Easily view status of station alarms. Save engineering time and effort with simple wiring and configuration. Dip switch selection provides for either N/O or N/C input. View alarms even if there has been a power interruption. Alarms are sealed in until acknowledged. Substation and Plant Grade Equipment provides for secure operation in station environments. Wide temperature range (-40° to +85°C) and surge protection. Manned Station Annunciator - Output contact can drive alarm horn or external light. Super-bright LED output provides easily visible indication of alarm point in any ambient lighting condition. Unmanned Station Annunciator - Seal-in of momentary alarms provides a visual indication of event history.
|
|
| Configurable indicators for temperature, pressure, force, current and AC voltage, position, normalized inputs, with up to 4 alarm outputs, analog retransmission output, serial communication |
|
The LHL, LHI meets or exceeds factory Mutual (FM) Approval Standard temperature Limit switches Class 3545.
They are designed to automatically shut down a process when the measured value exceeds a pre-programmed value.
Alarm masking:
Puts the alarms in the stand by condition (mask) during instrument power up or professional masks a deviation or band alarm if the alarm condition is a
result of a set point change. In both situations the instrument maintains the alarm masking for the duration of the alarm condition.
Logic input:
These instruments are equipped with a logic input used to acknowledge an alarm condition by an external contact.
Maximum and/or minimum data hold:
The LHI is able to memorize the maximum and the minimum measured value. This function is automatically enabled at instrument power up
and it is always active.
Supplier of power supply failure indication:
These instruments are able to signal if a power failure occurs during normal instrument operation.
Power fail recovery settings are user configurable. |
|
The model 1390 indicator offers a field scalable professional display and dual, configurable professional alarms to meet your changing pressure indication requirements. The available optically isolated mA/VDC linear retransmission enables the user to log process trends, a valuable feature for SPC and SQC. A simple front professional panel instrument calibration and compact professional profile make the model 1390 the ideal indicator for your process.
|
|
| ... products without technical information |
| |
Low Volume Flowmeter and -switches
Variable Area Flowmeter and -switches
Paddle Type Flowmeter and -switches
Rotating Vane Flowmeter and -switches
Flow Measurement without Moving Parts
Flow indicator |
|
FEATURES:
- Control/Monitor/Alarm via GSM mobile phone, no distance limitation. User can control/monitor/alarm their devices all over the world.
- 8 channels Analog input (4 -20 mA)
- 8 Relay outputs
- 8 Switch inputs, normal open, close alarm
- 8 Analog inputs: system can preset 4 mA and 20 mA input value according the real measuring value and setting display unit. It can read actual measuring data via the SMS (Short Message) requested, such as CH1= 28.0 C. CH2=53.7 %RH, CH3=7.01 pH........CH8= 230.5 ACV.
- Enable or disable Analog input alarm (High alarm, Low alarm) via SMS.
- Enable or disable switch Input alarm (close alarm) via SMS.
- Set relay output On/Off via SMS
- Dot matrix LCD display show Analog input value, Switch input and Relay output status.
- All setting value will be saved into EPROM IC, no loss.
- Mobile telephone can call out all channel measuring value, status of Switch input and Relay output at any time.
- Can default two telephone no., alarm SMS can be sent to two users.
- Build GSM mobile modem (dual band).
- After the SMS command sent by mobile phone, the confirm message will be sent back to the mobile, safe and no loss.
- Intelligent application , innovation, wide range, no limitation |
|
SATELNODE X8SR is the basic VHF receiver of the SATEL local area transfer system. Together with SATELCODE alarm transmitter from SATEL, it provides the easiest way of setting up a wireless alarm transfer system.
The SATELNODE X8SR comprises of a high quality radio receiver with excellent selectivity and stability.
It is capable of processing coded messages from SATELCODE professional transmitter.
The SATELNODE X8SR is also equipped with an RS-232 interface, which provides a flexible means of programming the industrial radio modem with a PC, to meet the varying needs of applications.
By means of the SATELCODE / SATELNODE alarm transfer equipment, SATEL has drastically lowered the threshold of setting up a local alarm transfer system.
SATELCODE is a versatile VHF radio transmitter from SATEL's extensive selection of radio modems. Together with its counterpart, the SATELNODE receiver, it provides the easiest way of setting up a wireless alarm transfer connection between two points.
The SATELCODE transmits a message that includes both address and alarm information. The number of possible different messages amounts several tens of thousands.
The configuration of a SATELCODE / SATELNODE system is straightforward and the installation quick and easy. The user benefits from minimum time spent in planning and materialization fo an alarm system. The radio modems are extremely reliable. The operation costs of the alarm transfer system are low, as there are practically no network charges. |
|
The space-saving communication-solution for technical installations.
Modem / SMS Alarm-Messender
All “CombiLine” models became developed specially for industrial surroundings and they are corresponding to the most currently data-transmission-norms.
With the help of the included software package, the modules will be configured easily over the COMinterface.
8 alarm-signal-inputs, 2 switchable signal-outputs.
By activation the input lines, faults will be announced by sending an SMS message and displayed on a mobile phone, voltage breakdowns will be indicated as well.
While power interruption, the modules remain in operation by using an optional built-in NiMH accumulator. |
|
| ... products without technical information |
| |
SCADAlarm alarm and event-notification software provides a telecommunications link to industrial industrial automation software systems. Based on the Microsoft® Windows® operating system, SCADAlarm enables real-time intelligent alarm and event notification, professional data acquisition capabilities and professional remote control. SCADAlarm provides an open, easy to configure interface for constant monitoring and communication with processes regardless of location.
SCADAlarm software seamlessly integrates with the comprehensive FactorySuite A² product family and has built in browsers to enable fast configuration of information from Wonderware's Industrial Application Server and InTouch® HMI systems. Alarms can be vocalized over speakers, professional intercom systems, radios, multimedia speakers, PA systems and telephones. Users can listen to and acknowledge alarms, change set points, hear exact values of variables, and operate equipment via telephone from remote locations, saving valuable time and money. |
|
AlarmView is the industrial management software of alarms for the garrisoned technological systems and not, created and developed from Metoda Automation s.r.l fruit of the experience matured in the industries and of the background of industrial computing and electromechanical acquaintances of our specialistic technicians.
The integrated professional monitoring system AlarmView connects in seriale net (any is the used protocol of communication), machine intelligences carrying out the survey of the parameters through the interrogation of the tags. After all AlarmView di Metoda Automation represents a powerful and flexible instrument, or for the configuration of the interface man-machine or for the realization of logical of control, for the monitoring and the survey of all the alarm situations.
AlarmView is based on Microsoft systems and architecture client/server, and allows of:
· Monitorare in real time any situation of alarm on the single machine or the system;
· To increase the effectiveness of the participations of restoration reducing lessened you stop caused from the damages;
· Monitorare also garrisoned systems and not; productive plants, schools, hospitals, centers trade them, directional offices, etc.
· To now create "the historical" archives of the data (, date, unit, machine, operator, etc) on alarms.
AlarmView is made up of the following fundamental modules:
- Comunication Server (communication server): for the definition of the variable ones and the devices of reading;
- AlarmView Modulus: for visualization of the state of alarms;
- Management Control (optional): for the management of the Industrial beacons and the control of picture contactors. |
|
| ... products without technical information |
| |
Harwire system
The AuraSysTM P6 is an advanced, compact residential and light commercial, expandable hardwire intrusion alarm system.
With the AuraSysTM P6 system you will be able to control other systems and appliances such as garage doors, lights, heating, professional air conditioner and much more with the expandable PGM outputs.
The technology introduced in the AuraSysTM P6 Security System affords you reliability, security and protection. A simple user interface allows you to access powerful and advanced features without having to remember complicated codes.
AuraSysTM panels are compatible with Rosslare Security Product's MatrixBUSTM protocol products allowing it to operate seamlessly with a wide variety of compatible accessories and expansion products.
Wireless system
Inside the SP-06V, there is a fully integral supervising wireless receiver with an internal anti-vandal antenna, built-in microphone and speaker for clear 2-way voice listen in for alarm and personal alarms verification, 2400 bps modem digital dialer with advanced 2-CMS Telephone number full split reporting capability, which supports up to 6-PERSONAL Telephone numbers for sending pre-recorded voice messages users to private telephones. |
|
Box of indicators and alarms, from 1 to 3 stages.
Each stage comes in modules of 8 to 32 channels (96 channels in total).
Each channel can be in simple indicator mode or alarm mode (same functions as the J1900).
It is possible to group together different states of the same organ on the site:
- Start / Stop / "PUMP" alarm.
- Start / Stop / Defrost / "FRIDGE" alarm.
- "PROFESSIONAL BOILER" alarm.
Battery and charger included.
|
|
The alarm systems of the COMPALARM family are typified by their very reduced space, their high reliability and versatility for a wide range of applications, due to the great variety of available executions.
Furthermore, there is a practical malfunction absence, caused by external magnetic or electromagnetic interferences, due to the technical solutions given ( as professional filters and optoisolated input, etc.)
Message/alarm display series, provide an easy operator interface, substituting light indicators with clear pre-stored messages. |
|
| ... products without technical information |
| |
| ... products without technical information |
| |
| ... products without technical information |
| |
Accepting the signal from our speed switches and from a variety of industrial transmitters with a pulse or AC-output. The unit provides alternative input paths for high level and low amplitude. Performance data easy programmed locally at the unit by incorporated keys.
Incorporated 2 speed alarms with SPDT relay contacts. Response characteristics individually programmable: setpoints, response characteristics and starting conditions.
Optional one 20 ma analog output with programmable span.
Signal frequency range 0 – 100 kHz.
Supply from 18-40 v or 85-265 v AC or DC.
Main design for snap-on-track, optionally in IP65 outdoor or ATEX Ex-proof enclosure.
|
|
Fast response to the variable, with display, analog output, contact alarms, and data interface. 2 incorporated measuring channels, to compute their ratio, difference, percentage difference (draw and shrinkage in paper and textiles), monitoring speed synchronism. Programmable adaptation to the application data, of the analog span, and of the alarms performance. Optional data bus o RS 232 or PROFIBUS. Design optional for snap-on-track, or panel mount, or 19 inch rack.
Specific versions are available to handle speed and direction output from our corresponding sensors, actuating relays with programmable response characteristics.
|
|
H-TLC operates on the same basic principle as Torq-Tender, except the torque setting Is adjustable and it uses polymer materials in its major components to resist corrosion.
If ope | | |