The ML10 Gold Standard laser represents the ultimate in calibration for machine tools, co-ordinate measuring machines (CMMs) and other position and motion critical systems. In combination with the extremely accurate EC10 environmental compensation unit, the system boasts ±0.7 ppm linear measurement accuracy.
The ML10 Gold Standard system can improve performance through targeted maintenance and can correct linear positioning errors using error compensation.
|
|
The MCV-2002 “Two interferometers operating at the same time” utilizes a dual beam laser head module to accomplish simultaneous linear and angular (pitch or yaw, straightness, flatness) calibration of axes on machine tools, CMMs, or X-Y tables as well as surface plates. The software enables the operator to automatically collect linear and angular positions simultaneously or angular data on the fly in accordance with various industry standards. Material temperature, air temperature and air pressure variations are automatically compensated. linear measurement range of 33-feet (10-m) with 1 microinch (10nm) resolution, and an angular measurement range of 16-feet (5-m) with 0.2-arcsec angular resolution. Optional ranges up to 200-feet (60-m) linear and 100-feet (30-m) angular are also available upon request..
|
|
|
And' Sistem of Linear Calibration Compact for measures of movement and calibration of blots tools, CMM or tables XY. The Software allows the operator to collect automatically the data of linear positioning in agreement with the several international Standards comprised ISO, VDI and automatic B5.Compensazione ASTHMA of Temp. Material, Temp. and Pressio_ of Air. Field 15m (opzione50m). Precision 1ìm/m (1ppm
|
|
| ... products without technical information |
| |
The DS2 Docking Station provides the ultimate flexibility for managing your gas monitors wherever you use them. The DS2 gives you all of the benefits of consistent automated calibration, record keeping, battery recharging and instrument diagnostics for your monitors to limit your liabilities and safety hazards. Two way wireless and/or ethernet connectivity enables you to link up to 100 stand-alone Instrument Docking Stations (IDSs) from remote locations anywhere in your facility and relay the data back to one central database for total instrument management. A graphical user interface tool (DSSAC) allows an administrator to view operations on each Docking Station from a network computer, making it easy to track instruments, print reports, set events and change parameters for any location.
|
|
|
|
|
|
What if you could maintain and manage your fixedpoint gas monitor fleet without leaving your desk?
The advantages would be significant. Manually calibrating every fixed monitor in a facility is a time consuming distraction from your core business. The units may be in hard-to-reach places creating additional safety hazards. These and other obstacles make it difficult to follow industry best practices for routine testing and calibration.
iTrans™ DS2 Docking Station™ is the first system to automate calibration, record-keeping and instrument
diagnostics for fixed-point gas monitors. Hands-off maintenance and a snapshot view of your entire gas
monitor fleet allow you to:
• Maintain your gas monitors more safely, efficiently and reliably
• Increase equipment reliability
• Eliminate safety concerns
• Save money on calibration and testing
• Focus more resources toward your core business
A graphical user interface tool allows an administrator to view operations on each Docking Station from a network computer. From here, you can initiate calibrations and instrument tests remotely, print reports, set events, and run diagnostics for any or all instruments at any location.
The DS2’s flexible architecture minimizes installation costs, whether you’re managing one instrument or an entire fleet of fixed-mounted or portable instruments.
|
|
|
Gas sensors are usually installed in hard to reach places: inside pits, over vats, high under roof and skylights. To eliminate the labor and risk to personnel perfoming routine calibration on these sensors, Rel-Tek developed its unique Magikal and Magikal-II automatic gas sensor calibration (AGSC) utilities. These powerful technologies have been proven over the years at installations from Massachusetts to California , from Michigan to Texas. Users appreciate freedom from the calibration nuisance, while saving a lot of money to boot.
|
|
CalCheck is an easy to use reliable tool for the self calibration of gas and leak detection instruments, giving you peace of mind and confidence in the accuracy of the measurements you rely on.
For your convenience the same base unit can be used for calibration with many different gases and leak rates. Ion Science can supply almost any non corrosive gas at varying concentrations and the instruments leak is easily removed allowing the use of a specific leak rate when required ensuring calibration to your exact needs.
|
|
| ... products without technical information |
| |
The DS2 Docking Station provides the ultimate flexibility for managing your gas monitors wherever you use them. The DS2 gives you all of the benefits of consistent automated calibration, record keeping, battery recharging and instrument diagnostics for your monitors to limit your liabilities and safety hazards. Two way wireless and/or ethernet connectivity enables you to link up to 100 stand-alone Instrument Docking Stations (IDSs) from remote locations anywhere in your facility and relay the data back to one central database for total instrument management. A graphical user interface tool (DSSAC) allows an administrator to view operations on each Docking Station from a network computer, making it easy to track instruments, print reports, set events and change parameters for any location.
|
|
|
|
|
|
The MicroDock II is the world’s most advanced, compact and affordable automatic calibration, testing and data management system for portable gas detection equipment. Compatible with BW’s GasAlertMicro 5, GasAlertMicro 5 PID, GasAlertMicro, GasAlertMicroClip, GasAlert Extreme and GasAlertClip Extreme family, the MicroDock II is expandable to up to 10 docking modules (including up to 6 charging units).
- Fully automatic “hands-free” calibration & functional bump test
- Automatically verifies performance of audible and visual alarms
- No computer required
- Entirely self-contained
- Fully portable
- Lightweight and mobile
- Operates via line power or a set of four C-cell batteries
- Add additional self-contained docking modules to system via simple, plug-in connections-no external pressure transducers or gas lines necessary
- Simplify record keeping
-Verify proper performance
- Reduce maintenance costs
- Multiple MicroDock II systems can be connected via a LAN
- Multi-language support in English, French, German, Spanish, and Portuguese
|
|
The new CheckBox IMH automates the routine gas (bump) testing, calibration and management of Crowcon portable gas detectors and facilitates the traceability and routine maintenance of instruments. Capable of operating with up to 10 instrument interfaces, CheckBOx IMH is available for use with the Tetra, Triple Plus Plus and Gasman products.
* Automatic gas (bump) testing
* Automatic calibration
* Can use single gases or quad mixtures
* Up to eight gas inlets
* Five or ten instrument interfaces
* Accommodates pumped or non pumped instruments
* Data and event file uploading
* Stores and controls configurations
* Records all activities
* Provides reports and certificates
|
|
The Model 700E is a microprocessor based calibrator for
precision gas analyzers. Using a combination of highly
accurate mass flow controllers and compressed
sources of standard gases, calibration standards are
provided for multipoint span and zero checks. Up to 4
gas sources may be used.
In addition, the Model 700E can be equipped with an
optional built-in, programmable ozone generator for
accurate, dependable ozone calibrations and to produce
NO2 when blended with NO gas in the internal GPT
chamber.
|
|
GasCal 1100 Gas Dilution Calibrator
The Ecotech GasCal 1100 Gas Dilution Calibrator performs precise
gas dilution calibrations, ozone analyser precision checks and gas
phase titrations using an optional internal ozone generator. It is
ideal for stand alone use or incorporation into ambient air or emissions
monitoring systems.
• Single and multipoint calibrations can be performed using precise mass flow controllers
• Perform gas phase titrations (U.S. EPA Method) and ozone precision checks using an internal ozone generator (option)
• Parameter setup and output via inbuilt LCD and keypad or an external PC
• External remote control possible via data acquisition system or suitable gas analyser
• Mass flow controller zero stability drift less than 0.6 % full scale per year
• Optional Carry case allowing the GasCal-1100 to be securely carried from location to location
• Optional purge facilitates flushing of calibration gas lines
|
|
| ... products without technical information |
| |
|
RT - 100 optional Package that can be used for the calibration of Rotary Tables and the Rotary aces of blots some to 5 or 6 Aces. The operating field is of 360° with increments until 10 degrees. Precision 0,2 second of degree arc (0,06 millesimi). Automatic compensation for the assembly eccentricity. Portable Versione.economica and to motorized manual or automatic drive with servocontrol.
|
|
|
|
|
|
Features:
MarForm MFU 100 offers performance and possibilities in the reference class which in the past were only possible with much larger investments.
Thanks to its active air-conditioned cabin, the machine can also be used on the shop floor. Shorter distances and a faster intervention into the production process control reduce your costs and optimize the quality of your products.
A high degree of automation is achieved through themotorized centering and leveling table, which is a component of Formtesters, and the use of the motorized T7W probe.
Because of the complete separation of machine control and profile evaluation, the MFU 100 is easily expandable and ready for the future. The addition of other languages or special
evaluations is possible, as well as the implementation of new standards. The MFU 100 is already prepared for the use of new sensor technologies.
The MarWin software package offers all the features of a modern measurement and evaluation software. As a matter of course, impressive records and the electronic documentation on company networks are also available.
- Maximum measuring accuracy
- Software package MarWin
- Future-proof
|
|
| ... products without technical information |
| |
Torque wrench calibrator
CENTOR Meter W
The CENTOR Meter W torque wrench calibrator enables verification of torque wrenches thanks to a series of reference sensors ranging from 22 to 222 NM.
Torque wrench calibrator
torque screwdriver calibrator
CENTOR Meter H
A set of low-capacity reference torque sensors enables use of the CENTOR Meter H torque screwdriver calibrator to verify torque screwdrivers from 1 Nm to 6 Nm.
|
|
|
|
|
|
Norbar's Test Beams are designed for the static calibration of Torque Transducers. They are ideally suited to Norbar's transducers, but can be employed on other manufacturer's equipment.
Torque is generated by the application of a known force at a known radius from the centre of rotation of the torque transducer.
Designed to remove potential sources of measurement error, these beams can be used to calibrate Norbar torque transducers, and torque transducers from other manufacturers (where design permits), as well as mechanical test devices. UKAS length certification is provided with each beam.
The Beams are designed with square drives machined to the top limit of ISO 2725:1987. This minimises any play between the beam and the transducer. However, a combination of square drive tolerances, misalignment of fittings and elastic rotation of the transducer shaft inevitably cause the beam to rotate from the horizontal under load.
Norbar's Radius Ended Beams are designed with a /-8% degree usable arc within which the calibration accuracy is unaffected.
Additionally the beams are designed to apply load on a vertical plane which cuts through the square drive inside the transducer. This minimises bending moments on the transducer and, for safe operation, ensures that the beam will not fall out of the transducer.
|
|
Atlas Copco provides a complete line of products for measuring torque, angle, pulses and speed within all types of assembly industry.
Portable analysers:
The ACTA 4000 enables you to perform a full range of functions, from simple torque checks to advanced graphic tightening analysis. It comes in different models to cover all your needs, and is upgradeable. The ACTA 4000 together with the Tools Talk QAT software, is the user friendly complete quality management system! The system will automatically give you information when the tools are due for calibration. Quality management has never been easier!
Benches:
The JSB Light Joint Simulator Bench can easily be moved along the assembly line. This enables you to test your tools under actual conditions, with the right hose length and air pressure. The hydraulic brake
on the bench can be set to simulate actual joint stiffness. The JSB Light provides maximum flexibility and accuracy.
|
|
|
|
|
|
Experienced fastening tool users know that frequent calibration of air and DC electric tools is necessary to ensure exceptional performance. Ingersoll Rand offers users its Expert range of torque analysis systems. The ETT tabletop torque testers provide torque coverage for fastening tools (including pulse tools) from 1 to 30 Nm, while the ETA series of torque analyzers provide portable measurement capability with the ability to use external transducers or joint simulators. The ETW-A audit wrenches offer a portable and extremely precise way to audit actual joints following tightening with a traditional tool. And finally, Ingersoll Rand's new ETW-E provides labs and low-volume assembly operations the ability to fasten with true closed-loop control in a handheld cordless tool.
For users who don't have the capability or facilities to perform their own tool calibration, Ingersoll Rand also offers calibration service for any and all brands of fastening products. Call our toll-free number at the top of this page for details.
|
|
|
|
|
|
Features:
- Lifetime Guarantee
- Compliant with the latest Brinell revisions for ASTM E10
- Brinell Test block surface is lapped and polished providing superior testing accuracy
- Special heat treat process insures maximum consistency and repeatability
- Brinell test blocks certified in our ISO/IEC 17025 accredited laboratory
- Easy to read grain free surface
- Highest quality de-carb free tool steel and aluminum
- In stock for immediate delivery
- ISO 6506 Accredited
- Test measurement equipment is calibrated and traceable to NIST
- Free long form test block certificate with NIST traceability
WESTport Brinell Master Test Blocks are used to calibrate portable, bench and production Brinell hardness testers. Each Brinell test block is heat treated in a computer-controlled vacuum heat treat furnace to insure maximum consistency and repeatability. They are then blanched; ground, hand lapped and diamond polished providing you with impressions that are easy to read with precision accuracy.
Brinell test blocks are calibrated with five impressions and certified in accordance to ASTM E-10 and ISO 6506 on hardness testers calibrated and traceable to NIST. The arithmetic mean of the five impressions is inscribed on the block both in BHN Hardness and diameter in millimeters. Each Brinell block is calibrated with Tungsten carbide indenters. HB30 designates 3000 kg / 10 mm ball - the most common Brinell scale, HB5 designates 500 kg /10 mm ball and HB15 designates 1500 kg / 10 mm ball.
|
|
| ... products without technical information |
| |
|
|