High-performance distributed I/O system
Gateway for GDNET network
Gateway for main field Busses
Entirely configurable via software
Completely remote from the field
Modular
Simple for cabling
Sturdy
|
|
Our modular SmartStack I/O expansion system allows the flexibility of using digital, analog and specialty I/O boards. You can choose from various I/O combinations and stack up to four different I/O boards onto a single OCS station, as well as our TIU200. This modular, quick stacking approach provides scalability and flexible design.
-Wide variety of I/O and Speciality Modules
-Massive Analogue range
-Compact and Stackable
-Communications Modules available
~ Cscape™: All Units are programmable with a Free Software ~
|
|
Option to network the Schlegel control units and pilot lights (control devices, operator consoles, panels...) to the most common Fieldbus systems (such as AS-Interface, CANopen, Profibus DP, ...).
The Fieldbus compatible Schlegel control units are particularly for applications using a large number of control units and pilot lights to be connected to the Fieldbus at less wiring effort.
|
|
The BradControl family of I/O modules provides a reliable solution for connecting industrial controllers communicating on industrial networks to I/O devices. Both in-cabinet and on-machine harsh environment applications are supported.
In-Cabinet:
The BradControl Block I/O system is an effective way to connect industrial I/O devices to a PLC or PC controller over Ethernet. The BradControl interface solution is comprised of a network adapter and up to 32 expansion modules mounted in an enclosure close to the field devices.
On-Machine:
BradControl I/O modules provide a reliable solution for connecting industrial controllers communicating on Ethernet to I/O devices in harsh environments. Rated for IP67 environments, BradControl I/O modules can be machine mounted and are able to withstand areas where liquids, dust or vibration may be present.
|
|
The BradControl family of I/O modules provides a reliable solution for connecting industrial controllers communicating on industrial networks to I/O devices. Both in-cabinet and on-machine harsh environment applications are supported.
In-Cabinet:
The BradControl Block I/O system is an effective way to connect industrial I/O devices to a PLC or PC controller over PROFIBUS. The BradControl interface solution is comprised of a network adapter and up to 32 expansion modules mounted in an enclosure close to the field devices.
On-Machine:
BradControl I/O modules provide a reliable solution for connecting industrial controllers communicating on PROFIBUS to I/O devices in harsh environments. Rated for IP67 environments, BradControl I/O modules can be machine mounted and are able to withstand areas where liquids, dust or vibration may be present.
|
|
Introduction
The ioLogik E4200 is suitable for remote monitoring and alarm systems, such as are used for water treatment systems, water supply systems, wastewater treatment systems, and power monitoring systems. These kinds of applications need more I/O points and a variety of I/O types, including temperature sensors, gas detectors, and water quality detectors, all of which can benefit from the versatile mixture of I/O features supported by the ioLogik E4200.
Features
• Supports up to 16 I/O modules
• Dual Ethernet LANs and one RS-232 port
• Front-end intelligence that supports 80 Click&Go rules
•Unicode Active Messaging with real-time stamp, including SMS, SNMP Trap with I/O status, TCP, email
• Built-in web console
• PC utility: Auto detection of installed modules
• Windows/WinCE VB/VC.NET and Linux C APIs
|
|
|
|
|
|
I/O Modules
The Serial Bus System is a completely integrated solution with an extremely fast I/O backplane that uses change-of-state (COS) connections to maximize performance
Power Type: Electro-Pneumatic
Modularity features allow easy module replacement with unique latching mechanisms and auto device replacement which allows OEMs to add I/O modules without making changes to the control software. A full set of I/O modules accept signals from sensors, photo eyes, limits and other field input devices as well as providing signals to remote solenoid valves and other output devices. There is a choice of digital, analog, and high-watt I/O modules, which include built-in short circuit and open circuit detection circuitry with electronic feedback. A single ROSS serial bus communication module supports up to a maximum of 63 I/O modules and up to 264 inputs and 264 outputs.
- Accepts signals from sensors, photo eyes, limits and other field input devices.
- Provides signals to remotely operating solenoid valves and other field operating output devices.
- Choice of digital, analog, high watt I/O Modules.
- Choice of connectors: 8mm, 12mm or M23.
|
|
ARF20 / ARF30 - Logical and analogical status transfer 433/434MHz or 869MHz – 10 & 500mW LICENCE-FREE
* Monodirectional transmission of 8 logical status or 4 analogical values up to 4km
* 8 TOR inputs toward 8 "open collector" outputs or 4 relays
* 4 channels/8 bits – voltages 0/5V or currents 0/20mA
* Complies with the European standard RTTE EN300-220 / EN301-489
* IP65 box ready for use
* Industrial applications, long range transmissions and/or in disturbed environments
(in-town network, agriculture, difficult environments, building interconnection…)
o Information transfer
o Wireless remote control
o Alarm and security system triggering
o Level control…
|
|
Zlinx Wireless I/O, point-to-point/multi-point
How to select the right wireless system for your Modbus point-to-point/multi-point applications
Simplify your installation by sending your digital and analog inputs and outputs over the air. Why run a wire when you can install a Zlinx wireless module to replace it? The new Zlinx wireless product line provides point-to-point or multi-point communication, replacing your wires.
With bi-directional flow control, the controllers allow full-duplex transmissions to optimize the communiation efficiency. Modbus Mode - Up to 150 base modules in a system. Up to 6 systems can run simultaneously by using difference RF network I/O.
Connects directly to analog, digital and temperature inputs and outputs
Point to point/multi-point wire replecement
Expandable, modular design
Modbus compatible
|
|
|
|
|
|
|
The TempTrackr™ Multipoint System provides a batteryless, non-invasive and low cost temperature measurement solution that is ideally suited for applications ranging from High Power Switches to Rotating Machine Components. The Starter Kit is designed to showcase the capabilities of the TempTrackr™ Multipoint System. Each Kit includes three batteryless wireless temperature sensors that are capable of reading temperatures between 0°C and 120°C. The three sensors provide the ability to monitor temperature at multiple points of interest. The Surface Acoustic Wave (SAW) resonator within each sensor is powered by bursts of electromagnetic radiation emitted by a wireless reader (also known as a wireless interrogation unit). A feedback signal, conditioned by the temperature to which the resonator is exposed, is then electromagnetically transmitted to the wireless reader where it is processed for temperature measurement. The TempTrackr™ Multipoint System is capable of tracking up to six sensors and can provide temperature data via the CAN communication protocol. The number of sensors can be extended to 12 by making use of multiple interrogation antennae. The Starter Kit is an ideal technology evaluation tool3. SenGenuity will work closely with you to adapt the TempTrackr™ Multipoint System to meet the specific needs and requirements of your application.
|
|
|
|
|
|
Analog input modules AI20x/SI
* Number of inputs: 2 / 4
* Input current: 0 .. 20 mA
* Differential inputs
* Resolution: 16 bits
* Inputs synchronizable
* Galvanic isolation from system: 500 V
* Galvanic isolation of channels: 500 V
Analog Input modules AI204/x
* Number of inputs: 1 / 2 / 4
* Input voltage: ±10 VDC
* Differential inputs
* Resolution: 16 bits
* Inputs synchronizable
* Galvanic isolation from system: 500 V
* Galvanic isolation of groups: 500 V
Analog Output module AO202
* Number of outputs: 2
* Output voltages: ±10 VDC
* Differential and short circuit proof outputs
* Resolution: 16 bits
* Outputs synchronizable
* Galvanic isolation from system: 500 V
* Galvanic isolation of channels: 500 V
Analog Output module AO208/I
* Number of outputs: 8
* Output current: 0 .. 20 mA or 4 .. 20 mA
* Resolution: 13 bits
* Galvanic isolation of channels: 500 V
* Galvanic isolation of groups: 500 V
Analog In/Output modules AIO288/x
* Number of inputs: 8 (±10 VDC / ±1 VDC or 0 .. 20 mA)
* Number of outputs: 8 (±10 VDC)
* Resolution: 14 bits
* Connection: single-ended or differential
* Number of Pt100 sensors: 4
* Connection: 2- or 4-wire technology
* Optional galvanic isolation: 500 V
|
|
VXI Technology is one of the leading suppliers worldwide of modular test solutions, offering a broad selection of instruments capable of meeting widely varying customer needs and applications. We develop high-performance instrumentation with a focus on density, modularity and price/performance.
All of our products come with industry standard drivers. These include driver source code and executable soft front panels for interactive control with the instruments.
VXI Technology provides the following types of instruments:
1. Single function, single-slot VXIbus modules
2. Multi-function instruments based on our VMIP platform
3. VMEbus instrumentation
|
|
|
|
|
|
Digital Input modules DI2xx
* Number of inputs: 12 / 16 / 32
* Input voltage: nom. 24 VDC / nom. 48 VDC
* Separate single group
* Interrupt inputs: max. 2
* Sink/source inputs
* Galvanic isolation
* Status indicating LED for each channel
Digital Output modules DO2xx
* Number of outputs: 16 / 32
* Output voltage: nom. 24 VDC / nom. 48 VDC
* Output current: depends on type 2.5 / 1 / 0.5 A
* Total current depends on type: 8 / 16 A
* Galvanic isolation
* Status indicating LED for each channel
Digital relay output module DOR206/xxx
* 6 relays
* normally open contact (NO), normally closed contact (NC), change-over contact (CO)
* Standard socket for SIL relays
* Electromechanic or solid state relays
* Mechanically locked relays
* Coil voltage monitoring
* LED status display for every channel
* Galvanically isolation designed for system to channel 2500 V AC
Digital In/Output modules DIO2xx
* Total channel number: 16 / 32 / 48 / 64 / 80, nom. 24 VDC
* Number configurable inputs/outputs: 16
* Number of inputs: 8 / 16 / 32
* Number of outputs: 8 / 16 / 32
* Total current depends on type: max. 8 / 12 / 16 / 20 / 24 A
* Configurable interrupt inputs
* Status indicating LED for each channel
Digital In/Output module TTL264
* Number of inputs: 48
* Number of outputs: 16
* Number sink / source outputs: 8
* Number sink outputs: 8
* TTL level: nom. 5 VDC
* Galvanic isolation
|
|
I/O-Module von Baumüller
Up to 64 I/O terminals can be operated directly at an I/O node. This means that up to 1020 I/O signals can be processed on site. This reduces the cost of wiring a machine or system.
Up to 64 I/O terminals can be operated directly at an I/O node.
Baumüller I/O components provide users with a wide range of modules for adapting to requirements in the best possible way. Industrially compatible signal types can be easily incorporated in the application for evaluation purposes.
The use of I/O islands means that the machine information can be recorded at their “origin”, transmitted to the PLC and processed.
|
|
|
The Trio CAN16 I/O module offers a compact DIN rail mounted I/O expansion capability for all Trio Motion Coordinator controllers. Up to 16 modules may be connected to the CAN link which may be up to 100m long. This provides 256 bi-directional channels of distributed I/O at 24Vdc level. All points are short-circuit proof and competely isolated from the CANbus. The Trio CANbus I/O expansion can considerably reduce machine wiring.
|
|
|
WAGO-SPEEDWAY 767 the new performance class for automation without control cabinets. Bus linking will be implemented by means of fieldbus couplers and programmable fieldbus couplers for PROFIBUS DP, EtherNet and CANopen, including PROFINET and DeviceNet fieldbus couplers. The modules already come equipped with eight digital inputs. Input and output modules complement the couplers. All of the digital modules are equipped with eight channels, with M8 or M12 connections available. The product program also includes two input modules and four output modules for rated currents of 0.5 and 2 A.
|
|
Typical Distributed I/O and Remote I/O Applications
Distributed I/O and Remote I/O eliminate expensive point-to-point wires by networking just a few, or thousands of, process signals onto one digital communication link.
For data acquisition, distributed I/O and remote I/O send signals from field-mounted sensors, transmitters, transducers, and alarms directly to DCS, PLC, and PC-based systems.
Send control signals long distances to remote valves, pumps, and motors with distributed I/O and remote I/O.
Unburden an overworked computer system by distributing signal conditioning and intelligence.
Use as expansion I/O to add points to a DCS or PLC system.
Convert weak sensor signals to immune digital signals to avoid damage during long-distance transmission through a noisy plant.
Distributed I/O and Remote I/O allow the transmission of signals any distance and over any terrain with twisted-pair wires, fiber optics, radio link, or modems.
|
|
On-Machine control is the placement of automation components directly on a machine rather than housing them in a remote, central cabinet. This is possible with the emergence of more modular, compact devices, plug-and-play connectivity, flexible communication networks, intelligent devices, and a wide array of products with improved environmental ratings. On-Machine components can include everything from programmable controllers, motor starters, drives, sensors, contactors, network media, distribution boxes, and I/O, as well as HMI devices. On-Machine solutions provide reduced wiring and system costs, improved Mean Time to Repair (MTTR), enhanced control system reliability, increased productivity, and greater flexibility.
|
|
APPLICATIONS :
Inputs/Outputs management over Ethernet. Functions : alarms, counters, and so on.
MANAGEMENT
Configuration and management over RS232 and Ethernet interfaces - TCP/IP.
PROTOCOLS :
- HTTP
- TCP/UDP
- SNMP
- ALARMS
- SNMPtraps
- TCP/UDP
- SMTP (Email)
The alarm conditions can be configured on inputs or counters states.
|
|
User can select
32 Input / Output / Latch function per each I/O point
(photocoupler isolation)
Remote I/O by Ethernet Interface
Reducing the wiring of FA machines
|
|
MAXIFLEX is a versatile and powerful telemetry and remote I/O system suitable for a wide range of applications from RTU Outstations to Remote I/O on your DCS or SCADA software.
Ease of use and powerful communications capability are the hall-mark of this range.
It is true that plant communications technology has advanced dramatically in the last decade. The range of instrumentation capable of being networked grows daily.
|
|
|
|
|
|
S900 provides all input and output modules needed for intrinsically safe field signal connection. The field signals are amplified in every S900 functional module, electrically isolated, and then output via an internal serial bus. A communication interface converts the digitized signals to adapt them to the standardized PROFIBUS DPV1 fieldbus protocol. Supervisory process control systems, DCS or SCADA systems use an intrinsically safe fieldbus to communicate with the communication interface.
A single fieldbus network suffices for configuring the individual fieldbus nodes, for cyclic data exchange, for all acyclic services, and for communication with HART®-compatible field instruments. All functional modules can be replaced easily and quickly in the installation or maintenance phase. The functional modules and the - optionally redundant - communication interfaces of systems placed in Zone 1 can be removed and plugged in while operation is running, without affecting the communication of the remaining modules. Only the primary power for the plug-in type power supply modules requires increased safety EEx-e.
Integrated encapsulated switch-off mechanisms allow for hotswapping, i.e. the power supply units can be replaced without interrupting the primary power. Due to its little space requirements and robust design and its environmentally ruggedized case, the I/O system S900 is the best, cost-saving solution for use on site, in hazardous Zone 1 or Zone 2 areas.
|
|
Description
This module allows the connection of 16 digital signals to the PROFIBUS-DP, according to DIN EN 61158-2...6; DIN EN 61784-1, within the hazardous area. Signals from flameproof encapsulated limit switches and control devices can be injected directly.
In case of NAMUR sensors or other signalling contacts that are controlled in an intrinsically safe way, barriers or isolator amplifiers are connected on line side. LEDs on the front of the module output the input states as well as important status messages.
|
|
Description
This module allows the connection of 16 digital signals to the PROFIBUS-DP, according to DIN EN 61158-2...6; DIN EN 61784-1, within the hazardous area. Signals from flameproof encapsulated limit switches and control devices can be injected directly.
In case of NAMUR sensors or other signalling contacts that are controlled in an intrinsically safe way, barriers or isolator amplifiers are connected on line side. LEDs on the front of the module output the input states as well as important status messages.
|
|
|
Foundation Fieldbus H1 level has been designed as a digital replacement of the 4 to 20mA standard in the process industries. Foundation Fieldbus is also a LAN (Local Area Network) for instruments used in both process and manufacturing automation with built-in capability to distribute the control application across the network. The physical wiring is also fully compatible with intrinsic safety (IS) or nonincendive wiring standards and may be used in hazardous, as well as general purpose areas. In hazardous areas standard explosion-proofing or power limited concepts may be used, as well as IS concepts, offering greater cabling design flexibility.
|
|
|
Open, smart and seamless. Omron offers open networks such as DeviceNet and PROFIBUS-DP that allow easy integration in existing installations and ensure compatibility with third party systems. We also offer Compobus/S, Omron proprietary sensor/actuator bus, for cost efficient, fast and program-less configuration.
|
|
|
The solution Interface-HAVE is an alternative to the parallel beams of cables. It is the only system which can transfer the data and energy by means of one only cable with 2 drivers coded with protection against the inversion from polarity. The connection of the detectors and the actuateurs is carried out by the technique of perforation of the insulation.
|
|
The increasing level of automation in machines and systems and the consequent rise in the number of I/O devices have in turn increased the amount of wiring required. Decentralised I/O systems bring order to this chaos. Lenze offers two product concepts with IP 20 degree of protection which are suited to both simpler digital applications and more complex automation tasks.
Compact system
The compact version is available in 8, 16 and 32-channel modules with up to 24 inputs and 8 outputs, using single or three-wire technology.
more >>
Modular system
The modular version consists of three components: a gateway, electronic modules and a backplane bus. Up to 32 elements can be combined as desired.
|
|
|
The WAGO-I/O-SYSTEM 753 PROFIsafe modules are binary inputs and outputs as per IEC 61508 for the application on the PROFIBUS with PROFIsafe and can be utilized without major modifications to the existing system of Series 753.
|
|
|
|