This range of small probes with 3 mini-sensors measure pH, ORP, conductivity, temperature DO and level in wastewater, natural water and underground water. These SDI-12 ultra low comsuption probes can be connected to all SDI-12 systems
Using AQUA, AQUA 10 or AQUA 50 probes allows you to measure up to 6 parameters simultaneously: Temperature, Conductivity, pH, ORP, Dissolved Oxygen and Depth.
- Fast connection to ISCO devices, ADCON remote systems or any other instruments using the SDI12 protocol
- Ultra low consumption (40 µA)
- Connection of the sensors by simple "clip"
- Pocket size for maximum user convenience (length = 420 mm, diameter = 40 mm)
- Flexibility in use : its independent connection cable length allows adjusting cable length according to your needs
3 probes are available :
- AQUA : Wastewater
- AQUA 10 : Surface water (0-10 m),
- AQUA 50 : Underground water (0-50 m).
|
|
|
|
|
|
Near-Infrared, Non-Invasive Tissue Oximeter
OxiplexTS is a revolutionary new device allowing the measurement of oxygenated and de-oxygenated hemoglobin concentrations in tissue. The device works by emitting Near Infrared (NIR) light into tissue at known distances from a collector. Light of two different wavelengths is used and the light is modulated at an RF frequency of 110 MHz. The collected light is measured and processed, and the absorption and scattering coefficients of the medium are determined. Once the absorption and scattering are determined, the assumption that hemoglobin is the only significant absorber is applied and the oxygenated and de-oxygenated hemoglobin concentrations are calculated.
The unique feature of the ISS OxiplexTS is that it uses the theory of photon migration through highly scattering media. This patented technology allows for the first time the absolute measurement of absorption and scattering in a highly scattering medium such as human tissue.
Since OxiplexTS measures the absorption and scattering of tissues directly, it does not require any calibration, estimation, or assumption about scattering in order to make an accurate measurement of absorption and, hence, hemoglobin concentrations. This unique ability to separate scattering from absorption sets the ISS OxiplexTS above all other NIR tissue oximeter technologies.
|
|
The inoLab® BSB/BOD 740 laboratory oxygen meter has been specially developed for BODn measurements. BOD measurements are determined according to EN 1899-1 and are EPA approved.
You can store up to 7 of your own routines for frequently occurring dilution ratios. A maximum of 30 measuring samples each with 18 dilutions allow the management of up to 540 diluted samples.
The inoLab® BSB/BOD 740 can also be used as a conventional high-end oxygen meter. Additional memory and editing options are available when MultiLab® pilot is used. The entire measurement and sample management can thus be easily handled via PC.
In combination with StirrOx® G with its automatic start/stop function the inoLab® BSB/BOD 740 is the ideal measuring system for routine oxygen measurement in the BOD5 determination according to DIN EN 1899-1 and DIN EN 1899-2.
• Simple sample management
• Automatic BOD calculation
• EPA approved
|
|
|
|
|
|
Biochemical oxygen demand BOD determination is still one of the most important parameters in water resource management. It can be used to evaluate the impact of biodegradable substances in waters and waster water. With its OxiTop® systems, WTW offers a unique, modular and mercury-free instrument system. It is not only suitable for BOD determination, but also for measuring biodegradability and depletion.
In the course of growing environmental consciousness, microbiological degradability tests have become increasingly important. These can be, for example, soil surveys from waste sites or environmental impact surveys for new chemical substances. The necessary respiration measurements for anaerobic or aerobic degradation can be easily carried out using the OxiTop®-C systems with excellent analysis. WTW offers a wide range of application specific packages with appropriate sample vessels.
The advantages of OxiTop® and OxiTop® Control: simple operation, improved controllability and non-toxicity, and measuring ranges of up to 400 000 mg/l BOD (with OxiTop® Control OC 110). As the measured pressure is automatically converted the values can be directly read as mg/l BOD
|
|
- Multiparameter measurements
- Quick calibration in each mode
- 2 sensor inputs (pH and conductivity/dissolved oxygen)
- 199 results stored
-You can read your results at a glance on the large backlit LCD.
-Store your results automatically with the date and time.
-Follow a user-friendly icon-based menu.
-Use colour-coded bottles for error-free calibration.
-Give your electrodes a new lease of life with a single click thanks to the cartridge concept.
-Built-in RS232 connection to document and archive measurements results onto a PC
|
|
The system: for pH, cond. and O2 - reliable, flexible, simpler than ever
High Quality Digital - HQD-meter
means complete, coordinated, stable meters with practical accessories and intelligent electrodes. What makes HQD special is the newly developed INTELLICAL electrodes, which store all relevant characteristic parameters in digital form.
- Digital INTELLICAL electrodes and metes are interchargeable (Mix Match principle).
- Digital INTELLICAL electrodes are recognised automatically.
- The calibration data is stored in the INTELLICAL electrodes, and the control intervals can be programmed to enable application - specific status checks.
- All INTELLICAL electrodes with integrated temperature sensor.
|
|
|
|
|
|
The inoLab® benchtop meters of WTW, Weilheim, Germany, have been relaunched in April 2004. Now, an appropriate meter is available for almost every application :
1) Easy-to-operate, reliable, with big, bright display, battery or mains operated: inoLab® 720 series for pH/ORP, conductivity, dissolved oxygen (Multi 720).
2) Precise, communicative, with datalogger, memory, digital/analog RS 232 interface, printer (optional), GLP supporting: inoLab® 730 for pH/mV, dissolved oxygen, conductivity.
3) Enhanced methods for ISE measurement, menu-driven, backlit graphic display: inoLab® 735 pH/ION.
4) Communicative, high-performance, PC-controllable meters with enhanced possibilities like digital recorder or user administration: inoLab® 740 series, for all parameters, additionally BOD-measuring system.
5) Outstanding performance for special tasks in highly demanding applications: inoLab® pH/ION/Cond 750 with two high-impedance inputs, simultaneous measuring of three parameters (2 times pH or ISE or ORP and conductivity), PC-controllable, individual determination of conductivity temperature coefficients. Datalogger, memory, interface included. With user administration and password protection.
|
|
With new technology
The LDO oxygen probe and the pHD sc pH probe stand for superior technology. The LDO-Sensor determines the dissolved oxygen with an optical method, no more replacing of electrolyte or calibration. No electrode poisoning can occur because of the closed pHD sensor design. Less work and a longer service life in combination with gerater reliabilty translate into lower operating costs and appreciably more process dependabilty.
Wide range of applications
HACH LANGE probes can be installed in tanks, pipes or in bypasses - suitable mounting devices are available for every application.
By the application-specific design the probes can be exposed to aggressive fluids or high pressures.
The electrodes are kept separate from the sensitive digital electronics in an enclosure made of resistant plastic.
|
|
Membrane covered galvanic
oxygen sensor
• Temperature compensation
• Up to 6 months usage of membrane
• High signal resolution
• Rapid response
• Waterproof sensor (IP 68 – 2 bar)
• Incl. calibration vessel OxiCal®-SL
• Membrane leakage monitoring
|
|
Optical DO sensor without calibration nor maintenance.
Thanks to its Modbus RS485 output, this sensor is able to be connected directly to automates, datloggers or remote systems.
Fields of application : Fishfarming, wastewater, natural water, seawater
|
|
|
The series FMC -5000 /VQ are field mounting 2 or 3 chemical variables, with relationship capabillity betwen each. They have direct input for chemical sensors and they give the control signal in the field, at the same time, they transmit the data by RS-485 Modbus. In option, communication by Radio or Ethernet networks, cable or WiFi mode, is possible through “gateway” adapters RMT, EMT or WMT-1000.
|
|
HEITOLAB MPC 350 Multiparameter:
- multiparameter with microprocessor. It ensures the continuous measurement of four parameters : pH, redox, conductivity, temperature
- one analog output 4 - 20 mA for each parameter and one RS 232 digital output.
- conductivity : 6 measuring ranges with automatic or manual range change: 200 mS, 20 mS, 2 mS, 200 µS, 20 µS, 2 µ S
- temperature compensation : automatic if a Pt 100 probe is plugged in
|
|
Portable digital physicochemistry NEOTEK PONSEL
pH Redox, temperature, Disolved Oxygen, Turbidity, Conductivity
Always reliable measurements :
-Autocheck of the probe
-Probe status always displayed
Simplicity :
-Plug your probe and your system is immediatly ready to measure without verification
-Interchange your probe pH/ORP.T, Turbidity, Oxygen, conductivity...
High performances:
-Watertight terminal IP68 for field and laboratory use
-100 000 data memory
|
|
|
Measurements of dissolved oxygen (DO) in industrial processes serve to control the oxygen concentration, optimize the process and yield. Besides inline measurement the off- or near-line measurement system is often used for control at different sites with a compact portable transmitter/sensor system with data-logger, sampling device and interface to download stored measurement values.
|
|
|
|
|
|
Developed to meet all field and laboratory requierements, the Digital ODEON instruments combine the versatility of an easy-to-use, easy-to-read handheld unit.
Rugged, reliable and IP-67 waterproof, the ODEON measures dissolved oxygen with the new ODO optical probe, pH,ORP, conductivity, temperature, and turbidity.
Thanks to PONSEL plug and play digital probes, autodiagnostic and calibration data inside, you just have a total confidence in your readings. just measure !
You need a simple and robust mono-parameter instrument, purchase a ODEON Classic with one ultra low power probe (pH/ORP/T, DO, Conductivity or Turbidity)
You need a versatile instrument ? Purchase a ODEON OPEN ONE ! Thanks to the Open Technology, your one channel system will accepte all PONSEL probe.
Your application require simultaneously parameters from 2 probes, purchase the ODEON X
Available:
ODEON Classic line
ODEON Open line
ODEON X Line
ALWAYS READY TO MEASURE : Digital plug and play probes
ALWAYS CONFIDENCE : Autodiagnostic, status always displayed, GLP compliance
SIMPLICITY : Huge display and intuitive menus
HIGH PERFORMANCES : Mono/Multiparameters - 8 Mo Memory (100 000 datas),
FIELD INTRUMENTATION : IP67
|
|
WALL MOUNTING INSTRUMENTS
with one "ON or OFF" threshold and one output function 4 - 20 mA :
- pHM 200 : pH meter
- CM200 : conductivity-meter
- OXYM200 : oxymeter
- CLM200 : chlorometer
|
|
|
DO stands for Dissolved Oxygen, which is the measure of amount of gaseous oxygen dissolved in a solution. In theory, the amount of DO in a solution is dependent on 3 factors, namely temperature, salinity and atmospheric pressure. The measurement of DO requires a special DO electrode that is made up of an anode, a cathode, electrolyte solution and a gas permeable membrane.
|
|
Hach LDO™
Since 2002, Hach has established itself as the premier provider of Luminescent Dissolved Oxygen technology, and only Hydrolab Series 5 sondes feature Hach LDO technology – designed, manufactured, and supported by Hach in Loveland, Colorado.
Features:
- No membranes
- Calibrations that last
- Superior accuracy
- Compact housing allow complete integration into any sonde – DS5X, DS5, or even MS5
Benefits:
- Calibrations that last without drift means that deployments will last longer, reducing frequency of trips to the field for maintenance, saving you time and money
- No membranes so concerns about air bubbles, 24-hour membrane relaxation, and the art of maintenance are a thing of the past
- Does not consume oxygen so passive fouling will not affect DO readings
- Best accuracy because solid, defendable data is the ultimate goal
- Designed, manufactured, and supported by Hach Environmental, the experts in LDO technology, so all your questions can be addressed locally
|
|
These analyzers and sensor and mounting accessories are suitable for dissolved-oxygen measurement in the ppm range typically found in waste treatment applications. They ensure effective aeration and regulatory compliance.
Benefits:
- Rugged sensor delivers long reliable life
- Ball float, hand rail and swivel accessories provide convenient installation
- Membrane service kit provides cost-effective maintenance option
- Dual sensor input capability
|
|
Measurement and control instrument for dissolved oxygen
- Easy and safe operation by plain text menu guidance
- Safety by password function
description
The K 100 (W) O2 is a sophisticated single-channel instrument for measuring and control dissolved oxygen. Additionaly temperature measurement of the measuring media is possible. The instrument is available in a panel mounted housing (K100 O2) and in a wall mounted housing (K 100 W O2).
applications
|
|
Orion 3-Star Plus Benchtop Dissolved Oxygen Meter
- Improved stability algorithm to increase calibration and measurement accuracy
- Average slope and slope of segment printed with measurement
- Ability for ATC temperature calibration
- Increased data log points: 1000
- Ability to turn off data log
- Ability to print or view last 10 calibrations
- New Individual method passwords
- Now with ability to operate an auto-sampler!
- Ability to turn off BOD stirrer
- Solution and membrane temperature printed with measurement
- Solution and membrane temperature displayed
- Ability to calibrate both solution and membrane temperature
- DO slope now on printout
|
|
|
|
|
|
The HD 98569 is a portable multi-parameter data logger for electrochemical measures: pH, conductivity, dissolved oxygen and temperature. It is fi tted with a large back-lighted LCD display.
The instrument measures:
• pH, mV, redox potential (ORP) with pH, redox or combined pH/temperature electrodes complete with SICRAM module;
• conductivity, resistivity in liquids, total dissolved solids (TDS), and salinity
with combined 4-ring and 2-ring conductivity and temperature probes
with SICRAM module.
• Concentration of dissolved oxygen in liquids (in mg/l), saturation index
(in %) using SICRAM combined probes of polarographic type with two or
three electrodes and integrated temperature sensor.
The HD 98569 is a data logger, it memorizes up to 200 single screens (labels) and up to 9000 samples in continuous storage mode: pH or mV, conductivity or resistivity or TDS or salinity, concentration of dissolved oxygen and saturation index and temperature. The data can be transferred from the instrument connected to a PC via the multitandard RS232C serial port and USB 2.0-1.1.
|
|
Thermo Fisher Scientific offers a comprehensive range of Russell pH electrodes and electrochemical sensors. The full range of products includes meters, electrodes and ancillaries for the measurement of pH, ORP, conductivity, dissolved oxygen and specific ions. Water test strips and kits complement the range of products for the potable water and environmental testing markets. Thermo Fisher Scientific is committed to providing the best instrumentation for a wide array of laboratory analyses.
|
|
|
One cost-effective and convenient way to measure multiple parameters without the need to purchase many different meters is to make use of a multi-parameter meter. Most of these meters are able to measure 2 or more parameters. The models featured here measure pH, conductivity and dissolved oxygen.
|
|
|
|
|
|
The HI 9828 Multiparameter Portable Meter is a comprehensive analytical instrument, capable of measuring up to 13 critical water quality parameters (6 measured and 7 calculated), including pH, EC/TDS, ORP, DO, atmospheric pressure, and temperature. Some of the most advanced capabilities available are incorporated into this portable meter. Designed for intuitive operation, the menu-driven navigation is user-friendly and logical.
Engineered with smart features such as auto recognition of pH/ORP probe, auto-ranging adjustments for EC/TDS readings, and measurement check - to eliminate erroneous readings - and more, our design acually simplifies operations and handling. There is virtually no learning curve to getting into this meter and quickly mastering it's capabilities. For field applications, Hanna's Quick Calibration allows the user to standardize pH, conductivity and dissolved oxygen, all with one solution! While in calibration mode, the meter will also assess and verify probe functionality. For monitoring and recording data, HI 9828 can be equipped with Hanna's optional T.I.S. - Tag Identification System: iButton©s with unique ID numbers. Installed at any sampling site, these tags will record and match specific location information with logging data. Comprehensive GLP features, such as last calibration date and status information, calibration time-out, and date and time tags associated with sample measurements, ensure consistency and accountability. The LOGGER function memorizes data from each connected sensors and log-on-demand & automatic logging can record up to 60,000 data samples. All data is downloadable to a PC via USB connectivity.
|
|
Details
Products: Meters
Parameters: pH ORP
K100 W PR
Art.-No.: 105000K
User-friendly controller for pH/ORP, wall-mounting enclosure
Series:K100
Delivery time: 2 days
|
|
The dissolved oxygen analyzer, model 7118, is used for online measurement of dissolved oxygen concentration in the condensate, feed water, etc., of thermal or nuclear power plants. As membrane electrodes are used to measure dissolved oxygen, the analyzer can be used in a closed-loop system without contaminating the samples.
* Provided with an automatic calibration function
* Membrane polarographic electrodes are used.
* Quick response
* A wide selection of ranges is available.
|
|
OM-51 Portable Dissolved Oxygen Meter
Product Overview
This field-type dissolved oxygen meter measures dissolved oxygen concentration (DO), oxygen concentration (O2), saturation (SAT.RATIO) and temperature of water solutions. It uses a laboratory sensor to enable BOD measurement. Waterproof construction enables use at virtually any measurement site. This meter is being used in research institutions, and at a variety water quality related production sites in the mining, agriculture, forestry and fishery industries.
|
|
|
Transmitters are an integral part of on-line measurement systems used to monitor and control industrial processes. METTLER TOLEDO offers a comprehensive range of transmitters for pH, DO, conductivity, resistivity, TOC, dissolved ozone, turbidity,
|
|
see the results for the following category : Gas sensors |
|
|