|
|
Bench Top & Cupboard Styles
Evaporation from drips and open containers contributes considerably to poor quality air within the laboratory. The Bigneat range of storage cabinets removes vapours, purifies the laboratory air and enhances the long-term health of laboratory personnel.
Main Features:
. Continually cleans up and purifies laboratory air.
. May be used when ducted extraction is unavailable.
. No outside exhaust necessary for vapours.
. Fully mobile, a simple electrical connection is all that is needed.
. Energy saving, cost effective & safe. |
|
THE AIR OF THE LABORATORY IS PURIFIED
The air released by the filter contains 100 times less pollutants than the acceptable values defined by official authorities.
STANDARD EQUIPMENT :
•Electronic "fan failure" alarm for the continuous monitoring system of the ventilation.
•Sampling port for testing the saturation level of the filter.
VERY SILENT TURBINE FAN
Only 49 dBA
GOOD VISION OF THE STORAGE
Thanks to lockable transparent UV resistant door.
EASY TO SET-UP CLOSE TO THE USERS WORKSTATION
Does not require any ducting.
SPILL TRAY FILLED WITH AN ABSORBING MAT
To contain potential spill from broken containers. |
|
AirClean Systems PCR Combination Workstation
AirClean®Systems PCR workstations with UVTect™ microprocessor control, allow you to maintain a Class 100 clean work area during PCR preparation. The AC600 Series LFUV Model has a built-in 254 nm ultraviolet light that allows the operator to irradiate tubes, flasks and pipettes between amplifications. The 254 nm ultraviolet light will effectively destroy potentially contaminating DNA and RNA within minutes. UVTect™ monitors the life of the bulb to ensure proper levels of irradiation.
The workstations feature a unique interlocking sash with a safety overlap to prevent gaps. The sash also has a safety switch that automatically turns off the ultraviolet light and activates the blower and fluorescent light when the sash is raised. This revolutionary uni-body design provides unmatched user protection from harmful ultraviolet rays during the sterilization process. HEPA filtered units have a built-in monitoring system to alert the user when to change the HEPA filter.
|
|
BIGNEAT's PCR UV workstation efficiently protects against contamination by bathing PCR aparatus in sterile air and limiting the risk of contamination from the operators arms, or from equipment bought into the otherwise sterile environment.
Powerful UV lamps are combined with optical reflectors to ensure uniform intensity distribution of the sterilising UV radiation.
1. Superb all round vision
2. Electronic filter saturation indicator
3. Quiet operation
SPECIAL BIGNEAT FEATURE: Fan speed increases when door is opened to maintain air velocity to 0.45 m/s at the front access aperture.
Available 800mm wide as PCR UV cabinet, or as a UV sterilisation cabinet (no HEPA filtration) |
|
POWERFUL UV DECONTAMINATION
The UV lamp insures a full decontamination of the entire work surface, enclosure walls and PCR equipment.
AN ERGONOMY OF QUALITY
The ergonomy of the working apertures is unique. It enables the protection of the handling while allowing the operator to have access to the entire surface of the enclosure.
ENCLOSURE SIZE ADAPTED TO ALL PCR EQUIPMENT
The Biocap™ enclosures have been sized to receive tube racks, pipettes, minicentrifuges and thermocyclers.
PROTECTION OF THE OPERATOR
The enclosure is 10 mm thick so as to insure a full protection against UV and B rays.
AUTOMATIC SHUTT OFF OF THE UV LAMP
The UV lamp switches itself off automaticaly if the door is opened by accident while the lamp is still active.
*PCR is a patented process owned by Hoffmann-La Roche |
|
AirClean Systems PowderSafe Balance Enclosure
AirClean® Systems PowderSafe™ Type C enclosures incorporate the airflow characteristics and HEPASafe™ filtration technology of the Type B enclosures while offering the chemical adsorption capability of our ductless fume hoods. The Type C enclosures provide effective operator protection from potential exposure to toxic powders, particulate, chemical fumes, and vapors. The AirSafe™ automatic safety controller constantly monitors airflow and filter conditions.
* HEPA/Carbon Ductless Polypropylene Balance Enclosure
* AirSafe™ automatic safety controller
* Horizontal laminar airflow pattern
* Chemically impervious construction
* Seamless design
* High mass - solid polypropylene construction
* HEPASafe™ filter change out
* Bonded carbon filtration
* Vapor-proof fluorescent lighting
* Optional dark blue base
* Optional disposal port for weighing containers
* No installation required
* Available in 36”, 48” and 72” widths
* 110V and 220V AC enclosure available
* Standard with fluorescent light and electrical cord access port (ACASLIP) slip hatch on each side |
|
MX-2000 Glovebox Atmospheric Chambers
Features:
- Wide choice of control capabilities
- Range of vacuum pumps
- Sturdy, rugged, modular design
- Optional programmable logic
- Optional single or dual-column gas purification units |
|
FEATURES
. Quiet operation, less than 50d(B)A and low power consumption.
. Portability of ductless fume cabinets enables their positioning in the optimum location, best for working and less walking around the laboratory thereby also substantially reducing risk from spillages etc.
. Filtration cabinets are safer for the environment, no pollution to the atmosphere, filters are removed and bagged for documented and accredited disposal.
. No ducting is required, therefore installation costs are kept to a minimum. |
|
BIGNEAT manufactures enclosures for containment of robotics systems, for OPERATOR protection (LAOP) or PRODUCT protection (LAPP).
For bio-hazard and bio-protection we offer several cabinet types. LABS cabinets offer both OPERATOR and PRODUCT protection at levels of sterility and protection for most drug discovery applications. For more sensitive, or more hazardous applications Bigneat manufactures cabinets to Class II design, providing protection to the essential requirements of BS EN12469:2000.
The need for these types of enclosure is increasing because of the demand in the Pharmaceutical industry for rapid throughput and reliability of biologically sensitive processes and associated bio-hazards - Bigneat is Europe's Number 1 supplier of Robotics and Laboratory Automation enclosures.
Typical applications include for cell culture, cell screening, drug discovery, gene assays, high-throughput screening, rapid microbiological detection systems.
Special features of Biological Cabinets:
. Ducted or recirculatory filtration models available
. Excellent access for maintenance and servicing
. Emergency stop control
. Lighting and UV lamps included
Options:
. Electrical sockets
. Used tips chute
. Leaded acrylic for radiochemistry applications |
|
BIGNEAT manufactures ducted or recirculatory cabinets for safe powder handling and weighing. These provide:
1. Excellent operator protection
2. Minimum maintenance
3. Stable 1 x 10-6g measurement
4. Excellent accessibility
The Range comprises XIT, XIT PLUS, EXCEL Safechange and EXCEL Plus cabinets and additionally we offer a bespoke fabrication service for your specialist applications.
Shown here XIT F3-XIT-S. |
|
PROTECTION OF THE HANDLING
with an H 14 HEPA filter and a filtration efficiency of 99.999 %, particles of 0.3 microns or more can be retained.
AN ERGONOMY OF QUALITY
The ergonomy of the working apertures is unique. It enables the protection of the handling while allowing the operator to have access to the entire surface of the enclosure.
AN INCREASED HANDLING COMFORT
The work surface features a rounded edge for comfortable positionning of the arms during handlings.
A GOOD VISION OF THE HANDLING
An inclined front door and transparent sides increase the operator's vision comfort. |
|
PROTECTION OF THE HANDLING
with an H 14 HEPA filter and a filtration efficiency of 99.999 %, particles of 0.3 microns or more can be retained.
AN ERGONOMY OF QUALITY
The ergonomy of the working apertures is unique. It enables the protection of the handling while allowing the operator to have access to the entire surface of the enclosure.
AN INCREASED HANDLING COMFORT
The work surface features a rounded edge for comfortable positionning of the arms during handlings.
A GOOD VISION OF THE HANDLING
An inclined front door and transparent sides increase the operator's vision comfort.
CORD TO STOP THE VENTILATION DURING THE WEIGHING |
|
| An isolator can be manufactured in two different modes: in rigid or flexible material. We have designed an isolator with mixed material (plexiglas and transparent pvc) in order to allow both resistance and flexibility. |
|
| ... products without technical information |
| |
MX-2000 Glovebox Atmospheric Chambers
Features:
- Wide choice of control capabilities
- Range of vacuum pumps
- Sturdy, rugged, modular design
- Optional programmable logic
- Optional single or dual-column gas purification units |
|
| ... products without technical information |
| |
|
|