|
|
Evaporative humidifiers provide very economic humidification as, unlike steam humidifiers, the water does not need to be heated. JS' evaporative humidifier range includes models that fit inside ducts/AHUs as well as units for suspended ceilings.
Running costs can be 150 times less than steam systems requiring only a single phase power supply. Many operating features make these humidifiers extremely hygenic and safe to use.
|
|
The Condair Fast Fog high-pressure humidifiers are applied for the humidification of supply - and re-circulated air in industrial, commercial and public buildings. Due to the high humidification efficiency the Condair Fast Fog is also used for adiabatic cooling of exhaust air in air conditioning systems.
|
|
Bowman charge air coolers are popular for test bed engines.
They can also be used for marine turbocharged engines.
The range is suitable for use on engines up to 380 kW or 500HP
|
|
Off line oil / air blast cooler BNK series
Integrated circulation pump
Low noise emissions
Easy to maintain
By-pass also available
High performance off-line coolers with compact dimensions, motor with two spindles for pump and fan. Matrix easy to dismantle. |
|
Oil/air heat exchangers
type LKI
Low noise level
High performance
Low cost
Product description
With this new generation of Universal Hydraulik LKI oil-coolers, the manufacturers have succeeded in reducing the noise level. These coolers are ideally suited for stationary installations - for the cooling of hydraulic or lubricating oils. The range has been extended to include slow-running ventilators, and the housings have been optimised, in order to produce the very low noise level. In order to make the cooler range as comprehensive as possible, the smaller models are also available as single or dual versions, thus covering oil-cooling requirements for both low and high oil throughflow volumes.
Product features
Testing pressure: 26 bar static according to DIN 50104
Operating pressure: 16 bar
(min. 2 Mill. Cycles from 0-16 bar at 2 Hz and 60 °C)
Compact oil-cooler
High operating pressure
High cooling performance
Low pressure loss
Max. operating pressure: 120 °C
High flexibility
2" SAE flange from LKI 700 upward
Also for use with water/glycol
Variable motor; Hydro / 12/24V |
|
| RFC and RFI chillers are used for cooling of little process and machines. With pump and tank intergrated they are very compact and easy to use. |
|
AIR-OIL HEAT EXCHANGERS -SERIES AP WITH HYDRAULIC MOTOR :
This type of exchanger has been designed for use on movable machines where battery feed is insufficient or when exchangers with direct current supply are inadequate to produce high thermic yields. The radiative unit is of aluminium because this material is a very good conductor; providing high thermic yields and relatively compact over-all dimensions. Thanks to the particular construction of the radiative unit the exchangers of the series APL cope well with water hammer conditions which, at peak values, must not exceed the minimum allowable dynamic pressure of 20 bar. The maximum allowable static pressure is of 35 bar. |
|
Oil/air heat exchangers
type LKI-HYD
Low noise level
High performance
Low cost
With this new generation of Universal Hydraulik LKI oil-coolers, the manufacturers have succeeded in reducing the noise level. These coolers are ideally suited for mobile installations - for the cooling of hydraulic or lubricating oils. |
|
Oil/Air Heat Exchangers
Very low noise level combined with low costs in the model ranges
- LKI
- LKIHYD
- LKM
Up to 26 bar oil pressure, cooling capacity from 1.5 to 150 kW, respectively from 20 to 700l/min, oil flow. Optionally with bypass valve for pressure peaks. Various electric motors available. |
|
Setrab Oilcoolers
Setrab´s cooler program is designed for flexibility and performance. This means that our product range achieves superior applicability for our customers, and we can devise the best possible solution to suit the conditions dictated by the customer´s application. We can therefore offer our customers the right product for every occasion. Quality has top priority for Setrab. For us it is natural that quality is the guiding star when it comes to service and design, as well as production and distribution, to achieve the result the customer expects. We are working towards the highest quality on all levels within the organisation and the continuous development of our quality assurance system is a process that engages all of our employees.
Setrab's STD, SLM and CP air cooled oil coolers |
|
Outstanding price-performance ratio
Air-water coolers are compact industrial cooling systems cha-racterised by a very special price-performance ratio. The cooling units are primarily used in applications where cooling to no more than 5 to 8 °C above the ambient temperature is required. The units are robust, uncom-plicated, technical refined and absolutely reliable in operation as all components are perfectly matched to one another, with all piping and wiring completely connected.
Eco-friendly yet cost-effective!
As freshwater is no longer needed, the costs for water supply and wastewater are dis-pensed with.
A consistently high cooling-water quality
is guaranteed by the closed cooling-water circuit, protecting the cooling channels against pollution and lime deposits.
Heat exchanger
The louver package is a parti-cularly robust design compri-sing copper pipes with alumi-nium louvers.
Pump and ventilator
Centrifugal immersion pump, housing and impeller made of brass, shaft made of Grade 1.4057 special steel. The ventilator wing is mounted on the free shaftend of the pump.
Tank
Tank made of welded and matt brushed VA sheet, Grade 1.4301.
|
|
Long and secure functioning Setrab STD Oil Coolers are used in applications with low to medium-pressure systems or in circulation systems where the oil cooler is an important component for achieving long and secure functioning. For example, in hydraulic systems, engines, transmissions, transformers, fuel coolers, etc.
Technical specifications
- Maximum working pressure is 10 bar. Approved testing at a dynamic working pressure of 0-10 bar, 200,000 pulsation in load, 2 Hz.
- Corrosion protection: Nocolok brazing process and epoxy-coating.
- Connections: BSP |
|
Technical data :
Frequency : 50Hz
Voltage : 3x400V
Power : 1,1 kW
Inside dimensions : W 250mm, H 150mm, D 350mm
External dimensions (±10%) : W 505mm, H 1100mm, D 600mm
Equipment :
- Metallic construction.
- Fan integrated inside the casing.
- Top cover to direct the hot air towards the rear
- Nominal power of the fan : 1500 m3/h. |
|
SELF-CONTAINED COOLING UNITS:
The RAS cooling units were engineered and manufactured to substitute the former GAR and OCS series with an uncomplicated and compact product. The units are made up of an aluminium air-oil exchanger and a single electric motor which operates both the oil circulation gear pump and the cooling fan. |
|
| ... products without technical information |
| |
|
|