| The B&K Precision Model 889A Synthesized In-Circuit LCR/ESR Meter is a high accuracy test instrument used for measuring inductors, capacitors and resistors with a basic accuracy of 0.2%. Also, with the built-in functions of DC/AC Voltage measurements and Diode/Audible Continuity checks, the Model 889 can not only help engineers and students to understand the characteristic of electronics components but also being an essential tool on any service bench. |
|
Measuring Instrument - LCR Precision Instruments ( LCR200) :
Key Features:
- Measurement Parameters : Z , Ls , Lp , Cs , Cp ,
DCR , ESR , D , Q , and (Theta)
- Test conditions : 100MHz , 120Hz , 1KHz , 10KHz , 100KHz , 200KHz ; 1Vrms , 250mVrms , 50mVrms , 1Vdc(DCR only)
- DMM Functionalities
- Dual LCD Display with LED backlit
- Open / Short calibration
- Remote binning capability
- Auto range / range hold selection |
|
| Agilent LCR and resistance meters are useful in testing components and materials in a variety of research and design applications and in component manufacturing. LCR meters measure impedance (inductance, capacitance, and resistance) at spot frequencies. Resistance meters are optimized for high-resistance or low-resistance measurements. |
|
Product ID: LCR-612
20000 Counts Hand Held LCR Meter Dual Display Auto-Ranging ( LCR-612 )
20000 Counts LCR Meter
Dual Display Auto-Ranging
MODEL: LCR-612
Outstanding Features:
1.Basic accuracy:
0.5% for Resistance
0.7% for Inductance, Capacitance
2.Dual Displays provide quick tested results readouts, with L.C.R. Display values up to 19999 counts and Q.D.R. display values up to 9999 counts
3.Excellent resolutions:
Resistance up to 0.001Ù
Inductance Capacitance up to 0.1uH/0.1pF
4.Provided up to 4 testing parameters:
Ls+(Q,D,Rs), Lp+(Q,D,Rp)
Cs+(Q,D,Rs), Cp+(Q,D,Rp)
5. Auto-Power Off function:
To conserve battery life for longer use.
6.Fuse detection function:
To inform that the fuse is open or damaged.
7.External DC Adapter functions:
Use of a DC adapter can also serve to disable Auto Power Off function.
Dual Display LCR Meter LCR-612 Test Ranges: 120Hz and 1KH
LCR-612 SPECIFICATIONS
LCR-612 Display:
LCR—4 1/2 digits, maximum reading of 19999.
QDR—4 digits, maximum reading of 9999. (Auto range).
Parameter Measurement:
Ls+(Q,D,Rs), Lp+(Q,D,Rp)
Cs+(Q,D,Rs), Cp+(Q,D,Rp)
Overload: "OL" is display.
Test Frequency: 1KHz and 120Hz.
Range Mode: Auto and Manual.
Auto Power Off:
The meter key switch inactive for more than 5 minutes, press power key to resume operation.
Measurement rate: Approx. 1 time per second, nominal.
Power Requirement: (1). Single standard 9-volt battery.
(NEDA 1604, IEC 6F22 006P) ;(2). External DC Adapter 12Vmim to 15Vmax / 50mA.(optional)
Overload Protection: 0.1A/250V fast below fuse.
Dimensions:192mm(H) x 91mm(W) x 52.5mm(D).
Weight: 365g. (including accessories) |
|
| The LCR Meter measure passive components with as little as 0.05 % error. These easy-to-use instruments are quick to setup, adjust and calibrate. The SR715 and SR720 are ideal for applications such as incoming inspection, quality control, automated test, and general benchtop use. |
|
- LCD Display 128 x 64
- File Management ( Flash Memory Card)
- Test Point Range : 64-2048
- Test Voltage : 50-1500VDC (RT-9651 H / CH )
- Insulation Test : 500K-1000MOhm(RT- 9651H/ CH)
- 4-Wire Rsistance Test : Yes
- Components Test : Resistor,Diode,Capacitor(Option)
- Resistor Measurement : 0.1Ohm-20MOhm
- Capacitor Measurement : 100pF-1000uF
- High Quality Relay |
|
1. 320x240 dot-matrix display
2. Test frequency range : 20Hz - 1 MHz
3. Measurement parameter |Z|, Rs, Rp,Xs, Rdc|, |Y|, Gp,
Bp, Ls, Lp, Cs, Cp, D, Q , Theta
4. Basic Accuracy ± 0.1%
5. Measurement Time : 30 mS ( Fast )
6. Bin Function : 8 bins (expandable to 15 bins)
7. Comparator function: Primary / Secondary
8. Memory : 256 instrument setups
9. External Memory interface (Option)
10. Interface : Handler,( Option : GPIB, RS232 ,Printer )
11. Deviation Zero : Open / Short
12. DC Bias (Option) |
|
| ... products without technical information |
| |
PM100-G - Fiber Optic Power Meter
Simple optical power and loss measurement
PM100-S - Fiber Optic Power Meter
Simple optical power and loss measurement
PM200 - Fiber Optic Power Meter
Link certification and reporting tool
FO600 - FiberMeter Optical Power Meter
FO610 - High Power FiberMeter Optical Power Meter
Ideal for testing and certifying in both Multimode and Single Mode applications
|
|
| Luna Technologies' Optical Backscatter Reflectometer (OBR) delivers unprecedented inspection and diagnostic capabilities for the fiber-optics industry. Luna's state-of-the-art OBR provides isolation of faults and problems well before final test, saving hours in rework and hard dollars in yield loss. |
|
| The OP510 was specifically designed for applications where cost effective solutions for measuring, monitoring and logging of insertion loss or power fluctuations are needed. The OP510 is a small (4"x2"x1.25") desk friendly module designed such that minimal movement and bending of the reference- and test cables is necessary. This results in stable, accurate and repeatable measurements. |
|
| Insertion loss (IL) and return loss (RL) on fiber optical components are measured fast and accurately with the OP930. The return loss is measured with the "no mandrel" method, meaning neither matching gel nor mandrel wraps are required at the far end of the cable. The insertion loss is measured by utilizing the stable transmitter of the return-loss as the source in combination with the precision optical power meter. |
|
| ... products without technical information |
| |
|
|