To measure various climate and processes values with a handheld, user-friendly instrument requires extraordinary measurement technology. The handheld meter of the OMNIPORT 20 series meets these multiple demands.
The selection of the appropriate sensing probe and accordingly the configuration of the handheld meter allow for displaying the following values with the highest accuracy:
relative humidity RH
temperatur T
dew point temperature Td
absolute humidity dv
mixing ratio r
air velocity v
water activity (in oil) aw
water content (in oil) x
The robust housing of the OMNIPORT 20 allows usage in harsh industrial environments.The readability of the large illuminated display is excellent. The easy to understand menu and the practical thumbwheel navigation offer outstanding comfort.
An optional carrying case can accommodate the display unit, up to 5 sensing probes as well as accessories such as cables and calibration kits.
|
|
Vaisala HUMICAP® Hand-Held Moisture and Temperature Meter for Oil MM70 enables reliable detection of moisture in oil. It is ideal for the preventive maintenance of oil-filled systems. The brobe can be inserted directly into the process pipe through a ball valve - without draining the system. The measurement is independent of oil type, age and temperature.
The MM70 features the Vaisala HUMICAP® Sensor which is known for its excellent pressure, temperature and chemical tolerance.
|
|
|
|
|
|
The Honeywell 4112 dew point transmitter represents a technological breakthrough in moisture measurement. Absolute moisture in processes at high pressure and temperatures up to 185 degrees Celsius (365 degrees Fahrenheit) higher than existing equipment is now a reality, opening the door to better product quality, improved thermal efficiency and longer process equipment life. The probe will also stand short temperature excursions to 204 degrees Celsius.
The H4112 dew point transmitter is a direct intrusion, FM approved dew point and dry bulb temperature transmitter for industrial environments. The transmitter measures dew point and dry bulb (process temperature) simultaneously with local indication and retransmitted 4-20 mA outputs. The transmitter is designed to meet the moisture measuring requirements of a wide variety of industrial processes. End-users can now measure moisture where they had previously been unable to do so because of temperature limits, contaminants and harsh environments.
Advanced probe/sensor design virtually eliminates temperature effects and parasitic capacitance interference. New advanced materials and sensor assembly techniques enhance performance in high process temperature conditions. H4112 also has superior tolerance to contaminants. Common solvents, dirt, oil and other pollutants do not affect the stability or accuracy of the sensor. Polymer coatings on the sensor have excellent environmental tolerance ensuring accurate and repeatable dew point measurements
|
|
SKYWATCH Agros
Features :
This device can measure the temperature and humidity in the bales of forage, straw, Andean and others, but can also be used in air, vegetation and granular materials (cereals). The device is equipped with a probe extrèmenent resistant stainless steel with a plastic sleeve and an ergonomic stainless steel tip. Can not be used in a liquid.
|
|
|
|
|
|
A Hand Held Instrument for Fast Accurate Measurement of Moisture Content in Solid Materials.
The James Instruments Moisture Master utilizes the latest electronic technology to measure the quantity of water within its sensing field. The unit has two modes of operation the pin mode, and search mode. In the pin mode, two pins are pushed into the material and a high frequency field is created between these two pins. In the search mode the unit uses a high frequency capacitive sensor to sample a large volume of the material, instantaneously. Changes in this electromagnetic field are directly proportional to the dielectric constant of the material through which it passes. As the dielectric constant of water is almost two orders of magnitude greater than most non-metallic materials, variations in this parameter can be correlated to the moisture content. After extensive testing of various materials, relationships between the change in this field and moisture content have been determined. These relationships have been digitized and implemented using the latest in micro-computer technology, thereby allowing the user the direct readout of moisture content for concrete, masonry, hard wood, soft wood, gypsum, and brick. The pin method has been found to be most effective in low density materials such as fir wood or pine wood. The search mode has been found to be most effective for higher density materials such as brick, masonry, gypsum and concrete.
|
|
|
|
|
|
Portable instrument ms1 Set AM
- Optimal for portable application
- Robust stick sensor for material measurement
- Accurate electrolytic measuring technology
- Hysteresis-free, repeatable meaured values
- Integrated climate parameter processor
Measurement instrument ms1 Set AM
Precision portbale measuring device for the determination of the relative humidity %rh in materials via the special SARK-sensor. Thanks to the integrated processor the instrument is capable to calculate further climate parameter of the Mollier-hx-diagramm (absolute humidity, dew point, temperature etc.).
Large and clear LC display with %rh, temperature and stable value signal. For the ms1 Set AM the established electrolyte measuring cell is used. This enables an accurate, hysteresis-free and long term stable operating of the device.
The ms1 Set M offers an optimal cost efficiency and is well suited for the on site measurement in materials.
Application areas:
Determination of concrete and paper humidity, textile and food industry
|
|
Provides actual moisture content readings in the range of 6 % to 40 % for wood and 0.2 % to 50 % for gypsum. A reference scale and colored LED indicators provide qualitative dry to wet readings on other materials.
- 3 separate scales for plaster/concrete, wood and gypsum/sheet rock
- Audible set point indicator alerts you when pre-selected MC is reached
- Averages up to 100 accumulated readings
- Digital LCD readout with auto-timer shut off
- Easy one hand operation using the integral electrodes
The integral electrodes penetrate a maximum of 5/16 inches. The PM-9622 accessory electrode is for testing roofing, insulation, or other soft materials. For greater versatility, any other BYK-Gardner electrodes can be attached via the built in connector; please order separately.
|
|
| ... products without technical information |
| |
|
The Series TFXP Portable Transit Time Flow Meter features an advanced non-invasive flow measurement technology, providing a system with unsurpassed accuracy, versatility and ease of installation. Although designed for cleaner liquids, the flow meter can reliably measure liquids containing moderate amounts of suspended solids or aeration. Designed for long or short-term flow measurement surveys on full pipe liquid systems.
|
|
|
Series UFX Hand-held Doppler Flow Meters provide accurate and reliable flow velocity assessments in closed pipe, liquid systems. UFX requires that the liquid be either solids-bearing or aerated at a minimum of 100 ppm. The product utilizes a single, hand-held transducer which is placed on the outside of metal or plastic pipe. Within seconds after placing the transducer, the large LCD will provide a velocity reading in either FPS (feet per second) or MPS (meters per second). The UFX comes with a flow calculator/slide chart for conversion of velocity measurements to popular volumetric measurements.
|
|
|
|
|
|
Portable ultrasonic flowmeter FLUXUS F601 is ideal for troubleshooting, plant optimisation and for control of permanent meters.
Features
* Wide application range thanks to the ability of the transmitter to work with shear wave AND lamb wave transducers at all frequencies
* A single pair of shear wave transducers fits a wide pipe diameter range
* Rapid installation without process interruption
* Bi-directional measurement
* High measurement dynamics
The FLUXUS ® G ultrasonic flowmeters use the proven "clamp-on" technology. The flow transducers are simply clamped onto the outside of the pipe. The measurement can hence be put into operation without cutting into the pipe and without production stop. The installation costs are low, retrofitting is not a problem.
Since the transducers are not in contact with the gas, there is no possibility of chemical attack. There are no moving mechanical or pressure loaded parts and thus no wear an tear. FLUXUS G is ideal for measurements at high pressures or on lines with pressure peaks.
Two transducer types for a uniquely wide application range
All FLUXUS® G transmitters support both lamb wave and shear wave transducers at all transducer frequencies. In this way the measuring system can be optimized to even the most demanding applications.
The Lamb wave transducers are ideal for measurement at high flow velocities, in natural gas pipelines for example, or at low pressures, amongst others in compressed air circuits. The shear wave transducers cover a wide range of pipe diameters and wall thicknesses. They are the best choice for mobile measurement or for high pressure systems.
|
|
|
|
|
|
The FLUXUS F601 is a portable ultrasonic flowmeter. With its clamp-on transducers and its rechargeable battery, it is an ideal tool for service work.
The clamp-on flow transducers are simply mounted onto the pipe from the outside. Measurement is therefore non-invasive, and no process interruption is necessary for the installation. The transducers are not in direct contact with the medium to be measured and thus in no way submitted to pressure and wear and tear.
All transducer pairs are factory calibrated. All calibration data (including the transducer identification and parameters) is stored permanently in the transducers and is transferred to the transmitter automatically upon connection. This facilitates operation and a zeroing procedure is not necessary.
The user interface is adapted to the detected transducers. The instruments simply asks in a logical sequence for the pipe and medium parameters. The physical properties of a large number of pipe materials and media are stored in an internal data base. The status display enables even the inexperienced user to judge online the quality and precision of the measurement.
|
|
Recommended for clean fluids like water, glycol, oil and most chemicals. Portaflow ultrasonic sensors strap-on the outside of vertical or horizontal pipes from 2" to 40" (50 to 1000 mm) diameter. The ultrasonic signal travels through all common metal and plastic pipe materials. Sensors can be mounted without shutting down flow and there is no obstruction or pressure drop. Flow rate and totalizer are displayed continuously along with battery status, signal strength. Press one key to instantly change the units of flow measurement (e.g. from gallons to liters). Real time flow can be displayed in large numeric values or as a graph.
- Strap-on Ultrasonic Sensors
- Internal Battery and/or AC Powered
- Easy Calibration and Set-up
- 50,000 point Data Logger
- RS232 Serial Output
- 4-20mA Output
|
|
It's ideal for flow troubleshooting, balancing and checking performance of permanent flow meters. The new PDFM 4.0 is fast and easy to operate – you can mount the sensor on the outside a pipe in less than a minute. Use the built-in keypad and calibration menu to set up the flowmeter for your application. The PDFM 4.0 works on any liquid containing bubbles or solids and is recommended for "difficult liquids" like wastewater, slurries, sludge, chemicals, viscous liquids and abrasives. Measures flow through most metal and plastic pipes including PVC, ductile iron, carbon steel and stainless steel.
- Strap-on Ultrasonic Sensor
- Internal Battery and/or AC Powered
- Fast, Easy Operation
- Built-in 3-Key Calibrator
- Programmable Totalizer
- 50,000 point Data Logger
- RS232 Serial Output and Windows software
- 4-20mA Output
- Adjustable Sensitivity
|
|
|
|
|
|
Fuji
Fuji PortaflowX and TimeDelta are multi-use flowmeters for liquid media. Particular advantage: The clamp-on mounting of the ultrasonic sensors, so that any cutting of the pipe is unnecessary and pressure loss can be avoided. The clamp-on measurement is available either as a portable, battery run version, or as a non-withdrawable type. The handling of the PortaflowX is very simple. The user interface of the big graphical display is compatible to the Windows system, so that even inexperienced users can handle it without problems. The PortaflowX speaks four languages fluently and can be delivered optionally with an integrated printer, that can be used either for printing parameters or as a line recorder.
The TimeDelta can convince as well by its easy handling, its enlarged options for diagnosis and analysis and its particular measurement stability, even under difficult conditions. Due to the highly efficient 32bit technology and modern DSP-technique, PortaflowX and TimeDelta can be run under operating conditions, that until now have been considered as impossible for the clamp-on ultrasonic measurement.
|
|
Portaflow-X
This ultrasonic portable flowmeter consists of two sensors clamped on the pipe (DN 13 to 6000 mm, according to sensors) and of a digital converter operating on internal battery or on power line. It can measure bi-directional flow speeds from -32 to +32 m/s.
A large LCD graphic screen, a set of pop-up menus and a reduced number of keys make of this device a simple, powerful and friendly tool very appreciated by every person wishing to do a punctual measure of flow.
In addition to the display of flow and totalization, the PORTAFLOW-X also offers functions of data logging (40000 values), of graphic display of the measured value and of the resultant sound wave, and the storage in memory of 1 to 20 configurations.
A RS232C interface allows the connection to a PC computer. An optional graphic printer is available.
|
|
To carry out accurate measurements and rather than having to bore your pipes and being limited in control points, think ultrasounds and clamp-on probes : Think ULTRAFLUX !
The DigiSonic E is a portable flowmeter. It is designed for field operations. Measurements are immediate and presented in both graphic and alpha-numeric formats.
Its sensitivity and its accuracy on any size of pipe make it an outstanding portable device. Let's also mention the following original features : memory and display capacities, thickness and temperature measurements.
|
|
|
|
|
|
Stingray Portable Open Channel Flow Logger
A new, portable logger for area-velocity flow surveys in sewers, open pipes and channels. Stingray is designed for municipal stormwater, combined effluent, raw sewage, irrigation water and stream flow.
Stingray uses a submerged ultrasonic sensor to measure both Velocity and Level in the channel. It is mounted in the channel with a stainless steel bracket or a pipe band. No calibration is required. It operates up to 4 years powered by standard Alkaline D-cell batteries. Electronics are housed in a watertight IP67 enclosure and rated for operation from –15° to 60°C.
Each Stingray includes Greyline Logger software to retrieve and display logged data by RS232 or modem connection. The software calculates flow for round, rectangular, trapezoid and egg shaped channels plus flumes and weirs. After the data is downloaded, the software automatically creates a flow chart based on the pipe or channel size. The software displays it as a graph or a table, or you can export it to a spreadsheet program.
|
|
| ... products without technical information |
| |
Important Features of the Portable Model 966 and
Bench-top Model 965-10A Turbidimeters:
-Meet official specifications of USEPA, APHA, AWWA, WEF & ASTM. Accepted for NPDES and NPDWR compliance reporting.
-Factory standardized. Calibration of all 3 ranges are easily confirmed as per USEPA requirements.
-Supplied standard USEPA approved. Safe, non-carcinogenic and non-toxic. Stable, stays in suspension. No mixing or diluting.
-Measures turbidity in 3 ranges: 0-20, 0-200, and 0-1000 NTU. Resolution is 0.01 NTU in the 0-20 range.
-Direct-reading digital display. Eliminates incorrectly interpreting analog meter scale divisions.
-Simple 2-step operation without the need for standardizing. No prior training is required.
-Automatic decimal point shift and over-range indication.
-Optional flow-through cell for pumped or flowing samples.
-2-year instrument warranty with toll-free technical backup.
-Precision made in U.S.A.
|
|
The PONSEL turbidimeter allow you the possibility to measure the turbidity without water sampler.
You just have to put the sensor into the water to measure turbidity
Range : 0 - 4 000 NTU in 4 ranges
Meter/Datalogger : Field and lobaoraty instrument
-IP67 watertight
-100 000 data memory
Sensor :
-Infra Red nephelometric technology (ISO 7027 compliance)
|
|
The most important parameters needed for water analysis, especially in drinking water are now available in a portable meter.
You can obtain lab performance in the field by using the HI 93102.
It not only measures turbidity, but also pH, total and free chlorine, bromine, iodine, iron and cyanuric acid (CYS).
All this in the palm of your hand and in seconds!
Measurements are made quickly and repeatedly through a sophisticated, yet easy-to-use microprocessor.
In colorimetric mode, users can select between factory preprogrammed calibration or calibrating the meter on their own, and measure either concentration or relative absorbance of the sample.
Up to 25 measured samples can be stored in memory together with time and date.
|
|
Easy to measure turbidity.
You can easily measure the water turbidity anywhere with this portable sensor because it cannot be affected by external disturbance light.
Unnecessary to draw the water.
You just put the probe into the water to measure turbidity. You can avoid the hassle of drawing the water.
High durability
Controller Unit:
Waterproof IP67. Anti-bacterial metrical is used.
Sensor Unit:
Durable SUS316L is used. Optical window is made of sapphire glass.
It is equipped with a rubber to absorb the impact from wear and shock.
|
|
|
|
|
|
WTW has developed a new line of field instruments based on optical measurement offering the following capabilities:
• pHotoFlex: photometry, pH
• pHotoFlex Turb: photometry, pH, turbidity
• Turb 430 IR and Turb 430 T: turbidity
The instruments have been designed to extract the optimum performance from the latest generation optics optics with state-of-the-art LED technology.
Remarkable features include:
• Low power consumption
• Robust
• Display-driven user interface
• Waterproof
• Integrated smart cuvette adapter for 16 and 28 mm cuvettes
• Hand held
The exceptional versatility of the pHotoFlex, pHotoFlex Turb and Turb 430 makes them ideal for use in process control, water analysis, and the beverage industry.
Both pHotoFlex and pHotoFlex Turb are equipped with a pH function, measuring the full pH range from –2.00 to 16.00. The pH measurement is simplicity itself, offering automatic temperature compensation and auto buffer recognition.
For turbidity measurement the Turb 430 IR offers a large range from 0-1100 NT/FNU. Outstanding features include: Automatic 3-point calibration, GLP compliant data export via RS 232, calibration record and the setting of a calibration interval.
|
|
|
The user can designate up to 4 choices of wavelength at 350nm-1100nm of visible rays, thus it is being used in various fields such as chemistry, environment(water quality, air, soil), food, bioassay for residual pesticides, etc. In case of bioassay for residual pesticides to measure the inhibition level of residual pesticides or water analysis to measure the COO, TN, and TP levels of water, faster and more convenient measurement is possible with commercial test reagent
|
|
POCKET Colorimeter II
More than 30 flexible, single parameter instruments
- Easy operation
- Small enough for almost any pocket
- Reliable results without a mains connection
- Rugged construction yet lightweight
DR 800 series—compact colorimeters
The DR 800 models are preprogrammed for different numbersof tests:
– DR 820: 20 tests
– DR 850: 50 tests
– DR 890: 90 tests
All three DR 800s work best in combination with the practical HACH tests for reliable, fast results in wastewater, drinking water and process water analysis.
|
|
|
|