Semi-Automatic Gum Content Determination by Jet Evaporation up to 280 °C
Gum content is the residue of substances mainly aircraft fuels and motor gasoline) under investigation which can not be evaporated under test conditions. The gum content is measured in units of mg/100 ml.
Suitable for: Aviation Fuel, Fuel, Gas Oil, Gasoline, Jet Fuel, Motor Gasoline, Turbine Fuel
|
|
|
|
|
|
MINIFLASH - The new Age of Flashpoint Testing
MINIFLASH is the only series of instruments for the automatic determination of the flashpoint of liquids and solid samples according to the advanced ASTM D7094 standard. This procedure describes the “Standard Test Method for Flash-Point by Modified Continuously Closed Cup (MCCCFP)”, which offers the highest repeatability and reproducibility and an excellent correlation to the D93 Pensky-Martens method: "there is no statistically significant bias observed between ASTM D7094 and ASTM D93 Procedure A” as concluded during the last Round Robin.
Test results are equivalent to other well known standards such as Abel and TAG, and thanks to its unique design MINIFLASH can be used for more difficult applications such as flash-point testing of contaminated samples like diesel fuel in lube oil or gasoline in diesel fuel and for biodiesel testing.
Its continuously closed cup design and small sample volume of only 2 mL offers maximum safety, avoids offensive fumes in the testing area and reduces sample waste.
Due to the true portability and rugged housing, the MINIFLASH is also the perfect solution for mobile labs and military applications.
Features
* Complies exclusively to ASTM D 7094 and ASTM D6450 (Flash-Point by Continuously Closed Cup)
* Maximum Safety: only 2ml sample, no open flame, continuously closed cup, no offensive vapors
* Excellent Correlation to ASTM D93, D56, ISO2719 (EN/DIN 22719), ISO13736, IP170
* Approved by: US D.O.T., RCRA, NATO and the US NAVY
* Approved for the ASTM specifications of recycled fuel and biodiesel
* The world wide standard in the flavors and fragrances industry
|
|
ABA 4
(air or liquid cooled)
Automatic Flash-Point Test with Closed Cup according Abel Method
The Abel-Method
describes the determination of the closed-cup flash-point of petroleum products and other liquids having flash-points between -30 °C and +70 °C.
Further possible:
- the Equilibrium-Method
- the Abel-Pensky-Method
Suitable for: Biofuel, Fuel, Paint, Solvent, Varnish
|
|
CLA 4
Automatic Flash- and Fire-Point with Open Cup according Cleveland Method
This flash-point and fire-point test method measures the tendency of a test specimen to form a flammable mixture with air.
Suitable for viscous materials having a flash-point between +79 °C (175 °F) and +400 °C (752 °F) except fuel oils.
Used to define the hazards of flammable and combustible materials used in shipping and safety regulations.
|
|
PM 4
Semi-Automatic Flash-Point Test with Closed Cup according Pensky-Martens Method
Method A:
for distillate fuels (diesel, kerosene, heating oil, turbine fuels), new lubricating oils, paints, vanishes and other homogeneous liquids.
Method B:
for residual fuel oils, cutback residual, used lubricating oils, non-homogeneous materials like mixtures of petroleum liquids & solids, surface-film building petroleum liquids or liquids with a viscosity above 5.5 cSt at +40°C. Used in shipping & safety regulations to define flammable and combustible materials.
|
|
PMA 4
Automatic Flash-Point Test with Closed Cup according Pensky-Martens Method
Method A:
for distillate fuels (diesel, kerosene, heating oil, turbine fuels), new lubricating oils, paints, vanishes and other homogeneous liquids.
Method B:
for residual fuel oils, cutback residual, used lubricating oils, non-homogeneous materials like mixtures of petroleum liquids & solids, surface-film building petroleum liquids or liquids with a viscosity above 5.5 cSt at +40°C. Used in shipping & safety regulations to define flammable and combustible materials.
|
|
|
|
|
|
Latest generation of Herzog Flash Point with proven reliability, superior design for Pensky-Martens automated closed cup testing
Designed to save time, money and bench space, HFP 339 Pensky Martens analyzer automatically determines flash point in strict compliance with the appropriate test method. In addition to standard test methods, the HFP 339 may be programmed with user-defined test protocols and test for samples with an unknown flash point. An alphanumeric solvent-proof keypad, large easy-to-read VF-Display and intuitive menu flow provide an exceptionally user-friendly interface.
To increase test productivity on products having an elevated flash point, the HFP 339 begins with an accelerated heating rate and automatically switches to the standard heating rate at the appropriate temperature to assure accurate results. Results are automatically corrected for barometric pressure and displayed on an easy to read HFP VF-Display. The last 9 results are memorized in the unit and can automatically output to an optional printer or computer system (LIM).
|
|
| ... products without technical information |
| |
The Leakage Current Tester TOS3200 is designed to perform leakage current (touch current and protective conductor current) tests on general electrical equipment but not medical electrical equipment.
It enables you to conduct tests that conform to the requirements of the applicable IEC, UL, JIS, and other standards, as well as the Electrical Appliance and Material Safety Law. The memory in the main unit stores the 51 types of test conditions laid down in the IEC/JIS standards for information technology equipment, household electrical appliances, audio, video electronic apparatus, luminaires, motor-operated electric tools, and electrical equipment for measurement and control and in the Electrical Appliance and Material Safety Law, thereby enabling you to conduct standard tests with simple panel operation.
|
|
Conventional AC test transformers are especially designed for testing objects of medium capacitance. These systems are particularly suited for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (inductive voltage transformers).
The possibility of stacking several of these transformer modules allows reaching very high voltage levels by keeping reasonable floor space.
|
|
For exponential current impulse ECI 1/20us, 4/10us, 8/20us and rectangular current impulses (RCI) and operating duty testing with current amplitudes up to 100kA.
Used in R&D testing of metal oxide surge arrestors and arrestor sections according to IEC 60099-4 and ANSI/IEEE C 62.11.
|
|
Leakage Current Measurement Essential for Electrical Safety
Automatically compatible with Networks stipulated by IEC/UL/JIS standards
Automatic measurement function (Measuring power supply polarity switching as well as the normal state / single failure state)
Stores data for 100 units
Power supply separation
|
|
OMICRON's CT Analyzer is a unique lightweight electronic multifunctional instrument designed to meet the highest standards for performing excitation, ratio, polarity and winding resistance tests on current transformers (CTs) as well as burden-impedance measurement.
Applications
- Burden measurement
- CT Winding resistance measurement
- CT Excitation characteristic recording
- CT transient behavior measurement (IEC60044-6)
- CT ratio measurement with consideration of connected burden
- CT phase and polarity measurement
- Determination of accuracy limiting factor (ALF), instrument security factor (FS), secondary time constant (Ts), remanence factor (Kr), transient dimensioning factor (Ktd), knee point voltage/current, class, saturated and non saturated inductance
- Assessment according to defined standards: IEC60044-1, IEC60044-6, IEEE C57.13-1993
|
|
The manual desktop operating terminal OT 276 allows manual, easy control of an AC test system.
The device is primarily intended as low cost, stand-alone solution for small AC source, which do not require an embedded control.
|
|
he DCT ReporteR instrument automatically tests Current Transformers reducing testing time from hours to minutes. Results can be printed out by the 40-character-wide built-in printer, or easily transferred to a PC via RS-232 and USB ports or memory-stick.
Digital Current Transformer ReporteR Features
* Tests turns ratio, polarity and phase angle
* Measures excitation values and presents results in a table or as a graph
* Calculates saturation voltage
* Tests winding resistance
* Tests insulation resistance
* Provides option to design and save customized Test Plans
* Features a built-in current source for secondary injection testing
* Outputs up to 2,000 Vac
* Easily transfer stored data to memory stick or PC via USB port
* ReporteR Software (included) makes report preparation fast and easy
* A large, color multi-language LCD screen and a keyboard
* Extensive memory for test results
* A 40-character-wide built-in printer
* Compatible with Microsoft Excel® and Microsoft Word®
|
|
| ... products without technical information |
| |
PORTACOUNT® RESPIRATOR FIT TESTER
The PORTACOUNT® PRO and PRO+ Respirator Fit Testers Deliver Fit Testing You Can Trust.
Fit testing the right way means you’re improving your risk management program while providing the best possible protection for your workers. Equally important, you’re complying with all regulations. In fact, there are specific OSHA-accepted quantitative fit test protocols written for
PORTACOUNT fit testers in the OSHA regulations. The PORTACOUNT PRO Respirator Fit Tester is more than a piece of equipment. It’s peace of mind.
No other fit tester can quantitatively fit test all types of respirators – gas
masks, SCBAs, respirators, even N95 disposable (filtering-facepiece)
respirators. If the mask requires fit testing, count on the PORTACOUNT PRO+ fit tester to provide the fastest and easiest OSHA-accepted fit test method.
It’s More Than a Fit Test. It’s Someone’s Life.
|
|
The DS2 Docking Station provides the ultimate flexibility for managing your gas monitors wherever you use them. The DS2 gives you all of the benefits of consistent automated calibration, record keeping, battery recharging and instrument diagnostics for your monitors to limit your liabilities and safety hazards. Two way wireless and/or ethernet connectivity enables you to link up to 100 stand-alone Instrument Docking Stations (IDSs) from remote locations anywhere in your facility and relay the data back to one central database for total instrument management. A graphical user interface tool (DSSAC) allows an administrator to view operations on each Docking Station from a network computer, making it easy to track instruments, print reports, set events and change parameters for any location.
|
|
|
|
|
|
The MicroDock II is the world’s most advanced, compact and affordable automatic calibration, testing and data management system for portable gas detection equipment. Compatible with BW’s GasAlertMicro 5, GasAlertMicro 5 PID, GasAlertMicro, GasAlertMicroClip, GasAlert Extreme and GasAlertClip Extreme family, the MicroDock II is expandable to up to 10 docking modules (including up to 6 charging units).
- Fully automatic “hands-free” calibration & functional bump test
- Automatically verifies performance of audible and visual alarms
- No computer required
- Entirely self-contained
- Fully portable
- Lightweight and mobile
- Operates via line power or a set of four C-cell batteries
- Add additional self-contained docking modules to system via simple, plug-in connections-no external pressure transducers or gas lines necessary
- Simplify record keeping
-Verify proper performance
- Reduce maintenance costs
- Multiple MicroDock II systems can be connected via a LAN
- Multi-language support in English, French, German, Spanish, and Portuguese
|
|
The new CheckBox IMH automates the routine gas (bump) testing, calibration and management of Crowcon portable gas detectors and facilitates the traceability and routine maintenance of instruments. Capable of operating with up to 10 instrument interfaces, CheckBOx IMH is available for use with the Tetra, Triple Plus Plus and Gasman products.
* Automatic gas (bump) testing
* Automatic calibration
* Can use single gases or quad mixtures
* Up to eight gas inlets
* Five or ten instrument interfaces
* Accommodates pumped or non pumped instruments
* Data and event file uploading
* Stores and controls configurations
* Records all activities
* Provides reports and certificates
|
|
GasCal 1100 Gas Dilution Calibrator
The Ecotech GasCal 1100 Gas Dilution Calibrator performs precise
gas dilution calibrations, ozone analyser precision checks and gas
phase titrations using an optional internal ozone generator. It is
ideal for stand alone use or incorporation into ambient air or emissions
monitoring systems.
• Single and multipoint calibrations can be performed using precise mass flow controllers
• Perform gas phase titrations (U.S. EPA Method) and ozone precision checks using an internal ozone generator (option)
• Parameter setup and output via inbuilt LCD and keypad or an external PC
• External remote control possible via data acquisition system or suitable gas analyser
• Mass flow controller zero stability drift less than 0.6 % full scale per year
• Optional Carry case allowing the GasCal-1100 to be securely carried from location to location
• Optional purge facilitates flushing of calibration gas lines
|
|