The inoLab® BSB/BOD 740 laboratory oxygen meter has been specially developed for BODn measurements. BOD measurements are determined according to EN 1899-1 and are EPA approved.
You can store up to 7 of your own routines for frequently occurring dilution ratios. A maximum of 30 measuring samples each with 18 dilutions allow the management of up to 540 diluted samples.
The inoLab® BSB/BOD 740 can also be used as a conventional high-end oxygen meter. Additional memory and editing options are available when MultiLab® pilot is used. The entire measurement and sample management can thus be easily handled via PC.
In combination with StirrOx® G with its automatic start/stop function the inoLab® BSB/BOD 740 is the ideal measuring system for routine oxygen measurement in the BOD5 determination according to DIN EN 1899-1 and DIN EN 1899-2.
• Simple sample management
• Automatic BOD calculation
• EPA approved
|
|
3S Compactoc analyzer has been designed for the automatic measurement of total organic carbon in water, on different types of matrix.
The analyzer measures Total Organic Carbon in liquid samples using the
EPA approved method based on UV persulfate oxidation and detection of
generated carbon dioxide using a Non Dispersive Infrared Analyzer. This
method meets also the requirements of European ISO/CEN guidelines.
The analyzer provides this measurements on liquid samples ranging from
0-20 mg/l to 0-1000 mg/l. The analyzer is conformed to EPA, DIN, CE, ASTM, NAMUR regulations.
Applications:
- industrial wastewater
- industrial effluents
- laboratory
- effluent and influent monitoring
- boiler feed water
- condensate and cooling water
- drinking water
- surface water
- process water |
|
With new technology
The LDO oxygen probe and the pHD sc pH probe stand for superior technology. The LDO-Sensor determines the dissolved oxygen with an optical method, no more replacing of electrolyte or calibration. No electrode poisoning can occur because of the closed pHD sensor design. Less work and a longer service life in combination with gerater reliabilty translate into lower operating costs and appreciably more process dependabilty.
Wide range of applications
HACH LANGE probes can be installed in tanks, pipes or in bypasses - suitable mounting devices are available for every application.
By the application-specific design the probes can be exposed to aggressive fluids or high pressures.
The electrodes are kept separate from the sensitive digital electronics in an enclosure made of resistant plastic.
|
|
| AQUALYTIC BOD OxiDirect system, complete unit with 6 sensor heads and control unit with batteries. Inductive stirring unit with power supply 6 sample bottles 6 rubber gaskets 6 magnetic stirring rods. |
|
COD, chemical oxygen demand, by heat digestion plus
tritration or colorimetric measurement. Detection limit
10 ppm O2.
Total-N or Total-P by heat or UV-digestion plus colori-
metric measurements. Detection limits 0,3 ppb N and
1 ppb P.
Total-CN or Total-Phenol by distallation plus colorimetric
measurements. Detection limits 1 ppb CN and 6 ppb Phenol. |
|
| One cost-effective and convenient way to measure multiple parameters without the need to purchase many different meters is to make use of a multi-parameter meter. Most of these meters are able to measure 2 or more parameters. The models featured here measure pH, conductivity and dissolved oxygen. |
|
pH-ORP
Patented non-glass Durafet probes and traditional glass pH technology help measure, analyze and transmit pH and ORP information in industrial processes. Honeywell provides a complete line of analyzers and transmitters, and several mounting types.
7758/7758D Pipeline Mounting
The 7758 pipeline electrode mounting uses a stainless steel or polypropylene bushing with 3/4" NPT for mounting in pipelines.
7773/7773D Flow & Immersion Mounting
7773 mounting capabilities encompass the industrial measurements of pH, ORP, specific ion and temperature in a flow or submersion configuration.
7774/7774D Insertion Removal Mounting
The 7774 insertion/removal assemblies, which accommodate Durafet II and Meredian series combination (single-probe) pH or ORP electrodes, are designed for use in processes under pressure because the electrode can be inserted or removed without interrupting the process.
7777/7777D Immersion/In-Line Glass Mounting
Honeywell's 7777 series of electrode mountings enables users to interface Durafet II pH electrodes with a process via a ¾" threaded connection and Meredian II by either submersing the electrode or mounting it into a ¾" threaded connection.
7777DVP Immersion/In-Line Mounting
Honeywell's 7777DVP Series of electrode mountings enables users to interface Durafet III pH electrodes to a process via a ¾" threaded connection by either submersing the electrode or mounting it into a ¾" threaded connection.
7794DVP Sanitary Durafet III Mounting
The Sanitary Durafet III pH electrode has an integral, tri-clamp flange for easy mounting in the process.
HB Series Ruggedized Electrodes
Honeywell's HB Series of electrode mountings are designed for high temperature, high pressure and harsh chemical applications.
Transmitter - APT2000PH
The APT2000PH transmitter is a two-wire 24-volt device that continuously measures pH or ORP in industrial processes.
Analyzer - APT4000PH
The APT4000 pH/ORP analyzer continuously measures pH or ORP in industrial processes.
DirectLine DL421 pH Transmitter
The DL421 transmitter can be connected directly to the electrode as one integral mounted unit. Alternatively, the transmitter can be wall, pipe or DIN rail mounted remotely from the associated pH electrode.
DirectLine DL422 ORP Transmitter
The Meredian II ORP electrode can be located directly on to the DL422 transmitter module as one integral mounted unit. Alternatively the DL422 transmitter can be wall, pipe or DIN rail mounted remotely from the ORP electrode.
DirectLine DL1000 Durafet Mountings
DL1000 pH electrode in combination with DL421 pH transmitter either directly or remotely mounted offer an ideal end user solution to online pH measurement. Installation, maintenance and performance cost savings are assured.
DirectLine DL2000 Meredian Glass Mountings
For pH measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL2000 Meredian glass pH electrode.
DirectLine DL3000 ORP Mountings
For ORP measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL3000 ORP electrode.
Durafet non-Glass pH Sensor
The Durafet pH electrode is an industrial, non-glass, unbreakable, Ion Sensitive Field Effect Transistor (ISFET)-based pH sensor that provides fast, accurate and dependable pH measurement in the most demanding applications.
HPW7000 HiPurity pH Measurement System
The HPW7000 HiPurity Water pH Measurement System is an electrode mounting assembly designed specifically for the difficult pH measurement in high-purity water applications.
TL1000 Durafet II Twist Lock Mounting
The TL1000 Series, Twist Lock Mounting, provides an easy way to install/remove Durafet III pH electrodes from pipelines and tees. A quick ¼ turn is all that is required for installation/removal.
Analyzer - UDA2182 Multiple Input
The UDA2182 Universal Dual Analyzer represents the latest in analyzer technology by providing the most versatile multiple-input analyzer package on the market for measurement of pH, ORP, conductivity and dissolved oxygen.
|
|
pH-ORP
Patented non-glass Durafet probes and traditional glass pH technology help measure, analyze and transmit pH and ORP information in industrial processes. Honeywell provides a complete line of analyzers and transmitters, and several mounting types.
7758/7758D Pipeline Mounting
The 7758 pipeline electrode mounting uses a stainless steel or polypropylene bushing with 3/4" NPT for mounting in pipelines.
7773/7773D Flow & Immersion Mounting
7773 mounting capabilities encompass the industrial measurements of pH, ORP, specific ion and temperature in a flow or submersion configuration.
7774/7774D Insertion Removal Mounting
The 7774 insertion/removal assemblies, which accommodate Durafet II and Meredian series combination (single-probe) pH or ORP electrodes, are designed for use in processes under pressure because the electrode can be inserted or removed without interrupting the process.
7777/7777D Immersion/In-Line Glass Mounting
Honeywell's 7777 series of electrode mountings enables users to interface Durafet II pH electrodes with a process via a ¾" threaded connection and Meredian II by either submersing the electrode or mounting it into a ¾" threaded connection.
7777DVP Immersion/In-Line Mounting
Honeywell's 7777DVP Series of electrode mountings enables users to interface Durafet III pH electrodes to a process via a ¾" threaded connection by either submersing the electrode or mounting it into a ¾" threaded connection.
7794DVP Sanitary Durafet III Mounting
The Sanitary Durafet III pH electrode has an integral, tri-clamp flange for easy mounting in the process.
HB Series Ruggedized Electrodes
Honeywell's HB Series of electrode mountings are designed for high temperature, high pressure and harsh chemical applications.
Transmitter - APT2000PH
The APT2000PH transmitter is a two-wire 24-volt device that continuously measures pH or ORP in industrial processes.
Analyzer - APT4000PH
The APT4000 pH/ORP analyzer continuously measures pH or ORP in industrial processes.
DirectLine DL421 pH Transmitter
The DL421 transmitter can be connected directly to the electrode as one integral mounted unit. Alternatively, the transmitter can be wall, pipe or DIN rail mounted remotely from the associated pH electrode.
DirectLine DL422 ORP Transmitter
The Meredian II ORP electrode can be located directly on to the DL422 transmitter module as one integral mounted unit. Alternatively the DL422 transmitter can be wall, pipe or DIN rail mounted remotely from the ORP electrode.
DirectLine DL1000 Durafet Mountings
DL1000 pH electrode in combination with DL421 pH transmitter either directly or remotely mounted offer an ideal end user solution to online pH measurement. Installation, maintenance and performance cost savings are assured.
DirectLine DL2000 Meredian Glass Mountings
For pH measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL2000 Meredian glass pH electrode.
DirectLine DL3000 ORP Mountings
For ORP measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL3000 ORP electrode.
Durafet non-Glass pH Sensor
The Durafet pH electrode is an industrial, non-glass, unbreakable, Ion Sensitive Field Effect Transistor (ISFET)-based pH sensor that provides fast, accurate and dependable pH measurement in the most demanding applications.
HPW7000 HiPurity pH Measurement System
The HPW7000 HiPurity Water pH Measurement System is an electrode mounting assembly designed specifically for the difficult pH measurement in high-purity water applications.
TL1000 Durafet II Twist Lock Mounting
The TL1000 Series, Twist Lock Mounting, provides an easy way to install/remove Durafet III pH electrodes from pipelines and tees. A quick ¼ turn is all that is required for installation/removal.
Analyzer - UDA2182 Multiple Input
The UDA2182 Universal Dual Analyzer represents the latest in analyzer technology by providing the most versatile multiple-input analyzer package on the market for measurement of pH, ORP, conductivity and dissolved oxygen.
|
|
Dissolved Oxygen Probes
Select from a full range of Orion Dissolved Oxygen Probes for both field and laboratory applications. |
|
Thermo Fisher Scientific offers a comprehensive range of Russell pH electrodes and electrochemical sensors. The full range of products includes meters, electrodes and ancillaries for the measurement of pH, ORP, conductivity, dissolved oxygen and specific ions. Water test strips and kits complement the range of products for the potable water and environmental testing markets. Thermo Fisher Scientific is committed to providing the best instrumentation for a wide array of laboratory analyses.
|
|
| ... products without technical information |
| |
With new technology
The LDO oxygen probe and the pHD sc pH probe stand for superior technology. The LDO-Sensor determines the dissolved oxygen with an optical method, no more replacing of electrolyte or calibration. No electrode poisoning can occur because of the closed pHD sensor design. Less work and a longer service life in combination with gerater reliabilty translate into lower operating costs and appreciably more process dependabilty.
Wide range of applications
HACH LANGE probes can be installed in tanks, pipes or in bypasses - suitable mounting devices are available for every application.
By the application-specific design the probes can be exposed to aggressive fluids or high pressures.
The electrodes are kept separate from the sensitive digital electronics in an enclosure made of resistant plastic.
|
|
| One cost-effective and convenient way to measure multiple parameters without the need to purchase many different meters is to make use of a multi-parameter meter. Most of these meters are able to measure 2 or more parameters. The models featured here measure pH, conductivity and dissolved oxygen. |
|
pH-ORP
Patented non-glass Durafet probes and traditional glass pH technology help measure, analyze and transmit pH and ORP information in industrial processes. Honeywell provides a complete line of analyzers and transmitters, and several mounting types.
7758/7758D Pipeline Mounting
The 7758 pipeline electrode mounting uses a stainless steel or polypropylene bushing with 3/4" NPT for mounting in pipelines.
7773/7773D Flow & Immersion Mounting
7773 mounting capabilities encompass the industrial measurements of pH, ORP, specific ion and temperature in a flow or submersion configuration.
7774/7774D Insertion Removal Mounting
The 7774 insertion/removal assemblies, which accommodate Durafet II and Meredian series combination (single-probe) pH or ORP electrodes, are designed for use in processes under pressure because the electrode can be inserted or removed without interrupting the process.
7777/7777D Immersion/In-Line Glass Mounting
Honeywell's 7777 series of electrode mountings enables users to interface Durafet II pH electrodes with a process via a ¾" threaded connection and Meredian II by either submersing the electrode or mounting it into a ¾" threaded connection.
7777DVP Immersion/In-Line Mounting
Honeywell's 7777DVP Series of electrode mountings enables users to interface Durafet III pH electrodes to a process via a ¾" threaded connection by either submersing the electrode or mounting it into a ¾" threaded connection.
7794DVP Sanitary Durafet III Mounting
The Sanitary Durafet III pH electrode has an integral, tri-clamp flange for easy mounting in the process.
HB Series Ruggedized Electrodes
Honeywell's HB Series of electrode mountings are designed for high temperature, high pressure and harsh chemical applications.
Transmitter - APT2000PH
The APT2000PH transmitter is a two-wire 24-volt device that continuously measures pH or ORP in industrial processes.
Analyzer - APT4000PH
The APT4000 pH/ORP analyzer continuously measures pH or ORP in industrial processes.
DirectLine DL421 pH Transmitter
The DL421 transmitter can be connected directly to the electrode as one integral mounted unit. Alternatively, the transmitter can be wall, pipe or DIN rail mounted remotely from the associated pH electrode.
DirectLine DL422 ORP Transmitter
The Meredian II ORP electrode can be located directly on to the DL422 transmitter module as one integral mounted unit. Alternatively the DL422 transmitter can be wall, pipe or DIN rail mounted remotely from the ORP electrode.
DirectLine DL1000 Durafet Mountings
DL1000 pH electrode in combination with DL421 pH transmitter either directly or remotely mounted offer an ideal end user solution to online pH measurement. Installation, maintenance and performance cost savings are assured.
DirectLine DL2000 Meredian Glass Mountings
For pH measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL2000 Meredian glass pH electrode.
DirectLine DL3000 ORP Mountings
For ORP measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL3000 ORP electrode.
Durafet non-Glass pH Sensor
The Durafet pH electrode is an industrial, non-glass, unbreakable, Ion Sensitive Field Effect Transistor (ISFET)-based pH sensor that provides fast, accurate and dependable pH measurement in the most demanding applications.
HPW7000 HiPurity pH Measurement System
The HPW7000 HiPurity Water pH Measurement System is an electrode mounting assembly designed specifically for the difficult pH measurement in high-purity water applications.
TL1000 Durafet II Twist Lock Mounting
The TL1000 Series, Twist Lock Mounting, provides an easy way to install/remove Durafet III pH electrodes from pipelines and tees. A quick ¼ turn is all that is required for installation/removal.
Analyzer - UDA2182 Multiple Input
The UDA2182 Universal Dual Analyzer represents the latest in analyzer technology by providing the most versatile multiple-input analyzer package on the market for measurement of pH, ORP, conductivity and dissolved oxygen.
|
|
pH-ORP
Patented non-glass Durafet probes and traditional glass pH technology help measure, analyze and transmit pH and ORP information in industrial processes. Honeywell provides a complete line of analyzers and transmitters, and several mounting types.
7758/7758D Pipeline Mounting
The 7758 pipeline electrode mounting uses a stainless steel or polypropylene bushing with 3/4" NPT for mounting in pipelines.
7773/7773D Flow & Immersion Mounting
7773 mounting capabilities encompass the industrial measurements of pH, ORP, specific ion and temperature in a flow or submersion configuration.
7774/7774D Insertion Removal Mounting
The 7774 insertion/removal assemblies, which accommodate Durafet II and Meredian series combination (single-probe) pH or ORP electrodes, are designed for use in processes under pressure because the electrode can be inserted or removed without interrupting the process.
7777/7777D Immersion/In-Line Glass Mounting
Honeywell's 7777 series of electrode mountings enables users to interface Durafet II pH electrodes with a process via a ¾" threaded connection and Meredian II by either submersing the electrode or mounting it into a ¾" threaded connection.
7777DVP Immersion/In-Line Mounting
Honeywell's 7777DVP Series of electrode mountings enables users to interface Durafet III pH electrodes to a process via a ¾" threaded connection by either submersing the electrode or mounting it into a ¾" threaded connection.
7794DVP Sanitary Durafet III Mounting
The Sanitary Durafet III pH electrode has an integral, tri-clamp flange for easy mounting in the process.
HB Series Ruggedized Electrodes
Honeywell's HB Series of electrode mountings are designed for high temperature, high pressure and harsh chemical applications.
Transmitter - APT2000PH
The APT2000PH transmitter is a two-wire 24-volt device that continuously measures pH or ORP in industrial processes.
Analyzer - APT4000PH
The APT4000 pH/ORP analyzer continuously measures pH or ORP in industrial processes.
DirectLine DL421 pH Transmitter
The DL421 transmitter can be connected directly to the electrode as one integral mounted unit. Alternatively, the transmitter can be wall, pipe or DIN rail mounted remotely from the associated pH electrode.
DirectLine DL422 ORP Transmitter
The Meredian II ORP electrode can be located directly on to the DL422 transmitter module as one integral mounted unit. Alternatively the DL422 transmitter can be wall, pipe or DIN rail mounted remotely from the ORP electrode.
DirectLine DL1000 Durafet Mountings
DL1000 pH electrode in combination with DL421 pH transmitter either directly or remotely mounted offer an ideal end user solution to online pH measurement. Installation, maintenance and performance cost savings are assured.
DirectLine DL2000 Meredian Glass Mountings
For pH measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL2000 Meredian glass pH electrode.
DirectLine DL3000 ORP Mountings
For ORP measurement the DirectLine transmitter modules can be mounted integrally or remotely with the DL3000 ORP electrode.
Durafet non-Glass pH Sensor
The Durafet pH electrode is an industrial, non-glass, unbreakable, Ion Sensitive Field Effect Transistor (ISFET)-based pH sensor that provides fast, accurate and dependable pH measurement in the most demanding applications.
HPW7000 HiPurity pH Measurement System
The HPW7000 HiPurity Water pH Measurement System is an electrode mounting assembly designed specifically for the difficult pH measurement in high-purity water applications.
TL1000 Durafet II Twist Lock Mounting
The TL1000 Series, Twist Lock Mounting, provides an easy way to install/remove Durafet III pH electrodes from pipelines and tees. A quick ¼ turn is all that is required for installation/removal.
Analyzer - UDA2182 Multiple Input
The UDA2182 Universal Dual Analyzer represents the latest in analyzer technology by providing the most versatile multiple-input analyzer package on the market for measurement of pH, ORP, conductivity and dissolved oxygen.
|
|
Thermo Fisher Scientific offers a comprehensive range of Russell pH electrodes and electrochemical sensors. The full range of products includes meters, electrodes and ancillaries for the measurement of pH, ORP, conductivity, dissolved oxygen and specific ions. Water test strips and kits complement the range of products for the potable water and environmental testing markets. Thermo Fisher Scientific is committed to providing the best instrumentation for a wide array of laboratory analyses.
|
|
| ... products without technical information |
| |
|
|