Volume Mapping PIV
An integrated solution for mappings in cross-sections of a flow
The Volume Mapping Solution delivers multiple 3D stereoscopic PIV mappings in cross-sections of a flow within a very short time interval, while the integrated software solution controls all PIV system elements and the traverse mechanism.
|
|
SPRESCAN BTWS is a laser-based board thickness and width measuring system for transversal and longitudinal conveying. The system consists of a control computer and a pair of sensors.
The sensors , which are located above and beneath the board, are linked to the control computer and consist of two measuring heads each. They operate according to the triangulation method and they are distinguished by utmost accuracy.
|
|
|
Automatic identification not only includes the question: "Who am I?" but also: "What do I look like?" SICK's laser measurement systems have the answer to this question. Determination of the shape and loading state of a pallet, or the height of a vehicle before entering the Gotthard Tunnel, controlling robots for the automatic loading of flight baggage, or monitoring the tracks ahead of autonomous goods wagons - laser measurement systems from SICK provide all the necessary information.
|
|
|
As automated processes are increasing in number and steadily being integrated into new industrial areas, the requirements for industrial sensors are also increasing. Special attention lies on quality, reliability and availability. Our industrial-use sensors are designed to allow easy integrability, but also to provide a maximum in productivity. Equipped with standard interfaces, they may conveniently be integrated into manufacturing lines or host systems.
|
|
Characteristics
Position sensing (also of moving targets) up to a distance of 240 m. With reflector.
Type LE-200
Measuring range 0,2 - 240 m
Resolution (max.) programmable 0,1 mm
Accuracy (typ.) +/- 2 mm
Reproducibility (max.) /- 2 mm
Characteristics
Position sensing of quasi-static targets without reflector up to a distance of 65 m, with reflector up to 500 m
Type LLB-60 D
Measuring range
0,05 - 65 m without reflector
0,05 - 500 m with reflector
Resolution (max.) programmable 0,1 mm
Accuracy (typ.) /- 1,5 mm or /- 3,0 mm according to device type
|
|
Prism Units
1 P Tilt Unit A
(MPU 5A) Prism Constant -30
(MPU 05A) Prism Constant 0
3 P Unit A
(MPU 7A) Prism Constant -30
3 P Shift Type A
(MPU 8A) Prism Constant -30
|
|
Model 9MP
Road counter usable on a great variety of surfaces.
Telescopic adjustable handle.
Blister Pack.
Max. Length: 9.999,9 m.
Weight: 0,6 Kg
|
|
Professional and robust road measuring wheel with built in stand and brake. The wheel is available in metric or imperial versions and is ideal for any distance measuring application.
Features:
• Large easy to read display.
• Pointer indicates start position.
• Robust construction.
• 2 Year guarantee.
• Fold away stand.
• Folding, locking handle for easy carriage.
• Adds forward subtracts in reverse.
• Measures up to 99999.9metres, yards or 99999'11feet and inches.
• Accuracy ± 1%.
• Shipping weight 3Kgs
|
|
| ... products without technical information |
| |
|
Agilent LCR and resistance meters are useful in testing components and materials in a variety of research and design applications and in component manufacturing. LCR meters measure impedance (inductance, capacitance, and resistance) at spot frequencies. Resistance meters are optimized for high-resistance or low-resistance measurements.
|
|
|
The B&K Precision Model 889B Synthesized In-Circuit LCR/ESR Meter with Component Tester is a high accuracy test instrument used for measuring inductors, capacitors and resistors with a basic accuracy of 0.1%. Also, with the built-in functions of DC/AC Voltage measurements and Diode/Audible Continuity checks, the Model 889B can not only help engineers and students to understand the characteristic of electronics components but also being an essential tool on any service bench.
|
|
Measuring Instrument - LCR Precision Instruments ( LCR200) :
Key Features:
- Measurement Parameters : Z , Ls , Lp , Cs , Cp ,
DCR , ESR , D , Q , and (Theta)
- Test conditions : 100MHz , 120Hz , 1KHz , 10KHz , 100KHz , 200KHz ; 1Vrms , 250mVrms , 50mVrms , 1Vdc(DCR only)
- DMM Functionalities
- Dual LCD Display with LED backlit
- Open / Short calibration
- Remote binning capability
- Auto range / range hold selection
|
|
|
|
|
|
Product ID: LCR-612
20000 Counts Hand Held LCR Meter Dual Display Auto-Ranging ( LCR-612 )
20000 Counts LCR Meter
Dual Display Auto-Ranging
MODEL: LCR-612
Outstanding Features:
1.Basic accuracy:
0.5% for Resistance
0.7% for Inductance, Capacitance
2.Dual Displays provide quick tested results readouts, with L.C.R. Display values up to 19999 counts and Q.D.R. display values up to 9999 counts
3.Excellent resolutions:
Resistance up to 0.001Ù
Inductance Capacitance up to 0.1uH/0.1pF
4.Provided up to 4 testing parameters:
Ls+(Q,D,Rs), Lp+(Q,D,Rp)
Cs+(Q,D,Rs), Cp+(Q,D,Rp)
5. Auto-Power Off function:
To conserve battery life for longer use.
6.Fuse detection function:
To inform that the fuse is open or damaged.
7.External DC Adapter functions:
Use of a DC adapter can also serve to disable Auto Power Off function.
Dual Display LCR Meter LCR-612 Test Ranges: 120Hz and 1KH
LCR-612 SPECIFICATIONS
LCR-612 Display:
LCR—4 1/2 digits, maximum reading of 19999.
QDR—4 digits, maximum reading of 9999. (Auto range).
Parameter Measurement:
Ls+(Q,D,Rs), Lp+(Q,D,Rp)
Cs+(Q,D,Rs), Cp+(Q,D,Rp)
Overload: "OL" is display.
Test Frequency: 1KHz and 120Hz.
Range Mode: Auto and Manual.
Auto Power Off:
The meter key switch inactive for more than 5 minutes, press power key to resume operation.
Measurement rate: Approx. 1 time per second, nominal.
Power Requirement: (1). Single standard 9-volt battery.
(NEDA 1604, IEC 6F22 006P) ;(2). External DC Adapter 12Vmim to 15Vmax / 50mA.(optional)
Overload Protection: 0.1A/250V fast below fuse.
Dimensions:192mm(H) x 91mm(W) x 52.5mm(D).
Weight: 365g. (including accessories)
|
|
|
The LCR Meter measure passive components with as little as 0.05 % error. These easy-to-use instruments are quick to setup, adjust and calibrate. The SR715 and SR720 are ideal for applications such as incoming inspection, quality control, automated test, and general benchtop use.
|
|
High-speed LCR meter with up to 120MHz sampling
High Speed Testing of Chip Inductors and Magnetic Heads in Research and Development
Broad Frequency Measurement Range ( 100 kHz to 120 MHz )
High speed LCR testing (6ms/sample)
14 Parameter Types ( |Z|, |Y|, Θ, Rp, Rs(ESR), G, X, B, Lp, Ls, Cp, Cs, D (tan δ) and Q )
Detachable Head Amp
Load Compensation Function
BIN ( Classification ) Measurement
|
|
1. 320x240 dot-matrix display
2. Test frequency range : 20Hz - 1 MHz
3. Measurement parameter |Z|, Rs, Rp,Xs, Rdc|, |Y|, Gp,
Bp, Ls, Lp, Cs, Cp, D, Q , Theta
4. Basic Accuracy ± 0.1%
5. Measurement Time : 30 mS ( Fast )
6. Bin Function : 8 bins (expandable to 15 bins)
7. Comparator function: Primary / Secondary
8. Memory : 256 instrument setups
9. External Memory interface (Option)
10. Interface : Handler,( Option : GPIB, RS232 ,Printer )
11. Deviation Zero : Open / Short
12. DC Bias (Option)
|
|
- LCD Display 128 x 64
- File Management ( Flash Memory Card)
- Test Point Range : 64-2048
- Test Voltage : 50-1500VDC (RT-9651 H / CH )
- Insulation Test : 500K-1000MOhm(RT- 9651H/ CH)
- 4-Wire Rsistance Test : Yes
- Components Test : Resistor,Diode,Capacitor(Option)
- Resistor Measurement : 0.1Ohm-20MOhm
- Capacitor Measurement : 100pF-1000uF
- High Quality Relay
|
|
| ... products without technical information |
| |
|
|