PerkinElmer recently acquired Arnel, a recognized leader in engineered solutions for GC applications in the hydrocarbon processing, food & beverage and industrial hygiene markets. PerkinElmer continues to provide standard and custom engineered solutions based upon the Clarus GC platform.
PerkinElmer offers more than 100 turnkey solutions with defined specifications that cover a wide range of applications and requirements in many industries – petroleum refining/petrochemical, natural gas and dissolved gases in transformer oils – providing superior analytical capabilities and ease-of-use.
And if our standard analyzers do not meet your needs, we can configure an analyzer to match your requirements.
|
|
With one of the most comprehensive families of sensors and on-line analyzers for pH, conductivity and dissolved oxygen, Yokogawa is recognized as a world leader in the field of analytical equipment.
|
|
The PowerMon Ionometer is a versatile applicable on-line measuring instrument, which is used for the monitoring of the legally prescribed limit value in the outlet of municipal and industrial purification plants.
Advantages:
-precise results
-connection of up to 100 external,
physical measuring sensors
-fully automatic operation
-easy, comfortable operation
-fast data transfer
-self-monitoring system
-remote maintenance and
network ability
-graphic user interface with interactive
Touch Screen operation
-update of the operating software or
download of data by USB stick
-minimum operating cost by small
reagent consumption
-second measuring point
without surcharge
-operation also possible
without housing
|
|
The Monitor 90 Ecometers are used to measure gaseous inorganic chorine, fluorine or ammonium compounds.
They are ideal for process monitoring and emission control, and comply
to the requirements of the German emission control regulations
(BImSchV) - among the strictest in the world. The high system availability makes the Ecometer an ideal component of automatic control systems for emission control installations.
Advantages:
-Minimal reagent consumption
for low operating costs
-Low maintenance, with selfchecking and automatic recalibration
-Automatic correction for
sample pressure and temperature
-Low sensitivity to interference,
below statutory requirements
-High stability, with low standard deviation and drift
-Industry standard interfaces and outputs
|
|
These analyzers and sensor assemblies are suitable for measuring fluoride concentration typically found in drinking water applications and are a simple, cost-effective solution for ensuring regulatory compliance in fluoridated drinking water.
Benefits:
- Low price
- Low maintenance
- No chemical additions
|
|
ANTEK's 9000F offers a cost-effective alternative to the common Wickbold method (oxy-hydrogen torch) of analysis, providing total fluoride determinations on gas, liquid, and solid samples safely within minutes instead of hours. It is far less expensive than ICP/MS; and, unlike other methods, the ANTEK 9000F is specific for fluoride without interference from other halides. The safe, non-hazardous ion specific detection method provides an analytical range from sub-ppm to percent levels.
Features & Benefits
- Specific for fluoride
- Sensitivity from sub-ppm to % levels
- Results in 5 to 15 minutes
- Non-hazardous operation
- Gas, LPG, liquid, and solid samples
|
|
| ... products without technical information |
| |
Gas Cylinder Store (Fire Protection)
90 minute fire protection conforms to DIN 4102, can be placed against a building without a safety gap
Gas cylinder store conforms to TRG 280
|
|
deposits for compressed gas cylinders
Fully hot-galvanized container for cylinder with swing doors, extra sturdy carryng frame
Available with or without base
Ready for anchoring to the floor
Split inside into lanes with safety chains
Suitable for storing cylinder pallets
Right or left door-opening option
Supplied assembled
|
|
PASSIVE SAFETY:
Construction doubles wall.
- External sheet steel Wall
- Interior Wall in H.P.L. (rolled-iron product high pressure)
Panels of thermo isolation enters the walls removing the cold bridges.
- Painting epoxy white RAL9010
- Indication by standardized symbols
- Not of fixing for earthing
ACTIVE SAFETY:
- Openings of ventilation with exit of ventilation diam.100mm for possible connection
- Ventilation shafts with thermofusible system allowing to isolate the interior of the cupboard in the event of fire.
- Joints of doors thermodilatants.
- Key Closing
- System of maintenance of the doors in position open with automatic closing preset to 50°C
OPTION:
All the models are delivered naked, US TO CONSULT for the racks, the vat of retention and the grating of the vat of retention.
|
|
|
|
|
|
CONFORMITY
Normalized labelling according to ISO 3864 and 92/58/CEE directive.
ADVANTAGES
Fire resistance during 15 minutes in accordance with ISO 834 fire heating curve.
PASSIVE SECURITY
Double wall construction :
- Outer housing made sheet of steel.
- Inner body made of H.P.L. coated sheet (high pressure laminated).
Thermal insulation panel between the walls avoiding thermal bridges.
Hight quality epoxy coating RAL 9010.
Large warning label.
Earthing link.
ACTIVE SECURITY
Air inlet and outlet channel in rear panel. Easy connection on the roof of the cabinet Ø 100 mm (labelled as exhaust channel).
In case of fire, a thermo-fuse automatically seals off the ventilation system.
Thermo-expanding seals of the doors allow keeping the internal body fireproof.
Separately locking door(s) with cylinders locks.
Self-closing doors with possibility to keep the doors open. If the temperature rises to 50°C, a fuse link closes the doors automatically.
ALL OUR MODELS ARE DELIVERED WITHOUT INTERNAL EQUIPMENTS. THEY ALL NEED TO EQUIPED WITH HORIZONTAL C-RAIL FOR FIXING GAS BOTTLES, ACCESS RAMP, ETC. SEE CHART.
|
|
| ... products without technical information |
| |
FLUXUS® G709 is an ultrasonic flowmeter for permanent installation in 19" rack systems.
In addition to the flow channels, FLUXUS® G709 can be equipped with up to 4 process inputs. With its wide range of electrical inputs and outputs, it can handle and process a great variety of process parameters.
The integrated flow calculator can perform a standard volume flow or mass flow correction according to ISO 12213-1. The connection of external process pressure and temperature measurements is needed for the calculation.
An extended status display helps the user to judge the measuring situation and current measuring precision directly during the measurement.
|
|
|
|
|
|
Clamp-on ultrasonic flowmeters
The SITRANS F US clamp-on ultrasonic flow technology offers several advantages, number one being the utilization of external transducers. These are quickly and easily mounted on the outside of the pipe, making them the perfect choice for retrofit applications and applications where corrosive, toxic or high pressure liquids and gases rule out the option of cutting the pipe.
With the use of the WideBeam technology, clamp-on flowmeters from Siemens have proven their superiority in both the field and the lab. They offer several benefits such as measurement of practically any liquid and gas; performance unaffected by viscosity, flow rate, pipe size, solids and aeration content; high accuracy and repeatability through automatic temperature compensation and zero drift correction; and installation flexibility on pipe sizes up to DN9140 (360 inches). They are available in six families: two geared towards general industry solutions and four tailored to energy, liquid hydrocarbon, gas and portable installations.
Combine this with flexible configuration options that allow you to either customize your flowmeter or to order complete systems, you can rest assured that we have the right solution for you.
|
|
|
GE Panametrics' GC868 flowmeter is a fixed-installation flowmeter comprised of the GC868 electronics, a pair of advanced clamp-on ultrasonic transducers, a clamping fixture, a preamplifier located near the transducers and coaxial cables to connect the transducers to the preamplifier and GC868 electronics. The DigitalFlow GC868 flowmeter can be used to measure the flow of any gas or steam.
|
|
Volume Flow Measuring System D-FL 200
Measuring system for ultra-sonic measuring of velocity and volume flow, especially for wet and aggressive smoke emissions (waste incineration).
Measuring system for ultra-sonic measuring of velocity and volume flow, especially for wet and aggressive smoke emissions (waste incineration)
Features
In-situ measuring method
Measurement possible below dew point and for high dust concentrations
Continuous measurement of normal volume flow and gas velocity
Automatic zero point and reference point control
Direct connection for temperature and pressure correction
Parameter input via keyboard or PC
Continuous temperature measuring
Applications
Volume flow measuring at low speeds
Plants with damp and/or aggressive exhaust gas, e.g. in waste incineration plants.
Volume flow measurement at high dust content
|
|
Minisonic G is an accurate and economical instrument for the instantaneous actual flowrate measurement of gas. The flowmeter accepts the PTZ corrector to obtain the normal flowrate. This ultrasonic instrument resolves all industrial needs.
In standard they offer :
• A display of flow and volume, of the direction and gas velocity,
• One 4-20mA output, 2 relays, 1 serial link, 1 software for PC.
It includes a very lastest electronic technology combined with highly digital signal porcessing technics and with more resources such as :
• echo analyser with automatic control (ESC mode : 'auto-focus' for the ultrasonic signals)
• zero offset adjustment for a reliable results
• high resolution time measurement < 0.1 ns
• an enhanced emission power
• a better noise rejection
• ergonomic keypad and menu calibration backlighted display
• possible to set a second 4-20 mA output
|
|
|
|
|
|
Portable ultrasonic flowmeter FLUXUS F601 is ideal for troubleshooting, plant optimisation and for control of permanent meters.
Features
* Wide application range thanks to the ability of the transmitter to work with shear wave AND lamb wave transducers at all frequencies
* A single pair of shear wave transducers fits a wide pipe diameter range
* Rapid installation without process interruption
* Bi-directional measurement
* High measurement dynamics
The FLUXUS ® G ultrasonic flowmeters use the proven "clamp-on" technology. The flow transducers are simply clamped onto the outside of the pipe. The measurement can hence be put into operation without cutting into the pipe and without production stop. The installation costs are low, retrofitting is not a problem.
Since the transducers are not in contact with the gas, there is no possibility of chemical attack. There are no moving mechanical or pressure loaded parts and thus no wear an tear. FLUXUS G is ideal for measurements at high pressures or on lines with pressure peaks.
Two transducer types for a uniquely wide application range
All FLUXUS® G transmitters support both lamb wave and shear wave transducers at all transducer frequencies. In this way the measuring system can be optimized to even the most demanding applications.
The Lamb wave transducers are ideal for measurement at high flow velocities, in natural gas pipelines for example, or at low pressures, amongst others in compressed air circuits. The shear wave transducers cover a wide range of pipe diameters and wall thicknesses. They are the best choice for mobile measurement or for high pressure systems.
|
|
| ... products without technical information |
| |
Digital alternative for a VA meter with totaliser and alarm functions.
MASS-VIEW(r) has an OLED display showing:
- actual flow rate (bar graph and actual value or percentage)
- desired flow units
- type of gas (7 pre-installed gases)
- totalized flow
- min. and/or max. alarm
Other features are:
- Freedom from parallax error
- Virtually independent of pressure and temperature variations
- Low pressure drop
- Wide flow ranges
- Fast response
- High accuracy
- Alarm and counter functions (2 alarm contacts available on meters)
- Analog (0..5 Vdc) and digital communication (Modbus-RTU, RS-232 interface)
- Configurable password protection
- 7 pre-installed gases available (Air, N2, O2, CO2, Ar, CH4, C3H8) or He or H2
- 4 selectable ranges (100%, 50%, 25% and 10% of maximum fullscale range)
- Digitally calibrated
- 3 year warranty
You can order these instruments online and your order is shipped within two working days.
|
|
|
|
|
|
Designed for low flowrates, AALBORG®'s Model P FLOW METER
is a precision instrument embodying the
simplicity, versatility and economy of the classical
Variable Area meter. It is particularly suitable
for metering carrier gases in chromatography,
indicating and controlling gases in manufacturing
processes, liquid and gas measurement in
laboratories, pilot plants, flow and level indicating, etc.
Shipped completely assembled, AALBORG®'s P METERS
include standard mounting fittings in a choice of
materials, side plates, thick protective magnifying
front shield and back plate, optional built-in control
valve, and flow tubes selected from the Flow
Capacities tables. Panel mounting style is convertible
to bench mounting through the use of the
optional acrylic tripod base. The tripod has a built-in
spirit leveler and leveling screws.
150 mm P METER is equipped with a CV™ Valve and the 65mm
P METER with an MFV™ Valve.
MATERIALS OF CONSTRUCTION
FLOW TUBES- Heavy-walled borosilicate glass.
FLOATS- Glass, Sapphire, 316 Stainless Steel,Carboloy and Tantalum.
STANDARD ACCURACY- ±2% FS (mm scales).±5% FS(direct readingscales).
CALIBRATED ACCURACY- ±1% FS
REPEATABILITY- ±0.25%.
USEFUL FLOW RANGE- 10:1 minimum with one float and better than 20:1 with combination of two floats installed.
|
|
KOFLOC RK120XM
The KOFLOC Precision Variable Area Flow Meter for Gas Mixing MODEL RK120XM SERIES combines 2 to 4 RK1200 precision flow-tubes optimized for gas mixing applications.The KOFLOC RK1200 SERIES High Precision Variable Area Flow Meter is a high-grade rotameter especially suited for measurement and control of minute flow, with an industry reputation of being one of the best analog devices. The KOFLOC 2412 SERIES Non-Rotating Precision Needle valve allows precise and easy flow control of minute amounts of gases and liquids. The internal mechanism converts rotating movement into stable linear movements with minimal vibrations. The needle and orifice has a thermal compensating structure (US P.A.F.) of 0.3%/˚C (15˚C to 35˚C).
FEATURES
♦ Wide-range flow measurement
♦ Fine control of minute flow
♦ Precision needle valve
♦ Numerous variants and custom models
APPLICATIONS
♦ Gas mixing
|
|
General description :
M 200 C Rotameters are gas flow meters that can regulate flow. They consist of a base plate, measuring tube holders, a dosing valve and a measuring tube. The size and type of the measuring tube varies according to the flow range and gas type.
The dosing valve is designed for accurate regulation of the desired gas flow which is read by means of the measuring tube.In order to ensure uninterrupted operation when dosing smaller amounts of gas (up to 25 g/h), additional filtration has been installed in the system.
Dosing valves are made of technically pure silver. Acicular fabrication ensures high precision of dosing.
Options
- M 200 C Rotameters cover a metering range of 12g/h to 115 kg/h,
- model M 240 up to 40 kg/h
- model M 250 up to 200 kg/h.
|
|
- Service: gases & liquids
- Wetted parts material:
Body- Acrylic Plastic
O-ring- NBR, Viton
Float- SS316, , Glass, POM Plastic
- Valve material: SS316
- Connecting material: SS316
- Connecting size: 1/8"NPT female
- Temperature & pressure limits:
150 pisg(10bar) @ 100ºF(38ºC)
- Temperature limit: -24ºC~+54ºC
- Accurary: 3% full scale
- Mounting: vertical position
- Weight: 0.12 kg
|
|
Features:
- Operating pressures up to 200 psig and maximum temperatures of 121ºC
- Feature fused ceramic scales accurate to within ±2% of full scale
- Repeatability is 0.25%
- Uniformly tapered bores with internal rib guides to stabilize the float
- Floats of glass, stainless steel or carbaloy
|
|
|
|