The SSM heater plate can be used for frost protection and as an anti-condensation heater. Its application ensures complete operational safety as the plates prevent malfunctions often due to leakage currents on electrical installations or the corrosion of metal components. Typical applications are switchgear and controlgear cabinets, instrument housings, analyser cases, glove boxes and other enclosures.
Structure
The heater plate consists of a thin, anodised aluminium baseplate, vulcanised with siliconeimpregnated glass-fibre mats with an embedded heating coil. A bimetallic switch integrated in the terminal block limits the surface temperature of the heater approx. +70 °C. An alternative version is available for adjusting the surface temperature from +30 °C up to +150 °C.
Features
* Space saving thanks to its flat structure
* Good and uniform heat distribution thanks to the uniplanar structure
* Random mounting position
* Excellent resistance to chemicals
|
|
Band heaters
Electric heat - generating sleeves of any kind, provided with insulations made of mica or ceramics, available in any size and power.Possible applications: with presses ...
|
|
Coil heaters
High quality minitubular heaters that assure the best with respect to safety and performance.
|
|
SILICON HEATING PANELS - for complicated shapes and sizes
Silicon Heating Panels provide external heating to surfaces of any complex shape and size. Being totally water resistant they can be used both indoors and outdoors. They are used for removing moisture, dehumidification of motors & control devices, for battery heating in high-altitude aircrafts, gas turbines, medical equipment & food equipment. They can also be used in petrochemicals, pharmaceuticals & chemical industries
Construction
Silicon Heating Panels comprises of resistance wire-wound heating elements embedded in thin, lightweight fiber glass cloth - Silicon rubber composite substrates, forming a very flexible and high strength heating panel. For convenience of installation, pressure-sensitive adhesive backing are provided on one side of the heating panel. For minimum heat losses these should be backed by thermal insulation pads.
|
|
|
Diff-Therm Platen Heaters are high-quality tubular heating elements swaged under 50 tons of pressure into grey iron castings. For 25 years, Diff-Therm heaters have set the standard for long-life, evenly distributed process heating and efficient power generation.
|
|
BS heating cord
Designed to be used in condensate draining pipes, in negative cold rooms.
Available in 40W/m power, BS heating cords have a sole cold lead at one end.
Advantages :
Very flexible, can heat continuously.
|
|
. Industry : To warm surfaces and volumes (freezing industry, electronics, automotive, telecommunications, pharmaceutics...).
. Household appliances : Flexible heating elements for domestic equipments (refrigerators, freezers, small domestic appliances).
. Oenology : Must-warmer.
|
|
At ECAS, we are expert manufacturers of crankcase heaters.
The BCC it's an electricserial resistance protected with a metal braid, fixed to a flexible strap with an adjustable traction device which allows the crankcase heaters to be adapted easily to the object to be warmed.
Specially designed for the controlling and maintaining the temperature of compressors, boilers, storage tanks, etc.
Insulation resistance: 100 mega ohms min. at 2,500 V
Connection outlet: hose 3 x 0.75mm² - 1m
Tolerance W: ±10%
|
|
U.L. Recognized - Guide SEOT2, file SA4093 for use in air conditioning equipment.
C.S.A. Certified - Guide 165-E-90, file 016386-0-000 for use in air conditioning equipment.
Applications:
Crankcase heaters are used to overcome the problem of migration and condensation of refrigerant in the crankcases of compressors used in air conditioning and heat pump systems.
They are designed to keep the crankcase oil at a temperature higher than the coldest part of the system to prevent migration.
Features:
Hotwatt Crankcase Heaters are constructed of the highest quality corrosion
resistance materials and sealed against moisture.
The following list Hotwatt Crankcase Heaters by the OEM manufacturer. In addition, custom designed crankcase heaters and variations to the units shown are also available.
|
|
DE-FROSTING CB HEATING CORD
Application :
. Heat pump evaporator defrosting.
Technical data :
. Standard power : 30 W/m
. Standard voltage : 230 V
. Regulation :
preset +5°C thermostat included
. Standard lengths (1m multiples) :
from 1 to 6m
Advantage :
. Heating and regulation functions combined in a sole component.
Option :
. Tinned copper braid (with earth lead).
|
|
Industrial heating tape
Applications :
. heating and temperature maintenance of pipes, valves, tanks, etc ...
. unclogging of hoppers.
. freeze protection of huge equipments.
. laboratories.
advantages :
. heating tape ready to install.
. high flexibility for elaborate shapes.
. good resistance to humidity.
technical data :
. standard linear output : 150W/m
. standard voltage : 230V-50/60 Hz
. other voltage : on request
. standard lengths : 2m, 7m and 12m
. supply cable : H07RNF L2m
. max. exposure temperature : 180°C
. max. maintenance temperature : 150°C
|
|
HEATING WIRE IC RANGE - for cold room doors and refrigerated showcases
Applications :
. Framing of cold room doors and negative cabinets
. Doorstep of cold room
. Demisting of refrigerated showcases
advantages :
. No over-thickness at junctions heating part/cold leads
. Heating part and cold leads are mechanically and electrically shielded
caractéristiques techniques :
. Maximum maintening temperature (power ON) : 140 °C
. Maximum exposure temperature (power OFF) : 180 °C
. Standard power : 30W/m
. Standard voltage : 230 V
. Standard lengths (multiple of 0.5 m) : from 1 to 8 m
. Tinned-copper braid from one end to the other end
|
|
|
RMB self-thermostated heating tape is a ready to use heating tape ; you do not need any tool to lay it and you save 40% laying time in comparison with other heating tapes.
|
|
Self-limiting tape is available in 2 different outputs: 15 W/m and 20W/m:
• RAG15 self-limiting heating tape (15W/m at +10°C) is delivered in 100m drums to be cut and connected on site ; main use is to prevent frost from pipes. It is water and sun resistant ; aluminiupm tape and earth lead make electrical screening.
• RAG20 self-limiting heating tape (20W/m at +10°C) is delivered in 100m drums to be cut and connected on site ; main use is to prevent frost from pipes or tanks; it can be used also to prevent snow from roofs and gutters. It is water and sun resistant ; aluminiupm tape and earth lead make electrical screening.
|
|
Silicone rubber is a rugged, flexible elastomer material with excellent temperature properties. It is most suited to larger heaters and industrial applications.
- Rugged construction provides high reliability in a wide range of heating applications.
- Optional custom profiled heat density creates a uniform heatsink temperature which can improve processing yields.
- Factory vulcanization and high temperature capability allows higher wattage levels for faster processing.
- High temperature capability to 235°C (455°F)
- UL component recognition available
- Resistant to many chemicals
- Not suitable for radiation, vacuum, or prolonged exposure to oil
- Most economical in large sizes
|
|
The versatile Watlow cable heater can be formed into a variety of shapes as dictated by its many applications. These small diameter, high performance units are fully annealed and readily bent to your desired configuration.
Applications
Plastic injection molding nozzles
Semiconductor manufacturing and wafer processing
Hot metal forming dies and punches
Sealing and cutting bars
Restaurant and food processing equipment
Cast-in heaters
Laminating and printing presses
Air heating
Heating in a vacuum environment
Textile manufacturing
|
|
Characteristics: A complete range of heating cables, heater strips, woven resistors, drain cables, heat-trace cables, and cables for underfloor heating.
Applications: Refrigeration (reach-in refrigerators, refrigerating compressors, cold rooms, refrigerated units), construction (floors, gutters, roads), industry (petrochemicals, agrifood, aerospace), rail transport (points, trains, metro systems), other (wind farms, aquariums).
Brands: FLEXCORD, FLEXUNIT, FLEXDRAIN, FLEXTAPE, STPGEL, ANTIFREEZE, FLEXFLOOR, FLEXBELT, FLEXMAT, FLEXPLATE, FLEXDRUM, FLEXKIT
|
|
|
|
|
|
hotspring® spike-system a clamping mechanism of a special class.
For numerous applications – e.g. in the PET-processing industry, the hotspring® spike-system offers many innovative advantages: The low wall thickness of the clamping tube of only 2 mm, the fixing by easy sliding and turning on the nozzle as well as the front assembly and disassembly are arguments which save costs and time by this easy handling. Furthermore the „hotspring® spike-system“ guarantees optimal thermal features of the fixed hotspring® -coil heater (type WRP).
The principle of the „hotspring® spike-system“- consists of a reflection tube which by simple twisting along the total length can be adjusted to the tool to be heated. By this ideal adjustment to the tool an optimal heat transfer can be ensured, the maximal sheath surface load increases to 10W/cm², makes the by-pass of tool diameter tolerances of several 1/10 mm possible and guarantees a strong fit which does not need additional fixing.
The „hotspring® spike-system“ covers a wide range of requirements of small designs with a minimum tool diameter of 10 mm and a minimum length of the clamping element of 40 mm. Furthermore this system can be used for clamping hotspring-heating elements with larger dimensions.
|
|
Heatflon® Serie PH 1 - 9
Heatflon® heaters of the PH series consist of a stainless steel tubular radiator sheated in PFA. The head of the heater is made of PTFE and the connecting cable of PFA. Heating zone, head and connecting cable are welded together watertightly as a result a complete immersion in aggresive media is possible.
All devices of the PH series are earthed and approved by association of German engieers (VDE).
As an optional extra, all heaters can also be pre-equipped for a thermal monitoring. Users who purchase a special controller are then able to monitor the internal temperature between the stainless steel heater and the PFA tube, thereby reducing substantially the risk of fire. Heatflon® tubular radiators of the PH series are available for various surface loads, eg:
2,2 W/cm² - 1,5 W/cm² - 1,0 W/cm², applicable dependent on the specific media.
|
|
|
|
|
|
Our ATP Operation designs and manufactures custom heater assemblies that utilize solid-state PTC thermistor elements. PTC thermistors are truly remarkable for their ability to function as a self-regulating heating element and this characteristic makes them ideal for a wide range of heating applications. Because of the resistance versus temperature characteristics of PTC thermistors, the power consumed is nearly independent of voltage, ambient temperature, dissipation conditions and other parameters and these heating elements require no thermostat or additional control. PTC heaters can be combined in a variety of ways to heat flat surfaces, cylindrical areas and others shapes and sizes. Spectrum Sensors provide a variety of value-added services, such as extension leads and isolating the heating elements electrically in order to provide a finished solution that a customer can use right out of the box.
Features
• Configurations include discs, rectangles, squares, cylinders and various shapes with holes to increase the surface area of the heating element
• Multiple PTCs can be joined in parallel to provide constant heating over a larger area
• Virtually unlimited life
• No moving parts
• Highly efficient
• Extremely cost effective
|
|
Ultra flat silicon elemets for application maximum 200°C .
Minimum thickness 0.8mm , with adhesive and Available in low voltage or std voltage.
Available with termal cut-out .
|
|
|
Parallel heating cable constant power, is the best solution for all these situations where special electric heating system is needed: electric floor heating, electric radiant floor for ramps, electric trace heating for pipes, electric trace heating for storage tanks, snow melting systems for ramps, access, roads, systems, snow melting systems for roofs, terraces, gutters, pipes, etc., electric heating for animals: pigs, pets, exotic animals habitats, electric heating for agriculture: small greenhouses, terraces, seedbeds, etc.
|
|
INTERTEC offers the widest selection of explosion-proof heaters worldwide. - CSA/NRTL approvals for America
- ATEX/CENELEC approvals for Europe
- GOST approvals for the Russian Federation
Many other national certificates, e.g. for Japan, the Czech Republic etc.
- For freeze protection
- Installation in a horizontal or vertical position
- Choice of many different wattages
- Self-limiting or with thermostat in the connection cable allowing for quick and easy installation
- Fully factory sealed with silicone, protection degree to IP 68, reliable even in the harshest conditions
- Low thermal stress for long life
- Optional failure alarm
|
|
Heating wires made of PVC , Silicon , PTFE , fiber glass, fitted with tube and aluminium sheet supportse . For application maximum 450°C available in sigle and double insulation.
Available in in bobbins or cut . On request all products are supply with faston .
|
|
|
|
|
|
In ECAS we manufacture heating cables, parallel or serial, applicable to all those situations where heating is needed.
Model CTCS, parallel heating cable constant power, allows to be cut on site.
Characteristic
Current: 125V, 230V, 380V
Power: 10-50 W/m
Conductor surface: 2 x 0.75 mm², 2 x 1.5 mm² y *2 x 2.5 mm² (*Unique on the Spanish Market)
Insulation between conductors: Silicone
Outer covering insulation: Silicon, P.V.C, metal screening, etc.
Supply
.In reels from 100 to 500 metres
.In sections with lengths adapted to any project, ready to be installed.
Model RFS and RFSS, electric flexible serial resistance
Characteristic
Operating voltages: 12v, 24v, 48v, 110v, 125v, 230v, 380v... 750v.
Power output at 230 V: 8 to 60w/m
Maximum operating temperature: 180ºC
Maximum circuit length: According to model
Heating conductor: Ni/Cr 80/20
Core : Woven glass fibre
Type of insulation: Thermal Silicone, Glass fibre, P.V.C, etc.
Supply
.In reels.
.In groups already finishes, according to longitudes.
.With diameter of the Isolation: 2,9mm, 4mm (normalized), 5mm, 6mm.
Applications
Electric radiant floor, snow melting systems for ramps, roofs and gutters, trace heating for pipes and storage tanks, drum heaters, etc.
|
|
Applications:
Radiation heaters, vacuum technology, submersible heaters, containers, valves, pumps, forms, process and plate heaters.
|
|
|
|
|
|
At ECAS, we manufacture heating cables and flexible electric elements, for temperature control systems in networks of pipes.
The main purpose of pipe tracing is to avoid and compensate for the loss of heat certain fluids undergo during particular production processes.
Of utmost importance is that the fluid or product flowing in the pipes does not freeze, change viscosity, or harm the piping network.
For sanitary hot water systems, our pipe tracing system avoids the cooling of the water, especially when it is not moving, avoiding the spread of Legionnaire disease.
Heating cable:
For pipe tracing projects we recommend constant power parallel heating cable, model CTCS.
The parallel heating cable has a constant lineal wattage even when it is cut to required length.
Control and regulating :
We have different types of control and temperature regulating solutions, which are adaptable to all kinds of projects, and/or the needs of our customers.
Below are some of the control systems:
DPA: Control and regulation box to connect between 1 and 4 circuits, from 8A to 63A at 230V.
EWDR 902 - T: Digital Thermometer/Thermostat.
ETV - 1991- P: DIN/Omega rail electronic modular analogue thermostat.
ETN - 2P - 1441: DIN/Omega rail electronic modular analogue thermostat with mini-switchboard.
|
|
Application Pontencial:
Submersible heaters, containers, valves, pumps, form, process and plate heaters.
This mineral-insulated heating cable with a braiding of high grade stell 14541 is applicable within extreme corrosive and damp surroundings. The HIL heating cable is extremely robust and easy to bend. The stainless stell brainding is waterlight, oiltight and gastight. An utilisation temperature of up to 800°C enables a variety of applications. The cold end of the heating cable can be fed into a terminal box and connected by means of a MX20X1.5 screwed connection.
|
|
|
The tubular sheathed element is a quasi universal solution used for the heating of solids, liquids or gaz via JOULE EFFECT up to about 800°C. It can operate as immersion heaters for the fluid heating through natural or forced convection located in bores or flanged against a metallic part, the sheathed element allows the transfer of its energy via conduction or radiation.
|
|
|
Heat mildly corrosive solutions (pH5 to pH9) using stainless elements and a passivated stainless pipe body. Low watt density INCOLOY® sheath elements coupled with a passivated Stainless Steel pipe body provides long service life when heating highly corrosive solutions and sulfur laden oils. INCOLOY® elements and a Stainless Steel vessel enhance safe operation to nearly 1400°F outlet gas temperature in air, gas, or steam superheating applications.
|
|
|
|