Additional specifications
·Large measurement range (–50°C to +1,000 °C)
·Accuracy ± 1.5% ± 2 °C
·D/S targeting ratio 30/1 ·Continuous measurement functions, high and
low alarms, Min/Max/Average, HOLD
|
|
Compact thermometer with wide temperature range
* Measures temperature from -58 to 1000°F with 0.1° resolution up to 199.9°
* Built-in laser pointer identifies target area
* Backlighting illuminates display for taking
measurements at night or in areas with low
background light levels
* Overrange indicator
* Automatic Data Hold when trigger released
|
|
|
|
|
|
The new VL miniature infrared temperature sensor from Calex Electronics is designed to offer maximum flexibility in the smallest possible package.
The VL can measure temperatures from - 40ºC to 700ºC with a response time of just 180ms. It has a narrow 10:1 field of view, and adjustable emissivity so can be configured to measure most materials. Each unit offers a choice of either 0/4 to 20mA, 0 to 5V or type J or K thermocouple outputs so can be used with virtually all process control instrumentation.
Under the lid of the electronics enclosure are buttons which are used to adjust the configuration parameters of the sensor and set the temperature range, response time and output. From here the analogue outputs can also be configured and maximum/minimum readings switched on or off.
To compliment the analogue outputs the VL also provides a digital relay output, the alarm level and hysteresis of which can be adjusted with the electronics module. The VL also has an RS-485 interface for connection to a PC, and can be
interrogated using the UPP® (Universal Pyrometer Protocol).
The compact sensing head of the VL is made of stainless steel and is sealed to
IP65. It can operate in ambient temperatures up to 85ºC without cooling, or 200ºC with air-cooling and purging accessories.
|
|
With its combination of flexibility and power, the Thermosight Series offers a reliable solution to most non-contact, infrared temperature measurement applications.
Adjustable emissivity in 0.01 increments and a choice of different spectral ranges enables the Thermosight Series to measure the temperature of most surfaces.
The backlit LCD display indicates the current, max, min, average or difference
temperature, providing more information at a glance. Whilst the Thermosight’s built-in laser sighting clearly indicates the target being measured.
A USB interface is available, allowing communications between the handheld unit and a PC if required.
|
|
|
|
|
|
PyroSight series sensors feature a variety of input, output, and alarm options to enable advanced process monitoring and control. Each sensor can be configured to operate as a stand alone sensor or with a remote Interface Module.
The sensor can be set to an analogue (A) configuration for operation with a digital indicator, PID Controller, or PLC. In addition to providing an analogue output, the sensor may be configured for an alarm relay output (default) or a remote analogue input for adjustment of the sensor’s alarm set-point or emissivity.
Alternatively the sensor can be set to a digital (D) configuration (RS485) for operation with the Interface Module, a PC or a PLC. The 1/4 DIN Interface Module includes an RS232 connector for interface with the PyroSight PC
Software.
Features:
• Temperature ranges up to 2475°C
• Traditional or fibre-optic versions
• Optional laser sighting or aiming light
• Built-in digital display and controls
• Optional interface module
• Adjustable range, emissivity and signal processing
• Precision optics
• Rugged stainless steel enclosure
|
|
|
LAND offer a comprehensive range of fixed installation radiation thermometers and thermometer systems for continuous on-line temperature measurement and control within the range 0 to 2600°C/32 to 4700°F.
|
|
The first non-contact thermometer of its class incorporating a digital display, setting panel, and output function.
(1)measure temperature with any contact-type thermometer
(2)input the temperature value of (1)
(3)the unit automatically calculates the emissivity ratio and stores result in memory.
|
|
Features
Wide Range Temperature Range
Wide range measurement of 400 to 1200 can be possible for variety of applications.
Scaling Function
Temperature range of the Analog Output (4 to 20mA) is variable to connect to the recorder easily.
|
|
CA876 Infrared Thermometers
The Infrared Thermometer Model CA876 is a non-contact infrared temperature measuring instrument. It includes a 3 1/2 digit backlit LCD, auto-hold function and auto power off (15 seconds). The MEAS button is used to extend the battery life by automatically stopping measurement temperature and holding the display reading.
The Model CA876 features a laser guide for precise measurements. It also includes a K-type thermocouple input for taking temperature measurements. The Model CA876 offers MIN and MAX recording features, which allow the operator to view the minimum and maximum values recorded during the test; an alarm feature with a specified Lo value or a specified Hi value to be programmed, causing the instrument to emit a tone if the measured value falls outside the parameters; and adjustable emissivity from 0.1 to 1.00.
|
|
Non- contact temperature measurement
Measuring range -20 ... +500 up to -30 ... 900 °C
Measuring Accuracy ± 1 % up to ±2 % of m. value
Option analogue output, RS 232, data memory,
Laser pointer,
statistical functions
|
|
The Land Cyclops family of high quality portable infrared thermometers provide accurate and reliable precision spot temperatures in a wide range of industrial applications from -50 to 3000°C/-50 to 5400°F.
Features
Precise view of target spot with simultaneous digital display of temperature in the viewfinder
Choice of measuring modes - Peak, Continuous, Valley
Calculating modes to compute maximum, minimum or mean of a series of readings
Digital output and out of range alarm
Cyclops thermometers are widely used in many different industries such as glass, metals, minerals, chemical and plastics, for process monitoring, quality control and general research or predictive maintenance.
|
|
with a high optical resolution and narrow field of view, PT-3LF enables you to aim the object from a safe distance.
coaxial laser marker pin-points the center of the measuring area.
|
|
Description & Features:
• A portable "point and shoot" thermometer that measures remote surface temperatures
• Digital readout (°F or °C)
• Single hand operated
• Uses less than 1 milliwatt of power
• Auto power off feature to conserve battery
• 9 volt battery powered
• Fast response time (0.25 seconds)
• 1 year warranty
Applications:
• To measure remote surface temperatures on bearings, electrical panels, assembly line machines, pumps and concrete construction
|
|
- Instant surface temperature readings, squeeze the trigger and aim using the laser dot
- Wide temperature range -40ºC to +420ºC
- Distance to spot ratio 8 to 1
- three pre-set emissivity settings
|
|
The LAND Cyclops family of high quality portable infrared thermometers provide accurate and reliable precision spot temperatures in a wide range of industrial applications from -50 to 3000°C/-50 to 5400°F.
Cyclops thermometers are widely used in many different industries such as glass, metals, minerals, chemical and plastics, for process monitoring, quality control and general research or predictive maintenance.
|
|
Hi alarm
When any temperature higher than a preset value is measured, an alarm LED(red) turns on and an alarm bell (high tone) goes off.
Lo alarm
When any temperature lower than a preset value is measured, an alarm LED(green) turns on and an alarm bell (low tone) goes off.
|
|
easy to check temperature with wide display and auto backlight.
You can get measurement, laser guide, and backlight function with pushing the measure button.
with releasing the measure button, display is hold and auto off after 20 seconds.
small and light, easy to carry, 180g in weight
|
|
The METRATHERM 1 is an infrared thermometer with laser sight for contactless measurement of surface temperature. Applications:
- temperature at a safe distance from danger zones
- electrical trouble shooting
- automotive industry
- air conditioners
- scientific experiments
- semiconductor manufacturing processes
- contacts in electrical control cabinets
- food monitoring and processing.
|
|
IP6*
no dust comes inside the body.
IP*7
no water comes inside the body by immersing in water for 30 minutes in 1m depth.
99 points data memory
an alarm turns on and alarm bell goes off
±1 of reading value
|
|
The 610 LC infrared thermometer allows you to gauge the surface temperature precisely – quickly and safely, with no contact.
Infrared thermometer 610 LC - for -20°C to +260°C
LCD Display
Resolution: 1°C
Measuring rate: 2,5 times per second
Automatic switch off
Laser spot marker
|
|
IT-540 Series handy Non-Contact Infrared Thermometers
Product Overview
The hand-held IT-540 is a non-contact, thermal-radiation-type thermometer that uses a point marker to clearly designate the measurement location.
In addition to being very portable, the IT-540 is easy to use, and is equipped with a range of advanced features that provide a high level of functionality.
It is ideal for remote temperature measurement in dangerous applications such as monitoring abnormal heat generation in high-temperature voltage transformer equipment, and for quick, accurate and hygienic monitoring of the storage temperature of foodstuffs.
The twin-beam marker provides clear target designation, and the operator is immediately notified of temperature abnormalities by an alarm and flashing of the marker.
|
|
|
|