Tripping current: 1,000 mA
Trigger voltage: 20 V - 28 V
... interlock (RES), selectable Synchronization of controllers Restart - Automatic Manual SILCL - 2, IEC/EN 62061 Performance Level (PL) - d, EN ISO 13849-1 MTTFd - 44 years, EN ISO 13849-1 PFHD - 4.5E-08 per ...
Tripping current: 1,000 mA
Trigger voltage: 20 V - 28 V
... interlock (RES), selectable Synchronization of controllers Restart - Automatic Manual SILCL - 2, IEC/EN 62061 Performance Level (PL) - d, EN ISO 13849-1 MTTFd - 38 years, EN ISO 13849-1 PFHD - 1.56E-08 per ...
Tripping current: 1,000 mA
Trigger voltage: 20 V - 28 V
... interlock (RES), selectable Synchronization of controllers Restart - Automatic Manual SILCL - 2, IEC/EN 62061 Performance Level (PL) - d, EN ISO 13849-1 MTTFd - 38 years, EN ISO 13849-1 PFHD - 1.56E-08 per ...
Tripping current: 4, 3, 2 A
Trigger voltage: 230, 24 V
... CM-ENE MIN belongs to the CM liquid level monitoring relay range. It operates with a rated control supply voltage of 110-130 V AC and has a 1 n/o output contact. It protects pumps against ...
ABB
... light grids? Is your application required to achieve Performance Level (PL) e of EN ISO 13849-1, Safety Integrity Level (SIL) CL claim limit 3 of IEC 62061? Do you need a safety relay ...
Tripping current: 6 A
Trigger voltage: 24, 230 V
The level sensor monitors filling levels or leakage of all conductive, noncombustible media. The trigger can be adjusted by means of a proportional potentiometer. As monitor, the device works with an ...
... environments and is built and tested to meet mission-critical IEEE and IEC protective relay standards. Apply the SEL-2414 to satisfy standalone or distributed monitoring and control of transformers, or ...
Trigger voltage: 24 V - 240 V
This Level monitoring relay is meant for monitoring the levels in contraptions like pools, well, tanks and reservoirs. This device lets the user choose ...
Tripping current: 16 A
Serves for level monitoring in wells, tanks, pools, reservoirsDESCRIPTIONWithin a single switch you can choose 3 configuration:One-state monitors one liquid level ( full or empty).Two-state ...
ELKO
Trigger voltage: 12 V
... green LED. • Output relay on (1-3), indicated by a red LED. • Power supply on (2-10), indicated by a yellow LED. • Supply rated voltage, indicated on the front of the relay. • Wiring scheme indicated ...
Trigger voltage: 12 V - 60 V
KRM169E - INSULATION RELAY FOR NON-GROUNDED LIVE DC MAINS Insulation relay for non-grounded live DC systems Self powered from any input from 12 to 60VDC Both for battery and power generated ...
Trigger voltage: 165 V - 255 V
Phase Failure and Liquid Level Relay (2in1) Features Liquid level control relays are designed to prevent the pumps which provide liquid transfer from tanks or wells ...
Tripping current: 35 mA
... controlled level- switching device up to 4 level probes + mass probe single level level regulation open-circuit recognition parameter change-over wide-range power supply ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining