H-Shield is a rigid roof insulation panel composed of a closed cell
polyisocyanurate foam core bonded on each side to fiber
reinforced facers.
FEATURES AND BENEFITS:
- Manufactured with NexGen Chemistry - Zero ODP, CFC Free,
EPA Compliant.
- Approved for direct application to steel decks.
- Approved under all major roof covering systems - BUR, Modified
and Single Ply.5
|
|
H-Shield-WF is a rigid roof insulation panel composed of a closed
cell polyisocyanurate foam core bonded during the manufacturing
process to fiber reinforced facers on one side and 1/2"(12mm)
asphalt coated high density woodfiberboard on the other.
FEATURES AND BENEFITS :
· Manufactured with NexGen Chemistry™ - Zero ODP, CFC Free,
EPA Compliant.
· Approved for all major roof covering systems – BUR, Coal Tar,
Modified and Single Ply applications.
PANEL CHARACTERISTICS :
· Available in 47.5"x47.5" (1207mm x 1207mm) and 47.5"x8'
(1207mm x 2440mm) panels in thickness of 1.5"(38mm) to 4.5"
(113mm)
· Available in two compressive strengths per ASTM C1289-06,
Type IV, Grade 2 (20 psi). Grade 3 (25 psi).p
|
|
H-Shield-CG is a rigid roof insulation panel composed of a closed
cell polyisocyanurate foam core laminated to coated glass fiber
mat facers. (Gray)
FEATURES AND BENEFITS :
· Manufactured with NexGen Chemistry - Zero ODP, CFC Free,
EPA Compliant
· Premium facer improves water resistance and dimensional stability.
· Enhanced performance with cold applied BUR, Modified Bitumen
and Fully Adhered Single Ply systems.
· Meets FM 4450 and UL 1256 for direct application to metal deck
construction.
|
|
H-Shield-AGF is a rigid roof insulation panel composed of a
closed cell polyisocyanurate foam core bonded on each side to
AGF (all glass) facers.
FEATURES AND BENEFITS :
· Manufactured with NexGen Chemistry™ - Zero ODP, CFC Free
· Approved for direct application to steel decks.
· Approved for Ballasted and Mechanically Attached Single-Ply only.
STANDARD SIZES :
· Available in 4'x4' (1220mm x 1220mm) and 4'x8' (1220mm x
2440mm) panels in thickness of 1"(25mm) to 4.0" (102mm)
· Available in two compressive strengths per ASTM C1289-06 Type II,
Class I, Grade 2 (20 psi), Grade 3 (25 psi)
APPLICATIONS :
· Constructions requiring FM Class 1 and UL Class A ratings
· Single-Ply Roof Systems (Ballasted, Mechanically Attached)
|
|
roof insulation (inverted roof)
The inverted roof is a construction by which the STYRISOL® insulation boards are placed above the waterproof membrane. The insulation is loaded with an additional ballast layer. Insulation boards are installed loosely on the roof covering.
|
|
CAVITY WALL INSULATION
STYRISOL® insulation boards are placed with the tongue upwards, close to one another and on the inner cavity wall. A ventilated cavity of at least 4 cm is needed. The wall ties have to be installed so that water cannot penetrate into the inner wall. At ground level, a damming layer needs to be applied. Water is drained off through the open grooves.
|
|
Cool-Vent is a venting composite insulation board that consists
of a 4' x 8' panel of NexGen Chemistry polyiso, a middle
layer of solid wood spacers and a top layer of APA/TECO rated
OSB or plywood. Cool-Vent is the environmentally intelligent
choice for steep slope roofing applications and is viable in
green and sustainable building designs.
|
|
|
|
|
|
INSULATION PADS - for hot surfaces.
Thermal Insulation Pads are ideal for gas turbines, valves, filters, meters and other accessories in a process line. They insulate the hot surface, ensuring energy conservation, protection of operators and providing comfortable work environment. These are typically used as a backing over the heating jacket or heating panel, to ensure better heat efficiencies and minimal energy loss is minimal.
The flexible construction of 'Thermo Insulation Pads' enables tailoring to any complex shapes and providing a perfect, snug fit on complex shaped surfaces.
Construction
Insulation pads consist of 2" thick (or as required) lagging of fibre glass wool insulation, embedded in two layers of fibre glass cloth. Outer layer of fibre glass cloth can be flame retardant aluminized or PVC coated or Teflon coated as required.. The final pad is shaped based on the required surface to be insulated to encapsulate the surface or equipment in it. Required cutouts for obstructions and velcrow or eyelets and strapping lays are provided to make it snug fit on the surface or equipment.
Range
Insulation pads are designed for a maximum surface temperature of 300ºC.
Every Insulation pad is custom designed based on customer requirement.
|
|
Features:
- High ventilated performance, non-block or deposit of welding flux in the cell
- Imported high magneto-conductivity steel strip, good effectiveness in both low and high frequency
- Surface processing methods based on different environments
- Shielding effectiveness of steel and copper vent panels
|
|
| ... products without technical information |
| |
| ... products without technical information |
| |
| ... products without technical information |
| |
Electrical insulating parts made with SMC insulating plates, glass fibre reinforced epoxy resin plates and other kinds of insulating plates. The insulating parts include underprops, partition walls, insulating screws and nuts.