Applications
Type GUH industrial quality horizontal blower heater is designed to heat factories, warehouses, garages and other areas requiring forced air heating with no associated duct work.
Standard Features
Metal sheathed finned tubular heating elements encased in a 16 gauge steel cabinet with a powder coated finish. Unit includes a heavy gauge return air grille and adjustable louvered supply grill for comfort.
Options
Universal Wall and Ceiling Mounting Brackets provide flexible mounting arrangements - contact Gaumer.
|
|
Technical details
• Protection class: I
• Protection type: IP 20
• Mounting: Snap fastening
• Connection: Connecting cable 0.5 m 3 x 0.75 mm²
• Mounting position: vertical
• Fan function:
- permanently on operating voltage
- optional via separate supply line
• Blow-out temperature: ca. 60°C
• Enclosure temperature: ca. 70°C
• Temperature limitation: 71°C ± 7.5 K operating difference
• Fan service life: 50,000 hours
|
|
Technical details
• Protection class: I
• Protection type: IP 44
• Mounting: Screw fastening
• Connection:
GH2000: Connecting cable 2 m 3 x 1.5 mm²
GH4000: Terminal block 2.5 – 4 mm²
GH4000 (400V Version): Connecting cable 2 m 3 x 1.5 mm²
• Mounting position: horizontal
• Blower function:
- permanently on operating voltage
- optional via separate supply line
e.g. separate control of blower or other voltages
• Blow-out temperature: GH2000 ca. 100°C
GH4000 ca. 110°C
• Fan service life: 50,000 hours
|
|
Thalassa fan convector are reversible heating and air conditioning.
The offered range includes 4 models and 5 sizes, with powers from 5 kW cold production and 11 kW hot production.
Since there is poor residual pressure with this equipment (20 Pa), they are used preferably for direct blowing either hanging or wall mounted, with or without casing.
Easily integrated in any type of premises due to its discrete presentation and RAL 9010 epoxy painted frame.
Aircalo offers a wide scope of flow control customization.
|
|
|
|
|
|
Major 2
The Major 2 fan coil unit is designed to be mounted vertically on a wall or horizontally below ceilings to heat and cool homes, businesses and industrial and healthcare facilities. Not only does it combine the economic benefits of installing and operating a central boiler and chiller plant, it also allows individual temperature control in all rooms.
Available in six sizes and two models:
- CH: horizontal cased,
- CV: vertical cased.
Heating capacity: 2 to 20 kW
Cooling capacity: 0.6 to 8 kW
Air flow rates: 115 to 1300 m³/h
- Polymer casing with solid RAL 9010 finish,
- Two access doors lead to air bleed valve and control terminal,
- Water coil: two or four tubes or two tubes and electric heater,
- Condensate drain pan,
- Seven-speed motor (three factory-wired speeds) with balanced, double-inlet aluminium blower wheel,
- Mounting bracket frame,
- Regenerative polyester fibre filter. Efficiency class: G3 (EN 779),
- Fully enclosed electrical junction box,
- A wide selection of control options.
|
|
Floor Standing Type
This space-saving design with a slim shape and smart vent line offers the least obstruction to the surrounding area.
* The unit can be easily installed on the floor along the wall or under the window. Maintenance is simple.
* This type can be hung on the wall for easier cleaning.
|
|
Exhaust air system:
The exhaust air ceiling is a closed structure which complies with the hygienic requirements of VDI 2052, a regulation issued by the Association of German
Engineers, and BGR 111, a workplace health and safety regulation issued by German Trade Associations. The type of construction prevents the accumulation
of soot in the hollow space above the ceiling. The exhaust air chambers of the hoods can accommodate various types of fume extraction equipment with
grease separators. Their installation does not require
any tools.
|
|
Modulam AP - Autonomous stainless module for constitution of ceiling with laminar flow
Flow: 600 to 1250 m3/h.
3 sizes: 6-6, 9-6, and 12-6.
Final filtration (to be ordered in addition): H14 and U15.
2 versions of the ventilator: with alternative course (traditional motorization) or continuous (self-latching of the puffed up flow whatever the level of clogging of the filter).
Constitution of autonomous ceilings with laminar flows for obtaining cleanliness class ISO 5 (according to IN ISO 14644-1) in zones with environments controlled: phramaceutic, agroalimentary, plasturgie...
|
|
SAVANA is a new heating unit. It is offered in four various designs, which enable a wide spectrum of use. The design with a silver front cover with
V-lamellas or Jets is most suitable for supermarkets, stores and sports complexes. The industrial design without a front cover is recommended for production halls and other industrial premises.
SPECIFICATION:
- 4 types of design
- Air output up to 6900 m3/h
- High heater power up to 92 kW
- "V-TECHNOLOGY” and “JET System” for higher output and comfort
- Adjustable bracket for horizontal and vertical setting
- Easier installation for connecting water
|
|
Their flexibility and fast heating feature make it necessary to use the Armagnac in premises such as :
- Sales and/or storage areas
- Sports hall
- Agriculture and breeding premises
- Industrial and commercial buildings.
Over a pleasant presentation, electric aerothem Armagnac are fitted with all components and accessories allowing a quick installation, a safe and quiet operation.
- Armoured resistance
- Slow speed helicoid fan
- Power contactor
- Safety and control thermostats
- Fan timer
- On/off switch with light signal
- White RAL 9003 painted sheet steel frame, RAL 9010 lacquered deflectors protected with a removable plastic film.
Produced in 2 sizes, for power from 6 to 24 kW.
For powers from 15 kW to 24 kW only, the equipment is fitted with contactors allowing a two step operation if necessary.
|
|
|
|
|
|
Heater fans PHE and PHD
Robust, powerful and durable
For heating and ventilation of
Workplaces
Day rooms
Showrooms
Portacabins
Construction sites
or for drying of damp or moist rooms
Robust housing made of galvanised sheet-steel, coated, corrosion-resistant.
Carrying handle as tubular stand with sufficient floor clearance.
Heating elements made of stainless steel, non-glowing.
Thermal overload protection as standard feature. Switches motor off under thermal overload and comes on automatically again after cooling down.
With wall bracket
For portable or stationary operation.
High air circulation. Rapid heating.
5 power classes: from 3 to 20 kW.
Dual-walled housing offers safety.
Robust motor with ball bearings, maintenance-free
Fan and heater can be switched in 3 or 4 steps.
PHD 9/ 15/ 20 with timer: Switch-on time can be preselected up to 24 hours.
Heating thermostat with temperature range which can be set (infinitely variable) to between 0 °C - 40 °C. Fan continues to operate once the temperature has been reached.
|
|
This unit has function of electrical convector and fan. This allows :
- In the winter, very fast heating ( 2 stage of power : 2 - 3 KW). Homgeneity of the air temperature thanks to outlet direction.
- In the summer, ventilation only with very low electrical consumption (35W)
Compact, esthetic
Régulation on board
Wall mounting
|
|
DESCRIPTION:
Stove of industrial firewood with ventilator with operation to firewood, shavings, charcoal, etc.
Ideal for the heating of the industrial premises with a maximum volume of 1.075m3 to 2.150m3
FUEL:
LEÑA-BRIQUETAS-CARBÓN
|
|
Fan heaters of simple and robust design for heating recirculated air in areas such as workshops, factory shopfloors, warehouses, refectories, sports halls, garages, shops, greenhouse ...
Vulcanic manufactures a very large range of fan heaters, such as portable fan heaters, fan heaters with castors, and high power fan heaters for wall mounting.
|
|
|
Process Heat - nyb offers a complete range of fans for the process heat industry. Whatever your needs; high temp process fans, combustion air, exhaust, custom forced-draft or custom induced-draft, nyb has a design to accommodate.
|
|
| ... products without technical information |
| |
|
Plastics attract dust due to static electricity. The dust particles stick firmly to the surface, which makes it difficult to remove them. Due to their configuration, numerous plastic products have to be neutralised from a distance. For this purpose, SIMCO has developed ionising air blowers. The emitter points of the anti-static bar ionize the air which is blown towards the electrostatically charged object. The part is then neutralised by the ionized flow.
|
|
|
|
|
|
The Model 212v2 Benchtop Ioniser is a compact unit which complements the Meech Series 200 product range. The Model 212v2 provides excellent work station coverage and a high level of ESD protection. It has been specifically designed to meet the demanding performance requirements in applications such as: ·Semiconductor manufacture · Electronics assembly & testing · Test and re-work · Optics, contact lenses & fibre optics · Medical device manufacture & packaging · Wave soldering
Features
Removable pins Easy to clean and replace. Minimum maintenance downtime.
Balance ionisation (typical) +/- 10V Prevents possible ESD damage in sensitive electronic applications, reduces scrap and saves on replacement costs.
Two fan speed settings Can be set for optimum operator comfort and ionisation range.
Dirty pin indicator and audible alarm Particularly important in applications where balanced ionisation is key to prevention of ESD damage to components. Also, informs the operator when maintenance is required (emitter pin cleaning).
Small footprint Takes up little room, allowing more space for operators' work activity.
|
|
|
|
|
|
The Model 935 Ionising Blower provides effective long range ionisation over a large area. Its versatility makes it suitable for a wide range of industrial applications. The Model 935 comprises an ionisation head and an integrated fan system. A high volume flow of ionised air is generated by blowing air through the ionisation head at the mouth of the unit. Ionisation is provided by powerful 915 bars, generating an ionised field to a depth of up to 2000mm. The 935 unit is powered by the Model 904 (see separate datasheet) and is available in both 110V and 240V versions. Patent No. ZL200530000279.5
Features
Variable fan speed (option) Air flow can be adjusted to suit specific applications
Easy, flexible mounting Can be mounted on walls, benches, ceilings etc to suit a specific application
Large footprint Effective over a large target area
Ionisation provided by 915 bars Powerful ionisation with very fast decay times
Filter media (option) Ensures only clean air impacts the target area
Removable polypropylene grille Easy access for regular maintenance of ionisation head
Available in 200mm length increments Flexibility to optimise performance for individual applications
High volume air flow Provides highly effective long range ionisation
Resistively coupled ionisation head Shockless operation
|
|
|
|
|
|
Single Anti Static Blower
H&O Single Ionising Air Blower is designed for the neutralization of the static charges which cause some serious problems. High technology used in design can produce more efficient results for static electric problems even in high-speed applications. It provides high performance and efficient ionization with fast discharging time. Blower seperates air molecules to the positive and negative ions by the electric field it generates and transports them.
Any static charged product passed from the efficient distance of the Air Blower will draw the opposite charged ions and neutralize the product. This will prevent the sticking of products to other products or parts of machines.At the same time electrical shocks, explosions, fire danger and dust attraction of which is caused by static electric will be prevented.
Thanks to Air Blower which doesn't need any calibrations and can be cleaned and cared easily. Machines will perform hygienic, safe and high quality production with high performance without problems. There is one fan in Air Blower for increasing ionization distance and supplying enough air flow. System can be mounted to places which are hard to reach by the connection apparatus that is provided on the system. Blower filters should be cleaned occasionally.
|
|
|
Where air is required to affect static removal at a distance and compressed air is not available, the Ion Blower can be used with either the standard Model RN static bar or the extra powerful Model VS bar.
|
|
|
|
|
|
Dual Anti Static Blowers
H&O Single Ionising Air Blower is designed for the neutralization of the static charges which cause some serious problems. High technology used in design can produce more efficient results for static electric problems even in high-speed applications. It provides high performance and efficient ionization with fast discharging time. Blower seperates air molecules to the positive and negative ions by the electric field it generates and transports them.
Any static charged product passed from the efficient distance of the Air Blower will draw the opposite charged ions and neutralize the product. This will prevent the sticking of products to other products or parts of machines.At the same time electrical shocks, explosions, fire danger and dust attraction of which is caused by static electric will be prevented.
Thanks to Air Blower which doesn't need any calibrations and can be cleaned and cared easily. Machines will perform hygienic, safe and high quality production with high performance without problems. There is one fan in Air Blower for increasing ionization distance and supplying enough air flow. System can be mounted to places which are hard to reach by the connection apparatus that is provided on the system. Blower filters should be cleaned occasionally.
|
|
EXAIR static eliminators neutralize static electricity charges in a wide variety of industrial processes. Anti-static products eliminate static cling that causes dust attraction, jams and tearing. Materials such as paper, plastic and textiles normally contain an equal number of positive and negative charges - that is, they are electrically charged. This static charge causes the following problems:
* Dust clinging to product
* Product clinging to itself, rollers, machine beds or frames
* Materials tearing, jamming or curling
* Sheet feeding problems
* Hazardous sparks or shocks
|
|
|
Ionizing Air Blowers consist a static device and power source inside of housings of various shapes to create bi-polar ions. The blower acts as an extended range ionzier to move the ionization forward to charged surfaces and materials. Ionizing air blowers are ideal for solving static on plastic molded parts and webs.
|
|
Ionized air blower for static neutralization
ELCOWA's ECOBLOWER 350-C has been designed to efficiently remove static charges from a distance. It is built in a robust painted steel cabinet enclosing the high voltage power supply, tangential fan, and a blowing nozzle in which three shockless ionizating bars. The pivoting mounting bracket makes it easy to install and adjust. The ionization blower ECOBLOWER 350-C is a compact, self-contained unit ready for service. As the high voltage power supply is incorporated into the blower, there is no high voltage cable nor remote power supply, reducing electrical hazards.
|
|
The Meech Model 955 is a hand held ionising blow gun for removing static charges and dust in a range of industrial applications. The portable Model 955 has been designed to provide efficiency in both cost and performance. An electrical centrifugal fan provides high velocity air flow, avoiding the need for a costly compressed air supply. Ionisation is provided by titanium emitters located in the nozzle of the gun, powered by a high voltage DC source. The 955 requires just a standard single phase 240V supply, thereby making the unit fully portable.
Features
Small and compact. Easy to locate and install in confined spaces.
Only maintenance requirement is periodic cleaning around emitter pin. Easy maintenance and minimum downtime.
Flexible knuckle trunking extension Delivers ionisation precisely where it is needed. Effective in "difficult to reach" places.
"Stay put" knuckle trunking. Enables simple and quick installastion.
Rapid decay times Highly effective in sheer feeder applications.
|
|
|
|