pH-ORP
Patented non-glass Durafet probes and traditional glass pH technology help measure, analyze and transmit pH and ORP information in industrial processes. Honeywell provides a complete line of analyzers and transmitters, and several mounting types.
7758/7758D Pipeline Mounting
The 7758 pipeline electrode mounting uses a stainless steel or polypropylene bushing with 3/4" NPT for mounting in pipelines.
7773/7773D Flow & Immersion Mounting
7773 mounting capabilities encompass the industrial measurements of pH, ORP, specific ion and temperature in a flow or submersion configuration.
7774/7774D Insertion Removal Mounting
The 7774 insertion/removal assemblies, which accommodate Durafet II and Meredian series combination (single-probe) pH or ORP electrodes, are designed for use in processes under pressure because the electrode can be inserted or removed without interrupting the process.
7777/7777D Immersion/In-Line Glass Mounting
Honeywell's 7777 series of electrode mountings enables users to interface Durafet II pH electrodes with a process via a ¾" threaded connection and Meredian II by either submersing the electrode or mounting it into a ¾" threaded connection.
7777DVP Immersion/In-Line Mounting
Honeywell's 7777DVP Series of electrode mountings enables users to interface Durafet III pH electrodes to a process via a ¾" threaded connection by either submersing the electrode or mounting it into a ¾" threaded connection.
7794DVP Sanitary Durafet III Mounting
The Sanitary Durafet III pH electrode has an integral, tri-clamp flange for easy mounting in the process.
HB Series Ruggedized Electrodes
Honeywell's HB Series of electrode mountings are designed for high temperature, high pressure and harsh chemical applications.
Transmitter - APT2000PH
The APT2000PH transmitter is a two-wire 24-volt device that continuously measures pH or ORP in industrial processes.
Analyzer - APT4000PH
The APT4000 pH/ORP analyzer continuously measures pH or ORP in industrial processes.
DirectLine DL421 pH Transmitter
The DL421 transmitter can be connected directly to the electrode as one integral mounted unit. Alternatively, the transmitter can be wall, pipe or DIN rail mounted remotely from the associated pH electrode.
DirectLine DL422 ORP Transmitter
The Meredian II ORP electrode can be located directly on to the DL422 transmitter module as one integral mounted unit. Alternatively the DL422 transmitter can be wall, pipe or DIN rail mounted remotely from the ORP electrode.
DirectLine DL1000 Durafet Mountings
DL1000 pH electrode in combination with DL421 pH transmitter either directly or remotely mounted offer an ideal end user solution to online pH measurement. Installation, maintenance and performance cost savings are assured.
DirectLine DL2000 Meredian Glass Mountings
For pH measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL2000 Meredian glass pH electrode.
DirectLine DL3000 ORP Mountings
For ORP measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL3000 ORP electrode.
Durafet non-Glass pH Sensor
The Durafet pH electrode is an industrial, non-glass, unbreakable, Ion Sensitive Field Effect Transistor (ISFET)-based pH sensor that provides fast, accurate and dependable pH measurement in the most demanding applications.
HPW7000 HiPurity pH Measurement System
The HPW7000 HiPurity Water pH Measurement System is an electrode mounting assembly designed specifically for the difficult pH measurement in high-purity water applications.
TL1000 Durafet II Twist Lock Mounting
The TL1000 Series, Twist Lock Mounting, provides an easy way to install/remove Durafet III pH electrodes from pipelines and tees. A quick ¼ turn is all that is required for installation/removal.
Analyzer - UDA2182 Multiple Input
The UDA2182 Universal Dual Analyzer represents the latest in analyzer technology by providing the most versatile multiple-input analyzer package on the market for measurement of pH, ORP, conductivity and dissolved oxygen.
|
|
pH-ORP
Patented non-glass Durafet probes and traditional glass pH technology help measure, analyze and transmit pH and ORP information in industrial processes. Honeywell provides a complete line of analyzers and transmitters, and several mounting types.
7758/7758D Pipeline Mounting
The 7758 pipeline electrode mounting uses a stainless steel or polypropylene bushing with 3/4" NPT for mounting in pipelines.
7773/7773D Flow & Immersion Mounting
7773 mounting capabilities encompass the industrial measurements of pH, ORP, specific ion and temperature in a flow or submersion configuration.
7774/7774D Insertion Removal Mounting
The 7774 insertion/removal assemblies, which accommodate Durafet II and Meredian series combination (single-probe) pH or ORP electrodes, are designed for use in processes under pressure because the electrode can be inserted or removed without interrupting the process.
7777/7777D Immersion/In-Line Glass Mounting
Honeywell's 7777 series of electrode mountings enables users to interface Durafet II pH electrodes with a process via a ¾" threaded connection and Meredian II by either submersing the electrode or mounting it into a ¾" threaded connection.
7777DVP Immersion/In-Line Mounting
Honeywell's 7777DVP Series of electrode mountings enables users to interface Durafet III pH electrodes to a process via a ¾" threaded connection by either submersing the electrode or mounting it into a ¾" threaded connection.
7794DVP Sanitary Durafet III Mounting
The Sanitary Durafet III pH electrode has an integral, tri-clamp flange for easy mounting in the process.
HB Series Ruggedized Electrodes
Honeywell's HB Series of electrode mountings are designed for high temperature, high pressure and harsh chemical applications.
Transmitter - APT2000PH
The APT2000PH transmitter is a two-wire 24-volt device that continuously measures pH or ORP in industrial processes.
Analyzer - APT4000PH
The APT4000 pH/ORP analyzer continuously measures pH or ORP in industrial processes.
DirectLine DL421 pH Transmitter
The DL421 transmitter can be connected directly to the electrode as one integral mounted unit. Alternatively, the transmitter can be wall, pipe or DIN rail mounted remotely from the associated pH electrode.
DirectLine DL422 ORP Transmitter
The Meredian II ORP electrode can be located directly on to the DL422 transmitter module as one integral mounted unit. Alternatively the DL422 transmitter can be wall, pipe or DIN rail mounted remotely from the ORP electrode.
DirectLine DL1000 Durafet Mountings
DL1000 pH electrode in combination with DL421 pH transmitter either directly or remotely mounted offer an ideal end user solution to online pH measurement. Installation, maintenance and performance cost savings are assured.
DirectLine DL2000 Meredian Glass Mountings
For pH measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL2000 Meredian glass pH electrode.
DirectLine DL3000 ORP Mountings
For ORP measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL3000 ORP electrode.
Durafet non-Glass pH Sensor
The Durafet pH electrode is an industrial, non-glass, unbreakable, Ion Sensitive Field Effect Transistor (ISFET)-based pH sensor that provides fast, accurate and dependable pH measurement in the most demanding applications.
HPW7000 HiPurity pH Measurement System
The HPW7000 HiPurity Water pH Measurement System is an electrode mounting assembly designed specifically for the difficult pH measurement in high-purity water applications.
TL1000 Durafet II Twist Lock Mounting
The TL1000 Series, Twist Lock Mounting, provides an easy way to install/remove Durafet III pH electrodes from pipelines and tees. A quick ¼ turn is all that is required for installation/removal.
Analyzer - UDA2182 Multiple Input
The UDA2182 Universal Dual Analyzer represents the latest in analyzer technology by providing the most versatile multiple-input analyzer package on the market for measurement of pH, ORP, conductivity and dissolved oxygen.
|
|
The inoLab® BSB/BOD 740 laboratory oxygen meter has been specially developed for BODn measurements. BOD measurements are determined according to EN 1899-1 and are EPA approved.
You can store up to 7 of your own routines for frequently occurring dilution ratios. A maximum of 30 measuring samples each with 18 dilutions allow the management of up to 540 diluted samples.
The inoLab® BSB/BOD 740 can also be used as a conventional high-end oxygen meter. Additional memory and editing options are available when MultiLab® pilot is used. The entire measurement and sample management can thus be easily handled via PC.
In combination with StirrOx® G with its automatic start/stop function the inoLab® BSB/BOD 740 is the ideal measuring system for routine oxygen measurement in the BOD5 determination according to DIN EN 1899-1 and DIN EN 1899-2.
• Simple sample management
• Automatic BOD calculation
• EPA approved
|
|
Biochemical oxygen demand BOD determination is still one of the most important parameters in water resource management. It can be used to evaluate the impact of biodegradable substances in waters and waster water. With its OxiTop® systems, WTW offers a unique, modular and mercury-free instrument system. It is not only suitable for BOD determination, but also for measuring biodegradability and depletion.
In the course of growing environmental consciousness, microbiological degradability tests have become increasingly important. These can be, for example, soil surveys from waste sites or environmental impact surveys for new chemical substances. The necessary respiration measurements for anaerobic or aerobic degradation can be easily carried out using the OxiTop®-C systems with excellent analysis. WTW offers a wide range of application specific packages with appropriate sample vessels.
The advantages of OxiTop® and OxiTop® Control: simple operation, improved controllability and non-toxicity, and measuring ranges of up to 400 000 mg/l BOD (with OxiTop® Control OC 110). As the measured pressure is automatically converted the values can be directly read as mg/l BOD |
|
3S Compactoc analyzer has been designed for the automatic measurement of total organic carbon in water, on different types of matrix.
The analyzer measures Total Organic Carbon in liquid samples using the
EPA approved method based on UV persulfate oxidation and detection of
generated carbon dioxide using a Non Dispersive Infrared Analyzer. This
method meets also the requirements of European ISO/CEN guidelines.
The analyzer provides this measurements on liquid samples ranging from
0-20 mg/l to 0-1000 mg/l. The analyzer is conformed to EPA, DIN, CE, ASTM, NAMUR regulations.
Applications:
- industrial wastewater
- industrial effluents
- laboratory
- effluent and influent monitoring
- boiler feed water
- condensate and cooling water
- drinking water
- surface water
- process water |
|
Microprocessor-controlled instrument amplifier with integrated controller for water analysis of:
pH
Redox
Ion concentration
Electrolytic conductivity (conductive and inductive)
Active chlorine concentration
Total chlorine concentration
Chlorine dioxide concentration
Oxygen concentration
Ozone concentration
Hydrogen peroxide concentration
Features:
Backlit 2-line alphanumeric LC display with measuring units
Clear text human-machine interface with only 5 touch keys
Password protection against unauthorized operation
Temperature compensation manual or via Pt 100 / 1000 / NTC 22 kOhm (3-wire)
Galvanic separation of inputs and outputs
2 analog outputs, user configurable
Integrated controller with 2 switching points
2 limit switches with time-delay, allocated to alarm relay
Display of operating and status messages
|
|
The system: for pH, cond. and O2 - reliable, flexible, simpler than ever
High Quality Digital - HQD-meter
means complete, coordinated, stable meters with practical accessories and intelligent electrodes. What makes HQD special is the newly developed INTELLICAL electrodes, which store all relevant characteristic parameters in digital form.
- Digital INTELLICAL electrodes and metes are interchargeable (Mix Match principle).
- Digital INTELLICAL electrodes are recognised automatically.
- The calibration data is stored in the INTELLICAL electrodes, and the control intervals can be programmed to enable application - specific status checks.
- All INTELLICAL electrodes with integrated temperature sensor.
|
|
- Multiparameter measurements
- Quick calibration in each mode
- 2 sensor inputs (pH and conductivity/dissolved oxygen)
- 199 results stored
-You can read your results at a glance on the large backlit LCD.
-Store your results automatically with the date and time.
-Follow a user-friendly icon-based menu.
-Use colour-coded bottles for error-free calibration.
-Give your electrodes a new lease of life with a single click thanks to the cartridge concept.
-Built-in RS232 connection to document and archive measurements results onto a PC
|
|
The inoLab® benchtop meters of WTW, Weilheim, Germany, have been relaunched in April 2004. Now, an appropriate meter is available for almost every application :
1) Easy-to-operate, reliable, with big, bright display, battery or mains operated: inoLab® 720 series for pH/ORP, conductivity, dissolved oxygen (Multi 720).
2) Precise, communicative, with datalogger, memory, digital/analog RS 232 interface, printer (optional), GLP supporting: inoLab® 730 for pH/mV, dissolved oxygen, conductivity.
3) Enhanced methods for ISE measurement, menu-driven, backlit graphic display: inoLab® 735 pH/ION.
4) Communicative, high-performance, PC-controllable meters with enhanced possibilities like digital recorder or user administration: inoLab® 740 series, for all parameters, additionally BOD-measuring system.
5) Outstanding performance for special tasks in highly demanding applications: inoLab® pH/ION/Cond 750 with two high-impedance inputs, simultaneous measuring of three parameters (2 times pH or ISE or ORP and conductivity), PC-controllable, individual determination of conductivity temperature coefficients. Datalogger, memory, interface included. With user administration and password protection.
|
|
With new technology
The LDO oxygen probe and the pHD sc pH probe stand for superior technology. The LDO-Sensor determines the dissolved oxygen with an optical method, no more replacing of electrolyte or calibration. No electrode poisoning can occur because of the closed pHD sensor design. Less work and a longer service life in combination with gerater reliabilty translate into lower operating costs and appreciably more process dependabilty.
Wide range of applications
HACH LANGE probes can be installed in tanks, pipes or in bypasses - suitable mounting devices are available for every application.
By the application-specific design the probes can be exposed to aggressive fluids or high pressures.
The electrodes are kept separate from the sensitive digital electronics in an enclosure made of resistant plastic.
|
|
| AQUALYTIC BOD OxiDirect system, complete unit with 6 sensor heads and control unit with batteries. Inductive stirring unit with power supply 6 sample bottles 6 rubber gaskets 6 magnetic stirring rods. |
|
COD, chemical oxygen demand, by heat digestion plus
tritration or colorimetric measurement. Detection limit
10 ppm O2.
Total-N or Total-P by heat or UV-digestion plus colori-
metric measurements. Detection limits 0,3 ppb N and
1 ppb P.
Total-CN or Total-Phenol by distallation plus colorimetric
measurements. Detection limits 1 ppb CN and 6 ppb Phenol. |
|
OX60
WPA's OX60 meter is based on proprietary Application Specific Integrated Circuit (ASIC) design and uses a new low cost 12mm diameter galvanic DO probe that is easy to use. This compact meter is ideal for indoor and outdoor applications.
OX100
The OX100 Dissolved oxygen meter is designed to overcome the traditional problems with field calibration and lack of reliability associated with many DO instruments.
|
|
| DO stands for Dissolved Oxygen, which is the measure of amount of gaseous oxygen dissolved in a solution. In theory, the amount of DO in a solution is dependent on 3 factors, namely temperature, salinity and atmospheric pressure. The measurement of DO requires a special DO electrode that is made up of an anode, a cathode, electrolyte solution and a gas permeable membrane. |
|
Dissolved Oxygen Probes
Select from a full range of Orion Dissolved Oxygen Probes for both field and laboratory applications. |
|
The YSI 5300A Biological Oxygen Monitor is ideal for a variety of teaching and research applications in the laboratory. The 5300A measures oxygen consumption and evolution in a variety of samples including respiration, oxidative activity, and cellular metabolism studies.
The 5300A utilizes Clark-type polarographic oxygen probes immersed in magnetically-stirred sample chambers, and produces oxygen uptake or evolution curves in two to 15 minutes. This two-channel instrument offers simultaneous display, recorder outputs, and RS-232 serial output for monitoring the results of each evaluation of samples. |
|
Thermo Fisher Scientific offers a comprehensive range of Russell pH electrodes and electrochemical sensors. The full range of products includes meters, electrodes and ancillaries for the measurement of pH, ORP, conductivity, dissolved oxygen and specific ions. Water test strips and kits complement the range of products for the potable water and environmental testing markets. Thermo Fisher Scientific is committed to providing the best instrumentation for a wide array of laboratory analyses.
|
|
Whether for testing in the laboratory, pilot plant or production, the YSI 7100 MBS is a powerful, upgradable Multiparameter Bioanalytical System with core features that make this platform a productivity tool for today and into the future.
The unit builds upon the accuracy and precision of YSI's proven sensor technology with improvements in efficiency, flexibility, and intelligence.
Capable of measuring six distinct parameters simultaneously, the system can be customized with up to three sensor modules-each containing up to two chemistry sensors. Existing chemistries include the following:
Glucose-Sucrose-Lactate-Glutamate-Glutamine-Ethanol-Methanol-Ammonium-Potassium-Galactose
|
|
| One cost-effective and convenient way to measure multiple parameters without the need to purchase many different meters is to make use of a multi-parameter meter. Most of these meters are able to measure 2 or more parameters. The models featured here measure pH, conductivity and dissolved oxygen. |
|
Features:
- Microprocessor based for fast and accurate measurements.
- Large LCD display DO and Temperature Simultaneously.
- Simple to calibration by one keyboard and automatic temperature compensation.
- Memory stores and recalls up to 16 points and Data-hold-funtion.
- Low battery and consumption indicator. Auto shut off after 10 minutes of non use. |
|
HEITOLAB MPC 350 Multiparameter:
- multiparameter with microprocessor. It ensures the continuous measurement of four parameters : pH, redox, conductivity, temperature
- one analog output 4 - 20 mA for each parameter and one RS 232 digital output.
- conductivity : 6 measuring ranges with automatic or manual range change: 200 mS, 20 mS, 2 mS, 200 µS, 20 µS, 2 µ S
- temperature compensation : automatic if a Pt 100 probe is plugged in |
|
WALL MOUNTING INSTRUMENTS
with one "ON or OFF" threshold and one output function 4 - 20 mA :
- pHM 200 : pH meter
- CM200 : conductivity-meter
- OXYM200 : oxymeter
- CLM200 : chlorometer |
|
| ... products without technical information |
| |
|
|