|
|
This unit has function of electrical convector and fan. This allows :
- In the winter, very fast heating ( 2 stage of power : 2 - 3 KW). Homgeneity of the air temperature thanks to outlet direction.
- In the summer, ventilation only with very low electrical consumption (35W)
Compact, esthetic
Régulation on board
Wall mounting
|
|
Thalassa fan convector are reversible heating and air conditioning.
The offered range includes 4 models and 5 sizes, with powers from 5 kW cold production and 11 kW hot production.
Since there is poor residual pressure with this equipment (20 Pa), they are used preferably for direct blowing either hanging or wall mounted, with or without casing.
Easily integrated in any type of premises due to its discrete presentation and RAL 9010 epoxy painted frame.
Aircalo offers a wide scope of flow control customization.
|
|
|
|
|
|
Major 2
The Major 2 fan coil unit is designed to be mounted vertically on a wall or horizontally below ceilings to heat and cool homes, businesses and industrial and healthcare facilities. Not only does it combine the economic benefits of installing and operating a central boiler and chiller plant, it also allows individual temperature control in all rooms.
Available in six sizes and two models:
- CH: horizontal cased,
- CV: vertical cased.
Heating capacity: 2 to 20 kW
Cooling capacity: 0.6 to 8 kW
Air flow rates: 115 to 1300 m³/h
- Polymer casing with solid RAL 9010 finish,
- Two access doors lead to air bleed valve and control terminal,
- Water coil: two or four tubes or two tubes and electric heater,
- Condensate drain pan,
- Seven-speed motor (three factory-wired speeds) with balanced, double-inlet aluminium blower wheel,
- Mounting bracket frame,
- Regenerative polyester fibre filter. Efficiency class: G3 (EN 779),
- Fully enclosed electrical junction box,
- A wide selection of control options.
|
|
Floor Standing Type
This space-saving design with a slim shape and smart vent line offers the least obstruction to the surrounding area.
* The unit can be easily installed on the floor along the wall or under the window. Maintenance is simple.
* This type can be hung on the wall for easier cleaning.
|
|
SAVANA is a new heating unit. It is offered in four various designs, which enable a wide spectrum of use. The design with a silver front cover with
V-lamellas or Jets is most suitable for supermarkets, stores and sports complexes. The industrial design without a front cover is recommended for production halls and other industrial premises.
SPECIFICATION:
- 4 types of design
- Air output up to 6900 m3/h
- High heater power up to 92 kW
- "V-TECHNOLOGY” and “JET System” for higher output and comfort
- Adjustable bracket for horizontal and vertical setting
- Easier installation for connecting water
|
|
Their flexibility and fast heating feature make it necessary to use the Armagnac in premises such as :
- Sales and/or storage areas
- Sports hall
- Agriculture and breeding premises
- Industrial and commercial buildings.
Over a pleasant presentation, electric aerothem Armagnac are fitted with all components and accessories allowing a quick installation, a safe and quiet operation.
- Armoured resistance
- Slow speed helicoid fan
- Power contactor
- Safety and control thermostats
- Fan timer
- On/off switch with light signal
- White RAL 9003 painted sheet steel frame, RAL 9010 lacquered deflectors protected with a removable plastic film.
Produced in 2 sizes, for power from 6 to 24 kW.
For powers from 15 kW to 24 kW only, the equipment is fitted with contactors allowing a two step operation if necessary.
|
|
|
|
|
|
Heater fans PHE and PHD
Robust, powerful and durable
For heating and ventilation of
Workplaces
Day rooms
Showrooms
Portacabins
Construction sites
or for drying of damp or moist rooms
Robust housing made of galvanised sheet-steel, coated, corrosion-resistant.
Carrying handle as tubular stand with sufficient floor clearance.
Heating elements made of stainless steel, non-glowing.
Thermal overload protection as standard feature. Switches motor off under thermal overload and comes on automatically again after cooling down.
With wall bracket
For portable or stationary operation.
High air circulation. Rapid heating.
5 power classes: from 3 to 20 kW.
Dual-walled housing offers safety.
Robust motor with ball bearings, maintenance-free
Fan and heater can be switched in 3 or 4 steps.
PHD 9/ 15/ 20 with timer: Switch-on time can be preselected up to 24 hours.
Heating thermostat with temperature range which can be set (infinitely variable) to between 0 °C - 40 °C. Fan continues to operate once the temperature has been reached.
|
|
DESCRIPTION:
Stove of industrial firewood with ventilator with operation to firewood, shavings, charcoal, etc.
Ideal for the heating of the industrial premises with a maximum volume of 1.075m3 to 2.150m3
FUEL:
LEÑA-BRIQUETAS-CARBÓN
|
|
Fan heaters of simple and robust design for heating recirculated air in areas such as workshops, factory shopfloors, warehouses, refectories, sports halls, garages, shops, greenhouse ...
Vulcanic manufactures a very large range of fan heaters, such as portable fan heaters, fan heaters with castors, and high power fan heaters for wall mounting.
|
|
Applications
Type GUH industrial quality horizontal blower heater is designed to heat factories, warehouses, garages and other areas requiring forced air heating with no associated duct work.
Standard Features
Metal sheathed finned tubular heating elements encased in a 16 gauge steel cabinet with a powder coated finish. Unit includes a heavy gauge return air grille and adjustable louvered supply grill for comfort.
Options
Universal Wall and Ceiling Mounting Brackets provide flexible mounting arrangements - contact Gaumer.
|
|
Technical details
• Protection class: I
• Protection type: IP 20
• Mounting: Snap fastening
• Connection: Connecting cable 0.5 m 3 x 0.75 mm²
• Mounting position: vertical
• Fan function:
- permanently on operating voltage
- optional via separate supply line
• Blow-out temperature: ca. 60°C
• Enclosure temperature: ca. 70°C
• Temperature limitation: 71°C ± 7.5 K operating difference
• Fan service life: 50,000 hours
|
|
Technical details
• Protection class: I
• Protection type: IP 44
• Mounting: Screw fastening
• Connection:
GH2000: Connecting cable 2 m 3 x 1.5 mm²
GH4000: Terminal block 2.5 – 4 mm²
GH4000 (400V Version): Connecting cable 2 m 3 x 1.5 mm²
• Mounting position: horizontal
• Blower function:
- permanently on operating voltage
- optional via separate supply line
e.g. separate control of blower or other voltages
• Blow-out temperature: GH2000 ca. 100°C
GH4000 ca. 110°C
• Fan service life: 50,000 hours
|
|
Exhaust air system:
The exhaust air ceiling is a closed structure which complies with the hygienic requirements of VDI 2052, a regulation issued by the Association of German
Engineers, and BGR 111, a workplace health and safety regulation issued by German Trade Associations. The type of construction prevents the accumulation
of soot in the hollow space above the ceiling. The exhaust air chambers of the hoods can accommodate various types of fume extraction equipment with
grease separators. Their installation does not require
any tools.
|
|
Modulam AP - Autonomous stainless module for constitution of ceiling with laminar flow
Flow: 600 to 1250 m3/h.
3 sizes: 6-6, 9-6, and 12-6.
Final filtration (to be ordered in addition): H14 and U15.
2 versions of the ventilator: with alternative course (traditional motorization) or continuous (self-latching of the puffed up flow whatever the level of clogging of the filter).
Constitution of autonomous ceilings with laminar flows for obtaining cleanliness class ISO 5 (according to IN ISO 14644-1) in zones with environments controlled: phramaceutic, agroalimentary, plasturgie...
|
|
|
Process Heat - nyb offers a complete range of fans for the process heat industry. Whatever your needs; high temp process fans, combustion air, exhaust, custom forced-draft or custom induced-draft, nyb has a design to accommodate.
|
|
| ... products without technical information |
| |
CV MANN 400ºC
MMVC 20/20 - MMVC 30/28
DESCRIPTION:
Smoke emergency fans 400ºC/2h according to EN 12101-3:2002 European standard.
Airflow: 13.000 - 54.000 m3/h
APPLICATIONS:
- Industrial use.
- Industrial and professional cooking.
- Smoke emergency exhaust.
|
|
Centrifugal fan VDVB 600°C/120min.
Multiple garage fan unit, smoke exhaust design, direct drive, for roof installation.
Sizes:
VDVB 355 - VDVB 1.250 (Ømm)
Application:
Smoke exhaustion at 700°C/120min
Technical Data:
V = 500 - 90.000 m³/h
P = 200 - 2.800 Pa
L = 0,25 - 55 kW
|
|
|
The SERIE ET roof centrifugal fans are especially suited to applications where it is necessary to suck clean air or fumes at temperatures up to 70°C. The base is produced in steel. The fan dome is produced in plastic reinforced by fiber glass.
|
|
Smoke Extract Roof Fans F400 (400°C / 120 min.)
vertikal outlet
operation of tested smoke extraction motor (EN 12101-3)
Diameter of impeller: 355-710mm
max. V= 28.100 m³/h
max. pt= 1.650 Pa
smoke and heat extraction unit (double function)
many accessories
Application:
main air extraction for residences, offices and industry
|
|
| ... products without technical information |
| |
|
|