The "Record Plus" family of circuit breakers has been developed as a line of aesthetically and technically coordinated protection devices for LV distribution and control applications.
|
|
. Types: BK series, BF series, BS series, FB series, RK series
2. Ratings
(1) Miniature Circuit Breakers
1) BK series
- BKN: 1 to 4pole up to 63A & 6kA (IEC60898)
- BKN-b: 1 to 4pole up to 63A 10kA (IEC60898)
- BKH: 1 to 4pole from 63 to 125A 10kA (IEC60947-2)
2) BF series
- 6~50A Max 2.5kA at 415VAC (IEC60947-2)
3) BS series
- 6~30A, 1.5kA at 110/220VAC
4) FB series
- 3~30A, 5~50A, 60~100A, 2.5kA at 460VAC 2, 3pole
(2) Residual Current Devices: RK series
1) RKN type (RCCB): Confirming to IEC61008, Protection against ground fault, 25~63A, 30, 100, 300mA
2) RKP type (RCBO): Confirming to IEC61009,
|
|
Modular circuit-breakers up to 63A
Description
Nominal current: 1 to 63A
Large choice of breaking capacities and tripping curves: B,C,D...
Compliance with standards: IEC EN 60898 or IEC 60947-2 depending on the version, certified by national official authorities
Suitable for isolation in accordance with industrial standards: IEC 60947
Operating voltage: up to 440 Vac, insulation voltage: 500V
Optional add-on earth leakage modules: C60 Vigi
Optional auxiliaries: indication of state and tripping, shunt trip, undervoltage trip, overvoltage trip
|
|
|
|
|
|
Low voltage moulded case circuit breakers are used for the switching and protection of power supply cables, motors
and other electrical equipment against overloads and short circuit faults. It provides, beside protection function other
functions as remote ON/OFF operation, undervoltage protection, main switch, ...
They are available in range from 16 A up to1600 A in 3 and 4 pole versions.
Advantages:
- Small dimensions,modular sizes
- Possibility of field-instalable accessories - up to 630 AF series 2
- High short circuit breaking capacity (up to 100 kA)
- Fast break mechanism (F.B.M.)
- Reduced energy let throught I2t - minimises thermal stresses
- Reduced tripping time - minimises damage after fault
- Reduced peak short current ampacity - minimised electrodynamic stresses on conductors and
protected equipment
- Installation on mounting plate, 125 AF also on DIN-rail
- Wide range of accessories
- Compact design with high mechanical strenght
- High withstand voltages (8 kV a.c.)
- Voltage level up to 690 V a.c. and 250 V d.c. - only MCCB's with thermal-magnetic triping unit
- Direct opening - recommendation according to standard IEC 60204-1 - up to 630 AF series 2
- Common internal accessories - up to 630 AF series 2
- Visual safety
- Unsurpassed flexibility
|
|
|
SN moulded case circuit breakers are used for switching and protecting low-voltage installations in larger residential properties and business as well as industrial buildings. They ensure reliable protection against overload and short circuits, and can also be used as a main disconnection switch. Rated currents of SN moulded case circuit breakers are in the range from 16 A to 1600 A.
|
|
|
|
|
|
Record Plus™ Thermal Magnetic Trip
3 to 100A. The FC100 and FB100 Record Plus breakers provide a new standard of performance offering multiple levels of interruption capacities, global code approvals, compact size, dual AC/DC ratings, and a broad range of accessories.
Record Plus™ Electronic Trip
125 to 600A. The FG600 Record Plus breaker offers the highest short circuit ratings in the industry, all in a traditional 400A frame.
Spectra RMS™ Electronic Trip
15 to 1200A. These industrial SE150, SF250, SG600 and SK1200 breakers have a digital, solid state, RMS sensing trip system with field installable, front-mounted rating plugs to establish or change the breaker ampere rating.
Thermal Magnetic
15 to 1200A. Our industrial thermal magnetic E150, F225, J600 and K1200 breakers provide a proven, cost effective solution.
Mag-Break® Motor Circuit Protector
Magnetic only circuit breakers. Available in frame types E, F, J, K, and Tri-Break.
Lighting Circuit Breakers
15 to 100A. TEY breakers available with plug-in or bolt-on mounting options.
|
|
|
|
|
|
The majority of distribution systems are designed to an ultimate circuit rating (lcu). An lcu rated MCCB provides the optimum protection in terms of safe and economical selection.
Certain applications may require protection wich is designed to the more onerous service short circuit rating (lcu).
Terasaki's TemBreak Plus range can provide a wide choice of MCCBs with superior lcs ratings up to 85kA at 440V AC.
lcu=o-co 2 full short circuits
lcs=o-co-co 3 full short circuit
All TemBreak Plugin and drawout MCCBs are fitted with a safety trip as standard. If an attempt is made to remove an MCCB while ON it will automatically trip.
The neutral pole of all TemBreak MCCBs are of early make / late break design. This eliminates the risk of abnormal line to neutral voltages which may damage sensitive electronic equipment.
TemBreak MCCBs from 125AF to 1600AF are suitable for isolation as defined by IEC 947-2. Positive Contact Indication (PCI) is achieved via the toggle mechanism. Padlocks can only be installed if the contacts are fully open or closed.
|
|
RCCB Record Plus: FD63/160 frame size
Rated at 160A, the FD63/160 frame size is designed for use in both a DIN-rail environment with modular equipment and in industrial applications. It is supplied with IPXXB terminals suitable for direct connection of one or two conductors totalling up to 95 mm² and is available as a thermal-magnetic breaker, a moulded case switch, and as a magnetic-only motor circuit protector.
The FD63/160 bridges the gap between residential miniature circuit breakers and industrial moulded case circuit breakers.
In compliance with EN 60947, BS, VDE, UTE, KEMA, CEI
3 and 4 pole versions available
FD63 to 63A and FD160 to 160A
Full range of add-on accessories, including:
thermal magnetic/magnetic trip units
auxiliary contacts
completely integrated add-on devices available
rotary handles
electrical operators
connectivity - 60 mm system
|
|
1. General
Meta-MEC MCCBs shall comply with IEC 947-1 and 947-2 standards or with the corresponding standards applicable in the
member countries (EN 60 947-1, 2) :
- Rated operational voltage of 600 V AC (50/60 Hz)
- Rated insulation voltage of 690 V AC (50/60 Hz)
- Suitable for isolation, as defined by IEC 947-2
- ISO 9000 standard.
2. Types & Ratings
- AB type, GB type, UL listed type
- It covers all ratings from 3A to 1600A.
3. Application
- Line protection
- Motor/generator protection
- Starter combination
4. Type of trip unit
- Thermal-magnetic release
- Electronic release
- Hydraulic-magnetic release
- Magnetic release only without thermal trip
5. Certification: KEMA CB certification, CE document of conformity, UL, CCC
|
|
630 A to 3200 A moulded case circuit-breakers
Description
Nominal current from 630 to 3200 A
2 breaking capacities:200kA at 440V - 75kA at 690V for 630 and 800A LB frames
4 breaking performances from 50 to 150 kA at 415 V
Voltage rating:up to 690 V
2 physical sizes from 630 to 3200 A
A single pole pitch of 70 mm
3 and 4-pole versions
solation with positive break indication
4 Micrologic control units enriched by measurement, energy management and network analysis functions
Earth leakage protection built into electronic protection Wide range of common auxiliaries and accessories interchangeable on site
Compliance with international standards IEC 60947-1 and 2, IEC 68230 for type 2 tropicalisation
Compliance with specifications of marine classification companies:Bureau Veritas, Lloyd’s Register of Shipping, Det Norske Veritas, etc.
|
|
|
|
|
|
The TemBreak series offers the models of the 800A to 1600A frames with the breaking capacity up to 125 kA, and this series consists of thermal adjustable type and electronic type that allows you to select the most suitable breaker for your system
Features of the TemBreak Electronic Moulded Case Circuit Breaker:
- Long time delay trip, short time delay trip, and instantaneous trip are available as standard.
- All of long time delay trip, short time delay trip, pretrip alarm, and ground fault trip can be adjusted. The rated current can be adjusted in a range between 50% and 100%. For short time delay trip, ramp characteristics can be selected with the switch to enable selective coordination with lower breakers and fuses.
- The multi-protective device uses the r.m.s. value control. It samples peak current every 0.5msec. to calculate a root-mean-square value. Therefore, harmonics up to 19 th harmonic are accurately detected at 50 Hz to prevent any malfunction from occurring due to harmonics.
|
|
|
Motor protection switch with higher switching capacity and up-to-date supplements. Fifteen adjustable ranges cover current area from 0.1 to 32 A. Due to high switching capacity, the additional protection from short circuits is required rarely.
|
|
Enclosed DOL starters, safety switch disconnectors, thermal-magnetic motor circuit breakers
Description
TeSys wall-mounted DOL starters LG, LJ
Enclosed DOL starters are used to control starting or stopping of the machine
TeSys motor-starter solutions incorporate 2 auxiliary contacts which allow them to be integrated in safety wiring diagrams
TeSys Vario switch disconnectors
Installed on an enclosure or in a cabinet, these rotary control switch disconnectors act as circuit load breakers
Available in open or enclosed version
Fixed on the front panel or DIN rail mounted
Padlockable versions
Thermal-magnetic motor circuit breakers TeSys GV2-ME
|
|
Modular circuit-breakers for the protection of motor supply circuits
Description
Rating current:4 to 80 A
Breaking capacities:50kA under 380/415 V
Tripping curves:MA (short -circuit protection to combine with suitable overload protection)
Compliance with standards: IEC 60947-2, certified by national official authorities; NG125LMA + Telemecanique contactor and thermal relay combination in compliance with IEC 60947-4
Suitable for isolation in accordance with industrial standards:IEC 60947
Operating voltage:up to 500 Vac, insulation voltage:690V
Optional add-on earth leakage modules:Vigi NG125
Optional auxiliaries:indication of state and tripping, shunt trip, undervoltage trip, overvoltage trip
|
|
Power Break II Insulated Case Circuit Breakers are highly compact, heavy-duty breakers that combine ease of use, asethetics and state-of-art performances in 200 through 4000-Amp frame sizes, rated for up to 200,000 Amps RMS symmetrical for 240Vac, in drawout and stationary versions.
Now available with the new EntelliGuard® TU Trip Unit which provides excellent selectivity and arc flash energy protection.
Features and Benefits
* Compact, Lightweight design
* Modular, drop-in accessories common to all frame sizes
* Flush-Mounted pump handle
* Manually and electrically operated versions in same compact envelope
* Double Insulated ON/OFF buttons
* 72-point pre-wired , dedicated secondary terminals
* Modular, field-installable motor operator
* EntelliGuard TU Trip Unit featuring Reduced Energy Let-Through (RELT) setting
* Modular auxiliary switches with up to 12 NO/NC set of contacts
* Charge-after-close mechanism
* Manual discharge of springs without closing
* Suitable for reverse feed™
|
|
|
|
|
|
High Performance Circuit Breakers:
410
Thermal-magnetic circuit breakers,
various mounting methods, toggle operated
412
Thermal circuit breaker with threadneck
mounting and push-pull actuation
413
Thermal circuit breaker with threadneck
mounting and push-pull actuation
428
Thermal-magnetic circuit breaker,
plug-in type, with manual release button
437
Thermal-magnetic circuit breaker
with remote trip coil, toggle operated
446/447/449
Thermal-magnetic circuit breaker, base
mounting, special dual button manual release
452
Thermal-magnetic circuit breaker with
threadneck mounting and push-pull actuation
482
Thermal circuit breaker with threadneck
mounting and push-pull operation
483
Thermal aircraft style circuit breaker,
temperature-compensated and explosion-proof
4120
Thermal circuit breaker with threadneck mounting, temperature-compensated and explosion-proof
4140
Thermal circuit breaker with threadneck mounting, single pole, robust design
4930
Remote control circuit breaker, single pole, temperature-compensated
5140
Thermal circuit breaker with threadneck
mounting, three-pole, robust design
520/530
Thermal-magnetic circuit breaker with toggle actuaction, double pole (520) or three-pole (530)
583
Thermal circuit breaker with threadneck mounting, temperature-compensated and explosion-proof
|
|
Residual current circuit breakers EFI are used for protection against indirect touching of parts under voltage, for
prevention of lasting voltage on earthed parts which should appear because of a defect in the electrical installation
and for protection against direct contacts of parts under voltage in case of I < 30mA. Residual current circuit breakers
can be used in TN-S, TN-C, TT and IT network systems or with other words in all systems where neutral and protective
conductor are separated (VDE 0100 Teil 410).
Types - Our programme comprises residual current circuit breakers which are sensitive to alternating residual current
(AC-type) and residual current circuit breakers which are sensitive to alternating and pulsating direct current (A-type).
|
|
|
With a residual current circuit breaker (RCCB) the following protective measures are available: fault protection, protection against fire and additional protection in case of direct contact.
|
|
Residual current circuit breakers up to 125A
Description
Nominal current:1 to 125 A
30mA sensitivity:additional protection against direct contact (in accordance with IEC 364)
100, 300, 500 mA sensitivities:additional protection against fire and indirect contact (in accordance with IEC 364)
B type:protection of installations with three-phase rectifier
Type "si": protection of sensitive circuits (computing equipment) and those prone to disturbances (ballast lighting, power electronics)
Selective version :tripping of the device the closest to the fault
Compliance with standards:IEC EN 61008 certified by national official authorities
Suitable for isolation in accordance with industrial standards: IEC 60947
Operating voltage:up to 440Vac, insulation voltage: 500V
Optional auxiliaries:indication of state and tripping, shunt trip, undervoltage trip, overvoltage trip
|
|
The PolyZen device is a thermally protected, precision Zener diode that helps protect circuits from overvoltage & overcurrent fault conditions.
|
|
Actuator Style = Push to Reset
Button Color = Black
Termination Type = 6.35 [.250] Straight Quick Connect Tab
Current Rating (Amps.) = 10
Operating Voltage, Max. = 32 VDC, 250 VAC
Number of Poles = 1
Trip Time at 200% = 2.2 to 15 Seconds
Interrupt Capacity = 1,000 A @ 32 VDC or 250 VAC
Mounting Options = Snap-In Panel Mount
Approved Standards = UL Recognized, SEV Approved, VDE Approved, Demko Approved, CSA Certified
|
|
104
Thermal circuit breaker, integral type, single pole
104-PR
Thermal circuit breaker for pcb mounting, single pole
105
Thermal circuit breaker for snap-in mounting, single pole
106
Thermal circuit breaker for threadneck panel mounting, single pole
127
Thermal circuit breaker with manual release button, plug-in or snap in panel mounting
129-L11-H-KF
Thermal automotive circuit breaker with manual release, for base mounting
157/158
Thermal single pole circuit breaker, threadneck panel mounting or integral type
1110
Push-push thermal switch/circuit breaker combination, single pole
1140-E
Single pole thermal circuit breaker, integral type
1140-F
Thermal circuit breaker for snap-in panel mounting, single pole
|
|
Application Flexility
In Switchboards , motor control centers and lighting and in power panelboards. General Electric molded case Circuit breakers are being used to provide reliable circuit protection. Molded case circuit breakers in individual enclosures are also being used in numerous applications
Minimum Downtime
Downtime is reduced and fuse replacement is eliminated with circuit breakers. In case of overload or short circuit, the breaker trips, opening the circuit and protecting the conductors. When normal conditions are restored, the breaker can be closed("ON") again.
Features and Benefits
* Molded Case
* Thermal Magnetic Trip
* Proven Reliability
* Provide Cost effective Solutions
* Multiple types to fit in your application
|
|
|
Loadline Y-Frame MCCBs span a range of current ratings from 20A to 1600A in just 6 modular frame sizes. All electronic Y Frame devices comply with IEC 947-2 selectivity utilisation category B, and all frame sizes are complete with a full range of accessories including shunt trips, under voltage releases, auxiliary contacts, pre-trip alarm contacts, earth fault protection, motor operators, terminal covers, rotary handles and plug-in capability. The advanced technologies employed within the range ensure problems caused by harmonics, DC applications, temperature rise and discrimination / selectivity issues can be easily overcome by simple selection of the appropriate device.
|
|
|
|
|
|
201
Thermal-magnetic circuit breaker for rail mounting, low resistance option
2210-S2
Thermal-magnetic circuit breaker, socket or panel mounting, single or multipole
2210-S291
Thermal-magnetic circuit breaker, single pole, with auxiliary contacts
2210-T2
Thermal-magnetic circuit breaker for rail mounting, single or multipole
2215-L
Thermal-magnetic circuit breaker, small width, pcb or threadneck panel mounting
2215-G
Thermal-magnetic circuit breaker, small width, threadneck mounting
2215-F1
Double pole thermal-magnetic circuit breaker, pcb or flange mounting
3120-...-M...
Rocker actuated thermal-magnetic circuit breaker, snap-in mounting
3120-...-M...
Push button operated thermal-magnetic circuit breaker, snap-in mounting
3120-F7..-M...
Rocker-actuated thermal magnetic circuit breaker, snap-in mounting, new design
3200
Plug-in type thermal-magnetic circuit breaker with manual release facility
3300 fast acting
3400 standard delay
Thermal-magnetic circuit breaker with auxiliary contact option, threadneck mounting
3500 standard version
4000 low resistance version
Thermal-magnetic circuit breaker with manual release facility, flange mounting
3600 standard version
3900 low-resistance verson
Thermal-magnetic circuit breaker with auxiliary contacts, socket mounting
|
|
Indoor medium voltage switches
Vacuum circuit-breaker type V...
according to IEC 62271-100 + A1
• Rated voltage 12 kV, 24 kV, 36 kV and 38.5 kV
• Rated current 630 A, 1250 A, 1600 A and 2000 A
|
|
Power/Vac® Vacuum Breakers
1200 to 4000A. GE pioneered this interrupter technology beginning with experimental work in the 1920's. Today, the vacuum design remains superior to other arc interruption technologies by providing a smaller footprint and simpler design.
Power/Vac® Replacement Vacuum Breakers
1200 to 3000A. GE Power/Vac® Vertical Lift (VL) breakers provide an economical and efficient way for customers to upgrade existing GE Magne-Blast Type AM (Air Magnetic) vertical lift circuit breakers.
Power/Vac® Vacuum Distribution Breakers
200 to 1120A. GE's outdoor distribution breaker uses the same proven vacuum interrupter technology as found in GE's Power/Vac breaker installed in metalclad, medium voltage switchgear.
Power/Vac® Vacuum Distribution Recloser Breakers
200 to 1120A. The GE Distribution Recloser helps customers maximize uptime and minimize outages by clearing non-persistent or temporary overhead faults.
|
|
- For use on closed vessels and piping systems to
control induced vacuum within safe limits
- Adjustable from 1/4" - 20" (8-508mm) Hg vacuum - factory
set at 2" (51mm) Hg vacuum
- 3/4" NPT straight shank
- Maximum operating temperature 366°F(186°C)
- Maximum operating pressure 150 psig (10.3 bar)
|
|
|
|
|
|
1. General
1) High reliability of the operating mechanism
- Separate design of the main circuit from the operating mechanism.
- Adopt the toggle link method.
- Improved the reliability of electric circuit.
- Adopt the rapid auto-reclosing method as a standard option. (O-0.3sec.-CO-3min.-CO)
2) High interrupting performance
- Make short of the interrupting time. (3cycles)
- Increase the rated short-circuit withstand characteristics. (1sec. to 3sec.)
3) Great operational safety
- Reinforce the insulation in the conduct, by adopting the molded housing in each phase.
- Built in the device making the contacts open first when draw in and out.
- Adopt the tulip-shape connection between the cradle and the VCB.
2. Type: LVB
3. Ratings
- Rated voltage: 7.2kV, 12kV, 17.5kV, 24kV
- Rated normal current: 630A, 1250A, 2000A, 2500A
- Rated short-time withstand current: Max. 40kA
4. Wide range of accessories (optional)
5. Applied standard: IEC 62271-100 (M2, E2(List1), C2 class)
6. Certification: KEMA, KERI
|
|
|
Yaskawa SF6 gas rotary-arc circuit breakers are rated for applications in power generating plants, substations, and industrial plants at 3.6kV to 15kV. Yaskawa SF6 gas rotary-arc circuit breakers are safer to operate than vacuum and other competitive types because a two-stage pressure switch in each of the interrupters continuously monitors the gas pressure. This series of Yaskawa SF6 gas rotary-arc circuit breakers offer excellent interrupting characteristics, comparable to air-magnetic breakers, with continuous current ranging from 600 to 3000 amps. In addition, the surgeless nature of the current interruption eliminates the need for surge arrestors to dampen voltage spikes related to current chopping and switching surges. This feature makes the Yaskawa SF6 gas rotary-arc circuit breakers ideal for the protection of motors, capacitors, and transformers. This series of circuit breakers conforms to applicable ANSI, IEC and JEC st
|
|
|
|