One high accuracy multi-range sensor measures four parameters (Conductivity, TDS, Salinity and Temperature)
* Autoranging meter offers 3 ranges to measure from pure water to salinity solution to waste, boiler and cooling water using the same conductivity cel
* 6 selectable units of measure:
µS, mS, ppm, ppt, mg/L, and g/L
* Internal memory stores up to 15 labeled readings for easy recall
* Adjustable Conductivity to TDS ratio factor from 0.4 to 1.0
* Self calibration on power up |
|
Four-digit display for full 9999 readings with autoranging capability up to 200 ppt/200 mS
Powerful microprocessor-based surface-mount circuitry
Display prompts for simple pH calibration
Real Time Clock
Memory for 100 readings with Date & Time Stamp
Factory-calibrated with NIST traceable solutions, each PoolPro may be supplied with both certification of traceability & NIST traceable solutions for definitive calibration
pH/ORP Sensor protective cap
Fully automatic temperature compensation
Auto-shutoff maximizes the life of the single 9V battery to more than 100 hours/5000 tests
Non-volatile microprocessor provides data back-up, even when the battery is changed; this assures all calibrations and memory data are retained
Extended life pH/ORP sensor is user-replaceable in the field |
|
The total TDS is a mass estimate and is dependent on the mix of chemical species as well as the concentration while conductivity is only dependent on the concentration of chemical species. Some applications require the measurement of Total Dissolved Solids (TDS) in mg/L, parts per million (ppm) or parts per thousand (ppt). The TDS concentration can be obtained by multiplying the conductivity
value with a factor which is empirically determined. Eutech offers meters that allow the direct reading
of TDS values. These include the TDSTestr series, EcoScan TDS 6, CyberScan Standard Portables CON 11, CON 110 and Waterproof Portable CON 410. Bench meters for advanced level laboratory research are the CyberScan CON 510, CON 1500 and colour touchscreen research-grade CON 6000. |
|
Features:
- Rugged design for handheld or bench top use, neckstrap for "hands-free" operation.
- Large 3-1/2 digit LCD built into adjustable "flip-up" cover.
- Wide measuring range from 10 to 19,990 uS/cm for conductivity or 10 to 19,990 ppm for TDS.
- Calibrate for changes in cell constants via a cell adjust. |
|
The system: for pH, cond. and O2 - reliable, flexible, simpler than ever
High Quality Digital - HQD-meter
means complete, coordinated, stable meters with practical accessories and intelligent electrodes. What makes HQD special is the newly developed INTELLICAL electrodes, which store all relevant characteristic parameters in digital form.
- Digital INTELLICAL electrodes and metes are interchargeable (Mix Match principle).
- Digital INTELLICAL electrodes are recognised automatically.
- The calibration data is stored in the INTELLICAL electrodes, and the control intervals can be programmed to enable application - specific status checks.
- All INTELLICAL electrodes with integrated temperature sensor.
|
|
- Multiparameter measurements
- Quick calibration in each mode
- 2 sensor inputs (pH and conductivity/dissolved oxygen)
- 199 results stored
-You can read your results at a glance on the large backlit LCD.
-Store your results automatically with the date and time.
-Follow a user-friendly icon-based menu.
-Use colour-coded bottles for error-free calibration.
-Give your electrodes a new lease of life with a single click thanks to the cartridge concept.
-Built-in RS232 connection to document and archive measurements results onto a PC
|
|
The inoLab® benchtop meters of WTW, Weilheim, Germany, have been relaunched in April 2004. Now, an appropriate meter is available for almost every application :
1) Easy-to-operate, reliable, with big, bright display, battery or mains operated: inoLab® 720 series for pH/ORP, conductivity, dissolved oxygen (Multi 720).
2) Precise, communicative, with datalogger, memory, digital/analog RS 232 interface, printer (optional), GLP supporting: inoLab® 730 for pH/mV, dissolved oxygen, conductivity.
3) Enhanced methods for ISE measurement, menu-driven, backlit graphic display: inoLab® 735 pH/ION.
4) Communicative, high-performance, PC-controllable meters with enhanced possibilities like digital recorder or user administration: inoLab® 740 series, for all parameters, additionally BOD-measuring system.
5) Outstanding performance for special tasks in highly demanding applications: inoLab® pH/ION/Cond 750 with two high-impedance inputs, simultaneous measuring of three parameters (2 times pH or ISE or ORP and conductivity), PC-controllable, individual determination of conductivity temperature coefficients. Datalogger, memory, interface included. With user administration and password protection.
|
|
Every industrial, commercial or natural water source contains dissolved solids or salts. These impurities contribute to the scaling and corrosion of equipment, affect industrial and commercial processes and contribute to poor taste and other deficiencies in drinking water.
The redesigned TechPro IITM TP1 (formerly AR1 - TDS/COND/TEMP) and TPH1 (formerly ARH1 - TDS/COND/pH/Temp) models include greatly improved features and performance. Features to include advanced microelectronics, easy keypad calibration, memory and a waterproof enclosure |
|
Precise measurement is a product of the optimal interaction between electrode, calibration and meter. The obvious next step for us has been to develop meters to perfectly match our electrodes and buffer solutions. The result: The new Lab series of pH and conductivity meters from SCHOTT Instruments. These instruments are setting new standards for electrochemical measurement.
pH-meter Lab 850
The Lab 850, our “starter” model in the new series, comes with the advanced measuring algorithm specially adapted to SCHOTT Instruments’ electrodes. The result is a calibration and measurement in usual precision – but in a much shorter time!
pH-meter Lab 860 and conductivity meter Lab 960
Whether conventional via RS232 or modern via USB slave – both interfaces to the PC are integrated in the Lab 860 and Lab 960. No adapter is required.
pH–meter Lab 870 and conductivity meter Lab 970
The quality controller’s dream: A measuring instrument automatically recognizes the electrode! The new sensors with unique identification send their specific data to the measuring instrument … wireless! Thus the Lab 870 and Lab 970 always use the correct calibration for the identified sensor and help you to avoid errors in measurement. |
|
Thermo Fisher Scientific offers a comprehensive range of Russell pH electrodes and electrochemical sensors. The full range of products includes meters, electrodes and ancillaries for the measurement of pH, ORP, conductivity, dissolved oxygen and specific ions. Water test strips and kits complement the range of products for the potable water and environmental testing markets. Thermo Fisher Scientific is committed to providing the best instrumentation for a wide array of laboratory analyses.
|
|
Whether for testing in the laboratory, pilot plant or production, the YSI 7100 MBS is a powerful, upgradable Multiparameter Bioanalytical System with core features that make this platform a productivity tool for today and into the future.
The unit builds upon the accuracy and precision of YSI's proven sensor technology with improvements in efficiency, flexibility, and intelligence.
Capable of measuring six distinct parameters simultaneously, the system can be customized with up to three sensor modules-each containing up to two chemistry sensors. Existing chemistries include the following:
Glucose-Sucrose-Lactate-Glutamate-Glutamine-Ethanol-Methanol-Ammonium-Potassium-Galactose
|
|
The digital salt-meter, ES-421 employs a funnel-shaped sensor section ( conductivity ) , which measures the salt % of a sample ( dilute solution of soy sauce, ketchup,mayonnaise, Worcester sauce, sqeezed juice of pickles, etc. ) very small sample needed ( 1.0ml approx. is enough for measurement ) .
|
|
HEITOLAB MPC 350 Multiparameter:
- multiparameter with microprocessor. It ensures the continuous measurement of four parameters : pH, redox, conductivity, temperature
- one analog output 4 - 20 mA for each parameter and one RS 232 digital output.
- conductivity : 6 measuring ranges with automatic or manual range change: 200 mS, 20 mS, 2 mS, 200 µS, 20 µS, 2 µ S
- temperature compensation : automatic if a Pt 100 probe is plugged in |
|
WALL MOUNTING INSTRUMENTS
with one "ON or OFF" threshold and one output function 4 - 20 mA :
- pHM 200 : pH meter
- CM200 : conductivity-meter
- OXYM200 : oxymeter
- CLM200 : chlorometer |
|
| ... products without technical information |
| |
HFM 436 Lambda - Heat flow meter
With the HFM 436 Lambda, samples measuring 30 cm x 30 cm or 60 cm x 60 cm and of variable thicknesses ranging from a few millimeters to 10 (20) cm are tested between two heat flux sensors in fixed or adjustable temperature gradients. After a few minutes for the system to reach equilibrium, the built-in PC or external computer determines the thermal conductivity and thermal resistance of the sample.
Automatic plate movement and determination of the sample thickness simplify test preparation.
All test parameters as well as the calibration data are stored in the PC and documented.
Determination of thermal conductivity with the HFM 436 Lambda meets the industry standards ASTM C 518, ISO 8301, JIS A 1412, DIN EN 12939, DIN EN 13163 and DIN EN 12667. |
|
|
|