• Functions: emergency stop, two hand, contacts expansion, many
configurations available
• Power supply: 24Vac/Vdc;115,230Vac
• Safety category: 2, 4, IIIA, IIIC
• Dimensions: modular 22,5, 45mm
• As per CEE machine directive 89/392/CEE
• Norms: IEC 204-1, EN 60204-1, DIN/VDE 0113 |
|
Take control of electrical safety
... with PMDsrange electronic monitoring relays
For electrical safety such as voltage or true power monitoring, electronic PMDsrange monitoring relays provide the optimum solution.
Complete machine control – Standard-compliant and safe
… for stand-alone machines and plants with up to 14 safety functions
PNOZ safety relays :
Use PNOZ safety relays for stand-alone machines and plants with up to 14 safety functions. You can use these to monitor functions such as E-STOP, safety gates, light curtains/light grids and many more, safely and in compliance with the standards
A wide range of safety applications are now available to customers :
- Safety relays PNOZ X
- Electronic safety relays PNOZelog
- The modular and freely configurable electronic safety system PNOZmulti
- The new PNOZ, PNOZsigma, with particularly narrow housing widths and multifunctionality compressed into each unit, represents maximum functionality in minimum width... |
|
| Safety-implemented circuits must be control reliable as mandated in U.S. and European standards. Control reliability is not provided by simple redundancy. There must also be monitoring of the safety circuitry to assure that redundancy is maintained. Monitoring may be achieved by using Omron STI safety monitoring relays that range in function from two-hand palm button control to dual channel input units with time-delayed outputs that conform to ANSI B11.19-2003, Section 6.1 for Performance of the Safety Related Function(s). All safety relays carry the CE mark and are designed to incorporate three points of safety in their operation to meet both European and U.S. requirements. All safety relays are UL and C-UL listed. |
|
Multifunction Safety Units (MFUs) provide relay output switching capability. They are typically used in conjunction with the 1000 Plus Series range of safety light curtains, which incorporate two fail-safe, electronic output switches as standard. In addition to providing relay outputs they also provide additional functionality including muting, E-Stop inputs, manual / auto restart and external device monitoring (EDM).
Features:
- Suitable for a wide range of machine safeguarding applications
- Safety monitored output relays
- Safety integrity classification up to EN 954-1 - Category 4
- Simple installation
- External Device Monitoring (EDM)
- One year manufacturers warranty
- DIN Rail mounting - 70 mm enclosure
- LED status indicators
- Reset function
- Dual inputs for connecting emergency stop circuit
- Simultaneous monitoring between related channels
- Connect up to 2 light curtains
- Dual mute inputs
- Auxilliary electronic output for status indication
Product Range:
011-149 Safety relay outputs with dual safety light curtain inputs
011-150 Safety relay outputs with two dual safety light curtain inputs and E-Stop connection
011-151 Safety relay outputs with dual light curtain inputs and dual mute inputs
011-154 Safety relay outputs with dual light curtain inputs and dual mute inputs and mute enable |
|
Safety gate switch with mechanical internal release and safety key adaptor
The ATIRAS1STOP has a heavy duty tongue and head that can rotate in 90o increments. The tongue allows for a +/- 12mm misalignment. It features LED status indication and is suitable for both. The internal release
mechanically overrides the safety switch in case of an emergency.
- heavy duty tongue and actuator
- designed for use in harsh environments (dust, moisture and vibration)
- different control voltages available
- AS-interface version available
- mechanical internal release function
- available with different heads and actuators
- safety keys (to prevent accidental lock in of personnel)
- for use in category 4 (EN 954-1) applications |
|
Safety switches FR series
Pizzato Elettrica switches of the FR series with separate actuator reach the 4th generation. These switches are ideal for gates, protections, carter and all different guards which protect dangerous parts of a machine. The stainless steel actuator is fixed to the mobile section of the protection in order that every time the protection is opened the actuator is pulled out of the switch. A particular mechanism assures the positive opening of the electrical contacts by the pulling out of the actuator. These switches are easy to install and can be applied to any type of protection (hinged, sliding or removable). Furthermore the possibility of operating the switch only with the specific actuator assures that the machine can start again only when the guard is closed.
Pizzato Elettrica switches of the FR series distinguish themselves for the following characteristics:
• Rotating heads: by unscrewing the fixing screw the head can be rotated in 90° steps.
• Not detachable heads: the head “93” is perfectly interchangeable and compatible with the previous head “92” but it has the advantage that it is not detachable from the body, nonetheless it can rotate in 90° steps (Pizzato Elettrica patent). Practically speaking the new head is safer because it’s not possible to damage it during the installation.
The FR series complements the range of products that Pizzato Elettrica can offer to its customers. For further information, please visit the website www.pizzato.com or ask for the relative documentation. |
|
These safety switches are suitable for hinged safety guards, which need to be closed to ensure the necessary operational security.
The variety of requirements to be found in practice can be met by means of the wide range of safety switches for hinged guards.
Depending on the particular version of the switches, small doors and service flaps as well as heavy hinged doors on engineering machines and plants can be protected in such a way as to provide for easy setting up and maintenance.
Design and mode of operation:
A general advantage of the safety switches shown here is the integral cam within the safety switch. The requirements of EN 1088, such as positive linkage between cam and actuator as well as protection against tampering are thus fulfilled.
This combination within the switch provides cost advantage for the user in avoiding the necessity of mounting a specially designed cam.
These safety switches are mounted with slow action.
Protection class of all the safety switches is IP 67 |
|
These safety switches are ideal to control gates, sliding doors and other guards protecting dangerous parts of machine. The stainless steel actuator is fastened to the moving part of the guard, so it is removed from the switch on every opening of the guard. The switch mechanism guarantees that removing the actuator forces the positive opening of the electrical contacts. Easy to install, these switches can be applied to any kind of protection (with hinge, sliding and removable ones). Besides, the possibility to actuate the switch only with its actuator guarantees that the machine can be restarted only when the guard has been closed.
- Polymer housing, three M20 or M16 knock out conduit entries
- Protection degree IP67
- 6 contact blocks available
- 8 stainless steel actuators available
- 30 N actuator extraction force versions
- Silver contacts gold plated versions
- Cylindrical or slotted fixing holes
- Cover with hinged opening and with only one fixing screw. |
|
Application:
Safety switches with separate actuator are suitable for sliding, hinged and particularly removable safety guards, which need to be closed to ensure the necessary operational security. They are also suitable for fitting on profile sections and existing equipment.
In combination with safety control modules all safety switches with class 2 shown in this chapter achieve Control Category 3 or 4 to EN 954-1.
Design and mode of operation:
On the safety switches with class 2, the switching element is not physically connected to the actuator but functionally brought together or separated for switching. When the guarding device is opened, the actuator is separated from the base unit. In the process, NC contacts are positively opened and NO contacts closed.
Enclosure rating of all the safety switches is IP 67. The safety switches can be fitted in any desired mounting position.
Schmersal make both standard and AS-i Safety at Work safety switches with separate actuator.
Or for the standard models click below
|
|
When actuated, tactile safety monitoring devices stop the hazardous movement. The diversity of applications requires constructively different devices.
The safety edges of the SL range are suitable for safeguarding crushing and shearing points, that can be present on guards, lifting tables and platforms, mobile storage shelving, operating process tables, storage lifts, lift doors, loading ramps, lifting and tilting devices or industrial gates. They immediately stop the dangerous movement, thus preventing injury or destruction.
The safety flaps of the SL 300 range are designed for the protection of man and machine at machines with wide material input or feed areas.
The safety mats of the SMS 3 range are used to protect surfaces in danger zones on machines and plants with dangerous movements. Depending on the shape of the area to be protected, multiple safety mats can be electrically connected. When the safety mat is actuated, a signal is evaluated and the machine stop is initiated.
In combination with a connected safety-monitoring module, the three above-described systems achieve control category 3 or 4 to EN 954-1.
|
|
| The ShockWatch EquipManager™ is a wireless fleet management system that ensures OSHA compliance, controls access, detects impacts, and monitors equipment operation to improve safety while reducing damage-related costs. |
|
Ratings 25 - 125A three and four pole
Comply with IEC 947-3 AC23 utilisation category
Disconnecting electrical equipment from the main
Visible indication of contacts status (when operation handle is in the 'OFF' position all contacts are open)
Red/Yellow emergency stop operating handle
Handles padlockable in the 'OFF' position
Front and rear mounting options
Special emergency stop switches with undervoltage release available
Enclosed versions available
Wide choice of accessories : terminal shrouds, black/grey operating handles, auxiliary contact blocks, fixed and switched neutral add-on contact poles, shaft extensions for greater panel depth operation
|
|
Safely equipped for all cases
According to EN 292-2 (Machine safety), movable guards must be provided with safety switches. Protective door bolts for protective devices work in tandem with SICK safety switches. On deliberate opening of the protective device, the N/C contact of the safety switch is opened and the hazardous motion of the machine is brought to a standstill.
Developed for harsh industrial everyday use
SICK products easily withstand harsh conditions such as impacts and vibrations. Opening, closing and locking is reliably guaranteed over a long lifetime. SICK safety switches are available in plastic or metal versions.
|
|
Ex-Safety and Main Current Switches
CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility for up to three padlocks in the OFF position.
To prevent manipulations, the enclosure covers cannot be opened in the locked position without destroying the enclosure itself.
All CEAG safety switches feature full AC-3 motor switching capacities and isolating properties according to EN 60947-4-1 with compulsory opening of the main current contacts; optional EMERGENCY STOP versions according to EN 60204-1 are also available. |
|
| The industry's most complete line of contact and non-contact products. GE Security Industrial safety interlock switches are used to detect the opening of guards-including doors, gates and/or removable covers-that prevent access to dangerous parts of a machine, and to help deter tampering with the guards or the internal machine controls. As with all GE Security Industrial 300-BT products, the safety interlock switches are in full compliance with the most current and required standards. These include IMQ, CE, VDE, UL, CSA, IEC, EN and Semi S2 standards. |
|
Safety switches are used to detect the opening of machine guard doors, gates or panels and to prevent physical access to dangerous areas of the machine. Safety switches are designed to help deter tampering with either the internal machine controls or guards while in an unsafe condition.
All mechanical safety switches are equipped with positive opening contacts that open any normally closed contacts to assure machine shutdown when an unsafe condition is detected. |
|
Muting sensors / Muting lamp / Start button directly connectable
1 - 4 cycle control
programming of blanking functions
restart interlock / valve control
provides Muting function
minimum cable requirement - saves costs expenditure
additional internal Muting lamp
snap-on controller for the light curtain / light grid
PLSG 2 / PLSG 3 with LCD display for easy diagnosis and programming
|
|
| The LarcoMat EuroSystemª Machinery Safeguarding system has been third-party tested and certified by the BIA in Germany and SAQ in Sweden to be in compliance with all appropriate EN standards and is deemed "CE" compliant. The Larco EuroSystem is certified as a Category 3 Safety System in accordance with EN 954. A EuroSystem consists of one or more Larco "CE Series" safety mats, a Larco AZR31 series Mat Control and a "Total Activation Trim Kit." |
|
UE410 Flexi modular safety controller:
safety perfectly managed
- Optimised for the linkage of up to
approx. 10 safety operations
- Simple parameterisation with a screwdriver
(no software required)
- Integrated functions: And / Or / Muting / Bypass
- Optimum integration of SICK safety sensors
- Safety relay and semiconductor outputs
For packaging, machine tools, placement and
handling machines |
|
| The FailSafe GuardSwitch is designed as a safety interlock to be attached to a machine's guard or door. Unlike a standard reed switch interlock, the circuit has been designed to have an "open" failure mode. If the main reed sticks closed when the guard opens, the in-line fuse will blow, opening the circuit. If the watchdog reed sticks closed when the guard closes, the in-line fuse will blow, opening the circuit. The circuit will draw up to 4.5A to blow the fuse in less than 200ms. Along with being FailSafe, all the 200 series switches have non-coded actuators. |
|
UE410 Flexi modular safety controller:
safety perfectly managed
- Optimised for the linkage of up to
approx. 10 safety operations
- Simple parameterisation with a screwdriver
(no software required)
- Integrated functions: And / Or / Muting / Bypass
- Optimum integration of SICK safety sensors
- Safety relay and semiconductor outputs
For packaging, machine tools, placement and
handling machines |
|
The Pressbrake safety System AKAS meets the safety requirements of category 4 according to EN 954 and
prEN 61496, and the most recent requirements of prEN 12622.
Innovative finger guarding system for pressbrakes by following LASER optical safety light grids in front of the tool.
Finger guard works during the foot pedal controlled bending process => hands remain free for the operation with the slug.
Increase of productivity due to programmable adaptation of the AKAS® II to the individual overrun traverses of the machine.
Short change-over times due to all-automatic change-over to other tool sizes.
|
|
Advantages
Pneumatic clamping with high forces
Optimum safety clamping - if the pneumatic fail the system is locked
The values of hydraulic clamps are reached and exceeded
Low system costs in comparison to hydraulics
Simple installation
Compact design
Wide range for many shaft sizes can be delivered |
|
Forklifts account for thousands of serious injuries and dozens of deaths each year in North American workplaces. According to statistics reported to government inspectors by employers, every year 100 workers are killed and 20,000 seriously injured in forklift related accidents. Many more have sustained severe, life long injuries. Many accidents are due to overloading. Employers eager to increase efficiency at the expense of safety, encourage excess loads which can cause the forklift to tip over. In other cases workers are crushed when load limits are exceeded and materials fall.
Although, there are more than a million forklifts in use at construction sites, warehouses and businesses across the country, many of these machines are not properly maintained or equipped for safety. Equipment failure and poor maintenance procedures cause many preventable accidents.
Forklifts should be equipped with adequate safety systems including a simple on-board load weight overload indicator.
SM-(Range) Analog: Up to 12000
ED2-SM Digital: Up to 50000 |
|
Door interlock switches are attached to the door of equipment where it is necessary to turn power on or off when the door is closed or opened. This type of control is used in applications where maintenance and testing must be performed inside a cabinet.
Interlock switches are supplied with one 1PDT snap action switch or two 1PDT miniature snap action switches.
The snap action switches are mounted in a frame and a single actuator, which is spring loaded, operates the switch.
When mounted in a door, the closing of the door forces the actuator against the spring thereby closing the switch.
When the door is open, the actuator springs out thereby opening the power circuit. The interlock switch has a service position, which allows service personnel to turn power on even when the cabinet door is open. When the door is closed, the switch automatically resets to the normal closed position.
Ratings:
See selection table.
Operating Features:
Free position - 9.53mm (.375²) max.
Operate position - 5.12mm (.203²) max.
Depressed position - 3.17mm (.125²) max.
Materials and Finishes:
Switch - Contact Eaton Customer Service.
1-800-962-0820
Bracket - Stainless steel.
Actuator - 1 Pole - Molded noryl; 2 Pole - stainless steel.
Spring - Stainless steel.
Insulator - Glass cloth.
Mounting:
Tapped holes are provided for mounting in either of two positions - 2 screw side or front panel mounting.
Mounting hardware is not provided.
Options:
Special circuits.
Solder lug, spade, and PC terminations.
Special actuators.
Approvals:
UL Recognized.
CSA Certified. |
|
| The FailSafe GuardSwitch is designed as a safety interlock to be attached to a machine's guard or door. Unlike a standard reed switch interlock, the circuit has been designed to have an "open" failure mode. If the main reed sticks closed when the guard opens, the in-line fuse will blow, opening the circuit. If the watchdog reed sticks closed when the guard closes, the in-line fuse will blow, opening the circuit. The circuit will draw up to 4.5A to blow the fuse in less than 200ms. Along with being FailSafe, all the 200 series switches have non-coded actuators. |
|
| The 100 Series are non-contact interlock position switches with switching voltage models available up to 250 Volts. There are many models to fit a wide variety of applications. |
|
| Stricter safety regulations, and the need for tamper-proof safety at work, now make modern safety switches indispensable. Interlock expertise from SICK opens up numerous new opportunities for use. |
|
|
|