Agilent LCR and resistance meters are useful in testing components and materials in a variety of research and design applications and in component manufacturing. LCR meters measure impedance (inductance, capacitance, and resistance) at spot frequencies. Resistance meters are optimized for high-resistance or low-resistance measurements.
|
|
|
The B&K Precision Model 889A Synthesized In-Circuit LCR/ESR Meter is a high accuracy test instrument used for measuring inductors, capacitors and resistors with a basic accuracy of 0.2%. Also, with the built-in functions of DC/AC Voltage measurements and Diode/Audible Continuity checks, the Model 889 can not only help engineers and students to understand the characteristic of electronics components but also being an essential tool on any service bench.
|
|
Measuring Instrument - LCR Precision Instruments ( LCR200) :
Key Features:
- Measurement Parameters : Z , Ls , Lp , Cs , Cp ,
DCR , ESR , D , Q , and (Theta)
- Test conditions : 100MHz , 120Hz , 1KHz , 10KHz , 100KHz , 200KHz ; 1Vrms , 250mVrms , 50mVrms , 1Vdc(DCR only)
- DMM Functionalities
- Dual LCD Display with LED backlit
- Open / Short calibration
- Remote binning capability
- Auto range / range hold selection
|
|
Product ID: LCR-612
20000 Counts Hand Held LCR Meter Dual Display Auto-Ranging ( LCR-612 )
20000 Counts LCR Meter
Dual Display Auto-Ranging
MODEL: LCR-612
Outstanding Features:
1.Basic accuracy:
0.5% for Resistance
0.7% for Inductance, Capacitance
2.Dual Displays provide quick tested results readouts, with L.C.R. Display values up to 19999 counts and Q.D.R. display values up to 9999 counts
3.Excellent resolutions:
Resistance up to 0.001Ù
Inductance Capacitance up to 0.1uH/0.1pF
4.Provided up to 4 testing parameters:
Ls+(Q,D,Rs), Lp+(Q,D,Rp)
Cs+(Q,D,Rs), Cp+(Q,D,Rp)
5. Auto-Power Off function:
To conserve battery life for longer use.
6.Fuse detection function:
To inform that the fuse is open or damaged.
7.External DC Adapter functions:
Use of a DC adapter can also serve to disable Auto Power Off function.
Dual Display LCR Meter LCR-612 Test Ranges: 120Hz and 1KH
LCR-612 SPECIFICATIONS
LCR-612 Display:
LCR—4 1/2 digits, maximum reading of 19999.
QDR—4 digits, maximum reading of 9999. (Auto range).
Parameter Measurement:
Ls+(Q,D,Rs), Lp+(Q,D,Rp)
Cs+(Q,D,Rs), Cp+(Q,D,Rp)
Overload: "OL" is display.
Test Frequency: 1KHz and 120Hz.
Range Mode: Auto and Manual.
Auto Power Off:
The meter key switch inactive for more than 5 minutes, press power key to resume operation.
Measurement rate: Approx. 1 time per second, nominal.
Power Requirement: (1). Single standard 9-volt battery.
(NEDA 1604, IEC 6F22 006P) ;(2). External DC Adapter 12Vmim to 15Vmax / 50mA.(optional)
Overload Protection: 0.1A/250V fast below fuse.
Dimensions:192mm(H) x 91mm(W) x 52.5mm(D).
Weight: 365g. (including accessories)
|
|
|
The LCR Meter measure passive components with as little as 0.05 % error. These easy-to-use instruments are quick to setup, adjust and calibrate. The SR715 and SR720 are ideal for applications such as incoming inspection, quality control, automated test, and general benchtop use.
|
|
| ... products without technical information |
| |
Stop Time Measuring Instrument for safety measurements at power driven machines such as presses, shears and robots. The system is used to calculate the distance of the safety device. (2-hand control, light curtain ..)
Portable and solid equipment, built-in matrix printer
Free adjustable stop point
Standstill detection down to v < 1 mm/s
Measurement of maximum velocity
Measurement of velocity at stop point
ISO9000 calibration certificate
Traceability of measurement values
RS-232 interface for PC connection
Fast set-up time
Actuator to release no-touch safety equipment as option
|
|
The Stopping and Motion Analyser is designed to enable key Safety Critical machine parameters to be easily checked.
Smart has many valuable features for stopping time measurement:
- Calculates minimum allowed safety distance
- Easy to analyse stopping characteristics and movement
- Shows how the stop distance can be optimised
|
|
* USBscope50 is a tiny PC based oscilloscope which connects via the USB port, combining the ease of use, portability and economy of PC based scopes with high performance normally associated with much larger bench oscilloscopes.
* USBwave12 is a new concept in USB function generator products. PC based function generators offer many user benefits including flexibility, ease of use and economy.
The USB interface has developed into probably the best and most widely implemented PC peripheral connection method and is a natural choice for the function generator.
* USBpulse100 is a new concept in USB Digital Pulse/Clock Generator products. PC based pulse generators deliver many user benefits including flexibility, ease of use and economy. They are an invaluable tool during design and debug of digital circuits and can be used to quickly test the behaviour of a circuit under different input frequency and duty cycle conditions.
* USBcount50 is a PC based frequency counter designed for maximum flexibility, ease of use and economy. It is an invaluable tool during design and debug of digital circuits and can be used to quickly to verify generated frequencies, pulse widths and duty cycles.
|
|
| ... products without technical information |
| |
The MICRO III, with its small dimensions of only 4,7 x 8,8 x 2,5 cm, is the ideal gas detector for personal protection. The single gas detector with ATEX certification weighs only 75 g. It detects reliably oxygen, hydrogen or many toxic gases like hydrogen sulphide, ammonia, ozone, carbon monoxide, etc. The current gas concentration is shown on a large display. With a loud alarm of 95 dB and a changing frequency the small single gas detector is audible even in noisy environments. Simultaneously, two bright and alternately flashing LEDs indicate a gas alarm. Three alarm levels and the battery alarm provide comprehensive protection.
With a permanent operation of 24 hours a day a single AA battery powers this instrument for up to 9 months. The long-life smart sensors allow the change to other gases without any problems, since the detector recognizes the new sensor type. A high-performance pump (as per ATEX) for gas sampling can be easily attached, ensuring to detect gas hazards in confined areas.
Gases to be detected: O2, H2S, CO, NO, NH3, HCN, HCl, SO2, H2, C2H4O, SiH4, PH3, COCl2, NO2, Cl2, O3, ClO2.
|
|
|
These pumps with mechanically actuated dual diaphragms bring the advantages and security of the diaphragm design to applications with operating pressure up to 20 bar and flow rates up to 3.000 l/h at an economical price.
|
|
Advantages
Flexible
Optimal capacity adaptation to widely varying production processes
Variable stroke for each pump allows independent adjustment of each component
Variable speed drive allows flow rate variations while maintaining constant proportions
Economical
Automation allows higher production efficiency to be achieved
Adaptable
Existing installations can be altered or expanded with extra pumps or automatic control
|
|
| ... products without technical information |
| |
|
These pumps with mechanically actuated dual diaphragms bring the advantages and security of the diaphragm design to applications with operating pressure up to 20 bar and flow rates up to 3.000 l/h at an economical price.
|
|
Advantages
Flexible
Optimal capacity adaptation to widely varying production processes
Variable stroke for each pump allows independent adjustment of each component
Variable speed drive allows flow rate variations while maintaining constant proportions
Economical
Automation allows higher production efficiency to be achieved
Adaptable
Existing installations can be altered or expanded with extra pumps or automatic control
|
|
USB 1MS/s, 16-bit multifunction module with BNC inputs
- 1 MS/s 16-bit A/D converter
- 16 BNC differential analog inputs, with 7 programmable input ranges from ±100 mV to ±10 V full scale
- Over-sampling mode, including line-cycle rejection for low-level voltage measurements, even in the presence of AC power line noise
- 1 MS/s, 16-bit analog outputs
- 16 digital I/O
- 4 counter inputs capable of measuring frequency, period, pulse width, or quadrature encoders up to 20 MHz
- 2 timer outputs
|
|
DIRIS has been developed by Socomec over the last 10 years. It is a complete system for the operation of low and high voltage electrical networks and offers measurement and monitoring of electrical values, energy metering and management (electricity, water and gas), command and remote control of equipment and network protection.
3 highly-innovative products are being added to this range: the DIRIS A20, A40 and A41
Application:
All industrial or commercial LV/HV electrical installations
Original features and advantages:
The DIRIS A products meet all the requirements of installers and users:
- Easy to fit (compact casing, plug-in terminal blocks, a self test diagnostic menu to identify incorrect connection)
- Extremely accurate with high quality measurements using an ASIC component developed by Socomec
- Optimum readability with backlit, high-resolution LCD display
- Direct access to data via 4 or 6 keys
- Board can be upgraded with additional modules (communication, harmonics, alarms)
|
|
| ... products without technical information |
| |
| ... products without technical information |
| |
| ... products without technical information |
| |
HOLSTER BAGS
Practical in every detail.
Made-to-measure openings for easy access to controls, keypads or connectors.
Belt holsters can be rotated on the belt and can be removed quickly when required.
Ideal for small data entry devices. Also available in washable material.
|
|
| ... products without technical information |
| |
|