functionalities
- Dual LCD Display with LED backlit
- Open / Short calibration
- Remote binning capability
- Auto range / range hold selection |
|
- LCD Display 128 x 64
- File Management ( Flash Memory Card)
- Test Point Range : 64-2048
- Test Voltage : 50-1500VDC (RT-9651 H / CH )
- Insulation Test : 500K-1000MOhm(RT- 9651H/ CH)
- 4-Wire Rsistance Test : Yes
- Components Test : Resistor,Diode,Capacitor(Option)
- Resistor Measurement : 0.1Ohm-20MOhm
- Capacitor Measurement : 100pF-1000uF
- High Quality Relay |
|
1. 320x240 dot-matrix display
2. Test frequency range : 20Hz - 1 MHz
3. Measurement parameter |Z|, Rs, Rp,Xs, Rdc|, |Y|, Gp,
Bp, Ls, Lp, Cs, Cp, D, Q , Theta
4. Basic Accuracy ± 0.1%
5. Measurement Time : 30 mS ( Fast )
6. Bin Function : 8 bins (expandable to 15 bins)
7. Comparator function: Primary / Secondary
8. Memory : 256 instrument setups
9. External Memory interface (Option)
10. Interface : Handler,( Option : GPIB, RS232 ,Printer )
11. Deviation Zero : Open / Short
12. DC Bias (Option) |
|
| ... products without technical information |
| |
Stop Time Measuring Instrument for safety measurements at power driven machines such as presses, shears and robots. The system is used to calculate the distance of the safety device. (2-hand control, light curtain ..)
Portable and solid equipment, built-in matrix printer
Free adjustable stop point
Standstill detection down to v < 1 mm/s
Measurement of maximum velocity
Measurement of velocity at stop point
ISO9000 calibration certificate
Traceability of measurement values
RS-232 interface for PC connection
Fast set-up time
Actuator to release no-touch safety equipment as option |
|
The Stopping and Motion Analyser is designed to enable key Safety Critical machine parameters to be easily checked.