|
|
exhaust gas hoses for temperatures up to + 1.100 °C (when exhaust gas funnels are used properly and fresh air is feed enough), DN 16 - DN 500.
Applications:
Extraction of engine exhaust gases, for all usual suction extraxtion systems such as hose reel, slotted channels, abovefloor and underfloor extraction, stationary suction plants, flue gas exhaust, vehicle construction, engine construction, aircraft industries, defence industries, general engineering, hot air, low pressure applications, furnace construction, iron- and steel works, infrared dryer plants, radiant heat protection ...
Properties:
extremely flexible, small bend radius, very lightweight,
Installation and connection possibilities:
- hose clamps
- hose reducers
- hose connectors
|
|
Today fresh, clean air in the workplace is to be expected and is considered an important productivity factor. You can make the grade with NORRES exhaust gas hoses.
Applications
Special exhaust gas hose, especially suitable
- for suction of engine exhaust gas
- for hose reel
- foe slotted floor channels
- for above and below floor suction extraction
Some properties of the NORRES exhaust gas hoses
- vibration resistant
- very good hest resistance
- minimum weight
- kink-proof
Temperature Range
-60 °C up to 900 °C (short time to +1100 °C approx.)
Wall thickness
0.4 mm approx.
|
|
Exhaust Gas Recirculation
Applications of Flexfab's charge air cooler hose or CAC...
Special pressure sensor hose, used to sense pressure differential between the exhaust manifold and the EGR tube. Connector temperatures to 450°F with no flow.
|
|
AG 2100 MARINE corrugated
Marine engine wet exhaust systems where the exhaust gases are mixed with the discharge of cooling water.
From 76 to 205 mm.
|
|
LPG®
Properties
Can be installed quickly and simply, with no need for welding or X-ray tests. Just single compression connectors at the start and end of the entire pipe
LPG®
Installation/assembly of a special steel pipe for high pressure, large lengths.
Area of application:
transport of liquid and gaseous media.
Structure
Flexible, endless production, single-wall, mechanically reinforced pipe system. Medium pipe: special steel
|
|
straight-way type, for connecting to gas sockets models G2016 and G2019, inlet: Bayonet connection male, outlet: female thread, internal hose: stainless steel corrugated hose, external hose: rugged agraff hose made of stainless steel,
ambient temperature max. 70 °C, working pressure 0,1 bar,
|
|
Methane Gas Recovery Hose
(Landfill Hose)
Used on the well head, Flexfab's Methane Gas Recovery Hose provides a durable, flexible solution.
Flexfab's hose consists of two layers of spiral wound black Chloroprene coated fiberglass fabric with wire helix between the plies.
A loose orange hose jacket of conductive silicone coated fabric protects the inner liner from ultraviolet, ozone, and shields from abrasion
LEAKAGE: Zero leakage under water at 1 psi
MINIMUM CENTERLINE BEND RADIUS: 1 1/2 times the hose inside diameter
WALL THICKNESS AT CUFF: 0.090" to 0.065" - (except at fabric overlaps)
VACUUM CAPABILITY: 1" TO 6" ID - 3 psi vacuum at 200ºF
TEMPERATURE RANGE: -40ºF ambient to +200ºF*
PROOF PRESSURE: 66% of burst pressure
INSIDE DIAMETER TOLERANCE: +/- .030"
CUFF LENGTH TOLERANCE: Plus 3/8", Minus 1/8"
LENGTH TOLERANCE:
- Plus 1/4" per foot of hose length or portion thereof
- Minus 1/8" per foot of hose length or portion thereof
|
|
Gas and welding
PLUTON TWIN EN 559
Twin line rubber hose for welding gas supply.
From 5 to 10 mm.
VULPANE EN 559
Rubber hose for LPG (gas cylinders, heaters, welding, and LPG lines).
From 5 to 10 mm.
|
|
Single line or twin line available
Tube: EPDM/SBR (NR/SBR) blended, black and smooth
Reinforcement: textile braided high tensile synthetic yarn
Cover: EPDM/SBR (NR/SBR) blended, Red, Blue, Green. smooth weather and ozone, abrasion resistant
Application: for conveying welding gases
Temperature: -40℃~+90℃
Length: as request
Packing: P.V.C. film, reel packing available
|
|
... see all the products in the category
Hoses
|
TODO-GAS® couplings are specifically designed for the safe transfer of LPG (typically Propane / Butane) in both liquid and vapour phases.
The materials of construction and component design are specified to recognise the unique properties of LPG and terminal handling characteristics.
Ultra low release on disconnection not only improves safety but also satisfies even the most stringent of environmental standards. Typical emission reduction is greater than 99% compared to existing thread based couplings.
Just like their TODO-MATIC® stable mates, TODO-GAS® couplings remove the human error element from LPG transfer operations by ensuring that the valves are closed before disconnection is possible. Both TODO-MATIC® and TODO-GAS® couplings offer the lowest fugitive emission volumes available in the world.
|
|
Threaded and welding fittings have been manufactured since TECVAL started its industrial activity. Fabricated in different materials and with an excellent finish quality they can work under high pressure service.
Made in several alloys.
|
|
| ... products without technical information |
| |
|
|
|
|
Anguil's HCl Scrubber Module scrubs and neutralizes hydrochloric acid that is created during the oxidation of halogenated or mixed organic vapor contaminants.
How the HCl Scrubber Module Works:
The outlet of a Chlorinated Oxidizer, is directed to the Anguil HCl Scrubber Module. A recirculation pump injects large volumes of water into a hastelloy quench section, inducing vapor flow through the scrubber. The water quenches the hot vapor and absorbs a portion of the HCl. The gases exit the eductor and enter a countercurrent absorption column. Recirculating solution is fed to the top of the absorption column through a nozzle. The remaining hydrochloric acid vapors are absorbed into the solution. The gases pass through a mist eliminator before exiting the column. Sodium hydroxide is added to control pH in the neutral range.
System Components:
Each Standard HCl Scrubber Module is fabricated from FRP and includes hastelloy quench, absorption column (consisting of a cylindrical tower filled with polypropylene spherical media), common liquid sump, recirculation pump, flanged inlet and outlet, hastelloy spray nozzle and liquid level indicator. The system components are assembled on an epoxy-painted steel base that is weather-resistant and corrosion-resistant.
The HCl Scrubber Module is designed as part of Anguil's broad line of technologically advanced, yet user-friendly, air pollution control products.
Anguil strives to provide innovative pollution control technology including process analysis, engineering, equipment manufacturing, installation and post-sale 24-hour service.
|
|
|
|
|
|
Bagasse fired boiler flue gas particulate emissions before dust collectors are ususally between about 8,000 and 12,000 mg/Nm3. This level of emission is unacceptable from an environmental point of view, and some form of dust collection is therefore essential.
Therefore, Fives Cail is exclusively licensed by Tongaat Hulett to propose a large range of gas scrubber.
The Tongaat-Hulett/Fives Cail Gas Scrubber is a rain tray type, vertical cylindrical unit, designed to remove solid particulate matter from boiler flue gases.
The internals consist of three major components that play distinct parts in the scrubbing process. These internals are as follows:
Inverted cone spray
Irrigated sieve plates
Vortex generator/Entrainment separator
Technology performance for the environment
Unique Performances
Particulate emission levels are typically less than 100mg/Nm3
10% of sulphur removed
Easy installation
Located output boiler
Easy adaptation in the workshop
Reduced maintenance
Minimum wear
No specific maintenance
No internal movings parts
|
|
Hydrodinamic wet filter IDRODUST COMPACTI® is a hydrodynamic machine for removal of dust, vapours and gases by means of micro-mixing the gas to be treated with water. Mixing is realized in a duct with a specially designed shape, where water is dragged for the depression created by the fan, where polluted air is centrifuged to enable dust trapping and/or absorption of gases. A high performance drop separator on the outlet avoids dragging of water. Water circulates without the aid of pumps or spraying nozzles, ensuring the reliability of the machine, whose parts are not subject to wear or clogging, reducing maintenance requirements.
APPLICATIONS
Idrodust Compact hydrodynamic wet filters can be used for processing involving sparks or wet dusts
|
|
FRIDURIT® flexible fume scrubbers
The FRIDURIT fume scrubber C20 has been specially designed for decentralised washing of harmful substances for precise extraction directly at source. He is equipped with an integrated fan and can be placed anywhere in the laboratory, e.g. on the worktop, the floor or where the installation of a built-in fume scrubbers is not possible due to shortage of space. Please refrain from installing the fume scrubber C20 inside fume hoods.
|
|
| ... products without technical information |
| |
|
|