- Electricity - Electronics >
- Cable, Connector, Enclosure >
- IEC electrical cable
IEC electrical cables
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Nominal voltage: 2,000, 1,500 V
Temperature: 120, 90 °C
Halogen free cross-linked polyolefin photovoltaic cable for the use within PV systems. UL und IEC rated cable for system voltage up to DC 1500 V.
Nominal voltage: 2, 2, 1,500, 1,800, 7 kV
Temperature: -40 °C - 120 °C
Halogen free cross-linked polyolefin photovoltaic cable for the use within PV systems. IEC rated cable for system voltage up to DC 1500 V.
Nominal voltage: 1 kV
Temperature: -40 °C - 90 °C
Cold and oil-resistant cables for flexible applications under torsional load, halogen-free - 0.6/1 kV ÖLFLEX® TORSION FRNC: UL: cRUus AWM (II A/B) OIL RES I+II, power + control cable 0.6/1 kV, wind turbine ...
Nominal voltage: 300 V - 1,000 V
Temperature: -55 °C - 145 °C
Cross-section: 1, 1.5 mm²
Electron beam cross-linked cables for more demanding application requirements ÖLFLEX® HEAT 125 C MC - halogen free power and control cable with DNV GL certificate, special fire performance, IEC ...
Temperature: -40 °C - 85 °C
Length: 20 m - 500 m
A cable as an antenna: radiating cable for the industry Cranes, elevators or rail-guided vehicles such as overhead monorails: IWLAN RCoax radiating cables enable a reliable radio connection, ...
Temperature: -40 °C - 75 °C
Length: 100 m
... four-wire, industrial PROFINET cabling on the factory floor with special FastConnect cable structure for quick assembly on FC RJ45 and FC M12 plugs. The FastConnect stripping tool enables particularly ...
Preassembled and production-tested installation cables with RJ45 or M12 connection in various lengths from 0.3 m to 50 m. For direct mounting on devices and laying on cable racks with RJ45 or M12 interface ...
... SPE cable products, BizLink offers a solution which is standardized according to IEC 61156-x for trailing, torsion and robotic applications as well as special solutions that combine Single Pair Ethernet ...
... FieldLink cable solutions, which, thanks to their robustness, can be deployed in a variety of industrial environments. The Ethernet bus cable range from Cat 5e up to cat 7 is available with twisted ...
... insulation material which makes our cables highly abrasion and media resistant, always keeping their high flexibility. Moreover, we offer an extensive range of cables for fixed applications. We offer ...
Nominal voltage: 600 V - 1,000 V
Temperature: -20 °C - 80 °C
Lapp Muller
Nominal voltage: 600 V - 1,000 V
Temperature: -25 °C - 80 °C
Lapp Muller
Nominal voltage: 600 V - 1,000 V
Temperature: -25 °C - 80 °C
Lapp Muller
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 185 mm²
... for selected torsion applications conditionally suitable for drag chains versatile use in many industries, particularly in machine and plant construction PVC control and connection cable in alignment ...
HELUKABEL
Nominal voltage: 500, 300 V
Temperature: -50 °C - 90 °C
Cross-section: 0.75 mm² - 16 mm²
... D-VIERSEN · SABIX® A 260 PUR 12 x 1,5 mm² CE SABIX® A 260 PUR is a cold resistant, flexible control cable with numbered cores. This oil resistant cable is weather resistant and is recommended for use ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 2,000, 300, 500 V
Temperature: -50 °C - 90 °C
Cross-section: 0.5 mm² - 240 mm²
... control cable with numbered cores for continuous movement Marking for S 200 07741215: SAB BRÖCKSKES · D-VIERSEN · S 200 12 x 1,5 mm² CE High flex cable with numbered cores for continuous movement ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 2,000, 600, 300, 500 V
Temperature: -50 °C - 90 °C
Cross-section: 0.5 mm² - 50 mm²
... PUR control cable with numbered cores Marking for S 980 P 77741807: SAB BRÖCKSKES · D-VIERSEN · 77741812 S 980 P 12 x 0,50 mm² 20 AWG/12c 77742012 UL AWM Style 21060 80°C 600V CSA AWM I/II A/B 80°C 600V FT1 FT2 CE Flexible ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 90 V
Temperature: -25 °C - 80 °C
... /Control Cables in AWG 22, shielded, zero halogen, flame retardant, with small outer jacket. High flexible stranded copper conductor, closed twisted pairs. NET Price per 1m - Cu included UL-approved PUR-Data Transmission- ...
Nominal voltage: 300 V
Temperature: -30 °C - 105 °C
Cross-section: 0.09 mm²
Flat Ribbon Cable in AWG 28 with spacing 1,27mm, gray with red stripe
Nominal voltage: 300 V
Temperature: -30 °C - 105 °C
Cross-section: 0.09 mm²
Flat Ribbon Cable in AWG 28 spacing 1,27mm, multicolored, color sequence by IEC
Temperature: -10 °C - 105 °C
Cross-section: 0.44, 0.75, 0.22 mm²
PVC inner and outer providesa good general-purpose cableideal for extension leads. PVC is waterproof and is self-extinguishing, it has a high dielectric strength, good mechanical properties and provides resistance to chemicals, oil, hydrocarbons ...
The SS321 by Temperature Technology Ltd. is a mineral insulated and metal sheathed RTD cable. The unit is available with copper or nickel conductors. It is made out of stainless steel materials SS316 or SS321 sheath. ...
... of the cable jacket: blue • coupling attenuation greater than or equal to 85 dB • electrical data tested up to 1500 MHz • GHMT Cat.7A PVP certified • applicable standards: EN 50173-1, ISO/IEC ...
METZ CONNECT
Temperature: -20 °C - 60 °C
Length: 500, 1,000 m
... • color of the cable jacket: blue • coupling attenuation: 80 dB • applicable standards: EN 50173-1, ISO/IEC 11801, EN 50288-4-1 and IEC 61156-5 • cable jacket: ...
METZ CONNECT
Temperature: -20 °C - 60 °C
Length: 305, 500, 1,000 m
... 40 dB • applicable standards: EN 50173-1, ISO/IEC 11801, EN 50288-6-1, IEC 61156-5, ANSI/TIA-568.2-D • cable jacket: LSHF (LSOH) • flame-retardant to IEC 60332-1, ...
METZ CONNECT
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 50 mm²
power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in ...
CAE GROUPE
Nominal voltage: 300 V - 500 V
Temperature: -40 °C - 80 °C
power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in dry, ...
CAE GROUPE
Nominal voltage: 3,000 V
Temperature: -40 °C - 80 °C
power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in dry, ...
CAE GROUPE
Nominal voltage: 450, 600, 750 V
Temperature: 80 °C - 105 °C
Nominal voltage: 600 V
Temperature: 70, 105 °C
Cross-section: 2.11 mm² - 116 mm²
This flexible robot wire uses an ultra-thin conductor. With CE(TUV), UL, and PSE certifications,this cable is highly evaluated for its excellent workability and exceptional flexibility. Electric wire ...
Nominal voltage: 750, 500, 450, 300 V
Temperature: -12 °C - 80 °C
Cross-section: 0.75 mm² - 50 mm²
Carpel flat cable for moving equipment comes in a variety of N° conductors ranging from 6 to 24. The cores are identified according to CEI-UNEL 00722 tables and generally progressive numbering is used, with or without ...
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm²
... conveyor technology, heating and climate technology In dry, damp and wet rooms As a monitoring, measurement and control cable for industrial applications For flexible applications without compulsory guide PVC Flame-retardant, ...
LÜTZE
Nominal voltage: 500, 300 V
Temperature: -40 °C - 80 °C
Cross-section: 0.75 mm²
... conveyor technology, heating and climate technology In dry, damp and wet rooms As a monitoring, measurement and control cable for industrial applications For flexible applications without compulsory guide PVC Flame-retardant, ...
LÜTZE
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 1 mm²
... conveyor technology, heating and climate technology In dry, damp and wet rooms As a monitoring, measurement and control cable for industrial applications For flexible applications without compulsory guide PVC Flame-retardant, ...
LÜTZE
Temperature: 70 °C
Cross-section: 1 mm² - 2.5 mm²
Length: 500 m - 1,000 m
... PVC or brown SH jacket + marking + metric Fire resistance NFC 32070.2.1 (flame retardant) and IEC 60332-1 Euroclass B2ca-s1a, d2, a1 (ZPAU - SH cables) Operating temperature: 70°C Resistant to mineral ...
Temperature: 70 °C
Cross-section: 1 mm²
LGV (High-Speed Lines) Intercity railways - Main signal cables High performance protection against parasitic induction of the catenary and disturbances caused by TGV (High-Speed Trains) Links the central control ...
Temperature: -40 °C - 90 °C
SOLAR cable means flexible single cables specialty designed for wiring solar plants. SOLAR cables arc extremely robust and resist high mechanical load and abrasion. High temperature ...
... Installation chord for inner area • Electrical Values Cat.7 (ISO/IEC) class F • Norms ISO/IEC 11801 / EN 50173 • Reaction to Fire halogen free and flame-retardant acc. to IEC ...
Aixontec
Temperature: -30 °C - 105 °C
... in industry and very high heat • Electrical values Cat.5e, class D 200MHz / 10GbE • Norms ○ ISO/IEC 11801 (2nd ed.) ○ EN 50173 • Cable construction ○ 1. Conductor ...
Aixontec
Temperature: -25 °C - 70 °C
Cross-section: 16 mm²
... Reaction to fire acc. to: ○ EN 60332-1-2 Eca ○ IEC 60332-1-2 ○ NBN C30-004 F1 • UV-resistant • Insulation thickness 1,0 mm • Outer Diameter 7,5 mm • M4 ring cable lug ...
Aixontec
Temperature: -10 °C - 105 °C
... bare copper drain wire Twisted cores & screened construction for reduced electrical noise Conductors PVC insulated and twisted together, aluminium Mylar® tape screen & drain wire, overall PVC ...
Labfacility Limited
Temperature: -75 °C - 260 °C
... offer a PFA Insulated Twin Twisted Thermocouple Cables, PFA Insulated Flat Pair Thermocouple Cables, PTFE Insulated Twin Twisted Pair Thermocouple Cables, and PTFE Insulated Flat Pair ...
Labfacility Limited
Temperature: -75 °C - 260 °C
Single pair PFA insulated cable / wire Laid flat, side by side & PFA sheathed 1/0.315 or 7/0.2mm Conductors Tolerance class 1 Insulation rating -75 to 260°C IEC584 colour coded
Labfacility Limited
... machine cable or manual welding cable, but also as a generator and the connection between the welding cable. Its flexibility and high mechanical strength make it suitable for the automotive ...
... machine cable or manual welding cable, but also as a generator and the connection between the welding cable. Its flexibility and high mechanical strength make it suitable for the automotive ...
... machine cable or manual welding cable, but also as a generator and the connection between the welding cable. Its flexibility and high mechanical strength make it suitable for the automotive ...
Nominal voltage: 800 V
Temperature: -30 °C - 70 °C
... or signal transmission. DIN VDE 0815 ; directive 2014/35/EU RoHS 2011/65/EU EN 50575 ; EN 60332-1-2 ; EN 60332-3 ; IEC 60754-2 EN 61034-2 ; EN 50399 ; EN 13501-6 class B2ca-s1 d1 a1 min. bending radius installed ...
VOKA
Length: 1.5 m
Antenna coaxial cable Geti 1.5m with double shielding. Technical parameters: - straight IEC plug - angled IEC socket - color: white
Length: 10 m
Antenna coaxial cable Geti 10m with double shielding. Technical parameters: - straight IEC plug - angled IEC socket - color: white
Cross-section: 16 mm² - 120 mm²
... Wiring of concentric layers. So, the difference compared to copper cables is the fact that the latter is very flexible. The Earth cable is indeed a rigid cable. Earth cables ...
Temperature: -30 °C - 60 °C
... CN206672675U) passed 6 pack 1 external interference test. ISO/IEC 11801-1、ISO/IEC 11801-2、IEC 61156-5、 EN 50173-1、EN 50173-2、EN 50288-3-1、 ANSI/TIA-568.2-D、IEC 60332-1-2、IEC ...
Zhaolong Interconnect
Temperature: 105, 125, 150, 180, 200 °C
... according to IEC 61851 for 1-phase and 3-phase charging Charging cables according to NEC Art. 400 and UL/cUL category FFSO (UL62) as well as CSA C22.2 No.49 for 1-phase charging Charging cables ...
LEONI AG
Nominal voltage: 1 kV
Temperature: 20 °C
Cross-section: 10 mm² - 630 mm²
... rigid with a large radius. IEC 60228 Conductors IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) ...
Henan Tong-Da Cable Company
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining