Portable Particle Counting System for Oil and Hydraulic Fluid
PAMAS S40
- 8 channel high resolution digital system for analysis
- According to ISO 4406:1999 4µm(c), 6µm(c), 14µm(c) based on ISO 11171:1999 calibration
- According to ISO 4406:1987 (2µm), 5µm, 15µm based on ISO 4402 calibration
- Pressureless sampling as well as pressurized up to 420 bar (6000 psi)
- User friendly operation using touch screen with graphic display
- Compatible with ISO 4406:1999, SAE AS 4059D, ISO 4406:1987, NAS 1638
- Real portability with lab system accuracy
- User can configure the system to their needs in profiles
- Pressurized sensor avoids degassing
- Display and printout provide triple ISO codes, NAS- and SAE cleanliness classes, measurement volumes and particle numbers
- Highest repeatability and accuracy
- Password protected user levels
- Storage of more than 500 measurement data sets
- Built in battery for data backup
- Viscosity independent up to 200 cSt
- Pressurized sampling up to 350 cSt
- Minimess M16x2 and standard connectors (DIN ISO 2353) or user specific
- Operates on 90 - 230 V AC (50/60 Hz), 12 - 30 V DC or internal battery
|
|
Parker's IQ200 particle counter is specifically designed to provide continuous, on-line monitoring of the particulate contamination level of hydraulic and lubrication fluids. This compact, affordable particle counter can connect to virtually any system to give the user real-time data at the specified interval. Other features include:
• Remote and multiple system monitoring from one location
• Completely automatic
• Laser accuracy and repeatability
• Programmable test intervals from 3 seconds to 24 hours
• Adjustable contamination level alarms
• Integral flow and calibration check
• ISO 4406-1999 reporting format (4, 6, 14 micron) and correlation to NAS 1638
• User friendly Windows-based software
• Data displayed instantly in chronological or graphic form
|
|
|
|
|
|
· Rugged portable unit for quick and simple particle
analysis on site
· Simple menu-driven operation
· Laser sensor with 12 channels for exact and reproducible
results
· Possibility of suction and pressure side operation
· Integrated suction pump with new system. Flow
regulation independent from viscosity and pressure
· Prior to each measurement automatic flushing of
the gauge head
· Adjustable measuring mode (single and cyclic
measurements
· Long term measurements up to 330 hours
· Memory bank for 1400 measurement values (up to
99 series).
· Calibration according to ISO 11171:1999 (NIST)
· Analysis according to ISO 4406:1999
Analysis according to ISO 4406:1987
Class 1 up to 24
· Analysis according to NAS 1638
Class 0 up to 12
· Measuring range ISO 4402: 2 - 100 µm
Measuring range ISO 11171: 4 - 50 µm
· Indication of the absolute numbers of particles in all
channels
· Serial interface for further data processing via PC
· Integrated printer
· Threshold function contact for preset min. and
max. classes
|
|
Precision optics and advanced electronics make Chemtrac Particle Counters perform with unparalleled accuracy. Chemtrac's patented sensor flow cell is externally mounted to eliminate any possibility of water damage to counter electronics. A constant head, flow controller with low flow alarm provides a simple, reliable, sample system. The PC 2400 D communicates digitally using a nonproprietary serial interface which emulates the Optomux Opto 22 protocol. Ninety six (96) counters can be multi-dropped on a single RS485 serial communications loop up to 4,000 feet
BENEFITS
- Optimize Crypto and Giardia removal
- Provides Particle Size & Quantity Information
- Immediate Response To Process Changes
- Maintain High Quality Finished Water
- Optimize Filter Backwash
- Improve Filter Performance
- External Sensor Simplifies Sensor Maintenance
- Network or Stand-alone Operation
|
|
General description:
Portable system for the measurement of particle number and size in liquids and super-viscose media. The available sensors include a measuring range of less than 1 µm - 150 µm. It is possible to measure directly at pressure pipes up to 10 bar (optional 315 bar). Results are shown immediately on the LCD screen. For additional data processing there is also the Log and Show 3.1 (water) or 3.2 (Oil) evaluation software available.
The protocol printer integrated in the device provides printout of measuring sequences and sensor response lines.
The measuring system is available in either the oil or water version.
Optional DPS-1 pump system: self-priming pump for measuring volumes of more than 10 ml.
|
|
One high accuracy multi-range sensor measures four parameters (Conductivity, TDS, Salinity and Temperature)
* Autoranging meter offers 3 ranges to measure from pure water to salinity solution to waste, boiler and cooling water using the same conductivity cel
* 6 selectable units of measure:
µS, mS, ppm, ppt, mg/L, and g/L
* Internal memory stores up to 15 labeled readings for easy recall
* Adjustable Conductivity to TDS ratio factor from 0.4 to 1.0
* Self calibration on power up
|
|
|
|
|
|
Micro Processor Base Salinity Meter ( SM-850)
Model SM-850 Features:
_Portability and simplicity one-hand operation
_Dual display Salinity and Temperature
_Automatic Temperature Compensation
_Average calculation, interval measuring, gram-conversion
_Use highly accurate NTC temperature sensor
_Auto power off function
_CE-Mark approval
Specifications:
Low battery indication: The "Battery symbol " is displayed when the
battery voltage drops below the operating level.
Operating environment: 0 C to 50C, <75% R.H..
Storage environment: -20C to 60 C, 0 to 80% R.H.
with battery removed from meter.
Accuracy: Stated accuracy at 23 C +/- 5 C, <75% R.H..
Dimensions: 167mm(H) x 48mm(W) x 24mm(D).
Weight: Approx. 330g. (including probe and battery)
Temperature:
Sensor: Thermistor temperature sensor
Range: -20 C to 60C, -4 F to 140F
Resolution: 0.1 C / 0.1 F
Accuracy: +/-0.5 C ,0 C to 45 C;
+/-1 °C -20 C to 0 C, 45 C to 60 C;
+/-1 F : 32 F to 113F
+/- 2 F:-4 F to 32 F, 113 F to 140 F
Relative Salinity:
Relative Salinity:
Range: 0.1% to 10%
Temperature compensation: -5 C to 60C, Automatic Accuracy:
0% to 0.9% (+/- 0.1)
1.0% to 1.9% (+/- 0.2)
2.0% to 2.9% (+/- 0.3)
3.0% to 4.9% (+/- 0.5)
5.0% to 7.9% (+/- 1.0)
8.0% to 10.0% (+/-1.5, depend on the way of measuring)
Applications:
Water monitoring, Liquid Foods, Beverage
|
|
|
|
|
|
Near-Infrared, Non-Invasive Tissue Oximeter
OxiplexTS is a revolutionary new device allowing the measurement of oxygenated and de-oxygenated hemoglobin concentrations in tissue. The device works by emitting Near Infrared (NIR) light into tissue at known distances from a collector. Light of two different wavelengths is used and the light is modulated at an RF frequency of 110 MHz. The collected light is measured and processed, and the absorption and scattering coefficients of the medium are determined. Once the absorption and scattering are determined, the assumption that hemoglobin is the only significant absorber is applied and the oxygenated and de-oxygenated hemoglobin concentrations are calculated.
The unique feature of the ISS OxiplexTS is that it uses the theory of photon migration through highly scattering media. This patented technology allows for the first time the absolute measurement of absorption and scattering in a highly scattering medium such as human tissue.
Since OxiplexTS measures the absorption and scattering of tissues directly, it does not require any calibration, estimation, or assumption about scattering in order to make an accurate measurement of absorption and, hence, hemoglobin concentrations. This unique ability to separate scattering from absorption sets the ISS OxiplexTS above all other NIR tissue oximeter technologies.
|
|
The total TDS is a mass estimate and is dependent on the mix of chemical species as well as the concentration while conductivity is only dependent on the concentration of chemical species. Some applications require the measurement of Total Dissolved Solids (TDS) in mg/L, parts per million (ppm) or parts per thousand (ppt). The TDS concentration can be obtained by multiplying the conductivity
value with a factor which is empirically determined. Eutech offers meters that allow the direct reading
of TDS values. These include the TDSTestr series, EcoScan TDS 6, CyberScan Standard Portables CON 11, CON 110 and Waterproof Portable CON 410. Bench meters for advanced level laboratory research are the CyberScan CON 510, CON 1500 and colour touchscreen research-grade CON 6000.
|
|
Four-digit display for full 9999 readings with autoranging capability up to 200 ppt/200 mS
Powerful microprocessor-based surface-mount circuitry
Display prompts for simple pH calibration
Real Time Clock
Memory for 100 readings with Date & Time Stamp
Factory-calibrated with NIST traceable solutions, each PoolPro may be supplied with both certification of traceability & NIST traceable solutions for definitive calibration
pH/ORP Sensor protective cap
Fully automatic temperature compensation
Auto-shutoff maximizes the life of the single 9V battery to more than 100 hours/5000 tests
Non-volatile microprocessor provides data back-up, even when the battery is changed; this assures all calibrations and memory data are retained
Extended life pH/ORP sensor is user-replaceable in the field
|
|
Features:
- Rugged design for handheld or bench top use, neckstrap for "hands-free" operation.
- Large 3-1/2 digit LCD built into adjustable "flip-up" cover.
- Wide measuring range from 10 to 19,990 uS/cm for conductivity or 10 to 19,990 ppm for TDS.
- Calibrate for changes in cell constants via a cell adjust.
|
|
|
|
|
|
CarboQC
CarboQC is a dissolved carbonation meter and gives you fast, accurate and reliable determination of carbon dioxide in beverages. If combined with the PFD Filling Device, sample is taken directly from the package into the measuring chamber of CarboQC - with no loss of any carbon dioxide during sample transfer.
Accurate and traceable CO2 measurement
* One instrument suitable for lab and at-line applications
* No influence of dissolved air (oxygen and nitrogen)
* Highly accurate absolute pressure sensor, no weather and sea level influence
* No adjustment with CO2 standards necessary
* Suitable for pressures of up to 10 bar (145 psi)
High-quality performance
* Simple and easy operation
* Data memory for 99 measurements
* Battery stack quickly rechargeable for flexible operation
* Two RS-232 interfaces for transferring measuring results to a printer or PC
* Filling, rinsing and measuring by pressing only one button
* Splash-proof, lightweight plastic housing
* Minimum bench space required
Fast and easy handling directly from the package - no degassing required!
* Combination with DMA 4100/4500/5000 for simultaneous determination of the CO2 content and density/Brix (PBA-S)
* Combination with Soft Drink Analyzer 2P for additional determination of Brix actual/Brix fresh/degree of inversion (PBA-SI)
* Combination with DMA 4500/5000 and Alcolyzer Plus Beer for additional determination of the alcohol content (PBA-B)
|
|
Membrane covered galvanic
oxygen sensor
• Temperature compensation
• Up to 6 months usage of membrane
• High signal resolution
• Rapid response
• Waterproof sensor (IP 68 – 2 bar)
• Incl. calibration vessel OxiCal®-SL
• Membrane leakage monitoring
|
|
|
|
|
|
Model HPM 4/6 portable vacuum meters are compact, hand-held, digital display, battery operated control units. When combined with the Hastings Instruments rugged thermopile sensors, they become vacuum instruments designed for portability and ease of use in applications where AC power is not readily available.
The lightweight control units operate with a standard 9 volt battery, and are available for display in units of Torr or mbar. Additionally, they can be calibrated to an individual sensor or set for average sensor output to test many different sensors of the same type. They are switchable to offer display for both the DV-6 (0.001 to 1 Torr) and the DV-4 (0.01 to 20 Torr) sensors without re-calibrating. These sensors are rugged, noble metal sensors which are resistant to corrosion and can be ordered with a variety of system connections to meet your system's requirements such as VCR(R), KF 16, KF 25, Glass, MiniConflat™, etc.
VCR is a registered trademark of Cajon Company.
MiniConflat is a trademark of Varian Associates, Inc.
|
|
Optical DO sensor without calibration nor maintenance.
Thanks to its Modbus RS485 output, this sensor is able to be connected directly to automates, datloggers or remote systems.
Fields of application : Fishfarming, wastewater, natural water, seawater
|
|
|
ATI Model Q45D Dissolved Oxygen monitor provides reliable oxygen measurement and reduced maintenance costs. The galvanic dissolved oxygen sensor uses a rugged 5 mil Teflon membrane to resist mechanical abrasions and tears. The membrane serves as a barrier to allow molecular oxygen to diffuse into the reaction cell where it is reduced, producing a small current which is proportional to oxygen concentration. To keep the dissolved oxygen system nearly maintenance free, an optional Auto-Cleaner can be included to remove those materials that build up on the sensor membrane. The cleaning cycle is user selectable to maximize the cleaning effectiveness.
|
|
|
|
|
|
Developed to meet all field and laboratory requierements, the Digital ODEON instruments combine the versatility of an easy-to-use, easy-to-read handheld unit.
Rugged, reliable and IP-67 waterproof, the ODEON measures dissolved oxygen with the new ODO optical probe, pH,ORP, conductivity, temperature, and turbidity.
Thanks to PONSEL plug and play digital probes, autodiagnostic and calibration data inside, you just have a total confidence in your readings. just measure !
You need a simple and robust mono-parameter instrument, purchase a ODEON Classic with one ultra low power probe (pH/ORP/T, DO, Conductivity or Turbidity)
You need a versatile instrument ? Purchase a ODEON OPEN ONE ! Thanks to the Open Technology, your one channel system will accepte all PONSEL probe.
Your application require simultaneously parameters from 2 probes, purchase the ODEON X
Available:
ODEON Classic line
ODEON Open line
ODEON X Line
ALWAYS READY TO MEASURE : Digital plug and play probes
ALWAYS CONFIDENCE : Autodiagnostic, status always displayed, GLP compliance
SIMPLICITY : Huge display and intuitive menus
HIGH PERFORMANCES : Mono/Multiparameters - 8 Mo Memory (100 000 datas),
FIELD INTRUMENTATION : IP67
|
|
|
Measurements of dissolved oxygen (DO) in industrial processes serve to control the oxygen concentration, optimize the process and yield. Besides inline measurement the off- or near-line measurement system is often used for control at different sites with a compact portable transmitter/sensor system with data-logger, sampling device and interface to download stored measurement values.
|
|
HI 2300 performs EC, TDS (Total Dissolved Solids), percentage of NaCl and temperature measurements. The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample.
All measurements can be temperature compensated at 20 or 25°C and the compensation coefficient is selectable by the user. The automatic temperature compensation can also be disabled for measuring the actual conductivity value. The stability indicator on the LCD ensures accuracy.
Conductivity readings are performed by applying an alternate current to the 4-ring probe which creates a variable voltage directy proportional to conductivity.
The GLP feature allows users to store and recall data about system status.
|
|
|
|
|
|
Concentration measurement (System Aquasant-MT)
The concentration measuring system measures the product concentration of organic product mixtures with one variant, taking also in account the product temperature. Surveillance of chemical reactions directly in the production line (Determination of the end point).
Measuring principle: High resolution impedance measurement
Fast product temperature measuremnt
Adaptive automatic temperature linearization
Concentration measurement
digital (Relay output) pre-alarm/alarm
analog (0/4 - 20 mA) programmable
RS-232-interface and visualization software for parameterization, online data input or data evaluation from the memory
Self controlled measuring circuit
Hazardous area version
II (2) G [EEx ia] IIC ; SEE 99 ATEX 2469; CE 0499 EMV STS 024 CE
Sample of concentration measurements of organic mixtures with one variant
Ethyl alcohol (Ethanol) in 1-propanol
Ethyl alcohol (Ethanol) in toluene
Water content in isopropanol
Acetic anhydrid in acetic acid
0-1 % water in formic acid
15 - 20 % N-Bulitium in toluene
0-10 % ethyl alcohol (Ethanol) in demin. water 1-7 µS
|
|
|
|
|
|
Speedmax 400i
Speedmax® is an inline speed of sound measuring instrument for online determining of the concentration of liquid media. Speedmax® is especially suited for measuring dynamic processes in closed pipes of an automation environment. With the measured speed of sound and the temperature of the medium the current concentration of medium can be determined on basis of well known speed of sound curves.
Speedmax® is especially suited for quality assurance, to control continuous processes and min./max.limits in pipes. All parts having contact to the medium are PFA (New Teflon). Therefore Speedmax® can be used for very alkaline, very toxic and/or very aggressive media like concentrated acids and leaches. The measuring values of speed of sound and temperature are measured from outside through the measuring pipe. Process connections are free of seals using flare technology or NPT-screwing.
The design of the pipe minimizes dead volumes over the whole geometry. For output of measuring values a current output, limit outputs and a RS 485 interface are available.
|
|
|
|
|
|
Walchem’s WCU410 Copper Controller and WNI Nickel Controller are optoelectronic on-line analyzers that measure the actual concentration of copper or nickel in solution. They are used in a variety of applications including electroless plating baths and microeth baths (including oxide-replacement types).
The WCU410 may be switched from electroless copper to microetch via the menu, eliminating the need for a second controller. It reduces the need for manual titration, improves yield, and in microetch applications improves productivity by reducing the frequency of bath change-outs.
The WNI410 is available as nickel-only, or with a pH control option which may be added in the field. Two separate pump outputs for nickel and reducer and another for pH are used, each of which is capable of totalizing either pump on-time, volume pumped, or metal turnovers.
Integrated datalogging is available to validate system performance. A USB memory stick is all that’s needed to extract data and event logs that include copper or nickel measurements, and relay status. Download logs from the USB stick to a PC at your convenience. It couldn’t be easier!
|
|
|
DO stands for Dissolved Oxygen, which is the measure of amount of gaseous oxygen dissolved in a solution. In theory, the amount of DO in a solution is dependent on 3 factors, namely temperature, salinity and atmospheric pressure. The measurement of DO requires a special DO electrode that is made up of an anode, a cathode, electrolyte solution and a gas permeable membrane.
|
|
Hach LDO™
Since 2002, Hach has established itself as the premier provider of Luminescent Dissolved Oxygen technology, and only Hydrolab Series 5 sondes feature Hach LDO technology – designed, manufactured, and supported by Hach in Loveland, Colorado.
Features:
- No membranes
- Calibrations that last
- Superior accuracy
- Compact housing allow complete integration into any sonde – DS5X, DS5, or even MS5
Benefits:
- Calibrations that last without drift means that deployments will last longer, reducing frequency of trips to the field for maintenance, saving you time and money
- No membranes so concerns about air bubbles, 24-hour membrane relaxation, and the art of maintenance are a thing of the past
- Does not consume oxygen so passive fouling will not affect DO readings
- Best accuracy because solid, defendable data is the ultimate goal
- Designed, manufactured, and supported by Hach Environmental, the experts in LDO technology, so all your questions can be addressed locally
|
|
These analyzers and sensor and mounting accessories are suitable for dissolved-oxygen measurement in the ppm range typically found in waste treatment applications. They ensure effective aeration and regulatory compliance.
Benefits:
- Rugged sensor delivers long reliable life
- Ball float, hand rail and swivel accessories provide convenient installation
- Membrane service kit provides cost-effective maintenance option
- Dual sensor input capability
|
|
Model B-310 uses a unique galvanic sensor to read 0-20.0 ppm dissolved oxygen in aqueous solutions and 0-100% oxygen in air.
Galvanic sensor is totally sealed requiring no membrane or replacement filling solutions. Temperature compensated to maintain accuracy for air calibration. Requires only 0.5 ft./second flow rate for acccurate readings. Sensor withstands 25 psi (60 ft. depth in water).
Digital display meter comes complete with 9- volt battery, galvanic sensor with 5 foot cable, carrying case and instructions. Custom sensor cable lengths available up to 100 feet. Optional Oxan Extender Kit extends the life of the B-310 sensor.
|
|
Measurement and control instrument for dissolved oxygen
- Easy and safe operation by plain text menu guidance
- Safety by password function
description
The K 100 (W) O2 is a sophisticated single-channel instrument for measuring and control dissolved oxygen. Additionaly temperature measurement of the measuring media is possible. The instrument is available in a panel mounted housing (K100 O2) and in a wall mounted housing (K 100 W O2).
applications
|
|
Orion 3-Star Plus Benchtop Dissolved Oxygen Meter
- Improved stability algorithm to increase calibration and measurement accuracy
- Average slope and slope of segment printed with measurement
- Ability for ATC temperature calibration
- Increased data log points: 1000
- Ability to turn off data log
- Ability to print or view last 10 calibrations
- New Individual method passwords
- Now with ability to operate an auto-sampler!
- Ability to turn off BOD stirrer
- Solution and membrane temperature printed with measurement
- Solution and membrane temperature displayed
- Ability to calibrate both solution and membrane temperature
- DO slope now on printout
|
|
Features:
- Microprocessor based design with large LCD displays Conductivity or TDS or Salinity and Temperature simultaneously..
- Rugged design with splash proof housing for handheld or bench top use, neckstrap for ¡°hands-free¡± operation.
- Automatic Temperature Compensation(ATC) and degree ¡æ/¨H switchable.
- Simple to calibrate by one button, 3 ranges of standardizing solution are necessary for the automatic calibration recognition procedure.
- Memory function stores and recalls up to 25 points. MAX/MIN and data Hold.
- Low battery and consumption indicator. Auto shut off after 10 minutes of non use, but except status at MAX/MIN mode.
|
|
The dissolved oxygen analyzer, model 7118, is used for online measurement of dissolved oxygen concentration in the condensate, feed water, etc., of thermal or nuclear power plants. As membrane electrodes are used to measure dissolved oxygen, the analyzer can be used in a closed-loop system without contaminating the samples.
* Provided with an automatic calibration function
* Membrane polarographic electrodes are used.
* Quick response
* A wide selection of ranges is available.
|
|
|
|