SW 10C
Blackbody Radiation Sources SW 10C
for Calibration of Infrared Radiation Pyrometers
High Accuracy with Controller
Blackbody Radiation Sources with Controller for Infrared Radiation Pyrometers
Temperature range 50°C to 400°C
Calibration and control of pyrometers
Digital control, control accuracy 0.1 K
Control parameter adjustable
Isothermie from 0.1°C, better than 1°C
Cavity aperture 25 mm
|
|
Blackbodies are reference sources used for testing infrared systems. They are required in industry for calibration of pyrometers, infrared line scanners or cameras.
In Defence, they are part of benches for characterisation of complex optronic systems. HGH offers a wide range of blackbodies to cover all Customers’ needs:
- DCN 1000N Differential blackbody for characterization of infrared system performances
- RCN High temperature cavity blackbody for calibration of infrared sensors
- ECN 100 Extended area blackbody for field tests and calibration without collimator
- DCN 1000L Low temperature blackbody
- DCN 1000N Vacuum cryogenic temperature blackbody for space borne systems testing
In addition, HGH have the ability to design specific infrared sources on request.
In many cases, blackbodies are associated to test targets/target wheels and incorporated into infrared collimators (IRCOL).
Contact us with your specifications.
|
|
Calibration Sources or blackbodies are radiation sources with a nearly ideal emissivity in the infrared spectrum. These products generate reference temperatures for the calibration of thermometers, pyrometers, imaging systems and spectometers (Temperature ranges from -40 to 3000°C).
An extensive range of blackbodies guarantee the transfer of national calibration standards according to e.g. NIST, DIN/ISO and DKD. The instruments are used across industry and research. All blackbody calibration sources, wether standard or custom, are designed for the highest emissivity possible, largest aperture sizes and highest accuracy.
For detailed information please see:
www.impacinfrared.com/EN/products/calibration-sources/calibration-sources.html
or
www.mikroninfrared.com/products/products-s3-blackbody.htm
|
|
The IR-R0 series is practical use type blackbody furnaces that are used as the standard unit for comparison calibration of radiation thermometers.
NRLM Type Comparison Blackbody Furnaces IR-R24, IR-R26
High Temperature Comparison Blackbody Furnaces IR-R27
NRLM type comparison blackbody furnaces, which have been jointly developed with the National Research Laboratory of Metrology, are large opening blackbody furnaces for calibration of radiation thermometers, and a high temperature comparison blackbody furnace uses a standard radiation thermometer for comparison calibration.NRLM Type Comparison Blackbody Furnace
Practical Use Precision Type Comparison Blackbody Furnaces
IR-R6, IR-R7, IR-R8
Practical use precision type comparison blackbody furnaces cover the temperature range of 100 to 3000°C by 3 kinds of blackbody furnace and calibrate radiation thermometers accurately.
|
|
Blackbodies are reference sources used for testing infrared systems. They are required in industry for calibration of pyrometers, infrared line scanners or cameras.
In Defence, they are part of benches for characterisation of complex optronic systems. HGH offers a wide range of blackbodies to cover all Customers’ needs:
- DCN 1000N Differential blackbody for characterization of infrared system performances
- RCN High temperature cavity blackbody for calibration of infrared sensors
- ECN 100 Extended area blackbody for field tests and calibration without collimator
- DCN 1000L Low temperature blackbody
- DCN 1000N Vacuum cryogenic temperature blackbody for space borne systems testing
In addition, HGH have the ability to design specific infrared sources on request.
In many cases, blackbodies are associated to test targets/target wheels and incorporated into infrared collimators (IRCOL).
Contact us with your specifications.
|
|
Features
- Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F)
- Large 57 mm (2.25 in) blackbody target
- RTD reference well for high precision
- Small, compact design
|
|
A comprehensive range of six LANDCAL blackbody calibration sources provides high precision calibration of radiation thermometers within the temperature range -10 to 1600°C/15 to 2900°F, both on-site and under laboratory conditions.
The sources are divided into two main groups, classified as being either primary or reference standard. The primary and reference standard sources are further divided into Portable, Transportable or Bench mounted groups.
Primary Standard Sources
The calibration of a primary source is traceable directly to National Standards via a certified probe installed in the radiation cavity.
Reference Standard Sources
Traceability to National Standards can be achieved either by using optional certified radiation thermometers for calibration by the comparison method, or by purchasing a certified source.
|
|
CalCheck is an easy to use reliable tool for the self calibration of gas and leak detection instruments, giving you peace of mind and confidence in the accuracy of the measurements you rely on.
For your convenience the same base unit can be used for calibration with many different gases and leak rates. Ion Science can supply almost any non corrosive gas at varying concentrations and the instruments leak is easily removed allowing the use of a specific leak rate when required ensuring calibration to your exact needs.
|
|
The DS2 Docking Station provides the ultimate flexibility for managing your gas monitors wherever you use them. The DS2 gives you all of the benefits of consistent automated calibration, record keeping, battery recharging and instrument diagnostics for your monitors to limit your liabilities and safety hazards. Two way wireless and/or ethernet connectivity enables you to link up to 100 stand-alone Instrument Docking Stations (IDSs) from remote locations anywhere in your facility and relay the data back to one central database for total instrument management. A graphical user interface tool (DSSAC) allows an administrator to view operations on each Docking Station from a network computer, making it easy to track instruments, print reports, set events and change parameters for any location.
|
|
|
Gas sensors are usually installed in hard to reach places: inside pits, over vats, high under roof and skylights. To eliminate the labor and risk to personnel perfoming routine calibration on these sensors, Rel-Tek developed its unique Magikal and Magikal-II automatic gas sensor calibration (AGSC) utilities. These powerful technologies have been proven over the years at installations from Massachusetts to California , from Michigan to Texas. Users appreciate freedom from the calibration nuisance, while saving a lot of money to boot.
|
|
|
|
|
|
What if you could maintain and manage your fixedpoint gas monitor fleet without leaving your desk?
The advantages would be significant. Manually calibrating every fixed monitor in a facility is a time consuming distraction from your core business. The units may be in hard-to-reach places creating additional safety hazards. These and other obstacles make it difficult to follow industry best practices for routine testing and calibration.
iTrans™ DS2 Docking Station™ is the first system to automate calibration, record-keeping and instrument
diagnostics for fixed-point gas monitors. Hands-off maintenance and a snapshot view of your entire gas
monitor fleet allow you to:
• Maintain your gas monitors more safely, efficiently and reliably
• Increase equipment reliability
• Eliminate safety concerns
• Save money on calibration and testing
• Focus more resources toward your core business
A graphical user interface tool allows an administrator to view operations on each Docking Station from a network computer. From here, you can initiate calibrations and instrument tests remotely, print reports, set events, and run diagnostics for any or all instruments at any location.
The DS2’s flexible architecture minimizes installation costs, whether you’re managing one instrument or an entire fleet of fixed-mounted or portable instruments.
|
|
| ... products without technical information |
| |
The Model 700E is a microprocessor based calibrator for
precision gas analyzers. Using a combination of highly
accurate mass flow controllers and compressed
sources of standard gases, calibration standards are
provided for multipoint span and zero checks. Up to 4
gas sources may be used.
In addition, the Model 700E can be equipped with an
optional built-in, programmable ozone generator for
accurate, dependable ozone calibrations and to produce
NO2 when blended with NO gas in the internal GPT
chamber.
|
|
|
|
|
|
The MicroDock II is the world’s most advanced, compact and affordable automatic calibration, testing and data management system for portable gas detection equipment. Compatible with BW’s GasAlertMicro 5, GasAlertMicro 5 PID, GasAlertMicro, GasAlertMicroClip, GasAlert Extreme and GasAlertClip Extreme family, the MicroDock II is expandable to up to 10 docking modules (including up to 6 charging units).
- Fully automatic “hands-free” calibration & functional bump test
- Automatically verifies performance of audible and visual alarms
- No computer required
- Entirely self-contained
- Fully portable
- Lightweight and mobile
- Operates via line power or a set of four C-cell batteries
- Add additional self-contained docking modules to system via simple, plug-in connections-no external pressure transducers or gas lines necessary
- Simplify record keeping
-Verify proper performance
- Reduce maintenance costs
- Multiple MicroDock II systems can be connected via a LAN
- Multi-language support in English, French, German, Spanish, and Portuguese
|
|
The new CheckBox IMH automates the routine gas (bump) testing, calibration and management of Crowcon portable gas detectors and facilitates the traceability and routine maintenance of instruments. Capable of operating with up to 10 instrument interfaces, CheckBOx IMH is available for use with the Tetra, Triple Plus Plus and Gasman products.
* Automatic gas (bump) testing
* Automatic calibration
* Can use single gases or quad mixtures
* Up to eight gas inlets
* Five or ten instrument interfaces
* Accommodates pumped or non pumped instruments
* Data and event file uploading
* Stores and controls configurations
* Records all activities
* Provides reports and certificates
|
|
The DS2 Docking Station provides the ultimate flexibility for managing your gas monitors wherever you use them. The DS2 gives you all of the benefits of consistent automated calibration, record keeping, battery recharging and instrument diagnostics for your monitors to limit your liabilities and safety hazards. Two way wireless and/or ethernet connectivity enables you to link up to 100 stand-alone Instrument Docking Stations (IDSs) from remote locations anywhere in your facility and relay the data back to one central database for total instrument management. A graphical user interface tool (DSSAC) allows an administrator to view operations on each Docking Station from a network computer, making it easy to track instruments, print reports, set events and change parameters for any location.
|
|
GasCal 1100 Gas Dilution Calibrator
The Ecotech GasCal 1100 Gas Dilution Calibrator performs precise
gas dilution calibrations, ozone analyser precision checks and gas
phase titrations using an optional internal ozone generator. It is
ideal for stand alone use or incorporation into ambient air or emissions
monitoring systems.
• Single and multipoint calibrations can be performed using precise mass flow controllers
• Perform gas phase titrations (U.S. EPA Method) and ozone precision checks using an internal ozone generator (option)
• Parameter setup and output via inbuilt LCD and keypad or an external PC
• External remote control possible via data acquisition system or suitable gas analyser
• Mass flow controller zero stability drift less than 0.6 % full scale per year
• Optional Carry case allowing the GasCal-1100 to be securely carried from location to location
• Optional purge facilitates flushing of calibration gas lines
|
|
| ... products without technical information |
| |
|
|
|
|
The fast, one-handed tool for loop checks in Ex zones
The 707Ex is an intrinsically safe loop calibrator for use in explosion endangered areas.The ecom 707Ex is certified in accordance with the ATEX directive (Ex II 2 G EEx ia IIC T4)in Zones 1 and 2.The 707Ex is also certified to operate in accordance with Factory Mutual N.I.Class 1, Division 2 areas Group A-D.
- Large display and simple,,quick-click push
rotary button for easy one-handed operation.
- Simultaneous mA and %%readout for
quick,easy,interpretation of readings.
- mA accuracy of 0.015%%
- 1 µA resolution for mA source,simulate and measure.
- Push button with 25%%steps for fast, easy linearity checks.
- 0--100%"span check ” for fast confirmation of zero and span.
- Internal loop supply,,so you can power and read a transmitter at the same time without carrying a DMM.
Measures V dc to 28 V..0--20 mA or 4-20 mA default start up modes. HART ® compatible resistance is connected in series with the loop supply for compatibility with HART communicators.
|
|
|
Process signal measurement and simulation for easy control loop calibration and measurement tasks - from handheld field instruments for multi or single signals to laboratory reference level bench top instruments.
|
|
The ecom MA 400 Precision Loop Calibrator provides significantly extended performance when compared to any competitive calibrator.With an accuracy of 0.015%of reading,with 0.001 mA resolution,the MA 400 has the highest accuracy in its class.Unique features,such as a "%Error ” function,which eliminates manual error calculation and allows the display of the actual versus ideal error at any calibration point,put the MA 400 way beyond similar instruments.
|
|
Emission Reference Sources are small, self contained emitters which generates a known, measured field strength at a standard measurement distance. ERS and EMC10.3G ensures measurement integrity and reduces measurement uncertainty.
ERS and EMC10.3G obtains true end-to-end calibration - including site conditions, antenna and receiver.
ERS and EMC10.3G cover frequency ranges from 30MHz to 3 GHz, and have ultra-stable emission levels with traceable calibration.
|
|
Your VNA provides you with the most accurate measurements only if calibrated against known standards. Pasternack VNA Calibration Kits and Tools incorporate accurate, stable, and precise calibration standards designed for a broad range of vector network analyzers models, including Agilent and Anritsu products.
The 3.5mm Standard and N-Type Standard Calibration kits are designed for use with a broad range of vector network analyzers (VNAs) that utilize a Short-Open-Load calibration technique. With the kits you can make error-corrected measurements of devices supplied with either 3.5mm or SMA connectors from DC to 26.5 GHz, or from DC to 11 GHz for N-type connectors. The kits contain both Male (Plug) and Female (Jack) connector interfaces to perform full Two-Port error corrections.
FEATURES:
- Broad VNA Coverage, Including Agilent & Anritsu
- Open, Short, Fixed Broadband Load Configurations
- DC to 26.5 GHz
- In-Series Phase Matched Adapters Available
|
|
|
|
|
|
The leaks digital calibrator takes its origins by the needs to know the leak-off rate entity on volumetric terms [cc/min] or [cc/h].
Such requirement exists especially when tests are executed on air and gas sectors parts, on which the norms express the
leakage rates in [cc/min] or [cc/h].
The instrument is combined with a micrometrical cock (supplied in the equipment) in order to simulate the desired leak. ET11 allows the seal tests instrumentation parameters programming procedure.
This flow measure instrument utilizes a mass flow sensor and it is able to point out with precision and reliability the leakage
rates contained between 0,00 and 30,0 [cc/min].
This portable instrument, with compact dimensions and simple usage, is essential to verify the measure instruments and nozzles samples calibration and repeatability.
Compact dimensions:
ET11 is a portable instrument with extremely reduced dimensions: length 180[mm], width 80[mm], depth 35[mm] and weight 250[g].
Precision:
Measure resolution of 0,01[cc/min] till 6 [cc/min] and 0,1[cc/min] till 30[cc/min], measure uncertainty inferior to 1,5%.
Double scales:
2 measure scales: flow visualization in [cc/min] and [cc/h]
|
|
The leak / flow calibrator allows the checking of the calibration of leak and flow measurement instruments, as well as calibrated leaks and jets. This portable, compact and user friendly instrument is essential for checking the accuracy and repeatability of all leak and flow testers. You can now guarantee the quality of your products, whilst also complying with requirements such as ISO 9000
|
|
They could be used as pressure calibrator to check and certify the pressure measures of the leak tester equipment.
Also they could be used as leak simulator to check if testers are capable of identifying as "test FAILED" a cc/min determined leak on the objects to be tested.
With LTC the user can issue reports on the tester performances and certify them in conformity wit the ISO9001 standards.
LTC instruments helps the user in choosing in an easier way the better test parameters to be programmed on the testing machines.
The leak is set with a micro-needle valve: an other open/close valve make easy to insert or eliminate the leak without changing the setting.
The instruments supply with a rechargeable battery.
|
|
Model 3590 Digital Electronic Calibrator
Epsilon's calibrator features 50 microinches (0.001 mm) resolution and has full 2 inches (50 mm) of measuring range.The autozero button and digital display greatly simplify calibration of extensometers. It is also available in an ultra-high resolution version with 5 microinch (0.1 micron or 0.0001 mm) resolution.
|
|
| ... products without technical information |
| |
CALIBRATOR SP - Vital for Quality Assurance and ISO 9000
-Used for periodic verification and calibration of AC, AC-HF, DC, and Impulse Spark Testers of any model and any make. Complies with all Spark Tester standards.
-Test voltage and short circuit current measurement can be certified.
Important Features:
-Measures all existing categories of test voltages
-Measures test voltage, short circuit current, frequency, fault sensitivity
-Easily accessible on the line, thanks to compact and ergonomic design
|
|
|
|