Sensors for temperature and humidity, explosion proof
Transducer-/sensor conception for temperature and/or humidity measuring in hazardous areas, composed of a transducer series ExCos-D or RedCos-D and a sensor series ExPro, in acc. with ATEX 94/9/EC for use in hazardous areas zone 1, 2, 21 and 22, for all kind of gas, mixtures, vapours and dust. 24 VAC/DC supply, ranges from -40C ... + 125C or 0...100 % rH, as single measurement or combination of C and %rH. Working range adjustable, output 0...10 VDC and 4...20 mA, actual value indication, aluminium housing IP 66, integral Ex-e terminal box. ExPro sensors are available with 50 mm, 100 mm, 150 mm and 200 mm length in acc. with type and can be connected to the transducer for room or duct mounting. Series ExCos-D for use in zone 1, 2, 21, 22. Series RedCos-D for use in zone 2, 22.
The module is for installation inside the hazardous area, an interface in the safe area is not required, installation of intrinsic safe circuit is not required. This saves cost, space and guarantees safety.
|
|
Temperature sensors, humidity sensors, pressure sensors, frost protection thermostats, pressostats, explosion proof
Passive, potential free binary and modulating sensors, series ExSens, for temperature, humidity and pressure, with manufacturer certificate, in acc. with ATEX 94/9/EC for use in hazardous areas zone 1, 2, 21 and 22 (in acc. to sensor type), for all kind of gas, mixtures, vapours and dust.
Sensors for room, duct or tube mounting (in acc. to type).
Modulating sensors series ExSens connectable to transducers series ExCos-A, RedCos-A or EXL-IMU-1.
Modulating sensors series ExPro connectable to transducers series ExCos-D and RedCos-D.
Binary sensors series ExSens connectable to switching module series EXL-IRU-1.
|
|
Measurement Range 25 to 95% RH
Scales C or F, %RH
Resolution 1, 1% RH
Accuracy
Temperature
0C to + 40C 1C
+32F to +104F 2F
Full range 2C/4F
Humidity
40 to 80% RH, +15C to +40C,
+59F to +104F 5% RH
below 40% or over 80% RH 7% RH
|
|
Plug on sensor: humidity and temperature Part No.: 3087
- For ECOLOG THx or ECOLOG-NET LH2, WH2
- Range: temperature: -35..+70C
- rH: 0%..100%
- With calibration certificate
|
|
|
Relative humidity sensors from Sensirion have become the market standard, since they were launched in 2002. Nowadays the company yearly sells millions of humidity sensors all around the world. The sensor solutions are designed for diverse applications such as data logging, climate control, and antifogging. They hence measure relative humidity and temperature in different kind of products. The digital humidity sensors work with a capacitive measuring principle. Thanks to its unique CMOSens technology, the humidity sensors allow precise humidity and temperature measurement at low cost.
|
|
|
HITY 2000 is based on impedance measurement rather than the capacitive method used by other systems. This technology offers an extremely high degree of resistance against aggressive chemical gases and provides stability for as long as 5 years, depending on the medium. The sensor reacts to humidity changes much faster than average.
|
|
This digital, modular sensor with PMU Plug-and-Measure unit measures the relative humidity and temperature and calculates to output the values of the dew point temperature, water content, enthalpy, absolute humidity and wet bulb temperature.
|
|
| ... products without technical information |
| |
Mainly based on the float switch design, these controllers help to monitor the liquid level (as combined units they monitor both liquid level and temperature) in oil reservoirs of fluid power and lubrication systems.
Attached to the tank top cover, they penetrate directly into the hydraulic fluid or the lubricant.
Each of the following series offers particular features and details culminating in the extreme density of functions offered by the Multiterminal.
Level switch Fluidcontrolterminal series
High number of functions reduces requirements for installation, space and cost
Adjustable level contacts
Connecting flange according to DIN 24 557 part 2
Directly attached electronic contact thermometers optional
The FC terminals offer the functions of tank breathing, level/temperature control, filling and topping up and oil sampling in a very compact design.
|
|
Level and temperature switch
Multiterminal
All basic functions in one unit:
Return line filter
Breather filter
Level and temperature controls
Filling port (optional with electrical close loop shut off)
Sample ports
Advanced filter capacity controller
The very compact design saves space and installation cost.
|
|
Level measurement instrument in stainless steel 1.4571
with integrated temperature sensor
TN 210
Characteristics:
Analog level signal 4-20 mA, two-wire transmitter
Max. 4 level switches (bistable) pnp-output. Control elements: reed contacts or magnet sensors
Analog temperature signal 4-20 mA, two-wire transmitter
Temperature switches: pnp-output or thermostat for switch action
Advantages:
Reductions of costs: max. 4 different measurements in one measuring instrument
Economy of time, of storage costs, of assembly costs etc.
Areas of application:
IMB combined measuring instruments are suitable even for rough environments and are applicable in the following industries:
plant engineering, off-shore, machine construction, power plants, chemical industrie, ship-building, biochemical industrie, food industrie, petrochemical industrie, pharmaceutics etc.
|
|
Technical details
- Protection class I (ground wire) - protection type IP 54 (DK = IP 20)
- Temperature setting:
ON 25 C - OFF 55 C (operating temperature of heating
system itself)*
Tropical version possible: ON 35 C - OFF 65 C
-> Other settings upon request
- 2 Connecting alternatives (optional)
Connecting leads (AL) 0.5 m, 3 x 0.75 mm PVC
- > Other lengths upon request
Lead out terminal (DK) 0.08 - 2.5 mm
- Mounting position: vertical
- 2 fastening alternatives (optional)
Snap fitting for 35 mm DIN rail (figure 1)*
Screw fastening (figure 2)
|
|
PTC units for DIN bar application.
EH/FH heaters, installed separately from cooling unit, must be connected to TMC thermostat. When used to prevent cabinet condensate they should be eletrically connected also when cabinet is off.In this cabinet its better to install more heating elements with small heating power.In this way there is an optimal air temperature distribution.
|
|
Heaters
Voltage: AC 220V
Power: 50W, 75W, 100W, 150W, 200W, 300W, 500W
Power frequency withstand voltage: 2kV
Operating life: 5 years
Temperature & humidity controllers
Power supply: AC220V}10%i50HZj
Withstand voltage: 2 kV
Controlled temperature precision: }1
Action humidity point: 93%RH or 80%RH
Range of target temperature: 5~15
|
|
Low surface temperature
Integrated thermostat
Quick mounting due to clip fixing
Double insulated (plastic)
Wide voltage range
Small size
Compact heater for the use in enclosures with electrical/electronical components. The design of the heater supports the natural convection which results in a high air-current of warm air.
The surface temperatures on the accessible side surfaces of the housing are kept down as a result of the heater design.
This model with plug-in thermostat does not require additional wiring.
The heaters are designed for permanent operation.
This heater is also available in a version without thermostat (CS 060).
|
|
They should be considered as part of the traditional range of
sensors with the difference that electronic portion is
completely separate from the sensing part which is
in the form of an extension which can withstand temperature
from -200 +250 C.
These products are used to control the levels of hot
materials such as liquids, oil, powder and plastic granules.
They also sense solid metallic and non-metallic bodies positioned
in areas of high temperature. ALSC Amplifier in plastic housing
with UNDECAL PLUG
-Supply voltage: 24Vac or 110/220 Vac
-ALSC-1 CH type suitable for one sensor
-ALSC-2CH type suitable for two sensors
-Led incorporated
-Sensitivity adjustment
-Relay output changeover 5A to 220 Vac
Sensors for high temperature: stainless steel housing
M18 and M30, sensitive side PTFE
-Provided with connector for connection to the amplifier
-cable length: 2 or 5 metres
-min./max. working temperature from -200 +250 C
-sensing distance: 5 mm for type SC18M-HT and 15 mm for
type SC30M-HT
-degree of protection: IP68
|
|
HIGH TEMPERATURE SENSORS
Significant scientific and engineering enhancements in advanced materials, Pre-Process and In-Process production methods and in-site testing methods are driving the demand for displacement sensors that can handle extremely high temperatures up to 1832F (1000C). Contemporary producers of aircraft engine rotational alignment, plate glass, materials testing extensometry, continuous flow steel, now use standardized high temperature Capacitec sensor solutions for in-process applications to control the quality of their production on a real time basis. Qualification testing of disc brakes, jet engine dynamics and high speed shaft rotations also rely on Capacitec sensors. Advanced materials for automobiles, structural components, and aircraft are also tested for strength and durability with the use of Capacitec's line of extensometers and clip gauges.
High Temperature Major Applications:
- Disc brake testing
- Silicon Wafer processing
- Metal and Glass forming
- Jet engine thermal expansion
- Material strength testing
- Mold separation
- Turbine testing
- Strain Extensometry
|
|
|
Capacitive sensors (KAS) react to metals and non-metals that exceed a specific capacitance on approaching the active surface. The sensing distance with respect to a specific material is greater the higher the dielectric constant. The sensors are used to detect objects, for counting functions and for all types of level monitoring applications in liquid materials (i.e. water, oil, acids, glue) and bulk materials (i.e. pouder, granulate, pellets).
|
|
For demanding applications in high-temperature areas, inductive proximity switches with good long-term reliability have become increasingly popular. Contrinex offers a series of embeddable and non-embeddable HT switches in sizes M8 to M50. The devices have operating distances from 2 to 25 mm, and are respectively suitable for applications up to 140C, 150C, 180C and 230C.
The executions for 140C, 150C and 180C feature built-in amplifiers. Connections by means of a 2 m silicone or Teflon cable is standard. Other cable lengths and types are available on request.
For 230C types, the amplifiers are built into an M12 stainless-steel housing, which is connected by means of a standard 2 m Teflon cable, and thus removed from the hot area. This cable carries a pure DC, rather than a high-frequency signal, and its length can thus be chosen freely, without having a negative influence on the switching behavior of the device, and without the need for adjustment. Connection of the amplifier is by means of a 2 m PUR cable.
All the usual protection functions, such as short-circuit, overload and voltage-reversal protection are built in. Furthermore, the devices feature good protection against environmental influences (IP 67).
|
|
|
The capacitive high temperature sensors are especially suitable for applications where the sensor head is exposed to a high ambient temperature, or comes directly into contact with hot materials.
|
|
T500 Elite - HotBus system
- Serial Network for Continuous Remote Sensor Monitoring
- Preventative maintenance tool fully compatible with existing systems
- Accepts input signals from a total of 256 sensors
- User adjustable trip-points for alarm & shut-down
- “BUS VIEW” Easy-to-use graphical monitoring software available
- Utilises the "HotBus" communications system
|
|
Control your storage & incubation conditions
Guarantee your products quality
Ensure a complete traceability of the monitored parameters
LABGUARD 2 is THE solution...
Simple and wireless, it measures and records
in real time the different parameters : temperature, humidity, pressure, CO2...
and manages alarm in real time.
In one screen and a few clicks only...
|
|
|
Significant scientific and engineering enhancements in advanced materials, Pre-Process and In-Process production methods and in-site testing methods are driving the demand for displacement sensors that can handle extremely high temperatures up to 1832F (1000C). Contemporary producers of aircraft engine rotational alignment, plate glass, materials testing extensometry, continuous flow steel, now use standardized high temperature Capacitec sensor solutions for in-process applications to control the quality of their production on a real time basis. Qualification testing of disc brakes, jet engine dynamics and high speed shaft rotations also rely on Capacitec sensors. Advanced materials for automobiles, structural components, and aircraft are also tested for strength and durability with the use of Capacitec's line of extensometers and clip gauges.
|
|
Measuring range : from 0/+10 Pa to -10 000/+10 000 Pa
Configurable intermediary and central zero ranges
Air velocity and airflow functions
Interchangeable measuring sensor (SPI technology)
Simultaneous display of 1 to 4 parameters
External transmitter unputs (KIMO class 200 and 300) and thermocouple K
2 output 4-20 mA or 0-10 V (4 wires), RS 232, 2 RCR relays 6A/230 Vac
2 visual (dual color LED) and audible (buzzer) alarms
Software, keypad or remote control configuration
MODBUS network RS 485 system (optional)
ABS or ALU IP 65 housing, with or without backlit gaphic display
Mounting with the 1/4 turn system with wall-mount plate
CP301 : -100/+100 Pa
CP302 : -500/+500 Pa
CP303 : -1000/+1000 mbar
CP304 : -10 000/+10 000 mbar
Barbed fittings 5,2 mm
Unit of measurement : Pa, mmH2O, mbar, inWG, mmHG
Power supply : 24 Vac /Vdc, 115 Vac or 230 Vac
Outputs : 2 x 4-20 mA or 2 x 0-10 V
Functions : pressure, air velocity, airflow with Pitot tubes, Debimo and other coefficients, integration of measure, self-calibration, measuring correction factor, temperature compensation : manual or automatic (thermocouple K input).
|
|
|
|