Heaters
Compact heaters to keeping at a moderate temperature of cabinets and housings with electrical electronic installations.
In switchgear cabinets condensation with variations in temperature, which can lead to malfunctions or to losses of the components in the switchgear cabinet, forms. Heaters prevent subnormal temperatures and work against the emergence of condensation. Heater blowers provide additionally for the even distribution of warm interior air. The heaters are appropriate for continuous operation.
|
|
Heaters for the thermo-regulation of enclosures, for application on DIN rail, and available in three version:
- with bipolar (15-30W) or three-pole (45-150W) power cable
- with three-pole terminal block (45-150W)
- ventilated (250-400W)
|
|
|
Condensation poses a particular risk for control electronics, especially with outdoor siting, but also indoors. Various different output categories ensure that the correct thermal output is always available. In this way, the total required thermal output can be distributed with complete accuracy within an enclosure.
|
|
-Pressure clamp connectors
-Dynamic heating up
-Wide voltage range
-Temperature limiting
-Energy saving
-Clip fixing
-Quick installation
These heaters are used in enclosures where damage from condensation must be prevented, or where the temperature may not fall below a minimum value.
The aluminium profile heater body design has a chimney effect and distributes the heat evenly.
The pressure clamp connectors save time and simplify installation.
|
|
Low surface temperature
Quick mounting due to clip fixing
Double insulated (plastic)
Wide voltage range
Small size
Compact heater for the use in enclosures with electrical/electronical components. The design of the heater supports the natural convection which results in a high air-current of warm air.
The surface temperatures on the accessible side surfaces of the housing are kept down as a result of the heater design.
Our complete range of thermostats and hygrostats can directly be connected to the heater CS 060.
This heater is also available in a version with plug-in thermostat requiring no additional wiring (CSF 060).
Both versions are designed for permanent operation.
|
|
Units for DIN or screw mounting.
TH heaters, installed separately from cooling unit, must be connected to a TMC thermostat. When used to prevent cabinet condensate they should be electrically connected also when cabinet is off.In this cabinet it’s better to install more heating elements with small heating power.In this way there is an optimal air temperature distribution.
|
|
Technical details
- Protection class I (ground wire) - protection type IP 54 (DK = IP 20)
- Temperature setting:
ON 25 °C - OFF 55 °C (operating temperature of heating
system itself)*
Tropical version possible: ON 35 °C - OFF 65 °C
-> Other settings upon request
- 2 Connecting alternatives (optional)
Connecting leads (AL) 0.5 m, 3 x 0.75 mm² PVC
- > Other lengths upon request
Lead out terminal (DK) 0.08 - 2.5 mm²
- Mounting position: vertical
- 2 fastening alternatives (optional)
Snap fitting for 35 mm DIN rail (figure 1)*
Screw fastening (figure 2)
|
|
PTC units for DIN bar application.
EH/FH heaters, installed separately from cooling unit, must be connected to TMC thermostat. When used to prevent cabinet condensate they should be eletrically connected also when cabinet is off.In this cabinet it’s better to install more heating elements with small heating power.In this way there is an optimal air temperature distribution.
|
|
Technical details
• Protection class II (double insulated)
- protection type IP 54 (DK = IP 20)
• Temperature behavior:
· Self control, in variation of ambient temperature
· Dynamic heating-up
• Auxiliary fan attachable for improved air distribution
–> Auxiliary fan
• 2 Connecting alternatives (optional)
Connecting leads (AL) 0.5 m, 2 x 0.75 mm² Silikon
–> Other lengths upon request
Lead out terminal (DK) 0.08 - 2.5 mm²
• Mounting position: vertical
• 3 Fastening alternatives (optional)
|
|
Technical Details
• Protection class I (ground wire) - protection type IP 65
• Temperature setting:
ON 25 °C - OFF 55 °C (operating temperature of
heating system itself)
Tropical version possible: ON 35 °C - OFF 65 °C
–> Other settings upon request
• Connection
Connecting leads (AL) 0.5 m, 3 x 0.75 mm² PVC
–> Other lengths upon request
• Mounting position: vertical
• Fastening
|
|
-Slim casing
-Electronic ballast
-Lamp without/with electrical socket (choice of sockets)
-Magnet fixing (option)
-Energy saving lamp
-Automatic switching
The flat slimline lamp SL 025 with movement sensor is suitable for all types of panels and enclosures, especially where space is at a premium.
The lamp can be mounted on its narrow or broad surface using screws. It is also available with a magnet which allows it to be fitted quickly in any position in a steel enclosure.
Both versions are available with an integrated electrical socket enabling the use of additional appliances.
Approvals: UL File Nr. E 234324
|
|
Product group P3
Pivoting frame for directed ventilation
Electric data:
• Protection class I (ground wire)
• Protection type IP 20
• Connecting leads 0,5m 3x0,75 mm² PVC
Other lengths upon request
Utilizing a circulation fan avoids head accumulation and formation of heat pockets inside control cabinets. When heaters are installed, their efficiency is increased by circulation fans. The resulting air circulation dissipates heat through the surface of the cabinet and so, a cooling effect is achieved.
|
|
... see all the products in the category
Axial fans
|
RKVM-1708
17" TFT LCD 1U Rackmount KVM Switch 8 Ports
Features:
17" TFT LCD 1280 x 1024
Built-in A/D Board
Support 8 Ports KVM Switch
Membrane keyboard in 104 keys, with touch pad
Auto scan mode for monitoring PCs
Built-in rail self-locking device
RoHS ComplianceR=
|
|
Feature :
- 17” TFT LCD 1280 x 1024
- Built-in A/D Board
- Built-in OSD Button
- Support D-SUB and DVI-I Input
- The depth of chassis would be 515mm
- RoHS ComplianceT
|
|
Elo's iTouch touch-on-tube chassis CRTs are the right choice for your kiosk because they are durable, reliable, sealed, and deliver the ultimate in picture quality.
Typical desktop monitor designs can change without notice every 12 to 18 months, creating havoc for the design and service of kiosks and other enclosed applications. Elo's kiosk CRTs reduce or eliminate the need for redesign by providing a much longer model life than plastic case CRTs. At the same time, they provide the reliability and ruggedness required for operation in a public environment.
Featuring Elo's breakthrough iTouch touch-on-tube technology and no overlay to break, your kiosk will have the best picture quality and vandal resistance possible on a touch CRT. A final benefit is the watertight sealed bezel that adapts the curvature of the CRT face to a flat cabinet front.
|
|
Elo's chassis LCD monitors have a long-lasting product cycle because the enclosure is controlled by Elo's specifications. Future panel improvements are therefore possible without external changes. The monitors are available with multiple touch technologies and all feature a unique, injection-molded minibezel and watertight seal, plus a multitude of mounting options.
Features include:
·Analog and digital (DVI-D) video inputs
·Long lasting product cycle—enclosure controlled by Elo specifications
·Panel upgrades possible to the model in the future without external changes
·Integrated precision minibezel with watertight 0.5 mm seal
·Multiple mounting options including rear-mount, VESA mount, and front/panel-mount bezels or 19" rack-mount bezel
·Serial or USB touch interface
·Multilingual remote on-screen display (OSD)
·Worldwide agency approvals
·3-D electronic design files available
|
|
RKVM-1708
17" TFT LCD 1U Rackmount KVM Switch 8 Ports
Features:
17" TFT LCD 1280 x 1024
Built-in A/D Board
Support 8 Ports KVM Switch
Membrane keyboard in 104 keys, with touch pad
Auto scan mode for monitoring PCs
Built-in rail self-locking device
RoHS ComplianceR=
|
|
- 15" TFT LCD 1024 x 768
- Built-in A/D Board
- Membrane keyboard in 104 Keys, with touch pad
- Built-in rail self-locking device
- 1 Port
- Dimensions 484(W) x 44(H) x 470(D)
|
|
|
|
|
|
The Winchester Rack and Panel product line is one of the most comprehensive pin and socket style connector systems available for cable-to-cable, cable-to-panel, and cable-to-board applications. The extreme versatility of Winchester's Rack and Panel line allows this connector system to be used in a wide variety of industries including industrial, military, aerospace, instrumentation, and telecommunications.
The Rack and Panel product line consists of molded insulators, screw-machined contacts, anodized aluminum hoods and protective shells, and a wide assortment of mating hardware. Other important features of the Rack and Panel product line include:
- Insulators available in a wide range of position sizes depending upon the product series.
- Solder cup, crimp, and dip solder PCB contacts available in pin diameters of .062, .040, .030, and .025 inches with current ratings of 13, 7.5, 5 and 3 Amps.
- Contacts pre-loaded into insulators or sold separately.
- Top or side opening cable hoods for applications requiring 180- or 90-degree cable exit.
- Male plug and female receptacle protective shells help to protect connector interfaces during handling as well as to provide polarization to ensure connectors are mated correctly.
- Wide assortment of mating hardware and accessories including fixed and turnable jackscrews and sockets, guide pins and sockets, mounting plates, and gaskets.
|
|
| ... products without technical information |
| |
| ... products without technical information |
| |
630 A to 3200 A moulded case circuit-breakers
Description
Nominal current from 630 to 3200 A
2 breaking capacities:200kA at 440V - 75kA at 690V for 630 and 800A LB frames
4 breaking performances from 50 to 150 kA at 415 V
Voltage rating:up to 690 V
2 physical sizes from 630 to 3200 A
A single pole pitch of 70 mm
3 and 4-pole versions
solation with positive break indication
4 Micrologic control units enriched by measurement, energy management and network analysis functions
Earth leakage protection built into electronic protection Wide range of common auxiliaries and accessories interchangeable on site
Compliance with international standards IEC 60947-1 and 2, IEC 68230 for type 2 tropicalisation
Compliance with specifications of marine classification companies:Bureau Veritas, Lloyd’s Register of Shipping, Det Norske Veritas, etc.
|
|
|
|
|
|
The majority of distribution systems are designed to an ultimate circuit rating (lcu). An lcu rated MCCB provides the optimum protection in terms of safe and economical selection.
Certain applications may require protection wich is designed to the more onerous service short circuit rating (lcu).
Terasaki's TemBreak Plus range can provide a wide choice of MCCBs with superior lcs ratings up to 85kA at 440V AC.
lcu=o-co 2 full short circuits
lcs=o-co-co 3 full short circuit
All TemBreak Plugin and drawout MCCBs are fitted with a safety trip as standard. If an attempt is made to remove an MCCB while ON it will automatically trip.
The neutral pole of all TemBreak MCCBs are of early make / late break design. This eliminates the risk of abnormal line to neutral voltages which may damage sensitive electronic equipment.
TemBreak MCCBs from 125AF to 1600AF are suitable for isolation as defined by IEC 947-2. Positive Contact Indication (PCI) is achieved via the toggle mechanism. Padlocks can only be installed if the contacts are fully open or closed.
|
|
|
|
|
|
The TemBreak series offers the models of the 800A to 1600A frames with the breaking capacity up to 125 kA, and this series consists of thermal adjustable type and electronic type that allows you to select the most suitable breaker for your system
Features of the TemBreak Electronic Moulded Case Circuit Breaker:
- Long time delay trip, short time delay trip, and instantaneous trip are available as standard.
- All of long time delay trip, short time delay trip, pretrip alarm, and ground fault trip can be adjusted. The rated current can be adjusted in a range between 50% and 100%. For short time delay trip, ramp characteristics can be selected with the switch to enable selective coordination with lower breakers and fuses.
- The multi-protective device uses the r.m.s. value control. It samples peak current every 0.5msec. to calculate a root-mean-square value. Therefore, harmonics up to 19 th harmonic are accurately detected at 50 Hz to prevent any malfunction from occurring due to harmonics.
|
|
RCCB Record Plus: FD63/160 frame size
Rated at 160A, the FD63/160 frame size is designed for use in both a DIN-rail environment with modular equipment and in industrial applications. It is supplied with IPXXB terminals suitable for direct connection of one or two conductors totalling up to 95 mm² and is available as a thermal-magnetic breaker, a moulded case switch, and as a magnetic-only motor circuit protector.
The FD63/160 bridges the gap between residential miniature circuit breakers and industrial moulded case circuit breakers.
In compliance with EN 60947, BS, VDE, UTE, KEMA, CEI
3 and 4 pole versions available
FD63 to 63A and FD160 to 160A
Full range of add-on accessories, including:
thermal magnetic/magnetic trip units
auxiliary contacts
completely integrated add-on devices available
rotary handles
electrical operators
connectivity - 60 mm system
|
|
DC braking with one-way rectification
suitable for all asynchronous motors and for mono phase motors
controlled by microcontroller
easy mounting, also for retrofitting into existing plants
wear-resistant and maintenance-free
integrated braking contactor
printed circuit-board version with fault signalling contact
for snap-on mounting onto 35mm DIN rail
degree of protection: case version IP 20, printed circuit-board version (LP) IP 00
meets trade assoc. requirements for category 2 acc. to EN 954-1 according to the test principles of woodworking machines GS-HO-01 and is already certified
|
|
|
|
|
|
CitectFacilities integrates all your facilities systems, including HVAC, lighting, fire, CCTV and access control, across your entire enterprise to deliver a single facilities monitoring and control solution. The software can connect to hardware devices supplied from multiple vendors, in single or multiple sites.
What does this mean for you?
A single, central view of all facilities systems is essential for property owners and facilities managers:
PROPERTY OWNERS
CitectFacilities provides strategic information that lets property owners reduce facility operating costs and improve tenant service. Existing and future facilities equipment investments are protected and the high scalability provides a low risk, low entry cost option that lets you expand your facilities application according to your business plan.
FACILITY MANAGERS
Facility Managers gain real-time visibility of all facilities systems, including central alarm management, with CitectFacilities. This raises staff productivity and improves responsiveness to tenants. Open protocols and open architecture gives you the flexibility to integrate building automation technology suited to your facility.
|
|
|
|