WALL MOUNTING INSTRUMENTS
with one "ON or OFF" threshold and one output function 4 - 20 mA :
- pHM 200 : pH meter
- CM200 : conductivity-meter
- OXYM200 : oxymeter
- CLM200 : chlorometer
|
|
Biochemical oxygen demand BOD determination is still one of the most important parameters in water resource management. It can be used to evaluate the impact of biodegradable substances in waters and waster water. With its OxiTop® systems, WTW offers a unique, modular and mercury-free instrument system. It is not only suitable for BOD determination, but also for measuring biodegradability and depletion.
In the course of growing environmental consciousness, microbiological degradability tests have become increasingly important. These can be, for example, soil surveys from waste sites or environmental impact surveys for new chemical substances. The necessary respiration measurements for anaerobic or aerobic degradation can be easily carried out using the OxiTop®-C systems with excellent analysis. WTW offers a wide range of application specific packages with appropriate sample vessels.
The advantages of OxiTop® and OxiTop® Control: simple operation, improved controllability and non-toxicity, and measuring ranges of up to 400 000 mg/l BOD (with OxiTop® Control OC 110). As the measured pressure is automatically converted the values can be directly read as mg/l BOD
|
|
The system: for pH, cond. and O2 - reliable, flexible, simpler than ever
High Quality Digital - HQD-meter
means complete, coordinated, stable meters with practical accessories and intelligent electrodes. What makes HQD special is the newly developed INTELLICAL electrodes, which store all relevant characteristic parameters in digital form.
- Digital INTELLICAL electrodes and metes are interchargeable (Mix Match principle).
- Digital INTELLICAL electrodes are recognised automatically.
- The calibration data is stored in the INTELLICAL electrodes, and the control intervals can be programmed to enable application - specific status checks.
- All INTELLICAL electrodes with integrated temperature sensor.
|
|
The inoLab® benchtop meters of WTW, Weilheim, Germany, have been relaunched in April 2004. Now, an appropriate meter is available for almost every application :
1) Easy-to-operate, reliable, with big, bright display, battery or mains operated: inoLab® 720 series for pH/ORP, conductivity, dissolved oxygen (Multi 720).
2) Precise, communicative, with datalogger, memory, digital/analog RS 232 interface, printer (optional), GLP supporting: inoLab® 730 for pH/mV, dissolved oxygen, conductivity.
3) Enhanced methods for ISE measurement, menu-driven, backlit graphic display: inoLab® 735 pH/ION.
4) Communicative, high-performance, PC-controllable meters with enhanced possibilities like digital recorder or user administration: inoLab® 740 series, for all parameters, additionally BOD-measuring system.
5) Outstanding performance for special tasks in highly demanding applications: inoLab® pH/ION/Cond 750 with two high-impedance inputs, simultaneous measuring of three parameters (2 times pH or ISE or ORP and conductivity), PC-controllable, individual determination of conductivity temperature coefficients. Datalogger, memory, interface included. With user administration and password protection.
|
|
Every industrial, commercial or natural water source contains dissolved solids or salts. These impurities contribute to the scaling and corrosion of equipment, affect industrial and commercial processes and contribute to poor taste and other deficiencies in drinking water.
The redesigned TechPro IITM TP1 (formerly AR1 - TDS/COND/TEMP) and TPH1 (formerly ARH1 - TDS/COND/pH/Temp) models include greatly improved features and performance. Features to include advanced microelectronics, easy keypad calibration, memory and a waterproof enclosure
|
|
Precise measurement is a product of the optimal interaction between electrode, calibration and meter. The obvious next step for us has been to develop meters to perfectly match our electrodes and buffer solutions. The result: The new Lab series of pH and conductivity meters from SCHOTT Instruments. These instruments are setting new standards for electrochemical measurement.
pH-meter Lab 850
The Lab 850, our “starter” model in the new series, comes with the advanced measuring algorithm specially adapted to SCHOTT Instruments’ electrodes. The result is a calibration and measurement in usual precision – but in a much shorter time!
pH-meter Lab 860 and conductivity meter Lab 960
Whether conventional via RS232 or modern via USB slave – both interfaces to the PC are integrated in the Lab 860 and Lab 960. No adapter is required.
pH–meter Lab 870 and conductivity meter Lab 970
The quality controller’s dream: A measuring instrument automatically recognizes the electrode! The new sensors with unique identification send their specific data to the measuring instrument … wireless! Thus the Lab 870 and Lab 970 always use the correct calibration for the identified sensor and help you to avoid errors in measurement.
|
|
WTW’s well-known „3xxi“ family of portable measuring instruments is available in four differrent product ranges:
1) For standard applications which do not require automated documentation nor extended sensor options, the 315i series is adequate. The customer can choose an instrument for either of the main standard electrochemical parameters pH/mV, DO and conductivity.
2) If special sensors (particularly such for conductivity measurement) or additional calibration procedures are to be employed, the 330i series instruments are a good choice.
3) Anybody seeking flexibility regarding the employment of sensors plus comfortable and reliable data transfer, will opt for the 340i series. This range includes not only single parameter instruments for pH, DO and conductivity, but as well combination instruments for pH/cond, pH/DO, and multiparameter (pH/DO/cond).
4) The multiparameter instrument Multi 350i takes in an outstanding position within the WTW range. By means of special sensors, this instrument can measure and store up to 3 parameters simultaneously.
|
|
pH, mV, ISE, Oxygen, Conductivity: The new Multi 350i can measure all of these parameters. If desired, pH, oxygen, conductivity and temperature can be measured simultaneously: In the Laboratory using the combined conductivity/oxygen sensor ConOx, in the field with the multiparameter probe MPP 350. All current WTW pH, combination ISE’s, oxygen and conductivity sensors can be additionally connected.
High resolution, high precision, simple, menu-driven operation. Even in poor lighting conditions the backlit graphics display provides clearly readable values. A datalogger, memory for 1,800 data sets and a real-time clock support GLP requirements.
Includes built-in NiMH rechargeable battery for up to 1,000 hours of continuous measurements and appropriate line adaptor.
|
|
- Multiparameter measurements
- Quick calibration in each mode
- 2 sensor inputs (pH and conductivity/dissolved oxygen)
- 199 results stored
-You can read your results at a glance on the large backlit LCD.
-Store your results automatically with the date and time.
-Follow a user-friendly icon-based menu.
-Use colour-coded bottles for error-free calibration.
-Give your electrodes a new lease of life with a single click thanks to the cartridge concept.
-Built-in RS232 connection to document and archive measurements results onto a PC
|
|
Thermo Fisher Scientific offers a comprehensive range of Russell pH electrodes and electrochemical sensors. The full range of products includes meters, electrodes and ancillaries for the measurement of pH, ORP, conductivity, dissolved oxygen and specific ions. Water test strips and kits complement the range of products for the potable water and environmental testing markets. Thermo Fisher Scientific is committed to providing the best instrumentation for a wide array of laboratory analyses.
|
|
Whether for testing in the laboratory, pilot plant or production, the YSI 7100 MBS is a powerful, upgradable Multiparameter Bioanalytical System with core features that make this platform a productivity tool for today and into the future.
The unit builds upon the accuracy and precision of YSI's proven sensor technology with improvements in efficiency, flexibility, and intelligence.
Capable of measuring six distinct parameters simultaneously, the system can be customized with up to three sensor modules-each containing up to two chemistry sensors. Existing chemistries include the following:
Glucose-Sucrose-Lactate-Glutamate-Glutamine-Ethanol-Methanol-Ammonium-Potassium-Galactose
|
|
|
Thermo Scientific's series of portable gas detection instruments use several types of detectors, including catalytic oxidation for hydrocarbon detection and electrochemical for toxic gases and oxygen. It should be noted that all detectors can experience extreme loss of sensitivity if exposed to certain materials (for instance, silicone for the catalytic detector). The instrument should always be checked if exposed to extreme concentration, suspected poisons, or contaminants.
|
|
HEITOLAB MPC 350 Multiparameter:
- multiparameter with microprocessor. It ensures the continuous measurement of four parameters : pH, redox, conductivity, temperature
- one analog output 4 - 20 mA for each parameter and one RS 232 digital output.
- conductivity : 6 measuring ranges with automatic or manual range change: 200 mS, 20 mS, 2 mS, 200 µS, 20 µS, 2 µ S
- temperature compensation : automatic if a Pt 100 probe is plugged in
|
|
The new CarboQC from Anton Paar is a portable, robust measuring instrument for the determination of dissolved CO2 in beverages. The analysis is based on the patented Multiple Volume Expansion method to eliminate the influence of other dissolved gases such as air or nitrogen. The instrument is highly accurate, simple to operate, requires low sample volumes and provides rapid results.
Be it soft drink production, brewing industry, mineral water production, wine or even sparkling wine production, the CarboQC allows the precise measurement of the CO2 content in less than two minutes.
|
|
Four-digit display for full 9999 readings with autoranging capability up to 200 ppt/200 mS
Powerful microprocessor-based surface-mount circuitry
Display prompts for simple pH calibration
Real Time Clock
Memory for 100 readings with Date & Time Stamp
Factory-calibrated with NIST traceable solutions, each PoolPro may be supplied with both certification of traceability & NIST traceable solutions for definitive calibration
pH/ORP Sensor protective cap
Fully automatic temperature compensation
Auto-shutoff maximizes the life of the single 9V battery to more than 100 hours/5000 tests
Non-volatile microprocessor provides data back-up, even when the battery is changed; this assures all calibrations and memory data are retained
Extended life pH/ORP sensor is user-replaceable in the field
|
|
Density/Specific Gravity/Concentration Meter - DMA 4500
The DMA 4500 was built to measure round the clock. Its rugged design and minimum required lab space make it a welcome addition to any lab.
The patented reference oscillator (AT 399051) allows measurement immediately after changing the measuring temperature, so you don't have to wait for long periods of time between measurements.
The DMA 4500 requires only 40 seconds to measure each sample, increasing the efficiency in your lab. Connect a sample changer to automate filling and cleaning procedures, freeing lab personnel for other tasks.
|
|
Concentration, Water Content and Dry Substance measured by microwaves
Your Advantages:
High selective sensitivity to water
High accuracy and long-term stability
even for difficult products
Simple installation, insertion directly
on the existing pipelines, vessels, chutes etc.
Simple start-up, system supported sample taking,
automatic calibration and graphic display
Accurate and reliable measurement
due to two highly stable PLL-synthesizers
and multi-frequency technology
Durable sensor measuring cells with wear resistant
smooth walled PTFE lining
Contactless measuring cell without installed
measuring antenna
High operational safety and standards of quality
|
|
|
The compact, rugged Thermo Scientific SGD-O is the most reliable non-contacting density gauge for monitoring fluid density, including PPG, PPA and SGU, in the oilfield during fracturing and cementing. Capable of enduring high shock and vibration yet lightweight, this advanced device features rapid response and high accuracy to improve consistency, safety and overall performance. Engineered to withstand the extreme moisture and high humidity of oilfield environments, it rapidly indicates variations in slurry density and proppant concentration during fracturing and cementing operations. The SGD-O is comprised of three components: the source and detector work together to measure the fluid density while the remotely located electronic transmitter provides a clear digital display of the measurement. This advanced gauge measures through any pipe thickness, with the detector providing response in three to five seconds and accuracy of ±0.1 pounds per gallon. The transmitter can be mounted up to 100 feet away from the gauge to ensure worker safety. It can be powered by a readily available 12 or 24 volt power supply and features quick disconnect connectors for cable and transmitters. The SGD-O is also easy-to-install and use and has minimal maintenance requirements.
|
|
Microprocessor-controlled instrument amplifier with integrated controller for water analysis of:
pH
Redox
Ion concentration
Electrolytic conductivity (conductive and inductive)
Active chlorine concentration
Total chlorine concentration
Chlorine dioxide concentration
Oxygen concentration
Ozone concentration
Hydrogen peroxide concentration
Features:
Backlit 2-line alphanumeric LC display with measuring units
Clear text human-machine interface with only 5 touch keys
Password protection against unauthorized operation
Temperature compensation manual or via Pt 100 / 1000 / NTC 22 kOhm (3-wire)
Galvanic separation of inputs and outputs
2 analog outputs, user configurable
Integrated controller with 2 switching points
2 limit switches with time-delay, allocated to alarm relay
Display of operating and status messages
|
|
|
Das batteriebetriebene tragbare Dichtemessgerät ist weltweit das meistverwendete dieser Art. Entwickelt für den Einsatz im anspruchsvollen industriellen Alltag, misst das DMA 35n Dichte, relative Dichte sowie diverse Konzentrationen (z.B. Alkohol oder API-Zahl). Alle Messergebnisse sind temperaturkompensiert. Über eine Pipettenpumpe wird die Messzelle befüllt. Sekunden später erscheinen die Ergebnisse.
|
|
Membrane covered galvanic
oxygen sensor
• Temperature compensation
• Up to 6 months usage of membrane
• High signal resolution
• Rapid response
• Waterproof sensor (IP 68 – 2 bar)
• Incl. calibration vessel OxiCal®-SL
• Membrane leakage monitoring
|
|
Concentration measurement (System Aquasant-MT)
The concentration measuring system measures the product concentration of organic product mixtures with one variant, taking also in account the product temperature. Surveillance of chemical reactions directly in the production line (Determination of the end point).
Measuring principle: High resolution impedance measurement
Fast product temperature measuremnt
Adaptive automatic temperature linearization
Concentration measurement
digital (Relay output) pre-alarm/alarm
analog (0/4 - 20 mA) programmable
RS-232-interface and visualization software for parameterization, online data input or data evaluation from the memory
Self controlled measuring circuit
Hazardous area version
II (2) G [EEx ia] IIC ; SEE 99 ATEX 2469; CE 0499 EMV STS 024 CE
Sample of concentration measurements of organic mixtures with one variant
Ethyl alcohol (Ethanol) in 1-propanol
Ethyl alcohol (Ethanol) in toluene
Water content in isopropanol
Acetic anhydrid in acetic acid
0-1 % water in formic acid
15 - 20 % N-Bulitium in toluene
0-10 % ethyl alcohol (Ethanol) in demin. water 1-7 µS
|
|
The total TDS is a mass estimate and is dependent on the mix of chemical species as well as the concentration while conductivity is only dependent on the concentration of chemical species. Some applications require the measurement of Total Dissolved Solids (TDS) in mg/L, parts per million (ppm) or parts per thousand (ppt). The TDS concentration can be obtained by multiplying the conductivity
value with a factor which is empirically determined. Eutech offers meters that allow the direct reading
of TDS values. These include the TDSTestr series, EcoScan TDS 6, CyberScan Standard Portables CON 11, CON 110 and Waterproof Portable CON 410. Bench meters for advanced level laboratory research are the CyberScan CON 510, CON 1500 and colour touchscreen research-grade CON 6000.
|
|
OX60
WPA's OX60 meter is based on proprietary Application Specific Integrated Circuit (ASIC) design and uses a new low cost 12mm diameter galvanic DO probe that is easy to use. This compact meter is ideal for indoor and outdoor applications.
OX100
The OX100 Dissolved oxygen meter is designed to overcome the traditional problems with field calibration and lack of reliability associated with many DO instruments.
|
|
|
DO stands for Dissolved Oxygen, which is the measure of amount of gaseous oxygen dissolved in a solution. In theory, the amount of DO in a solution is dependent on 3 factors, namely temperature, salinity and atmospheric pressure. The measurement of DO requires a special DO electrode that is made up of an anode, a cathode, electrolyte solution and a gas permeable membrane.
|
|
Dissolved Oxygen Probes
Select from a full range of Orion Dissolved Oxygen Probes for both field and laboratory applications.
|
|
|