The new rotary pallet detector VEGAPAL RN 3000 is adapted perfectly to the detection of level of the pulverulent or granulous solids starting from a density of 15 kg/m3.
Its very robust design with metal case IP66 and three stages of sealing make a detector made of it to last in contact with your process. It profits in fact of a 3 years guarantee.
Its implementation is very simple: unspecified position of assembly, rotary case for correct orientation of the EP, without adjustment, maintenance.
The exit signal is carried out on a free contact of potential 250 VAC/2A/500W. The power supply exists into 230,115,48 or 24VAC and 24 VDC. A version ATEX II ½ D for explosive zones 20 dust is available.
The typical applications are safety antidébordement and protection against the idle run on products such as cereals, flours, starch, dried milk, sweetens, sand, cement, granulated plastics, etc...
Applications:
- Detection of high, intermediate or low levels
- Non sticky powders and granulars (<10mm)
Advantages:
- No moving parts
- Large self cleaning single blade
- Easy to install
- Adjustable sensitivity
- Multiple probe lenghts
- Multiple products can be detected in the same silo
- Minimum material density : 0.03
- Maximum working pressure : 10 bars
- Die cast aluminium
- Especially suited for applications in fine grained and powdery bulk goods
- Simple and reliable function principle, maintenance free
- For difficult applications with high mechanical loading
- Short insertion length allows installation in very limited spaces, e.g. down pipes
- Favourable design to avoid build up between the forks
- Detection of solids in liquids
- Robust die-cast aluminium housing
- Enclosure IP 66
- Certified for hazardous locations (gas and dust)
Unlike dynamic level detectors, float switches are mainly used to sense a static (e.g. maximum or minimum) level of liquid within a tank. The signal is actuated by either a magnetic (contactless) or electric sensor. For safety reasons, contactless magnetic sensors are often used with dangerous (e.g. explosive) media.
However, floats can also be used in purely mechanic devices known as "float valves" to open or close an inlet in relation to a certain fluid level.
All our floats for float switches are made according entirely to your individual specifications, e.g. with mounting rod, threaded or hinged mounting bracket etc.
Type, size and material of the float are subject to customers' requirements and the nature of the task