DE-FROSTING CB HEATING CORD
Application :
. Heat pump evaporator defrosting.
Technical data :
. Standard power : 30 W/m
. Standard voltage : 230 V
. Regulation :
preset +5°C thermostat included
. Standard lengths (1m multiples) :
from 1 to 6m
Advantage :
. Heating and regulation functions combined in a sole component.
Option :
. Tinned copper braid (with earth lead).
|
|
|
RMB self-thermostated heating tape is a ready to use heating tape ; you do not need any tool to lay it and you save 40% laying time in comparison with other heating tapes.
|
|
Industrial heating tape
Applications :
. heating and temperature maintenance of pipes, valves, tanks, etc ...
. unclogging of hoppers.
. freeze protection of huge equipments.
. laboratories.
advantages :
. heating tape ready to install.
. high flexibility for elaborate shapes.
. good resistance to humidity.
technical data :
. standard linear output : 150W/m
. standard voltage : 230V-50/60 Hz
. other voltage : on request
. standard lengths : 2m, 7m and 12m
. supply cable : H07RNF L2m
. max. exposure temperature : 180°C
. max. maintenance temperature : 150°C
|
|
HEATING WIRE IC RANGE - for cold room doors and refrigerated showcases
Applications :
. Framing of cold room doors and negative cabinets
. Doorstep of cold room
. Demisting of refrigerated showcases
advantages :
. No over-thickness at junctions heating part/cold leads
. Heating part and cold leads are mechanically and electrically shielded
caractéristiques techniques :
. Maximum maintening temperature (power ON) : 140 °C
. Maximum exposure temperature (power OFF) : 180 °C
. Standard power : 30W/m
. Standard voltage : 230 V
. Standard lengths (multiple of 0.5 m) : from 1 to 8 m
. Tinned-copper braid from one end to the other end
|
|
Self-limiting tape is available in 2 different outputs: 15 W/m and 20W/m:
• RAG15 self-limiting heating tape (15W/m at +10°C) is delivered in 100m drums to be cut and connected on site ; main use is to prevent frost from pipes. It is water and sun resistant ; aluminiupm tape and earth lead make electrical screening.
• RAG20 self-limiting heating tape (20W/m at +10°C) is delivered in 100m drums to be cut and connected on site ; main use is to prevent frost from pipes or tanks; it can be used also to prevent snow from roofs and gutters. It is water and sun resistant ; aluminiupm tape and earth lead make electrical screening.
|
|
The versatile Watlow cable heater can be formed into a variety of shapes as dictated by its many applications. These small diameter, high performance units are fully annealed and readily bent to your desired configuration.
Applications
Plastic injection molding nozzles
Semiconductor manufacturing and wafer processing
Hot metal forming dies and punches
Sealing and cutting bars
Restaurant and food processing equipment
Cast-in heaters
Laminating and printing presses
Air heating
Heating in a vacuum environment
Textile manufacturing
|
|
Characteristics: A complete range of heating cables, heater strips, woven resistors, drain cables, heat-trace cables, and cables for underfloor heating.
Applications: Refrigeration (reach-in refrigerators, refrigerating compressors, cold rooms, refrigerated units), construction (floors, gutters, roads), industry (petrochemicals, agrifood, aerospace), rail transport (points, trains, metro systems), other (wind farms, aquariums).
Brands: FLEXCORD, FLEXUNIT, FLEXDRAIN, FLEXTAPE, STPGEL, ANTIFREEZE, FLEXFLOOR, FLEXBELT, FLEXMAT, FLEXPLATE, FLEXDRUM, FLEXKIT
|
|
|
Parallel heating cable constant power, is the best solution for all these situations where special electric heating system is needed: electric floor heating, electric radiant floor for ramps, electric trace heating for pipes, electric trace heating for storage tanks, snow melting systems for ramps, access, roads, systems, snow melting systems for roofs, terraces, gutters, pipes, etc., electric heating for animals: pigs, pets, exotic animals habitats, electric heating for agriculture: small greenhouses, terraces, seedbeds, etc.
|
|
Heating wires made of PVC , Silicon , PTFE , fiber glass, fitted with tube and aluminium sheet supportse . For application maximum 450°C available in sigle and double insulation.
Available in in bobbins or cut . On request all products are supply with faston .
|
|
|
|
|
|
In ECAS we manufacture heating cables, parallel or serial, applicable to all those situations where heating is needed.
Model CTCS, parallel heating cable constant power, allows to be cut on site.
Characteristic
Current: 125V, 230V, 380V
Power: 10-50 W/m
Conductor surface: 2 x 0.75 mm², 2 x 1.5 mm² y *2 x 2.5 mm² (*Unique on the Spanish Market)
Insulation between conductors: Silicone
Outer covering insulation: Silicon, P.V.C, metal screening, etc.
Supply
.In reels from 100 to 500 metres
.In sections with lengths adapted to any project, ready to be installed.
Model RFS and RFSS, electric flexible serial resistance
Characteristic
Operating voltages: 12v, 24v, 48v, 110v, 125v, 230v, 380v... 750v.
Power output at 230 V: 8 to 60w/m
Maximum operating temperature: 180ºC
Maximum circuit length: According to model
Heating conductor: Ni/Cr 80/20
Core : Woven glass fibre
Type of insulation: Thermal Silicone, Glass fibre, P.V.C, etc.
Supply
.In reels.
.In groups already finishes, according to longitudes.
.With diameter of the Isolation: 2,9mm, 4mm (normalized), 5mm, 6mm.
Applications
Electric radiant floor, snow melting systems for ramps, roofs and gutters, trace heating for pipes and storage tanks, drum heaters, etc.
|
|
Applications:
Radiation heaters, vacuum technology, submersible heaters, containers, valves, pumps, forms, process and plate heaters.
|
|
|
|
|
|
At ECAS, we manufacture heating cables and flexible electric elements, for temperature control systems in networks of pipes.
The main purpose of pipe tracing is to avoid and compensate for the loss of heat certain fluids undergo during particular production processes.
Of utmost importance is that the fluid or product flowing in the pipes does not freeze, change viscosity, or harm the piping network.
For sanitary hot water systems, our pipe tracing system avoids the cooling of the water, especially when it is not moving, avoiding the spread of Legionnaire disease.
Heating cable:
For pipe tracing projects we recommend constant power parallel heating cable, model CTCS.
The parallel heating cable has a constant lineal wattage even when it is cut to required length.
Control and regulating :
We have different types of control and temperature regulating solutions, which are adaptable to all kinds of projects, and/or the needs of our customers.
Below are some of the control systems:
DPA: Control and regulation box to connect between 1 and 4 circuits, from 8A to 63A at 230V.
EWDR 902 - T: Digital Thermometer/Thermostat.
ETV - 1991- P: DIN/Omega rail electronic modular analogue thermostat.
ETN - 2P - 1441: DIN/Omega rail electronic modular analogue thermostat with mini-switchboard.
|
|
Application Pontencial:
Submersible heaters, containers, valves, pumps, form, process and plate heaters.
This mineral-insulated heating cable with a braiding of high grade stell 14541 is applicable within extreme corrosive and damp surroundings. The HIL heating cable is extremely robust and easy to bend. The stainless stell brainding is waterlight, oiltight and gastight. An utilisation temperature of up to 800°C enables a variety of applications. The cold end of the heating cable can be fed into a terminal box and connected by means of a MX20X1.5 screwed connection.
|
|
HEATING CABLES - HC3/EX-HC3 - for industries and hazardous areas.
Thermo Heating Cable HC3 are the hardy and tough heating cable. When the ambient runs low, strap our workhorse heating cable and keep the fluid flow.
Heating Cable HC3 maintains temperatures in pipelines and storage tanks to keep fluids in flow state. They are the ideal for process heating requirements in Oil & Gas, Petrochemical, Power, Chemicals & Fertilizers, Metallurgical, Cement, Pharma, Food and Edible oil industries.
Construction
Heating Cable HC3 is a series type heating cable with single conductor (multistrand, spiraled) heating element with a primary PTFE (Teflon) insulation, metal braid and an outer PTFE sheath. Each length of heating cable HC3 requires termination kits with cold lead for power connection.
|
|
CH-Constant Watt High Temperature Maintenance Electric Trace Bundles
Maintain Temperatures up to 400˚F (204˚C)
Process Tubes 1/4” to 1/2” O.D. (6mm to 12mm) - Single or Dual Tube Designs
Applications:
Analyzer, impulse and instrument lines; small diameter process lines, stack gas sampling lines; and utility lines.
|
|
| ... products without technical information |
| |
|
|