{{#pushedProductsPlacement4.length}} {{#each pushedProductsPlacement4}}
{{product.defLight}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{#if company.requestButtonsVisibility.requestButtonQuestion == "ACTIVE"}}
{{elseif company.requestButtonsVisibility.requestButtonWhereToBuy == "ACTIVE"}}
{{/if}}
{{productPushLabel}}
{{#if product.innovationType}}
{{else}} {{#if product.newProduct}}
{{/if}} {{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement4.length}}
{{#pushedProductsPlacement5.length}} {{#each pushedProductsPlacement5}}
{{product.defLight}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{#if company.requestButtonsVisibility.requestButtonQuestion == "ACTIVE"}}
{{elseif company.requestButtonsVisibility.requestButtonWhereToBuy == "ACTIVE"}}
{{/if}}
{{productPushLabel}}
{{#if product.innovationType}}
{{else}} {{#if product.newProduct}}
{{/if}} {{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement5.length}}
current-limiting fuse / cylindrical / medium-voltage / for transformers
current-limiting fuse
E-Rated series

Amperage: 3 A - 600 A
VAC: 2750 V - 38000 V

... that these products are compatible with the NEMA standards for E-rated medium voltage fuses, which requires that fuses rated 100E or less are open within 300 seconds. The fuses ...

cartridge fuse / medium-voltage / for electric motors
cartridge fuse
R-Rated series

Amperage: 70 A - 700 A
VAC: 2750 V - 8250 V

... short circuits thereby saving medium voltage fuses from continuous stress of low over-currents that are below their minimum limits of interrupting values. According to NEMA guidelines, R rated fuses ...

current-limiting fuse / cylindrical / medium-voltage / for transformers
current-limiting fuse

Amperage: 0.5 A - 7 A
VAC: 600 V - 25800 V

The Potential Transformer (PT) fuses are specifically manufactured for safety of potential transformers. They are characterized with high interrupting ratings for current limitation. These are also integrated with current ...

pole-mounted fuse / medium-voltage / for electric motors
pole-mounted fuse

Amperage: 2 A - 200 A

High voltage fuse links (HV fuse links) are utilized to protect high voltage consumers, such as transformers, motors, capacitors, lines and switching devices, against ...

fast-acting fuse / cartridge / medium-voltage
fast-acting fuse
6 - 36 kV

The H.V.H.B.C. fuses from Driescher are designed to be automatic and it is an acting medium-voltage switchgears that have a voltage range from 6 to 36 kV. The device ...

current-limiting fuse / cartridge / medium-voltage / for electric motors
current-limiting fuse
ETI VV

... selection of high voltage current limiting fuse links for the transformer circuits. It also shows the specification for high-voltage fuse links for motor circuit applications. ...

cartridge fuse / medium-voltage / capacitor
cartridge fuse

Amperage: 80 A - 150 A

CCLB Characteristics: Stud mount with tapped terminals. Isolates faulted capacitor. Size amp rating 150% to 175% of capacitor rated amps. Maximum quality assurance. CCLW Characteristics: Stud mount and ...

current-limiting fuse / cartridge / medium-voltage
current-limiting fuse
CLE, HLE, HCL

Amperage: 0.4 A - 520.83 A

... in both double and quad barrel design. This Eatons Helix fuses are usually utilized in order to protect and secure components such as transformers as well as feeders. It has a general purpose fuses fitted ...

current-limiting fuse / cylindrical / Class RK1 / medium-voltage
current-limiting fuse
CLS series

Amperage: 0.4 A - 481 A

... The EATON CLS current limiting backup fuses is a top of the line component. It is mostly used in conjunction with high voltage motor starters to provide short circuit protection for individual motors. ...

cartridge fuse / power / medium-voltage / for transformers
cartridge fuse
Prime-MEC

Amperage: 5 A - 200 A

... board. PRIME MEC fuses are equipped with striker pins for trip indicators as well as for operating the related load break switches. Link type fuse holder enables easy maintenance and high stability ...

fast-acting fuse / pole-mounted / medium-voltage / power
fast-acting fuse
SMD series

Amperage: 8000 A - 25000 A

SMD® Power Fuses SMD Power Fuses are especially suited for protecting transformers, capacitor banks, and cables in outdoor distribution substations through 34.5 kV. They incorporate precision-engineered ...

See the other products
S&C Electric Company
fast-acting fuse / pole-mounted / medium-voltage / power
fast-acting fuse
SM

Amperage: 6250 A - 34000 A

SM Power Fuses SM Power Fuses are especially suited for protecting transformers, capacitor banks, and cables in outdoor distribution substations through 34.5 kV. Their precision-engineered nondamageable ...

See the other products
S&C Electric Company
cylindrical fuse / capacitor / medium-voltage
cylindrical fuse

CCLB Characteristics: Stud mount with tapped terminals. Isolates faulted capacitor. Size amp rating 150% to 175% of capacitor rated amps. Maximum quality assurance. CCLW Characteristics: Stud mount and pressure plate terminals. Isolates ...

cylindrical fuse / medium-voltage / for electric motors
cylindrical fuse
2 - 200 A, 7.2 - 36 kV | FMT series

MEDIUM VOLTAGE FUSES AND FUSE BASES, SERIES “FMT” FMT fuses are suitable for indoor and outdoor applications and are ideal to protect MV/LV transformers and MV ...

fast-acting fuse / cartridge / capacitor / medium-voltage
fast-acting fuse
10 - 100 A

Expulsion fuses (see figure S) are normally used to pro- tect banks with high powers usually installed outside, where there are many units in parallel. Using expulsion fuses is a practical cost-effective ...

radial fuse / medium-voltage
radial fuse
MRF 50

Amperage: 0.08 A - 6.3 A

250/277 Volt Radial Fuses Pre-dominant radial lead package with U.S (UL/CSA)., Europe (VDE/Semko), China (CCC) and Japan (PSE) safety agency approvals, allows use of a single fuse rating in products ...