Sensors for temperature and humidity, explosion proof
Transducer-/sensor conception for temperature and/or humidity measuring in hazardous areas, composed of a transducer series ExCon-D or RedCon-D and a sensor series ExPro, in acc. with ATEX 94/9/EG for use in hazardous areas zone 1, 2, 21 and 22, for all kind of gas, mixtures, vapours and dust. 24 VAC/DC supply, ranges from -40°C ... + 125°C or 0...100 % rF, as single measurement or combination of °C and %rF. Working range adjustable, output 0...10 VDC and 4...20 mA, actual value indication, aluminium housing in P 66, integral Ex-e terminal box. ExPro sensors are available with 50mm, 100mm, 150 mm and 200 mm length in acc. with type and can be connected to the transducer for room or duct mounting. series ExCon-D for use inzone 1, 2, 21, 22. series RedCon-D for use in zone 2, 22.
The module is for installation inside the hazardous area, an interface in the safe area is not required, installation of intrinsic safe circuit is not required. This saves cost, space and guarantees safety. |
|
Temperature sensors, humidity sensors, pressure sensors, frost protection thermostats, pressostats, explosion proof
Passive, potential free binary and modulating sensors, series ExSens, for temperature, humidity and pressure, with manufacturer certificate, in acc. with ATEX 94/9/EG for use in hazardous areas zone 1, 2, 21 and 22 (in acc. to sensor type), for all kind of gas, mixtures, vapours and dust.
Sensors for room, duct or tube mounting (in acc. to type).
Modulating sensors series ExSens connectable to transducers seriess ExCon-A, RedCon-A or EXL-IMU-1.
odulating sensors series ExPro connectable to transducers seriess ExCon-D and RedCon-D.
Binary sensors series ExSens connectable to switching module series EXL-IRU-1 |
|
| Relative humidity sensors from Sensirion have become the market standard, since they were launched in 2002. Nowadays the company yearly sells millions of humidity sensors all around the world. The sensor solutions are designed for diverse applications such as data logging, climate control, and antifogging. They hence measure relative humidity and temperature in different kind of products. The digital humidity sensors work with a capacitive measuring principle. Thanks to its unique CMOSens® technology, the humidity sensors allow precise humidity and temperature measurement at low cost. |
|
This digital, modular sensor with PMU Plug-and-Measure unit measures the relative humidity and temperature and calculates to output the values of the dew point temperature, water content, enthalpy, absolute humidity and wet bulb temperature.
|
|
| ... products without technical information |
| |
For demanding applications in high-temperature areas, inductive proximity switches with good long-term reliability have become increasingly popular. Contrinex offers a series of embeddable and non-embeddable HT switches in sizes M8 to M50. The devices have operating distances from 2 to 25 mm, and are respectively suitable for applications up to 140°C, 150°C, 180°C and 230°C.
The executions for 140°C, 150°C and 180°C feature built-in amplifiers. Connections by means of a 2 m silicone or Teflon cable is standard. Other cable lengths and types are available on request.
For 230°C types, the amplifiers are built into an M12 stainless-steel housing, which is connected by means of a standard 2 m Teflon cable, and thus removed from the hot area. This cable carries a pure DC, rather than a high-frequency signal, and its length can thus be chosen freely, without having a negative influence on the switching behavior of the device, and without the need for adjustment. Connection of the amplifier is by means of a 2 m PUR cable.
All the usual protection functions, such as short-circuit, overload and voltage-reversal protection are built in. Furthermore, the devices feature good protection against environmental influences (IP 67). |
|
The high temperature sensors should be considered
as part of the traditional range of sensors with the difference
that electronic portion is completly separate
from the sensing part which is in the form of an extension
and can withstand temperatures up to 250°C.
These products are used to control the levels of hot
materials such as liquids, oil, powder and plastic
granules. They also sense solid metallic and nonmetallic
bodies positioned in areas of high temperature.
The connecting cable between the sensor and
the amplifier must be of standard length (2m or 5m).
It resists to temperatures from -200 to +250°C it is
connected to the sensor and it is provided with a
shielded connector for connection to the amplifier. The
amplifier is supplied in two different types, a model
which is suitable for one sensor and a model which is
suitable for two sensors. The sensors can be supplied
in the following formats M18x1 and M30x1.5. |
|
| Capacitive sensors (KAS) react to metals and non-metals that exceed a specific capacitance on approaching the active surface. The sensing distance with respect to a specific material is greater the higher the dielectric constant. The sensors are used to detect objects, for counting functions and for all types of level monitoring applications in liquid materials (i.e. water, oil, acids, glue) and bulk materials (i.e. pouder, granulate, pellets). |
|
HIGH TEMPERATURE SENSORS
Significant scientific and engineering enhancements in advanced materials, Pre-Process and In-Process production methods and in-site testing methods are driving the demand for displacement sensors that can handle extremely high temperatures up to 1832°F (1000°C). Contemporary producers of aircraft engine rotational alignment, plate glass, materials testing extensometry, continuous flow steel, now use standardized high temperature Capacitec sensor solutions for in-process applications to control the quality of their production on a real time basis. Qualification testing of disc brakes, jet engine dynamics and high speed shaft rotations also rely on Capacitec sensors. Advanced materials for automobiles, structural components, and aircraft are also tested for strength and durability with the use of Capacitec's line of extensometers and clip gauges.
High Temperature Major Applications:
- Disc brake testing
- Silicon Wafer processing
- Metal and Glass forming
- Jet engine thermal expansion
- Material strength testing
- Mold separation
- Turbine testing
- Strain Extensometry
|
|
| The capacitive high temperature sensors are especially suitable for applications where the sensor head is exposed to a high ambient temperature, or comes directly into contact with hot materials. |
|
| Significant scientific and engineering enhancements in advanced materials, Pre-Process and In-Process production methods and in-site testing methods are driving the demand for displacement sensors that can handle extremely high temperatures up to 1832°F (1000°C). Contemporary producers of aircraft engine rotational alignment, plate glass, materials testing extensometry, continuous flow steel, now use standardized high temperature Capacitec sensor solutions for in-process applications to control the quality of their production on a real time basis. Qualification testing of disc brakes, jet engine dynamics and high speed shaft rotations also rely on Capacitec sensors. Advanced materials for automobiles, structural components, and aircraft are also tested for strength and durability with the use of Capacitec's line of extensometers and clip gauges. |
|
T500 Elite - HotBus system
- Serial Network for Continuous Remote Sensor Monitoring
- Preventative maintenance tool fully compatible with existing systems
- Accepts input signals from a total of 256 sensors
- User adjustable trip-points for alarm & shut-down
- “BUS VIEW” Easy-to-use graphical monitoring software available
- Utilises the "HotBus" communications system |
|
Centralized monitoring and traceability of the temperatures
New LABGUARD 2 version 3.7 with alarms in real time and function back up!
AES CHEMUNEX presents version 3.7 of system LABGUARD 2. Already adopted by many laboratories in France and abroad, LABGUARD 2 is an acquisition unit and of monitoring of the temperatures (and other parameters like: relative humidity, differential pressure, CO2, O2, contacts dry...). The transmission of the data in real time by radio of the emitters towards the receiver and the computer avoids any wiring and allows a very simple and fast installation as well as a very great flexibility.
The software, conforms CFR21 leaves 11, presents a total traceability: the data base is made safe and the software delivered with file of validation (service IQ, OQ available). The new version of the software integrates the function "back up": the data are recorded in each module and can thus be recovered in the event of stop or of computer breakdown. The data security is maximum. The emitters can be supplied with battery cell and/or sector.
The software is conceived in a modular way, various optional modules make it possible to meet the needs for each user (mapping, reference of alarms, localization of the apparatuses at fault, remote consultation, interfacing software quality...)
|
|
Measuring range : from 0/+10 Pa to -10 000/+10 000 Pa
Configurable intermediary and central zero ranges
Air velocity and airflow functions
Interchangeable measuring sensor (SPI technology)
Simultaneous display of 1 to 4 parameters
External transmitter unputs (KIMO class 200 and 300) and thermocouple K
2 output 4-20 mA or 0-10 V (4 wires), RS 232, 2 RCR relays 6A/230 Vac
2 visual (dual color LED) and audible (buzzer) alarms
Software, keypad or remote control configuration
MODBUS network RS 485 system (optional)
ABS or ALU IP 65 housing, with or without backlit gaphic display
Mounting with the 1/4 turn system with wall-mount plate
CP301 : -100/+100 Pa
CP302 : -500/+500 Pa
CP303 : -1000/+1000 mbar
CP304 : -10 000/+10 000 mbar
• Barbed fittings Ø 5,2 mm
• Unit of measurement : Pa, mmH2O, mbar, inWG, mmHG
• Power supply : 24 Vac /Vdc, 115 Vac or 230 Vac
• Outputs : 2 x 4-20 mA or 2 x 0-10 V
• Functions : pressure, air velocity, airflow with Pitot tubes, Debimo and other coefficients, integration of measure, self-calibration, measuring correction factor, temperature compensation : manual or automatic (thermocouple K input). |
|
Technical details
- Protection class I (ground wire) - protection type IP 54 (DK = IP 20)
- Temperature setting:
ON 25 °C - OFF 55 °C (operating temperature of heating
system itself)*
Tropical version possible: ON 35 °C - OFF 65 °C
-> Other settings upon request
- 2 Connecting alternatives (optional)
Connecting leads (AL) 0.5 m, 3 x 0.75 mm² PVC
- > Other lengths upon request
Lead out terminal (DK) 0.08 - 2.5 mm²
- Mounting position: vertical
- 2 fastening alternatives (optional)
Snap fitting for 35 mm DIN rail (figure 1)*
Screw fastening (figure 2) |
|
PTC units for DIN bar application.
EH/FH heaters, installed separately from cooling unit, must be connected to TMC thermostat. When used to prevent cabinet condensate they should be eletrically connected also when cabinet is off.In this cabinet it’s better to install more heating elements with small heating power.In this way there is an optimal air temperature distribution. |
|
Heaters
Voltage: AC 220V
Power: 50W, 75W, 100W, 150W, 200W, 300W, 500W
Power frequency withstand voltage: 2kV
Operating life: „5 years
Temperature & humidity controllers
Power supply: AC220V}10%i50HZj
Withstand voltage: 2 kV
Controlled temperature precision: }1Ž
Action humidity point: 93%RH or 80%RH
Range of target temperature: 5Ž~15Ž |
|
Low surface temperature
Integrated thermostat
Quick mounting due to clip fixing
Double insulated (plastic)
Wide voltage range
Small size
Compact heater for the use in enclosures with electrical/electronical components. The design of the heater supports the natural convection which results in a high air-current of warm air.
The surface temperatures on the accessible side surfaces of the housing are kept down as a result of the heater design.
This model with plug-in thermostat does not require additional wiring.
The heaters are designed for permanent operation.
This heater is also available in a version without thermostat (CS 060). |
|
LAUDA Integral XT - Process thermostats for thermostating in an extremely wide temperature range from -90 up to 300 °C. With their high heating, cooling and pump capacities, LAUDA Integral XT process thermostats create a new thermostating dimension in process engineering. The basic principle comprises a circulation thermostat with a very small internal volume and non-perfused expansion vessel.
LAUDA Integral XT process thermostats are equipped with the Command console as standard. Thanks to the intuitive menu-driven operation, the device settings are easy to use. Dynamic processes or other difficult thermostating tasks are safely mastered thanks to the use of high-performance technology.
Performance profile:
✜ High-resolution, back-lit graphic LCD display for depicting the entire thermostating system, and with individuallyadjustable surface
✜ Real-time clock combined with timer function
✜ Editable programmer for up to 150 segments in five programs
✜ Nine pre-defined sets of parameters can be selected for the control
✜ Menu-driven operation in German, English, French or Spanish
✜ Function lights for heating, cooling and external control
✜ Error reports by means of bright LED lights, acoustic alarm and clear text message
✜ Vario pump with eight steps and adjustable limit of the pump pressure
✜ Integrated external control with cascade connection
✜ Supply temperature limit for the gentle heating of the external system
✜ Integrated opto-decoupled RS 232/485 interface as standard
✜ Freely scalable graphic display of the temperature variation |
|
The LAUDA Integral T is the trademark which stands for extremely efficient process thermostats in a compact design. As generalist for fast, precise thermostating in the external circuit, they easily master the most demanding tasks. The most popular fields of applications are process engineering, production and research.
Integral T process thermostats make possible rapid thermostating with powerful heating and cooling capacities combined with a small active internal volume. This minimises thermal ballast and exothermic reactions are effectively controlled. Its compact construction is space-saving and makes the Integral T mobile.
Powerful for indirect thermostating tasks:
Integral T process thermostats are particularly suitable for the external thermostating of reactors, mini plants and calorimeters, whereby wide temperature ranges and fast temperature changes are essential. Fields of application: process engineering, production, research.
Performance profile of the Integral T:
✜ Programmer with max. 150 temperature/time segments, divided into 5 programs, with loop, change and pause function
✜ Parallel display of 2 temperature values with a resolution of 0.1 °C
✜ Discharge pressure display
✜ External control via Pt 100 temperature probe or standard signal
✜ User calibration and LAUDA 2-point calibration
✜ Analogue inputs (3) and outputs (2), e.g. for control system. Can be configured to 0...10 V or 0/4...20 mA
✜ Malfunction indication for low level, overtemperature, pumps and cooling compressor
✜ Remote "malfunction” display via neutral contact
✜ Stand-by switch via neutral contact
✜ RS 232/485 interface for PC and LAUDA Wintherm Plus control software |
|
We offer you a comprehensive program of metalblock thermostats for precise tempering of samples in the range of -20 up to + 600°C. The thermostats up to 210 °C are furnished with heating bathes for interchangeable or with permanently installed heating blocks. The standard product lines you will find on the following pages are:
HP "High Performance" Thermostats up to 130°C /210°C
BIO "BIO"Thermostats up to 130°C
HT "High Temperature" Thermostats up to 300°C/400°C
HC "Heating, Cooling" Thermostats -20°C up to + 130°C
EC "Economy" Thermostats up to 130°C / 210°C
LS "Life Sciences" Thermostats up to 130°C
QS "Squared heating sink" Thermostats bis 130°C/210°C
SPA "Special Applications" Thermostats dedicated for determined analytical methods or for material testing
Moreover we offer "tailor made" Thermostats pursuant to your individual requirements. Benefit from our experience in chemistry and particularly in the design of advanced metalblock thermostats. A qualified consultancy belongs to our range of performances. If you are searching for a safe nad most convenient solution by applying a "dry bath" instead of an water- or oilbath please give us a call +49 (0) 5202 919930.
|
|
|
|