D.C. Electro-pumps, series ET...
The essential components of series ET elektro pumps are an external gear pump and an elctro motor.
The 12 and 24 VDC motors feature high efficiencies and precision-balanced rotors for low-vibration running. They are combined with our AP05 - AP100 external gear-pumps to produce the ET series of electro-pumps, a family of products that are notable for their low noise levels in operation.
Simplicity of construction and reduction in size are the fundamental objectives in the design of the ET electro-pumps.
Advantages
Noise levels have been drastically reduced
Wide range of displacements and electric motor
|
|
Sauer-Danfoss offers a wide variety of open circuit products. Our fixed and variable displacement pumps provide power for work functions of on- and off-highway vehicles and equipment in the fields of agriculture, construction, material handling, many others.
Fixed displacement gear pumps and motors and variable displacement piston pumps are a perfect choice when equipping applications like forklift trucks, tractors and road rollers.
Our portfolio includes tailor made pump solutions, in which several functions are integrated in one body to optimize size and cost. By combining products we can offer system solutions for buses, wheel loaders and other heavy equipment.
|
|
|
PVL are variable displacement vane pumps equipped with mechanical compensator for outlet pressure and max displacement adgustment. these low noise pumps are available in 3 different size, have flange ports according to ISO 3019/2 and are designed to operate with anti - wear oil
|
|
Low pressure pumps
Applications: Transport and circulation of liquids with lubricating properties,
like e.g. lube oils, fuel oils and synthetic and vegetable oils.
The ACD pumps are used for a number of different fluids:
Lubrication oil, fuel oil, vegetable oil, hydraulic oil and other hydraulic fluids,
glycols, polymers, emulsions, and any nonaggressive fluid with some lubricating properties.
Typical application are:
• Lubrication of diesel engines, gears, gas and steam turbines, hydro turbines, paper machines.
• Circulation for cooling and filtration in large machineries and hydraulic systems, pumping transformer oil for insulation in transformers.
• Transfer onboard ships, in oil factories, refineries, tank farms etc.
|
|
|
Bareshaft supported by ball bearings housed in oil bath, driven by electric motors or diesel engines with a flexible coupling. Their robust design and mechanical strength, makes them easy to use, reliable and economic.
|
|
PB 32.5 fixed displacement
Displacement: 0.0027cu.in/rev
(0.045cm3 /rev)
5080PSI (350bar)
5000rpm
3 pistons
Maximum operating temperature: 392°F (200°C)
Weight: 0.66lbs (0.3kg)
Rotates either CW or CCW
Excellent suction properties
The following may be modified on request:
■ input and outlet ports,
■ mounting flange or thread,
■ drive shaft,
■ addition of a filter/screen.
|
|
Lee Pre-Set and Variable Volume Pumps are the solution for automated chemistry systems. Designed for "install and forget" operation with outstanding features and performance.
* Standard volume ranges: 50 µl, 250 µl, 750 µl per full stroke
* Full volume dispense as fast as .3 seconds for Pre-Set Pumps, 1 second for Variable Pumps
* Low Power Consumption means less heat in the cabinet to manage
* Long Life -- Millions of cycles
* Compact -- Made small to fit inside the machine, near the chemistries
* Light Weight -- Made light to fit on moving arms, gantries, etc.
* Robust construction
* Many custom configurations possible
* 100% inspected and function tested
|
|
PMP - Mini pumps
• Two models for connecting either one (PMP1211) or two tools (PMP1221).
• Operates one tool at a time.
• Black painted protection frame with rubber feet.
• Effective cooling during operation.
Mini pumps are the right choice when there is need for small and portable pumps for quick rescue tasks. When space is highly limited and therefore valuable, a mini pump may be the solution for your tool problem.
|
|
Why use a variabledisplacement pump?
•precise control of all movements ;
• multi-function capabilities: simultaneous movements, all independant
of load ;
• avoid problems of fluid overheating ;
• reduce energy consumption.
Variable displacement : only advantages !
Installing a TXV variable displacement pump will transform your hydraulic equipment. Slow or rapid movements are done with precision, to the constant adjustment of pump flow rate. The TXV ranges are the result over 40 years' experience in hydraulic pumps. HYDRO LEDUC, France's leading pump manufacturer, is proud to present these high performance products.
|
|
The 2GP are EBARA booster units with two identical single-phase or three-phase
motor-driven pumps.
The 2GP Ebara pressure booster sets, in standard versions, can be used for residential, commercial, industrial and agricultural applications, namely for: water lifting or handling, cooling, heating, irrigation, washing systems.
The liquid carried can be: clean water, drinking water, rainwater, well water, mixed water, provided it does not contain solids or fibres in suspension and is free of aggressive chemical substances. Units must be installed in a shelter
of some kind and protected from the elements and frost.
•Temperature of water carried in the range 0 to 50 °C (depending on the kind of pumps installed).
• Ambient operating temperature in the range 0 to 40 °C at an altitude of no more than 1,000 m above sea level.
• Relative humidity max. 50% at +40 °C.
|
|
The Flojet 2840 Series Booster Systems are designed to provide a constant water pressure of 0 to 40 psi (0.7 to 2.7 bar) and a maximum flow rate of 4.5 gpm at 10 psi (0.7 bar). The pump is fully automatic, with built in inlet strainer, pressure switch, and check valve, and supplies smooth flow from tricke to full flow. Typical uses include applications where available water pressure is very low, and fluctuates widely. Easy installation requires only that the water lines be connected, and the power cord plugged in.
Features::
• Integrated pump and tank system
• May be mounted vertically or horizontally
• Flow rates up to 4.5 US Gallons/min (17 Lires/min)
|
|
Type PR4-Mini:
- Sizes 0.4 to 2.0
- Radial piston pump with 3 pistons
- Very compact build, hence installation-friendly dimensions
- 5 sizes
Type PR4:
- Sizes 1.6 to 20.0
- Radial piston pump with 3, 5 or 10 pistons
- Self-aspirating, valve-controlled
- Long bearing life due to hydro-dynamically lubricated plain bearings
- Several pressure ports with various cylinder combinations possible
- Optional combination with fixed and variable displacement vane and axial piston pumps
-14 sizes, favourable gradation for optimum matching to the application at hand
|
|
|
Compact design. With integrated low-pressure switch-off valve and high-pressure pressure limiting valve. Direct installation of motor without bell housing and coupling.
|
|
|
Highly efficient self priming Positive Displacement Sliding Vane Pumps for LPG, Propane, Butane & DME. Designed and precision built to optimise all the advantages of the sliding vane principle. Automatic compensation for vane wear assures the pump will maintain its superior vapour handling and operational efficiency over a long service life. Smooth output flow ensures quiet operation within the NPSH range. The pumps can be direct-coupled to synchronous speed motors.
|
|
Vane pumps, fixed displacement
Types PVV, PVQ:
- Sizes 18 to 193
- Low operating noise
- Low flow pulsation
- Suitable for wide speed and viscosity ranges
- Combination of several pumps possible
- Can be combined with axial piston pumps and internal gear pumps
Vane pumps, direct operated
Type PV7...A:
- Sizes 10 to 25
- Very short control times
- Low operating noise
- Lower zero stroke power
- Mounting and connection dimensions according to VDMA 24 560/1 and ISO 3019/2
- Good efficiency
- Pump combination possible
Vane pumps, pilot operated
Type PV7:
- Sizes 14 to 150
- Variable displacement
- Low operating noise
- Pressure and flow can be controlled
- Controller actuator can optionally be locked
- Low hysteresis
- Very short control times
- Pump combination possible with standard pumps
- Mounting and connection dimensions according to VDMA 24 560/1 and ISO 3019/2
|
|
Single Pumps
These pumps are of high pressure and high performance, which have been developed especially for low noise operation. To comply with a variety of applications including injection moulding machines, PV2R series single
pumps provide the output flow of such a wide range as from 5.8 to 237 cm3 /rev (.354 to 14.46 cu.in./rev).
The intergral driving parts of the pumps are combined into a kit form and available for supply as a cartridge kit.
Therefore, the replacement of the driving parts can be done easily.
Double Pumps
These double pumps consist of two PV2R series single pumps combined in tandem within a single housing anddriven by a common shaft. A Single suction port and two discharge ports are provided so that the output flow can be supplied to separate circuits.
|
|
Capacity to control minimum displacement
The DELTA pumps are designed to regulate flow from maximum flow to flow cancellation mode. However, some applications require a minimum outlet flow to be maintained, regardless of how flow is controlled from maximum to minimum.
Capacity to have a high speed rotation
The rotating speed of the DELTA pumps depends on:
• flow supplied by the pump,
• the fluid viscosity,
• the pressure at inlet point of the pump.
For applications at higher speeds than those indicated, please contact our Technical Department with details of these parameters, to enable us to advise what can be recommended.
■ Features of DELTA pumps
The DELTA pumps are equipped with a maximum displacement control.
|
|
|
These AR series pumps heve been developed on the basis of the same design concept as A series pumps which are renowned for high efficency and low noise level. Using an alminum body, the size of the pump is more compact and the mass is considerably reduced. The noise level has also been reduced.
|
|
|
|
|
|
The variable volume, pressure compensated design features of this pump combined with significant advancements in noise reduction make this pump a perfect match for many industrial applications.
The controls available provide for standard pressure compensation, load sensing, remote pressure control, and horsepower limiting. These control options permit the machine designer to utilize efficient pump controls that are tailored for the requirements of a hydraulic system. PVX controls are available in both single stage and two stage designs. All of the PVX controls exhibit very good response and recovery times and can incorporate a shock clipper that reduces shock pressure by up to 50%. This feature increases system component life and system stability.
The hydrodynamic journal bearing design is a feature that enhances the quiet operation of this pump, and eliminates the B-10 rating of the unit. A one piece rotor shaft contributes to this rugged design with minimized deflection when under high system loads. The rotor design allows the designer to easily configure a tandem mount rear drive option that provides the flexibility of driving multiple pumps with a common input shaft. This eliminates the need for additional prime movers, when multiple pumps are required.
Porting plates that provide proper timing for the inlet and discharge cycles of the pump, are designed for efficient and quiet operation. These pressure loaded port plates provide optimum running clearance to the rotor and contribute to high volumetric and overall efficiency.
Specifications
Mountings: SAE and ISO mounts
Capacities: 8 to 75 GPM
Operating Pressures: 200 to 3000 PSI
Recommended Fluids:
Petroleum-base, most phosphate esters, water emulsions and water glycol
|
|
|
|
|
|
Our range of Variable Displacement Pumps are some of the most reliable on the hydraulic market. We offer a wide range of displacement ranges, pressure ratings, speed ratings, and types of mounting configurations to meet your needs.
Designed for power and speed, PVV open loop, axial piston hydraulic pumps by Oilgear deliver the punch that is required for large, heavy-duty systems. Utilizing advanced engineering, the PVV pump line now delivers up to 560 horsepower - four times the horsepower at approximately one-third the cost of previous models. Computer-optimized for maximum performance, PVV is compact in design and available in three displacements.
PVV pumps offer a large selection of controls that are readily interchangeable. With improved high-response controls and reduced noise levels, the rugged cylinder design of the PVV pump enhances optimal performance. The patented design of its pressure lubricated swashblock offers high performance for high-cycling operations, and contributes to the pump's ability to run on low-viscosity and other special fluids.
|
|
Mini hydraulic pumps model PAY
With compressed air driven motor 700 bar
These mini-pumps are driven by an air-powered motor and can be connected to any supply source of compressed air. These compact low-cost pumps can operate all single-acting or double-acting hydraulic cylinders up to a max. operating pressure of 700 bar.
Features
- Pedal in neutral position - motor stands still, cylinder stands, pressure is held.
- Pedal depressed - motor starts, cylinder advances, pressure is built-up.
- Pedal pushed forward - motor stands still, pressure is released, cylinder retracts.
|
|
|
External gear units are classic hydraulic units and come in the form of pumps and motors. Individual pumps, multiple pumps and lownoise SILENCE versions in seven different series open up a virtually unlimited range of possible uses.
|
|
Axial piston units are available in the form of pumps and motors in bent axis design or swashplate design for medium- and high-pressure ranges. They are the main components in the hydrostatic transmission. Compact size and high power density, economy and reliability are characteristic advantages which speak for the use of hydrostatic transmissions, together with the fact that they meet the demand for high speed and high torque, as well as optimum efficiency.
|
|
PUMP SIMPLE EFFECT HAS DOUBLE FLOW WITHOUT TANK
- Hand pump steel, compact, light, resistant.
Fixing ensured by 4 screws.
It is appropriate to supply the jacks simple effect including race and of important size.
- Important Flow for a better productivity. For a jack having a piston of Ø 50 mm = advances of 1 cm per blow of pump.
- The manual pump with two flows: automatically passes from the function advanced to the focntion work, it automatically passes from the function advanced to the focntion work.
- Equipped with a valve of limitation of pressure for safety in the event of overload.
- Decompression with wordwrap.
Characteristics:
- Pressure (in low pressure): 50 bar
- Pressure (in high pressure): 600 bar
- Flow by blow (in low pressure): 21 Cm3
- Flow by blow (in high pressure): 5 Cm3
|
|
WILO booster pumps are installed as boosters for water supply and circulating systems.
They provide enough water pressure for high buildings, elevated parts of cities and municipalities as well as in industrial applications.
Booster pumps can be installed vertically, up to a certain number of stages, also horizontally. In case of vertical installation the space requirement of the pumping installation is very low, in case of horizontal installation the complete pipework is laid at one level
|
|
PUMP SIMPLE EFFECT HAS DOUBLE FLOW WITHOUT TANK
- Hand pump steel, compact, light, resistant.
Fixing ensured by 4 screws.
It is appropriate to supply the jacks simple effect including race and of important size.
- Important Flow for a better productivity. For a jack having a piston of Ø 50 mm = advances of 1 cm per blow of pump.
- The manual pump with two flows: automatically passes from the function advanced to the focntion work, it automatically passes from the function advanced to the focntion work.
- Equipped with a valve of limitation of pressure for safety in the event of overload.
- Decompression with wordwrap.
Characteristics:
- Pressure (in low pressure): 50 bar
- Pressure (in high pressure): 600 bar
- Flow by blow (in low pressure): 21 Cm3
- Flow by blow (in high pressure): 5 Cm3
|
|
The pneumatically hydraulic high-pressure pumps of the series PMA are laid out for the promotion of liquids with pressure up to 2.400 bar, at a pneumatics printing of 7 bar. These high-pressure pumps become everywhere there
begun, where compressed air is available as energy source and where a high and/or highest hydraulic printing is needed for test or for test purposes and/or for other applications. With compression tests the systems which can be examined are filled, aired out with a suitable liquid (oil, emulsion, pure water) under low pressure and brought afterwards by the Madan PMA of high-pressure systems on the desired pressure. All pumps of the Madan PMA series are supplied in rustproof execution (high-grade steel material 1,4401). Thus long life span and maintenance-free operation are ensured.
|
|
|
|
|
|
PVK units are axial piston pumps of slipper design. Rotor of this pump is driven by shaft which is supported by 2 roller bearings. Inside of the rotor, there are moving 9, hydrostatically balanced, pistons parallel with an axis of rotation. They are slipping on the inclined thrust plate which is placed inside of the swash plate and this way, the pistons are moving with a straight-line motion.
They create 1 suction and 1 pressure stroke per revolution. Fluid direction is performed by frontal rotational distribution. Single cylinders are joined either with a suction channel or a pressure one of the end cap during a motion of the distributor. Swash plate angle is possible to regulate continuously with various ways of control and automatic regulations (mentioned in 5, 5.1 and 9.1) which are part of axial piston pump.
These units are designed for conversion of mechanical energy into pressure one. They can be used in closed loops of various machines (e.g. road, construction, grading, agricultural, forest, mining etc.) where is demanded a continuous change of input parameters. The loop has to be designed such way that pump parameters, which are determined by technical conditions and project of the specific application , must not be exceeded during an operation.
|
|
|
|