This Outdoor high performance disconnectors are manufactured for high currents und difficult environmental conditions. That means high pollution degree up to PD4 and high operating cyles.
Tecnical data up to 38.5 kV, 4000 A, 31.5 kA.
Special field of applications are electic power transformation substations, steel- or mine mills.
All switches can be equipt with manual- or motor actuator, automatical earthing device and auxiliary contacts.
|
|
DRIESCHER Indoor Switch-disconnector H 27
• 3-pole
• Rated voltage 12 kV and 24 kV
• Ratec current 630 A
For frontpanel mounting or mounting besiede with or without actuating.
All switches are generally equipped with quick make and quick break operating mechanism.
The switches are designed for normal operating conditions according to DIN VDE 0670, Part 1000, class Minus 5° Indoor.
The peak value of the ambient temperature is 40O C; the average value over 24 hours is 35° C at best.
The values of the insulating power are related to sealevel.
Reduction in insulating capacity at hights up to 1000 m are negligible due to the decreasing insulating capacity of the air.
Refer to brochure 727
|
|
DRIESCHER - Indoor Disconnectors, Fuse Bases, Earthing Switches
• Rated voltages Ur
12 kV, 24 kV, 36 kV and 38,5 kV
• Rated currents Ir
630 A, 1600 A, 2500 A, 4000 A and 6300 A
The 1-, 2- and 3-pole Disconnectors ITr are applicable for a rated voltage range of 12 kV, 24 kV, 36 kV, 38,5 kV and a rated current range from 630 A
to 6300 A.
The rated short time current upto 63 kA for a duration of 3 s depending on the model has been tested.
The 3-pole Earthing Switches ES can be used for a rated voltage range of 12 kV, 24 kV, 36 kV and 38,5 kV.
A rated short time current of 20 kA and 31,5 kA is specified.
The described Disconnectors are intended for currentless switching in medium voltage switchgear.
All switchgears are type-tested according to EN 62271-102.
For each switchgear an instruction manual for transportation, mounting and commissioning is inclosed. This instruction manual should be
strictly followed. Refer to brochure 731e
|
|
|
|
|
|
Rated voltage 12, 24, 36 and 38.5 kV
Rated current 630 A and 1250 A
Switch-fuse combinations are used for operational medium voltage-side on and off switching of distribution transformers in secondary substations. They additionally have the task of protecting these transformers against the impact of internal and external faults.
These combinations comprise a functional unit of switch disconnectors and back-up fuses.
By means of the fuses the breaking capacity of the combination is extended beyond that of a simple switch disconnector up to the rated short-circuit breaking current.
The high-voltage high breaking capacity fuse, according to statistics of the VDN (German Association of Electricity Network Operators) is rated as reliable transformer protection. The h.v.h.b.c. fuse in combination with a switch disconnector provides a simple solution which is very economical to procure and run.
This provides a clear-cut advantage over a circuit breaker with the associated current transformers and overcurrent time protection.
Besides this, the h.v.h.b.c. fuse has a current limiting effect when short-circuits occur and reliably interrupts the fault current of the first half cycle.
These properties are advantageous for the dimensional design of the network.
|
|
|
|
|
|
Outdoor Switch-disconnector FLa15/60
used for vertical and horizontal mounting on wooden or concrete pole
Rated voltage 12, 24, 36 and 38.5 kV
Rated current 400 and 630 A
For decades DRIESCHER - Outdoor switch-disconnector have been used as line sectionalizers in medium voltage overhead line networks and have
proven to be extremely satisfactory based on their reliability and operating safety.
The switch is in compliance with the regulations as per DIN VDE 0670
Part 301.
The arc extinguishing device in its weatherproof housing, operates in accordance with the oil flow principle of the well-established DRIESCHER circuit-breakers and is shunted in the On condition.
The switch frame and the operating shafts mounted in bronze bearings are hot-galvanized. All insulators used in the construction are made of
cycloaliphatic cast resin (Color RAL 8017 brown).
The contacts with flat terminations in accordance with DIN 46206 are made of electrolyte copper and are silver plated.
Even after many years of operation, a spring guarantees a constant
contact pressure as well as easy and satisfactory switching.
The nuts, washers and spring washers of stainless
steel ensure corrosion-free connections even under extreme climate conditions.
Refer brochure 762e and 763e
|
|
|
|
|
|
Outdoor Disconnecting Switches
Fuse-Bases
Earthing Switches
Single- and three-pole
Rated voltage 12 kV, 24 kV, 36 kV, 38.5 kV
Rated current 400 A, 630 A, 1600 A, 2500 A and 4000
All switchgears mentioned in this list comply with the specifications of VDE 0670 Part 2.
All switchgears are equipped with expoxy resin insulators (colour brown, RAL 8017).
For decades the simple, robust construction proved a success in climatical different regions.
The base frames - a welded work made of sectional steel - and the operating shafts made of bronze are hot-galvanized.
All contacts with flat terminations according to DIN46206 and double disconnecting blades made of electrolytic copper are silver-plated and form loopless current paths.
The fuse holder contacts are designed to the operation of high-voltage, high-breaking capacity fuse-links according to DIN 43625.
Adequate cross-sections and suitable contact pressures result in an easy and troublefree switching even after many years of operation, even under
extreme conditions.
All disconnecting switches and three-pole fuse bases can be delivered with an earthing switch.
Disconnecting can also be equipped with spark quenching horns for disconnecting low currents.
Refer brochure 751e
|
|
|
|
|
|
DRIESCHER - Outdoor Switch-Disconnector
Type FLa 15/97
• Rated voltage 12 kV, 24 kV, 36 kV and 38.5 kV
• Rated current 400 A and 630 A
• 1-pole and 3-pole design
Contrary to former outdoor load-break switches in which it was common practice for the arc to be extinguished in oil, with the new developed outdoor switch-disconnector FLa 15/97 arc extinction takes place in a vacuum interrupter.
Based on a patented insulating system there is also no liquid or gaseous medium required for the external insulation strength of the vacuum interrupters.
The vacuum quenching device is embedded in a weather-proof insulating housing.
This switchgear is therefore also recommended for special applications (e.g. in water protection areas).
The outdoor switch-disconnector is capable of switching on its rated current as well as its rated short-circuit making current via the main contact system.
The disconnecting process is implemented via the shunt-connected vacuum interrupters, resulting in no external arcing phenomena.
A fully developed eccentric make-and-break mechanism operates the vacuum interrupters and ensures Class M2 with regard to the mechanical strength (corresponds to 5000 mechanical operating cycles).Fefer brochure 766e
|
|
|
The stop switch is used to shut down the wind generator if it is not to be operated or to prevent starting of the rotor when working on it. Wiring the stop switch is not obligatory if a charge regulator has been installed.
|
|
Sprecher Automation provides primary technology and secondary systems for high voltage switchgears.
|
|
Manufactured from pre-galvanised 2mm sheet steel, with watershed top and front access door
Outdoor - IP43 degree of protection
Manual operation - IP2XB Operator protection in open and closed positions
Freestanding, transformer coupled or transformer mounted
Direct connection to the transformer LV terminations via 'F' type flange
800A, 1600A, 2000A or 2500A main busbar rating
Off-load manually operated incoming isolators to match busbar ratings (800A, 1600A, 2250A)
Maximum 6 TP&N IP2XB fully shielded outgoing fuseways
J type 92mm fuseways up to 800A
Moulded case circuit breakers (MCCB) up to 1250A
Air circuit breaker (ACB) up to 2500A
Generator connections available
Bottom cable entry
Cable glanding plates or cable support cleats
Single or multiple core mechanical clamp or compression cable termination options
Available in PME or SNE configuration
Fitted with a 13A socket
|
|
Outdoor Switchgear
We provide low and medium voltage switchgear for outdoor use. Our equipment is available newly manufactured or re-engineered.
Product overview
- Low voltage 415 volt products
Suitable for direct transformer mounting or free standing:
- Fused pillars
- Air circuit breakers & moulded case circuit breakers up to 4000 Amps
|
|
Since decades, Sprecher Automation has been developing LV switchgears and distribution boards for auxiliary services in power utilities as well as for power supply and distribution in various industries.
Sprecher LV switchgears guarantee easy expandability of existing equipment whereas expenditures are limited by the actual system extensions.
|
|
|
The CPA-AMC system consists of a series of air-insulated modular cubicles with metal-clad compartments and withdrawable module technology for Medium Voltage primary distribution and industrial installations up to 17.5 kV.
|
|
Sprecher Automation provides two MV switchgears (M1 and M2) which are based on a highly modular and flexibel standardised system. The switchgear components are provided by ELATEC. Sprecher Automation supplies project management, overall and detailed planning, assembly, final assembly and final inspection as well as testing. Beside the factory-assembled delivery, Sprecher also provides on-site installation, commissioning as well as service and maintenance by its own staff.
|
|
Rapier RX
The Rapier RX range incorporates a modular design switch that can be configured to suit a variety of applications. Combining high performance and reliability, the Rapier RX rocking type switch can be a key element in rural distribution networks.
Rapier GX
Based on the latest developments in SF6 switchgear technology, the GX combines high performance and reliability. The GX Load break Switch can be manually operated or motorised for sectionalising, automation and remote control to suit your network requirements.
Rapier DSB
The Rapier Double Side Break 'DSB' range provides a powerful and cost effective solution for isolating a series of circuits and equipment in substation applications. Based on open terminal air break technology, the Rapier DSB range combines robustness and alignment reliability.
|
|
|
The CPG.0 cubicle range of the CPG system consists of series of SF6 gas insulated modular cubicles, GIS-type, for primary distribution configurations in medium voltage networks up to 36 kV
|
|
The Scimitar range has been built to meet stringent requirements and is corrosion resistant for durable outdoor and indoor use.
The switches are contained within a common stainless steel SF6 filled tank with the fuses mounted in air above the gas chamber. Each fuse is sealed against external influences and locked into its own chamber upon insertion. The units can be extensible for direct connection to form multiple plan switchboards without the need to access the gas chambers or for extra cabling.
Features
Ratings up to 15.5kV
Common switching chamber with sealed SF6 environment
Low gas operating pressure
Fully extensible
Indoor and outdoor
Freestanding, transformer mounted or transformer connected
|
|
|
|
|
|
Fuse distribution cabinet free standing
Freestanding or transformer coupled to ENA TS 35-2 via 'F' type flange to BS2562
Complies with requirements of ENA TS 37-2
2.5mm pre-galvanised sheet steel enclosure with weatherproof watershed top and front access door
Corrosion protected with polyester stove enamelled textured paint finished in admiralty grey to BS 381C shade no. 623
Outdoor - IP43 degree of protection
Manual operation - IP2XB operator protection in open and closed positions
1600 or 2250A main busbar rating to match specified busbar ratings
Off-load manually operated incoming isolators
6 or 8 TP&N IP2XB fully shielded outgoing fuseways
Extensible to 14 TP&N fully shielded outing fuseways to IP2XB
J Type 92mm outgoing fuseways up to 800A
Moulded case circuit breakers (MCCB) up to 1250A
Air circuit breaker (ACB) up to 2000A
Generator connections available
Bottom cable entry
Cable glanding plates or cable support cleats
Single or multiple core mechanical clamp or compression cable termination options
Available in PME or SNE configuration
|
|
|
The CGMCOSMOS system is composed of a set of reduced size modular cubicles, single or multifunctional, for different secondary power distribution configurations up to 24kV in both public and industrial settings.
|
|
|
|
|
|
DHSG-1 switchgear cabinet for twin drives with total load currents of up to 300A
The DHSG-1 flameproof switchgear unit was developed for coal-industry applications, but can also be used in other explosive mining atmospheres.
The DHSG-1’s extremely compact dimensions make it highly suitable for performing switching and control tasks on mobile mining machinery, such as loaders and drill jumbos, as well as for the protection of three-phase a.c. motors, transformers and lighting circuits.
The DHSG-1 switchgear unit offers the following advantages:
power-loss monitoring for overcurrent, short circuits and earth faults, including cold conductors
lighting output in the supply voltage with separate earth-fault monitoring
unit-running indicator in 42 V and 42 V output mode with earth-fault monitoring
intrinsically-safe controls with integral start-up warning and siren function
compact space-saving design.
The unit is designed for operating voltages of 500 V to 1000 V. Voltage switching is achieved by means of a simple plug changeover.
|
|
High-Voltage Switchgear
For high-voltage systems from 3.3kV to 24kV, AEC's metal-clad and metal-enclosed switchgear provide centralized circuit control . A complete line of functional units is available for control and protection of motors, transformers, generators, distribution lines, rectifiers, M-G sets, and similar power equipment. Each standard self-contained unit utilizes basic world reliable components including vacuum circuit breakers, magnetic blast breakers, instruments, relays, meters, instrument transformers, and control devices.
Convenient access to all components and use of vertical lift horizontal drawout breakers shortens the times necessary for inspection and maintenance.
|
|
TERASAKI designs / manufactures / provides Medium Voltage Switchgear which meet the various environmental conditions for industrial, and they offer highly reliability, quality, safeness and user-friendliness.
Standard Specifications
For Applicable Standards IEC 62271-200 / JEM1425
For Ratings
1: Rated Insulation Voltage AC 3.6kV , 7.2kV , 12kV , 15kV
2: Rated Frequency 50Hz / 60Hz
3: Control Voltage AC110V , DC100V
4: Bus-bar Current 630A , 1250A , 1600A ,
2000A , 2500A, 3150A
5: Rated Short-time Current Max. 50kA
For Constructions
1: Degree of Protection IP41 Indoor
2: Panel Construction Metal-enclosed Switchger and Controlgear
|
|
Low-Voltage Switchgear
Low-voltage metal-enclosed switchgear are designed for the control and protection of power circuits of fans, pumps, lighting and machines at 220V, 240V, 380V, 480V, or 600V. These switchgear are adapted for power centers such as central stations auxiliary power circuits for fans, blowers, compressors, pumps, lighting circuits industrial plants power and lighting networks, power feeders, lighting feeders power generation and auxiliary power drives for machine tools and material handling equipment.
|
|
|
|
|
|
AKD-20 low-voltage switchgear continues the tradition of the AKD switchgear line while delivering enhanced arc flash protection. Built to ANSI standards, its protection features include non-vented panels plus insulated and isolated bus, and it integrates our new state-of-the-art EntelliGuard® breaker-trip unit system. It also features an optimized footprint so that it now fits into a smaller area for the most common configurations.
EntelliGuard® G circuit breakers are the newest line of GE low-voltage circuit breakers, the next step in the evolution of a line known for its exceptional designs and performance. They are available from 800A to 5000A, with fault interruption ratings up to 150kAIC – without fuses.
Integral to the EntelliGuard G line are the new, state-of-the-art EntelliGuard TU Trip Units, which provide superior system protection, system reliability, monitoring and communications. The breaker-trip unit system delivers superior circuit protection without compromising either selectivity or arc flash protection.
The EntelliGuard breaker-trip unit system demonstrates yet again GE’s core competencies in reliable electric power distribution, circuit protection and personnel protection.
AKD-20 includes many features that address the needs of system reliability, arc flash protection and reduced footprint size.
|
|
|
|
|
|
GE's latest low voltage switchgear offering - AKD-10 OEM Module - offers the OEM customer a switchgear product package just for their needs. Now, OEM's can order single vertical sections that can be combined by their own personnel to form a wide variety of line-up configurations. There are many options for the modular sections which allows OEMs to order equipment that fits their manufacturing capabilities. This modular package gives OEM's the ultimate in design flexibility.
Features and Benefits
* Fabrication and stack pre-assembly by GE factory experts
* Detailed part drawings for fabrication and installation instructions that allow the OEM to cut costs by manufacturing parts in house.
* Many AKD-10 switchgear features are available
* Designed for GE's latest power circuit breaker -WavePro™
Product Scope
* Ratings 1600 Amp, 2000 Amp, 3200 Amp, 4000 Amp main bus
* Indoor NEMA 1 construction
* 60", 67", 74" stack depths available
* 3 wire or 4 wire with neutral
* 65 kA AIC & 100 kA AIC
* Removable top covers
* Blank instrument panels above each blank and breaker cubicle
* UR label
|
|
The Entellisys low-voltage switchgear is a breakthrough in power distribution protection, control, monitoring, diagnostics, and ease-of-use. System functionality is based on synchronized, real-time information from every circuit breaker, simultaneously processed in one place.
Entellisys helps to reduce costs, shorten schedules, and increase reliability throughout the process of designing, installing, maintaining, and owning your low-voltage power distribution switchgear. In one real-world example, Entellisys saved its user $50,000 during design and installation of a large system, and will save up to $500,000 each and every year during operation and maintenance
|
|
Our low-voltage control equipment operates motors and special consumers in potentially explosive mine openings in the area of mining and heading. They can be supplied for the following voltage levels: 500V and 1000V.
They are characterized by:
flameproof equipment compartment with central locking system
terminal compartment in flameproof or increased safety
installations such as power switch, vacuum and air connectors
standard enclosure with a volume of 540, 600 and 1000 litres
special constructions on request
|
|
|
|
|
|
Looking into the future!
Finland, Jyvaskala January 2006 Jean Mueller launched their new IP20 protected L-shaped busbar system for the Scandinavian market. This system was especially designed for the Jean Mueller, vertical SL-fuse switch disconnector cassette system to protect people from touching the live copper bars. Next to their already existing busbar solution with flat copper bars this completes the ranges for the Scandinavian market. The question now rises if there is an enclosure solution which can handle both busbar systems into one solution?
The Eldon answer for the ABB and Jean Muller Vertical cassettes
In close co-operation with both ABB and Jean Mueller, Eldon has developed a ready to use market solution for both types of cassettes. The SL-fuse disconnector of JM and the InLine cassette of ABB. The new enclosure type is called MCBAxxxxV for Vertical mounting of the units. Customers who are buying the Eldon Multi-Flex® solution can decide either to build-in the IP20 protected busbar system or the standards flat copper busbar solution. Both will fit.
|
|
|
|
|
|
AKD-20 low-voltage switchgear continues the tradition of the AKD switchgear line while delivering enhanced arc flash protection. Built to ANSI standards, its protection features include non-vented panels plus insulated and isolated bus, and it integrates our new state-of-the-art EntelliGuard® breaker-trip unit system. It also features an optimized footprint so that it now fits into a smaller area for the most common configurations.
EntelliGuard® G circuit breakers are the newest line of GE low-voltage circuit breakers, the next step in the evolution of a line known for its exceptional designs and performance. They are available from 800A to 5000A, with fault interruption ratings up to 150kAIC – without fuses.
Integral to the EntelliGuard G line are the new, state-of-the-art EntelliGuard TU Trip Units, which provide superior system protection, system reliability, monitoring and communications. The breaker-trip unit system delivers superior circuit protection without compromising either selectivity or arc flash protection.
The EntelliGuard breaker-trip unit system demonstrates yet again GE’s core competencies in reliable electric power distribution, circuit protection and personnel protection.
AKD-20 includes many features that address the needs of system reliability, arc flash protection and reduced footprint size.
|
|
|
GE offers a complete product range combining high operational safety with high technical characteristics.
|
|
|
|