LED strip indicator 584
The "semi-analog" LED strip indicator displays the measured value using 71 LEDs. This indicator is designed to withstand very stong vibrations yet has the familiar look of an analog indicator.
The two standard housing sizes and flexible inputs make the indicator a universal solution for all applications with increased vibrations.
Developed for large diesel engines, the indicator can be used directly on ships' engines (GL-approved models are available) and on any machine or system where high vibration resistance is required.
Ships' engines
Large engines
Pavement cutters
General road construction machinery
Turbines
Shredders
Rock crushers
Strainers
Features:
LED indicator (71 LEDs + 1 power ON)
1.5% accuracy
Display on 320° arc
Sturdy metal housing
Special design for strong vibrations
100mm or 96x96mm with changing scale
Inputs: Voltage input 0-10V
Current inputs: 0-20 / 4-20 mA
Frequency input: 0-10 Hz / 0-20kHz (PNP/NPN)
Sine wave input (e.g. for inductive sensors)
Fine tuning of +/- 10% possible
Options:
Acceptance from shipping certification agencies available on request.
|
|
The ATE300 is a multichannel indicator specially dedicated to flush-mounting (or wall-mounting) installations.
• Alternating display of 1 to 3 parameters
• 3 analogue inputs : 3 x 4-20mA or 3 x 0-10V
• 1 RS 232 digital input for KIMO external transmitter (class 200 & 300)
• 1 RS 485 digital input/output (Modbus protocol integrated)
• 22 pre-set units and 3 configurable units
• Configuration via software or remote control
• Electroluminescent front display, made of brushed stainless steel or white
lacquered
Join our distribution network all over the word....Contact us !
|
|
|
|
|
|
SCHMIDT® Air-Consumption Display Unit 20.031
8-digit panel meter for direct connection with the SCHMIDT® Flow Sensors SS 20.60 and SS 30.30x. It displays the air-consumption volume or the actual air-flow rate. The desired display mode may be selected via push button.
The sensor measurement signal will be converted into the respective numerical display via pre-selectable scaling factors depending on tube diameter. The sensor pulse output is directly connected to the panel meter. The analog output of the sensor remains free for further applications.
An electronic switched output of the panel meter is available for threshold detection of the flow rate as well as a pulse output for counting the consumption volume.
Applications
* Compressed-air consumption metering in production facilities
* Compressed-air consumption accounting per cost center
* Consumption monitoring of hydropneumatically driven machines
* Leakage detection in compressed-air systems
* Air-flow control in clean rooms and purification plants
* Air-massflow control of burners and combustion engines
|
|
|
|
|
|
Series 1000 Process Indicator and Alarm
Series 1300 Smart Indicator/Transmitter -- 1/8 DIN, SQRT Function, Universal Inputs, Alarms/Analog Retransmission Outputs
Model A-701 Digital Panel Meter/Power Supply
Model A-705-20 Loop Powered Process Indicator
Series BPI Battery Powered Temperature Indicator -- RTD or T/C Input, 4-Digit Display, Selectable °F or °C
Series DPMA Adjustable LCD Digital Panel Meter -- 1/8 DIN, Loop Powered, Large 3-1/2 Digit Display
Series DPML LCD Digital Panel Meter -- 4-1/2 Digit LCD, Selectable Engineering Units
Series DPMP LCD Digital Process Meter -- 3-1/2 Digit, User Selectable Engineering Units, Panel Mount
Series DPMW LCD Digital Panel Meter -- 3-1/2 Digits, Window Mount
Series DPMX Extra Large Digital Panel Meter -- 3-1/2 Digit LED Display, 2.3" Segment Height, Process Inputs
Series LCI108/LCI108J 3-1/2 Digit Panel Meter -- 3-1/2 Digit Display, Self-Tune/Fuzzy Logic
Series LCI132 Process Indicator -- 1/32 DIN, Fully Programmable
Series LCI308 & LCI408 Panel Meter Indicator -- 1/8 DIN, High Accuracy, Peak & Valley Display
Series LCI508 & LCI608 Digital Panel Meter -- 1/8 DIN, Process, Load Cell & Potentiometer Input
Model LPI Loop Powered Indicator -- Square Root Function and User Defined Curves 4-Digit LED
Model PM706 Temperature Panel Meter -- Dual Alarm, Relay and Analog Output
Series SI Smart Indicator -- Temperature or Process, Interchangeable Output Modules
|
|
|
A comprehensive range of high accuracy multi function digital metering systems offering measurement, display and communication of over 100 parameters, including true RMS measurement for total harmonic distortion and power quality data. Integra products are fully programmable via a simple menu driven interface and can be integrated into energy management systems via various communication protocols. To suit requirements, Integra offers pulsed, analogue and digital output options, and a choice of DIN, ANSI and JIS case styles, with high quality LED or LCD display.
|
|
Universal Inputs: DC Voltage/Current, T/C, RTD, Strain
Accuracy: ±0.005% rdg
6-Digit Tri-Colour LED Display
Up to 166 Readings Per Second
10 Point Linearisation
4 Isolated Open Collector Outputs Standard
Isolated Analogue Output Optional
Four Relay Outputs Optional
Optional Ethernet or RS-232/RS-485
IP66 Front Panel
|
|
|
|
|
|
PAX Series : Large range of Intelligent panel meters
The PAX Meter is the workhorse of our panel meter line-up. From its sunlight readable display to the wide variety of field-installable options cards, the PAX Meter will easily handle your application requirements. Select from the widest range of inputs in the industry, including models for both digital and analog signals. Their Comms capability allows data collection at various points of the machine and communicates the information to your management system, while still providing the machine operator with a localized display. Installing a complete system? Learn how to put a PAX Meter to work for you.
PAXC - Counter
PAXCK - Timer & Real Time Clock
PAXD - DC Volt & Current Input
PAXDP - Dual Process Input Meter
PAXH - AC True RMS Voltage and Current Meter
PAXI - Counter Rate Meter
PAXP - Process Input Meter
PAXR - Rate Meter
PAXS - Strain Gage Input
PAXT - Thermocouple & RTD Panel Meter
PAXTM - Preset Timer
Display of 5 LED digits of 14mm, with variable intensity for good outdoor readability (factor 1 to 15)
These intelligent solutions can be enabled with optional plug-in cards, for set point alarms (2 or 4),analog output and communications (RS232, RS485, Modbus, Devinet, Profibus), enabled Ethernet via external module (ICM8)
|
|
• 3 dgt LED + dummy zero, μ-based
digital indicator, for TRMS AC current and voltage
measurements
• Dip-switch-selectable ranges
• Front dimensions: 48 x 96 mm
• Front protection degree: IP 50 (IP 65 on request)
3-dgt plus dummy zero μPbased indicator, double input for AC current or voltage
measurements. 112 selectable primary ranges. Housing for panel mounting and IP 50 front protection degree (IP65 on request).
|
|
High Quality! Free 5-Year Warranty Extension
User Friendly, Simple to Configure
Free Software, Active X Controls
High Accuracy ±0.5°C, 0.03% Reading
Built-in 10 or 24 Vdc Excitation, Standard
Red, Amber or Green Display Colour Programmable
Related i Series Controller Models are available with a variety of Outputs. Refer to CNi32, CNi16, CNi8
Related i Series Strain and Process Meters and Controllers are available with a Variety of Outputs and Commnunications. Refer to DPiS Panel Meters and CNiS Controllers
|
|
|
|
|
|
The DM500x is a programmable digital panel meter which can be programmed by using the push-buttons. It's possible to select the type of input (voltage, current, thermocouple, thermoresistance, etc.), the ranges, the relationship between input variable and displayed value, the alarms, etc...
Programming is simple thanks to the keyboard with only three push-button and alphanumeric helping messages.
The frontal dimensions are only 48x96mm but the display is visible from far thanks to the optical filter and the size of the digits, 13,5mm for the main display (high efficiency orange) and 10mm for the secondary display (high efficiency green).The depth is 100mm only.
In addition to measuring and displaying functions, these instruments are also able to support up to 4 (four) alarm Set-points with respective open collector output(2 alarm Set-Points if relay output is requested). They also allow the retransmission of measure with analog (i.e. 4¸20mA) or digital output by RS232 or RS485.
There is a three levels' key that protects the safety of setting parameters and acquired data.
It was developed to satisfy the various requirement of regulation and control systems, thanks to the completeness of the offered function and the high number of available configurations.
SMT mounting, powerful microcontroller used, flexibility of use, easy programming are further characteristics.
|
|
|
When your application calls for variable indication, Digital Panel Meters (DPM) are the right tool. Voltage, current, pressure, volume, temperature, frequency and other parameters can be monitored and displayed. With a variety of input and ouput options, DPMs can be used in most any application and the product's short depth makes it flexible and accommodating to panelbuilders' needs.
|
|
For the display of process data, Fuji electric offers a complete line of digital panel meters for all application.
A lot of functions or options (72x36mm or 48x96mm formats - current, voltage, thermocouple, RTD, frequency or pulses - Alarm and re-transmission output...) are available and allow to adapt to all applications.
|
|
1/8 DIN Standard
The K3MA series consists of a process indicator, a frequency/rate indicator and a temperature indicator. All models are equipped with a highly visible LCD display with 2-colour (red and green) LEDs, have a 96 x 48mm front housing and the same short depth of 80mm.
|
|
|
Bronkhorst High-Tech designed the CORI-FLOW series mass flow meter to provide high accuracy (up to ±0,1 % FS plus ±0,2% of Reading). CORI-FLOW utilizes a patented, advanced Coriolis type direct mass flow sensor to achieve unsurpassed performance, even with changing operation conditions in pressure, temperature, density, conductivity and viscosity. The mass flow ranges are from 20...200 g/h up to 6...600 kg/h, both for gases and for liquids. CORI-FLOW instruments are equipped with an IP65 weatherproof housing and are available with ATEX approval for use in Zone 2 hazardous areas.
|
|
|
The CM Series mass flow meters utilize industry's well recognized high accuracy standard, Coriolis technology. The core operating principle of this technology is that fluids flow through a vibrating tube which then causes a deflection of the flow tube proportional to mass flow rate. It is suitable for use with liquids, gases and slurries. Models are available that will measure mass flow, volumetric flow, temperature and density. Unaffected by variations in pressure, temperature, density, electrical conductivity and viscosity, the CM Series provides extremely accurate mass flow measurement over wide flow ranges. The series is comprised of three (3) models which differ by their choices in flow range, wetted parts, accuracy, pressure ratings, density measuring, and other optional functions and features.
|
|
Coriolis mass flowmeters
The SITRANS F C Coriolis mass flowmeters are suitable for measuring various liquids and gases passing through a pipe for dosing, product blending, determining billing or cost and other vital functions. They are the most accurate flow measurement devices today with a repeatability of only 0.1% of the flow and a rangeability of 100:1.
In addition, the measurement is independent of changes in process conditions. Flowmeters based on this technology can measure density, volume flow rate, viscosity, fraction flow and temperature.
|
|
- feed rates: 1 – 160 m³/h
- direct measurement of the feed rate, independent of material properties
- suitable for free flowing bulk solids, granules, and grits
- MechaTronik design (electronics and mechanics form one unit)
- adaptive control electronics (DISOCONT)
- almost maintenance-free
- small installation dimensions
|
|
|
The Brooks QUANTIM® Coriolis mass flow sensor offers unsurpassed accuracy and flexibility in low flow liquid and gas measurement applications. The QUANTIM sensor provides superb communication flexibility. This sensor, combined with Brooks newest transmitter, lets you access more data in your plant’s process language. Direct mass measurement is immune to fluid property variations, providing greater application flexibility and reducing spares requirements. Repeatable mass flow measurement is ideal for variable process conditions. Multivariable output for mass flow or volumetric flow and density or temperature adds diagnostics capabilities and reduces the need for additional instrumentation. ANSI/ISA SP-76 downport configurations. Globally approved for a variety of service areas.
|
|
Coriolis mass flow meters for fluids of all kinds, e.g. for paints and PU-components
Specifications:
Measuring ranges: 4.5...3,000 kg/h
Repeatability: 0.1% of actual value
Linearity: ±0.5% of actual value
Connections: female threads G1/2", adapters for flanges, diary or tri-clamp
Pressure: max. 350 bar
Temperature: max. +125°C
Ex protection: EX II 2G EEx ib IIC T2–T4
EMC-tested
|
|
Following the repurchase of the Heinrichs company, KOBOLD has maintentant a wide range of flowmeters.
The mass range of flowmeters Coriolis TM, TMU, TME of KOBOLD is
very wide and comprises unequalled specificities:
- DN2 with the DN300
- of 0.8 kg/h up to 2.200.000 kg/h
- stainless tubes, hastelloy or tantalum
- possibility of tracing or powerful cooling
- up to 900 bar
- counsel commercial transactions for certain countries
- universal electronics (binder, profibus, modbus, contacts, frequency, 4-20mA)
- version ATEX
|
|
The universal solution for the process industry
OPTIMASS 1000 is the only sensor for mass flow in its class with secondary pressure containment as standard. OPTIMASS 1000 reliably measures mass flow of liquids and gases, concentration and density of liquids.
Highlights Innovative twin measuring tube
Easily drained and easy to clean
Regardless of type of installation and external factors
Long working life
Optimized flow divider for minimum pressure loss
High accuracy with best price-performance ratio
Modular electronics concept: electronics and sensor easy to replace
Data redundancy: accurate plug & play replacement of electronics
|
|
|
|
|
|
The CoriolisMaster (FCM2000) is designed for the measurement of mass, volume, density, concentration and temperature the highest accuracy.
The Coriolis technology is ideal for demanding fluid measurement applications – independent of whether the fluid is conductive, multi-phase or viscous. The measuring pipe is self-draining. The device’s self-diagnostic and digital signal processing functions ensure high long-term stability and reliability.
The new CoriolisMaster series offers improved signal processing and an impressive turndown-ratio of up to 1:2000. The approvals for explosion protection have been revised completely. Besides IECEx approvals they now include new zone 2 instruments and excellent temperature classes. Additionally specific software solutions like concentration calculation are offered. Together with its wellproven S shape tube design a CoriolisMaster represents the multi-purpose flowmeter for virtually all applications.
- Excellent temperature classes for hazardous areas.
Even for compact instruments Tmed 200°C with Tamb 60°C is no problem at all.
- New: IECEx and zone 2 approvals
- Easy to install and operate
- Simple to high precision solutions in one design
- Single transmitter for all sensors with 'easy setup' quick start routine and FRAM technology
- Unique, universal explosion protection concept giving plant cost saving
- Comprehensive diagnostics on board
- Common HMI interface saves maintenance and training costs
- Accuracies flow up to 0.1 % of rate and 0.001 kg/l for density
- Wide flowmeter size range from 1/16“ to 6“ / DN 1.5 to DN 150
- Various process connection options
|
|
|
|
|
|
No limits with tube materials
Titanium, Hastelloy, or Stainless Steel allow straight tube metering for almost any process.
No limits with flow
From 0.3 to 560,000 kg/h with a full range of meters for low and high flow applications.
No limits with measured product
High viscosity, particulate matter, inhomogeneous mixtures, normal entrained air, have little effect on the accuracy of the measurement.
No limits with installation
Support on the process pipe or the meter body, without the need for accurate positioning. A complete range of process connectors for all existing and future installations is available.
No limit with electronics
OPTIMASS has been designed with all new electronics, which incorporates Front End signal processing that is permanently mounted to the meter. This provides high speed and low noise measurement, as well as remote connection to the signal converter up to 300 m. Dual redundancy of configured data, calibration constants etc ease maintenance.
No limits with applications
KROHNE can provide metering solutions whatever your requirement including: Flow, Density, Concentration and Temperature
|
|
Non-conductive and conductive liquids, liquefied petroleum, gases.
The TME can be used in many applications common to chemical, petrochemical, oil and gas, food and pharmaceutical industries.
The TME Series is also used for precise dosing and for custody transfer applications.
Mass flow, density and temperature are simultaneously monitored and volumetric flow is additionally calculated with these parameters.
|
|
LCMass™ Coriolis Mass Flow Meters
- Sizes: 1/4" through 12"
- Flow Rates: 0.004 lbs/min to 50,000 lbs/min
- End Connections: ANSI Flanged, Threaded, Sanitary
- Pressure Ratings: 150 - 2,500 ANSI
- Materials of Construction: 316 Ti Stainless Steel (Hastelloy and Tantalum available on request)
- Accuracy: Capable of ±0.2% of rate over 20:1 range
- Repeatability: Capable of 0.1% of flow rate
|
|
Foxboro Coriolis flow transmitters handle measurements that cause other Coriolis meters to fail. They overcome problems associated with entrained gases, empty tube conditions or flash-prone fluids and fully realize the promise of Coriolis measurement to achieve high accuracy, eliminate downtime, avoid workarounds and keep profits flowing.
Features:
- Highly accurate mass, density and temperature measurement
- Unprecedented, precise liquid/gas flow measurement without skips or stalls
- Fast startup — up to 10 times faster than conventional Coriolis meters
- Highly accurate batches, starting from empty tube
|
|
|
|